2011/03/22 City Council Resolution 2011-27
2011 RESOLUTION NO. X27 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ROHNERT PARK ADOPTING REVISED MANUAL OF STANDARD, DETAILS AND SPECIFICATIONS FOR WATER, STREETS AND ROADWAY SYSTEMS WHEREAS, the City Council of the City of Rohnert Park adopted the "Manual of Standards, Details and Specifications" (the "Standards ") on January 10, 2006 by Resolution No. 2006 -19; WHEREAS, the City Council of the City of Rohnert Park adopted the Bicycle Parking Standards adding to the Standards on November 28, 2006 by Resolution No. 2006 -275; WHEREAS, the City Council of the City of Rohnert Park adopted the Revised Sewer Standards on January 26, 2010 by Resolution No. 2010 -08; WHEREAS, materials and methods for construction have improved significantly; . WHEREAS, City Staff and the Professional Engineering community propose updating the Standards; and WHEREAS, updating and improving the Standards will ensure that new construction is of the highest quality, therefore minimizing maintenance costs. NOW, THEREFORE, BE IT RESOLVED by the City. Council of the City of Rohnert Park that it does hereby adopt the revised Manual of Standard, Details and Specifications for the Water, Streets and Roadway systems in substantially similar form as attached hereto and incorporated herein as Exhibit A and further described as follows; I . Volume 1, Chapter 1, Water Design Standards as shown on the attached revisions 2. Volume i, Chapter 4, Street & Roadway Design Standards as shown on the attached revisions 3. Volume 2, Chapter 1, Water Detail Drawings as shown on the attached revisions 4. Volume 2, Chapter 4, Street & Roadway Detail Drawings as shown on the attached revisions 5. Volume 3, Construction Specifications, as shown on the attached revisions. BE IT FURTHER RESOLVED that the City Clerk is hereby authorized and directed to keep on file the revised Water, Streets and Roadway Standards dated as of March 2011 in the Manual of Standards, Details and Specifications on behalf of the City of Rohnert Park. DULY AND REGULARLY ADOPTED this 22 °d day of March, 2011. 4pHKER7 PARk ATTEST: �_ CITY OF-RO [ N,ERT PARK Clerk AHANOTU: AYE — CALLINAN: AYE MACKENZIE: AYE STAFFORD: AYE BELFORTE: AYE . AYES: (5) NOES: (0) ABSENT: (0) ABSTAIN: (0) J "d City of Rohnert Park, Proposed Design Standards Design Standards for Public Improvements Revised March 2011 City of Rohnert Park Water Design Standards Design Standards Volume 1 for Public Improvements Revised 9etebe,-2494-oMarch 2011 Design Standards Volume I for Public Improvements Revised jn:m J L4jLjL%AL4jL ... March ..29.1.j. WATER DESIGN STANDARDS TABLE OF CONTENTS Volume I Design Standards I. Purpose ............................................................................................ ............................... W -1 II. Requirements for Improvement Plans and Subdivision Maps ........ ............................... W -1 III. Water Mains - General .................................................................... ............................... W -2 IV. Materials ......................................................................................... ............................... W -3 V. Connection to an Existing Public Water Main ............................... ............................... W -3 VI. Alignment ....................................................................................... ............................... W -4 a. Horizontal ................................................................................. ............................... W -4 b. Vertical ...................................................................................... ............................... W -5 VII. Main Sizing Criteria ........................................................................ ............................... W -5 VIII. Main/Lateral Cover ......................................................................... ............................... W -6 IX. Valving ............................................................................................ ............................... W -7 X. Service Laterals and Meters for Domestic and Irrigation Service .. ............................... W -7 XL Public Improvements for Private Fire Systems ............................ ............................... W -10 XII. Fire Hydrants ................................................................................ ............................... W -11 XIIL Backflow Assemblies (Except for Fire Lines) .............................. ............................... W -12 XIV. Pressure ......................................................................................... ............................... W -12 XV. Specialty Valves and Water Sampling Stations ............................ ............................... W -13 XVI. Easements ..................................................................................... ............................... W -13 XVIL Abandonment of Water Mains and Services ................................ ............................... W -14 Appendix "A" - Backflow Device Requirements for Specific Types of Use .......... T -1T�11,W 18 Design Standards W -i Volume 1 for Public Improvements Revised J u ""X � nntic o,��o,,,l�or � nn� µ yT2nnnnlnn: c �� yr 2-0-1-0-March 2011 WATER DESIGN STANDARDS I. PURPOSE To provide guidelines for the design of water utilities projects and thereby reduce the time required for processing the plans. These guidelines do not include, but may reference, additional conditions which may be promulgated by all other pertinent ordinances, codes, and official policy set forth by the Utilities Department or other departments of the City of Rohnert Park or other government agencies. These guidelines establish minimum acceptable design criteria. More stringent requirements may be imposed by the City Engineer based on specific project conditions. Portions of these standards apply to fire systems, both public and private, and are intended as general reference to aid in the design of the public water system. Final designs are subject to approval of the Fire Department. It is the responsibility of the design engineer to initiate written requests to the City Engineer for approval of any design concepts that differ from these criteria, verify additional requirements imposed, perform any necessary calculations or studies, and resolve specific design problems with the appropriate agency, department or division. IL REQUIREMENTS FOR IMPROVEMENT PLANS AND SUBDIVISION MAPS A. Provide a detailed utility plan showing onsite and offsite public and private water and fire protection systems, including mains, services, hydrants, and all other required appurtenances, and their connections to existing City- maintained water facilities. Show the location, type, and diameter of public and private water mains. Reference any existing fire hydrants within 300 feet of the project boundary. Show any wells existing or to be abandoned. When a separate irrigation service is necessary, an irrigation plan is required per Section X. N. of these standards. (See Section XI for submittal of plans for private fire systems.) B. Annotate the local agency information sheet of the Subdivision Map with any information that is needed to notify property owners of requirements for connection to the City water system. These include, but are not limited to: 1. payment of fees prior to issuance of Building Permits, 2. lots requiring pressure regulating valves or booster pumps, 3. backflow protection, 4. public water access requirements, such as gates or access roads. The appropriate information may be obtained from Public Works and Engineering. C. Miscellaneous specific items required on improvement plans are indicated throughout these Standards. Design Standards for Public Improvements W -1 Volume 1 rnr„-' �nntico,��o,,,l�or �nn�Tnn�nn�nnnct:erMarch 2011 Revise J(1111L(�l 1V1(1 ]ry L+lJrvl ll D. Before combustible materials may be delivered, stored or constructed on site, fire flow and access must be provided and approved by the Fire Department per current City Fire Code. In addition, public and /or private fire hydrants must be installed, flushed, tested, and operational. This information must be included on all improvement plans. Provide any necessary calculations with the submittal of improvement plans or with the Tentative Map submittal to demonstrate adequate fire flows are available. III. WATER MAINS - GENERAL A. Public water mains may not be designed outside the street right -of -way without City Engineer approval. B. In general, publicly maintained water systems will be designed only where they serve multiple ownership lots and where appropriate access for maintenance can be provided. C. Water mains installed at a slope of 15% or greater will be designed with restrained joints. The Design Engineer must provide adequate drainage measures to protect the trench from erosion. D. Water mains installed outside of any roadway, called "cross- country mains," must be Ductile Iron Pipe and will have suitable access. In general, cross - country mains must be isolated with valves in the public right -of -way and must be identified with blue locating posts (Carsonite 492 CW -112 or approved equal) at approximate 500 -foot intervals, at any angle point, and at the entrance to an easement. .... s®Identifyin posts should have vandal -proof metal bottoms. Access requirements as established in Section XIV of the Sewer System Design Standards may be imposed on a project based on site conditions. E. For system reliability, to minimize pipe size, and to minimize the number of people affected by a system shutdown, either for domestic or fire protection purposes, no more than 100 residential units may be served by a single -feed water system, providing it is hydraulically adequate. Where more than 100 units are to be served, a dual -feed (or "looping ") public water system must be designed to provide a secondary source of water to the project. Onsite private fire requirements, such as dual fire services and looping mains, will be determined by the Fire Department for residential and nonresidential developments. F. For purposes of leak detection and maintenance access, no reinforced concrete may be designed over publicly maintained water facilities. Unreinforced concrete will be allowed under special circumstances such as crosswalks. Design Standards for Public Improvements W -2 Volume 1 rnr„-' �nntico,��o,,,l�or �nn�Tnn�nn�nnnct:erMarch 2011 Revise J(1111L(�l 1V1(1 ]ry L+lJrvl ll G. Extent of water main improvements will be as follows: 1. Any offsite water main improvements needed to serve the project must be shown on the improvement plans, including upgrades to existing mains that may be required as a result of a flow analysis or modeling effort. 2. In general, water mains must be designed to cross the full property frontage or to the limits of the street improvements, whichever is greater. H. Streets with both water and sewer mains must be at least 20 feet wide, face -of- curb to face -of -curb. Streets with only a water or sewer main must be at least 1X20 feet wI" e. I lk � u�x kil �l 1X Ino lx �y L�f%;;,11TO t 11 XX 11T i TI%w + 0. IV. MATERIALS A. Service laterals will be polyvinyl chloride (PVC), Polyethylene (PE), or Ductile Iron Pipe (DIP) per applicable City Standards. B. 8 -inch to 12 -inch public water mains and 4 it ch 6 I"n"ch to 12 -inch private fire mains will be Polyvinyl Chloride (PVC) Pressure Class 150, DR18 per AWWA Standard C900, minimum or Ductile Iron Pipe Pressure Class 350 per AWWA Standard C151 minimum. Where the normal mainline static pressure exceeds 100 psi, Ductile Iron Pipe or PVC Pressure Class 200, DR14 must be used. C. 16 -inch diameter water mains will be Ductile Iron Pipe per AWWA Standard C 151, or as shown on plans and specifications. Where the normal mainline static pressure exceeds 100 psi, AWWA Standard C905, DR18 with a pressure rating of 235 psi or Ductile Iron Pipe must be used. . n�r�nrA *A n�r��r�.�Ar r���A D. 20-inch diameter an larger water mains will e ��1 � �y �� lu rlry ...wrappe AWWA C200 welded steele ......lur...DuctI"l° Iri P I" e ........ ........ ........ ........ ........ N' l N p.p........ E. Asbestos cement pipe will not be allowed under qLay circumstances. V. CONNECTION TO AN EXISTING PUBLIC WATER MAIN A. Indicate a "hot tap" for connection of service laterals 24-inch 2—inch in diameter and smaller. B. Indicate connection of pipes r-11-1-0-11V . -I"n"ch to 12 -inch in diameter with a hot tap or a cut -in tee in conformance with the provisions of the Water System Construction Standard Specifications Section 99 -1.20. Hot taps will be allowed only when no main line valves are required. C. Design a cut -in tee if additional valves are required on the existing main. If the new main/lateral is larger than the existing main, the tee and main/lateral valve will be the size of the existing main unless it is hydraulically necessary to increase Design Standards W -3 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico��o,�,�,or �nn� µyTnn�nnlnnn t x xl March ..29.1.j. the tee and valve to the size of the new main/lateral. Cut -in tee should not be closer than 2 feet from a joint on existing pipelines. D. Tie -ins to the existing City water system must be inspected by a Public Works Inspector and the improvement plans must be so annotated. E. Size -on -size taps are not allowed, except with specific approval of the City Engineer. Hot taps shall be two nominal sizes smaller than the main. F. In most major streets, or where the street surface is less than five years old, installation methods other than open cutting may be required. The City Engineer as appropriate will determine the requirements based on the condition of the existing street. VI. ALIGNMENT A. Horizontal 1. Alignment will be in accordance with the provisions of Standard 871. 2. The minimum allowable radius of curvature for an 8 -inch water main is main will be in proximity to an anode field, special design will be required for approval by the City Engineer. 6. All public water mains must be designed a minimum 5 feet from all structures, such as manholes or drop inlets. Provide a minimum of 3 feet from the lip of gutter for service connections and repairs. Water mains will be designed a minimum of 5 feet from the edge of easements. 7. All water main trenches that are parallel to and deeper than the footing of any adjacent structure must be designed at least forty -five (45) degrees from the footing as required in the Uniform Plumbing Code. Any Design Standards W -4 Volume 1 for Public Improvements Revised ju µ N x.. l u Marchxx20x1x1 exceptions must be approved in writing by the City Engineer. (See City Std. 517) 8. Where dual water mains are designed, a minimum 5 feet clear horizontal separation will be maintained. 9. In general, water main crossings over or under other underground facilities will be designed as close as 900 to that facility as possible. Crossings of less than 45° v�1 nnolYnnbennnnupr vnunnnvh lnnnnnntlrnnnunsnlgnnnniarvry ry rvvrvarvavineare not wallowed. B. Vertical VII. MAIN SIZING CRITERIA A. A hydraulic analysis is required for all water system design projects. The hydraulic analysis shall be used to verify flow demands and pressure availability for the proposed project. The analysis shall also demonstrate the effect the proposed project will have on the existing distribution system. The hydraulic analysis shall include, as a minimum, the following: 1. Under peak hour demands (excluding fire demands), the water distribution system shall maintain pressures above 40 psi. 2. Under peak hour xi xxy.....ean plus fire demands, the water system shall maintain pressures above 20 psi. Hydrant flow test data (static pressure, residual pressure and flow) used for design shall be reduced b 10 ercent. �T� °�A�;Y, A�,A.,T��r,,��. a n,r,� Y p V 14%;ll.._��,,, 111 ..1;�....%ky11�;...x xY11...� � Yll �,l....1 .L X.-pl aY . 3. U l.Vl ,cy ►7C.�111 ley �u�a ►311U.11 '"%; ►c1 &11�\..L 11111111111L�v u� "u �111L►7. Looping o water lines stanua u pracLl�ceshall be used In design to el min t�avold dead � nu en-end water lines. 4. Velocity in any pipe line shall not exceed 10 fps under any condition. Design Standards for Public Improvements W -5 Volume 1 rim„- �' �nntico��v nor �nn� Tnn�nn�nnn ct: er March 2011 Revise J(1111L(�l 1V1(1 ]ry L+lJrvl ll 5. Head losses in any pipe line shall not exceed 20 psi per 1,000 feet of pipe line. 6. Provide a separate hydraulic analysis for each phase of the project to confirm adequate system design. B. Allowable nominal sizes for public water mains are 8 -inch, 12 -inch, and 16 -inch. Mains larger than 16 -inch must have specific approval of the City Engineer. C. Public water mains must be sized to meet minimum Fire Code requirements in addition to domestic and irrigation demands. Private fire protection mains must be sized to meet minimum Fire Code requirements (see Section XII for fire flow requirements). D. The minimum new public main size is 8 inches. New public mains serving commercial, industrial and /or multi - family residential developments greater than two units, must be a minimum of 12 inches. Existing mains that will serve such proposed uses must be upgraded as needed to meet the current Fire Code. E. Analysis and design of water systems will be based upon the criteria listed in the City's Water System Master Plan where applicable. The City Engineer may require increased pipe size for overall system benefit. When the project is required to provide larger water mains than needed for the development, the applicant may apply to the City for oversize reimbursement. VIII. MAIN /LATERAL COVER A. Cover is the distance from the top of the pipe to final finished grade measured directly over the pipe. B. Typically, the minimum standard depths of cover for public water mains and private fire protection mains are: C. Where minimum cover is less than standard or greater than 8 feet, special permission from the City Engineer is required. Show mains with nonstandard cover in a profile on the Improvement Plans or Encroachment Permit applications. Where cover is less than the standard, Pressure Class 350 Ductile Iron Pipe is required. �A two -sack sand slurry mix or Control Density Fill (CDF) shall be used in paved sections where trenching within existing streets is being performed. D. Under no condition will cover be less than 24 inches. Design Standards W -6 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico��v nor �nn� µyTnn�nnlnnn t x xl Marchxx20xlx1 4A- 12- 16 -inch or Pipe Size inch inch =gin: h gin: h inch Larger Cover 36 -inch 36 -inch ?6 40 44- 48 -inch (in.) %;41 111 XT r � r n 111 V 11 inch C. Where minimum cover is less than standard or greater than 8 feet, special permission from the City Engineer is required. Show mains with nonstandard cover in a profile on the Improvement Plans or Encroachment Permit applications. Where cover is less than the standard, Pressure Class 350 Ductile Iron Pipe is required. �A two -sack sand slurry mix or Control Density Fill (CDF) shall be used in paved sections where trenching within existing streets is being performed. D. Under no condition will cover be less than 24 inches. Design Standards W -6 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico��v nor �nn� µyTnn�nnlnnn t x xl Marchxx20xlx1 E. The minimum cover for service laterals will be as shown on the appropriate City Standard Plan. Where service laterals have conflicts with other facilities, a detail or profile must be shown on the plans, or the plans must be sufficiently annotated to give clear direction for the installation. F. When designing a cut -in tee for a service or main connection that is larger than the existing main, the new assembly must be shown at a depth sufficient to allow the valves to remain below the street subgrade, which may necessitate lowering the existing main. IX. VALVING A. Valuing at intersections will be in accordance with the provisions of Standard 871. A minimum of three (3) mainline valves are required for "T" intersections and four (4) valves are required for cross intersections. B. All hydrants must be on separately valved sections of the public main, including fire lines serving private hydrants. C. Any water main which does not have a fire hydrant or lateral connection will have valves designed at approximately 1,000 foot intervals or as required by the City Engineer. Valves shall be spaced so that not more than two fire hydrants are out of service at one time. D. Water main valves must be designed outside of concrete areas wherever possible to facilitate repairs. X. SERVICE LATERALS AND METERS FOR DOMESTIC AND IRRIGATION SERVICE A. Developments shall be provided City domestic and /or irrigation water service via water meters located at the frontage of a public street. Design Standards W -7 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico��v nor �nn� µyTnn�nnlnnn t x xl March ..29.1.j. . . . . . . . . . . .. . . .. . . . . .. . . . . . . . . E. The minimum cover for service laterals will be as shown on the appropriate City Standard Plan. Where service laterals have conflicts with other facilities, a detail or profile must be shown on the plans, or the plans must be sufficiently annotated to give clear direction for the installation. F. When designing a cut -in tee for a service or main connection that is larger than the existing main, the new assembly must be shown at a depth sufficient to allow the valves to remain below the street subgrade, which may necessitate lowering the existing main. IX. VALVING A. Valuing at intersections will be in accordance with the provisions of Standard 871. A minimum of three (3) mainline valves are required for "T" intersections and four (4) valves are required for cross intersections. B. All hydrants must be on separately valved sections of the public main, including fire lines serving private hydrants. C. Any water main which does not have a fire hydrant or lateral connection will have valves designed at approximately 1,000 foot intervals or as required by the City Engineer. Valves shall be spaced so that not more than two fire hydrants are out of service at one time. D. Water main valves must be designed outside of concrete areas wherever possible to facilitate repairs. X. SERVICE LATERALS AND METERS FOR DOMESTIC AND IRRIGATION SERVICE A. Developments shall be provided City domestic and /or irrigation water service via water meters located at the frontage of a public street. Design Standards W -7 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico��v nor �nn� µyTnn�nnlnnn t x xl March ..29.1.j. B. Design meter boxes out of traveled ways and a minimum of 10 feet from street trees whenever possible. On narrow the minimum se -parationxxbetweenxxmeter x .............. xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxx.......................... boxes and street trees shall be 6 feet. C. Base any required hydraulic calculations for the water meter and service lateral sizes on criteria from AWWA Manual M22 and submit to the City Engineer for approval. D. The maximum velocity in domestic, irrigation, fire line, or combination water service laterals from the main to the meter is 15 feet per second. E. Maintain a minimum 5 feet horizontal separation between water and sewer laterals. F. Meter manifolds other than those shown in various City Detail Drawings will be detailed on the plans and approved by the City Engineer. G. Residential (single units). 1. Each lot must be separately metered. 2. A standard 1 - h 1. 1/2 inch dual water service lateral is preferred when practical to serve two single - family residential lots, providing each lot is less than 1/2 acre. Otherwise, provide an individual 1 -inch service lateral for a 1 -inch meter for each lot. �7....el nrA... li � u,viv. ......... .........3... Each lot with fire service to be served by a 1 -inch minimum or 1-1/2-inch service per Std. 863A. H. Residential with second unit (as defined in the City Zoning Code Section 20- I. Multi- Family Residential (3 or more units) 1. For triplexes or lots with three units, condominiums, or town homes, individual meters are required for each unit. Design Standards W -8 Volume 1 for Public Improvements Revised ju uµ N;T..�nntico��v nor �nn� µyTnn�nnlnnn t x xl March ..29.1.j. 2. For multi - family developments of 4 -99 units, whether rental units or separate ownership units, design for individual meters for each unit or master meters with submeters on each unit. 3. For complexes of 100 units or more, metering will be designed as in (2) above, except that at least two metered connections are required if the project is to be master - metered. I 4. See Section X. X_n ....... for irrigation meter requirements for any landscaped or common areas. ..........:.........:...All meters must be within public right -of- -way or easements and multiple meters will be clustered where possible. J. Mobile Home Parks 1. Mobile home parks that have rental spaces shall have a master meter (two master meters if more than 100 spaces) or each unit may have an individual meter. Parks with individually -owned lots must have individual meters. When master meters are used, the mobile home park owner shall sub -meter to the tenants at their own expense, and must roV4GJ]1i1g whey comply with PUC Requirements. 2. Individual City meters must be clustered and located within the public right -of -way or easement. 3. See Section X.--X—N. for common area irrigation meter requirements. M. Combination Services for Private Fire Service with Domestic and /or Irrigation Service 1. Only 6 -inch, 8 -inch and 12 -inch combination service laterals are allowed. 2. The combination service lateral must equal or exceed the size of the required fire line and must be hydraulically sized to provide adequately combined domestic, irrigation, and fire flows without exceeding allowable velocity of 15 feet per second. 3. A minimum 8 -inch combination service lateral is required for lots with unknown commercial, multi - family, industrial and shopping centers uses where onsite hydrants are not likely to be required for development. Design Standards W -9 Volume 1 for Public Improvements Revised ju µ N T.. l u; Marchxx20xlx1 4. A minimum 12 -inch combination service lateral is required for lots with unknown commercial, multi - family, industrial or shopping center uses where onsite hydrants are likely to be required for development. N. Irrigation 1. Provide separate irrigation meters for landscaped areas of all commercial or multi - family uses. 2. Provide separate irrigation meters for common areas of all condominium, town home, PUD, apartment complexes, and mobile home parks. 3. Provide reduced pressure backflow devices for all irrigation services. Backflow devices must be specified on the irrigation plan and must conform to City Standard (see notes) and current USC Approved List of Devices. 4. Sizing of irrigation meters will be determined by the design professional subject to approval by City Engineer. Irrigation meter size will be determined by the maximum flow required at the meter and will be based on AWWA criteria for meter sizing. Along with landscape and irrigation plans, the applicant must submit the planned square footage of planted areas and categories of plants to be used as selected from the following: a. High water use plants: turf, annuals, and container plants; b. Moderate water use plants: ornamental trees, shrubs ground covers, and perennials primarily irrigated by sprinklers. (Note that there may be some use of drip or bubblers in this category but not a predominance.) C. Low water use plants: drought tolerant plants recognized as having a plant factor of 0.3 or less and irrigated primarily through drip emitters. 5. Irrigation systems shall be constructed with purple pipe and fixtures. XI. PUBLIC IMPROVEMENTS FOR PRIVATE FIRE SYSTEMS A. Design plans showing private fire systems must be submitted to the appropriate Fire and /or Building jurisdiction for approval and may be included with the Public Improvement Plans for the project. B. Generally, the lateral size must be designed the same size or larger than the size required for the fire sprinkler system and /or the private hydrant system. Caution - onsite fire system design may necessitate changes to pre- approved public improvements. The hydraulic calculations for laterals serving private fire systems V V ».shall be based on the required fire flow �� ... C eper City fire spr lkl e� ....ue n u u V V 111 1 1 .. tTT If Ok TA _r fT4'A�] *AY' .. /?l11Yl YI ...tT7�� ...* ,.,.Y1A l.�T Al111'1 Cr *�!� TA (..RAT VV 1j[AAAL ..; V.�Y Y.;l... Y i..... ; Y YY �, vy..Y��� ..CYjLIL, �, � YY�, Y�;....Ti V co e C. All private fire systems that only serve onsite hydrants require above - ground approved backflow device double check valves in accordance with Standard 880. Below -grade devices such as detector checks or backflow devices are not approved. Design Standards W -10 Volume 1 for Public Improvements Revised ju µ N x..nntic l u March ..29.1.j. D. Double -check detector backflow assemblies are required for: 1. All connections serving commercial fire sprinkler systems; or 2. Any property with multiple fire service connections; or 3. Any fire line connections to properties with auxiliary water supply. 4. Private on site fire hydrants. E. Reduced - pressure detectors are required for: 1. Any fire suppression system using chemical additives such as antifreeze or fire suppressants; or 2. Any building where an-potential-ex4reme hazard to the potable water s stem exists, as determined by the City Engineer. F. For one- and two - family detached (du plex) residential fire sprinkler systems: .. ... ......... ......... ......... ......... ..I...... ......... ...... \.17�./.. .Q A.... ....�' ��.7. . *.'.Y17.7'�1 Idl1 .... .t. T..C!' A.'. .7. .0.... . 1. 7. �1.*. PY'... T.l IY'.... T. '.Y'P....C!Y1.Y''.Yl.�T.I..Q'�. .....�.'.iA ... .... .... .. 1 . v v lvly _ul�,�rll�urlrv►v _► y -►cvl vlYrvulcr �v► vV +��cvvl rlv _►lllllYV1► +��lx C� cri�'"�'"���r ��n�rl��iT I�AtT'A 'cr rAltii�'rAla . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........... �/ . .� .......... � �/ . . . ..... . . . . . .... y . . . . . . ... . . . . . . . . . .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . '11V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .......... . . . . . . . . . . . . . . . . . . . . . . . .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1LV1T iV;; G1V aul l l./ 11V VUV VV .. V 1V. 10 1V�1L11�CL 'i A_VkArA f T'rgA LINTLIflat" ArN,AL'� "rN+ rinll113+AA VIT'] *A4" VIT' *� +11 ArNl -"ALj; C'�11""INT Li yr 11`/ly lll` 111`/ ►J.... ►J1v111 tLV\.`iJ 11V1 \J 11\JlL1Ul\./ ..VV (.1c�, x .VV llll.. cxl` <LV111\. ►Jll\J j.. 1....... .y i'i' y � nAtAntor nhA& 4ankflllw acr cr AnibhAcs arA uV1�.. v11�i1 Larger size service laterals and meters may be permitted where hydraulic calculations indicate the need. G. The location of any Fire Department connection must be approved by the Fire Department. H. Critical uses such as hospitals, Jails, elderly care facilities, and others as determined by the City Engineer and /or the Fire Marshal, require at least two fire line service connections to separately valved sections of the public water main, so that service can be maintained in the event of a main line or service lateral shutdown. XII. FIRE HYDRANTS A. Design of hydrant locations must meet the Fire Code requirements and be approved by the Fire Department for logistics and by Public Works Utility Services for maintainability. B. Each hydrant must be on a separately valved main line section. Design Standards W -11 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico��o,�,�,or �nn� µyTnn�nnlnnn t x xl March ..29.1.j. C. Whenever possible, locate hydrants near street intersections. D. If it is not possible to locate near an intersection, locate the hydrant near a property line or where it will minimize interference with property use. E. Locate hydrants a minimum of 10 feet from roll down of driveways for commercial or multi - family sites and 5 feet from edge of sin �Ief�am�ildetach�ed residential driveway. F. On streets with raised medians or with four or more travel lanes, design hydrants on alternate sides of the street per current City Fire Code. Each side of the street will be considered independently relative to hydrant placement per subsections XII -G below. G. Residential property with one or two dwelling units per lot - Typical locations 1. Design hydrants with a maximum of 500 feet spacing, or as approved by the Fire Department. 2. Generally, design hydrants at intersections and then evenly distribute hydrants throughout the project. 3. No one or two family dwellings may be more than 250 feet from the nearest hydrant. H. Commercial, Industrial, and Multi - family (3 or more units) per lot - Typical locations 1. Generally, design hydrants at intersections or driveway entrances and then evenly distribute hydrants throughout the project. 2. No portion of the exterior wall of the facility or building maybe more than 150 feet from the nearest hydrant as measured by an approved route around the building per the City Fire Code. I. Minimum fire flow required at all hydrants: 1. Fire flow as specified in the following subsections is defined as the amount of water supply available in the water main nearest the flowing hydrant with 20 psi residual pressure. 2. Single and two family residential uses require 1,500 gallons per minute flow, except as in subsection U. 4. of this section below. 3. The required fire flows for schools, commercial, industrial, and multi- family residential (3 or more units) uses will be based on the City Fire Code. The water system will be designed so that 1,500 gpm is available from the hydraulically most demanding hydrant and the remaining flow required is available at the next most demanding hydrant(s), up to a maximum of 1,500 gpm per hydrant. 4. Fire flow requirements are under the jurisdiction of the Fire Department. The guidelines given above are general. Actual flow requirements must be verified with the Fire Department prior to submittal of plans. Calculations may be required by the Fire Department to verify the adequacy of the Design Standards W -12 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico� nor �nn� µyTnn2nnlnnn t x2 xl Marchxx20xlx1 proposed design. Mitigation measures may be required by the Fire Department if the minimum fire flow requirements cannot be met for a specific project. 5. The minimum hydrant lateral size is 6 inches and shall not exceed 50 -feet in length without specific written approval of the City p ineer. XIII. BACKFLOW PREVENTION ASSEMBLIES (EXCEPT FOR FIRE LINES) A. Backflow prevention assemblies are required to be designed in accordance with State of California Title 17 and current City of Rohnert Park, Backflow Regulations. B. All backflow prevention assemblies must be listed on the latest revision of the approved USC Foundation for Cross - Connection Control and Hydraulic Research list. Additionally lists of approved backflow prevention devices may be obtained by consultants from the California Department of Public Health, see the following web -site http:// www. cdph.ca.ov /certlic /drinkinwater /Pages /Publications.aspx. C. Design backflow prevention assemblies as near as possible to the water meter as shown on Standards. Refer to Rohnert Park Standards 869 & 876. D. Backflow preventers will be designed in accordance with Appendix "A." For uses not listed contact Public Works Utilities or Water Quality. XIV. PRESSURE A. To obtain water system data for these calculations, contact pu 1p ��vTvil . �Tt�l tyT c A4"� z l%Ac Flre Dlv slon at (707) 5 84 2641. A fee will be imposed if flow testing is required. B. Mainline 1. The maxi 'mum allowable static pressure in the system is 28.0 psi. The minimum a owa e resi ua pressure in the system is 6 psi. 2. The maximum allowable pressure in a high -level zone is calculated by assuming the reservoir full. In the Aqueduct zone or other reduced pressure zones, calculate the pressure by using the high setting of the pressure regulating valve at the nearest aqueduct connection or system regulator. 3. The minimum allowable pressure in a high level zone is calculated by assuming the reservoir drawn down 10 feet from the high water level. In the Aqueduct zone or other reduced - pressure zones, use the low setting of the pressure regulating valve at the nearest aqueduct connection or system regulator. Design Standards W -13 Volume 1 for Public Improvements Revised ju uµ N.x..�nntico��o,�,�,vr �nn� µyTnn�nnlnnn t x xl March ..29.1.j. C. Domestic service 1. The minimum allowable pressure is 20 psi measured at the meter. If pressure measured at any faucet is less than 35 psi, a pressure booster system is required. 2. If service pressure measured at any faucet exceeds 80 psi, a private pressure regulating device is required. XV. SPECIALTY VALVES AND WATER SAMPLING STATIONS A. Specific locations will be reviewed for each project by the City Engineer and Public Works Utility Services. B. Air release and vacuum relief valves are required at substantial high points in the system such as over a hilltop or at the upper end of a dead end main. C. Design pressure reducing valves to maintain overall system balance and to maintain service pressure levels within the parameters established within these system design standards. D. Typically surge or pressure relief valves are to be located near the low points of any high level pressure zone where discharge may be directed to an approved disposal system. E. Water sampling stations are required to provide representative sampling within each pressure zone. At a minimum, eight water sample stations are required in each pressure zone, one at each reservoir, at pump stations, and dead ends. F. Fire hydr4nts rants shall b used in IIeu of b1 ow -off valves at de ad d ends. Blow -off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... F . Fire .......................................................... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .......... . shall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . o ff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . valve s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . ......... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . o ff . . . . . . . . . . . . . . . . . . . . . . . . . . . assemblies in other locations are allowed. XVI. EASEMENTS A. A Public Water System easement must be dedicated to the City 'de over any public water system when it is designed to be installed outside a public right - of -way. Design Standards for Public Improvements W -14 Volume 1 Revised ju µ N T..u; March 2011 B. The easement must be a minimum of 15 feet wide. The pipe shall be centered within the easement. Wheremorethanoneutilityisinaneasement ., theminimum w dth xxxxxxx xxx xxx xxx xxx xxxxxxx xxx xxxx x xxxxxx shall be increased to a minimum of 20 feet. Additional width mav be required b ......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... ............................... the City Engineer. The easement will be dedicated as a Public Water System ..v..v..v ..v..v..v �.v..v..v .v..v..v� .v..v..v ..v..v..v .v..v..v ..v..v..v ..v..v..v ..v..v..v ..v..v..v ..v..v..v ........ ......... ......... ........ ......... ......... ......... ......... ........ ........ .�..... ........v ......... easement if It contains water only. It will be dedicated as a ubllc utilities .n.nn ..n.nn ..n.nn ..n.nn ..n.nn ..n.nn ..n.nn ..n.nn ..n.nn..n..n..n..n..n..n..n..n :nnn nnn nnn nnn nnn nnn nnn nnn nnnp ...nn ....nn ....nn ....nn ....... easement if it contains other facilities as well. C. Easements must be configured to encompass all publicly maintained appurtenances, such as water service laterals, meters and fire hydrants and will be generally centered over the facility. Separate access easements may be required depending on site conditions. When water mains are to be installed along a property line the easement will be wholly contained on one parcel. D. All property restrictions placed as a result of dedication of easements will be so noted on the Subdivision Map, or on the Easement Deed if the easement is not dedicated as part of a subdivision. Required notes are: 1. No structures may encroach on, above or below the surface of the ground in any public water easement. This includes footing of foundations or eaves from the roof of any adjacent structure, pools, ponds or outbuildings on slabs or foundations. Decks, sheds, or other structures which may be easily removed for maintenance of the water system may be allowed at the discretion of the City Engineer. 2.xxx No trees may be planted in a public water easement without first obtaining approval of the City Engineer. Trees may be allowed to the extent that damage to the water system does not occur from root intrusion and adequate access can be provided for maintenance and repair vehicles. XVII. ABANDONMENT OF WATER MAINS AND SERVICES A. Any existing water mains and service laterals that will not be used must be abandoned and must be shown on the Improvement Plans with appropriate notation. B. For all abandoned water services up to and including 2 -inch, annotate to remove the valve and saddle and install a full circle clamp on main under Engineering Department /City inspection. xxxx xxxxxxxx ..................xx..0 C x........................... For flan ed, tappin tees or mechanical ' oint tees up to and lncludI 2 annannannannannannannannannaannannannannannannannaannannaf g J ................. .�... inch, annotate the Improvement Plans to remove the valve and install a blind flange or mechanical joint plug under Engineering Department /City inspection. LE. Valve boxes for abandoned valves must be removed and so noted on the Improvement Plans. FF. Abandoned mains valves and risers located within any street structural section or nnn within any new trench must be shown on the Improvement Plans to be removed. GG. Show all water mains to be abandoned within the public right -of -way as removed or broken every 50 feet and filled with sand slurry pursuant toClty Standard 507 FIH. Show all pipes 4 inches and over to be abandoned as removed or plugged every 50 feet. X X. I Where a fire hydrant is to be abandoned, note that the hydrant barrel, xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxz break off riser, and check valve are to be removed, the bury is to be capped or plugged, and the lateral abandoned at main as stated above. Abandonment of fire hydrants must be approved by the Fire Department. Design Standards for Public Improvements W -16 Volume 1 rn m„ - �' � nntic � nor � nn� Tnn�nn �nnn ct: er March 2011 Revise J(4jLjL% L4jL 1V1(1 ]ry L+lJrvl ll Appendix-"-AL' W4terAlains-andAon-PotableT*efines Design Standards W -17 Volume 1 for Public Improvements Revised jn:m �nntic� nor �nn� µyTnn�nnlnnn t x xl March ..29.1.j. Appendix "A" BACKFLOW DEVICE REQUIREMENTS APPLICATION TYPE OF ASSEMBLY Auto Sales, Painting, Repair, Radiator work RP Auxiliary Water Supply (Contaminated Wells, etc.) RP Barber Shops RP Blood Banks RP Boiler Systems (any) RP Buildings with Booster Systems RP Buildings with 3 or more Stories or with fixtures 30 feet above the service RP Buildings with Sewage Ejectors RP Buildings with Storage Tanks RP Homes with Sewage Lift Stations RP Car Wash RP Camp Grounds /Trailer Parizs RP Cement, concrete, Sand &Gravel Plants RP Chemical Storage or Processing Facilities RP Dairy or Cold Storage RP Film Processing RP Fire Systems - Business /Residential (sprinklers with or without hydrants) or private hydrants) DC w /Det.Ck. Fire Systems - w/S rinkler in Hazardous Locations RP Gas Stations RP Gray Water System RP Heating &Air Conditioning (Using Water) RP Hospital or Medical Facility an Convalescent or Long Term Care RP Irrigation Systems RP Irrigation System w /Chemical Feed RP Laboratories (Commercial or Research) RP Laundry or Dry Cleaner RP Manufacturing or Processing with Toxic Chemicals RP Medical or Dental Facility (any) RP Mobile Home Park DC w /Det. Ck. /RP Ornamental Pools, Ponds or Fountains RP Painting Auto Shops RP Printing Shops RP Radiator Shops (all) RP Radioactive Materials RP Restaurant RP Restricted or Classified Facilities RP Schools RP Sewage or Storm Drain Facilities RP Design Standards W -18 Volume 1 for Public Improvements Revised March sx20xlx1.J-unu 1 -2 0 6 Appendix "A" APPLICATION TYPE OF ASSEMBLY Steam Cleaning Equipment an e RP Steam Generation RP Swimming Pools Public and Commercial RP Tank Trucks or Spray Rigs RP Veterinary Clinics RP Warehousing & Storage RP KEY: RP = Reduced Pressure DC w /Det. Ck. = Double Check w /Detector Check Design Standards W -19 Volume 1 for Public Improvements Revised March sx20xlx1.J-unu 1 -2 0 6 Appendix "A" City of Rohnert Park Streets and Roadway '0 Design Standards Design Standards Volume 1 for Public Improvements Revised epte ber 2 070,cloher 2 n W March 2011 Design Standards Volume 1 for Public Improvements Revised epte ber 2 070,cloher 2 n W March 2011 STREETS AND ROADWAY DESIGN STANDARDS TABLE OF CONTENTS Volume 1 Design Standards Design Standards ST -i Volume 1 for Public Improvements Revised c pten be 2 nn7 gfgMarch 2011 Streets and Roadway Design Standards I. Definitions ....................................................................................... ............................... ST -1 II. General ............................................................................................ ............................... ST-4 III. Street Design ................................................................................. ............................... ST -45 a. Geometric Standard Cross Sections ........................................ ............................... ST -5 b. Access to Public Right -of -Way — Curb cuts ........................... ............................... ST -7 IV. Street Alignment ........................................................................... ............................... ST -78 V. Street Grades ................................................................................... ............................... ST -8 VI. Intersections .................................................................................. ............................... ST -9 VII. Typical Sections .............................................................................. ............................... ST -9 VIII. Pavement Design .......................................................................... .............................ST -910 Design Standards ST -i Volume 1 for Public Improvements Revised c pten be 2 nn7 gfgMarch 2011 Design Standards ST -i Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 STREETS AND ROADWAY DESIGN STANDARDS I. DEFINITIONS "Alley" means any street contained in the private property or in a common owned parcel or easement(s), used primarily for vehicular service access to the back or side of residential properties, and for which normal building setbacks may not or do not apply. �z» ��-► 1'1 n �� -►r�i � ��-► ern ��i � GG » nnnnn n!�nnn�n� � ��'�n�n� n�n�►n�n.na� n�n�nnnnn� �n�' �►n�i�!� nnnnnnnnnn�n�nY.�?n�n�n �n� Pn�..... �n�n��r�n�n�n�n� n� � nnn . 1n A nnnn Rx A noAnnnn ..... �k'�nn r11 1.v1 1611/01 \V �11V 11611 IJ I l V V 1,a `lilt/ 11 L1, " 1 `L" v (4.y ` U.11<L L V I Ll� V 411 \ L►7 J ►7114111 1141 V L-Lx%, �J1 1111U.1 y Y17 71 Y1 !1_A (1 C (l l 1 (7.1.7 (� l_....._� l" _._Z (\ _1_l l'\'1_ ._7._l.. fly......_ �._C l..... l T l_ .._l'1 ►1_l l'1 ►_! __(� .__1 t �A......_� (11 1 A G. _ (�A 1 Lam, 1. T....... �'..►"' -%;i.......'lJ'.�.......�. �'��Yl � C � IJ.. �. �. �. � .......... ....�.��..........�:1.......... i�... �'.�..0 � ��� �:1.►�........'k'..�......... VIII...k y -1 ........ I. �........ L. �.... �. �.. �. �.+` �..........' �V.... rul- �....... � .�.�.�.��.�..�.�.�.�.�........0 �.�..� �:1..►1�..►�........��.�+1 �.......+�� lJ ���� 1.�. -%;i �........t.�`...'�i+"V...11 � L x..x..x ..x ..x..x x..x.. x...x..x. x. _1...x.. x ..x..x..x..x. x .x.... -tt x..x..n' . x /... c- x x.x... _x....x.. x ...x... x ..x..x.. ..x x..x..x x Px x.x.. -:s: x centers to the gle�ter region. rtvl��1/�I�g��nl tre�,tsxx_ax V� .toxxxla xSxexxfrnax ,art T k r" v %�.�,��. e ........�x..T......... � a�.� 0 � 0......... �.T fb..�....... ... �1.......�..,�.. Nut 41.11 1 �vk 411- LL11C110 11141+ VL VV11►71�+Li Vll lJ`11 41 'V41►7'v -" - V410V V4L►71i7 V�+ ll v 1�1V�+ L11�111'LV1 "Avenue" is a transitional street connecting residential neighborhoods to commercial centers, shopping centers, and other neighborhoods. "Bike lane" means those on- street bikeways which are part of the normal street section and provide marked bike lanes which delineate the separate rights -of -way assigned to bicyclists and motorists. "Bike path" means a separate, off - street bike path which is not part of the normal street section. "Boulevard" is a regional street that provides multi -lane access to commercial and mixed use land designations. Boulevards have medians and bike lanes. "City Engineer" shall be a civil engineer registered by the State of California and shall be designated by the City Manager to discharge those duties prescribed hereinafter to be performed by the City Engineer. « oltecto 'xr n xl inxnx lxxx Street "xxxx €inc u esxxx Ave n exsxxxx�n xxMain- xxxS ree s xxxx shall ...the... rimy F lL1 JV►7v xj1 1114V1 +v )4111 1.141111V 11'V111 111t; V10 %;i :111 1'VlJC11 011N;;wN;;wL;7 411111 11"11,%a11i16 1.1411111) VU lllV 11VC11%wou nr�orin� �ror�lr�1"�n� c� *roo* r�r 11"��ornor��11"�rV +rn 0+1 -,ao* n1" A 1%n"AII " fr;r% +r% n r r r l.. n�. �.. �. n.. n. �.. �. �. n.. n.. n.. n. .�n�l�.���..n..�.�n..n..��.�::n ��.:n::�.�n.�.� n�:�.n..n.� �.:� �nr+ �.�..��n�::� �.�..n..n�..�.n ��.�:�.n�.�..n:�+������.:� ��.n�.:A����..�'T' �..�- ���.��..�..�..�..n..n 4111V111�1 VV11�V1V1 ►7111��1. 1L ►7114111 ►7�1 V � 41►714111 1,1VV�►7►7 lV 1.IVlLll111� �J1V�J�1111�►7. �V11�V1V1/ 114111►7111V11411 �1......._.. (l� 1.1 1 A G�. �• 1r 1_r A C1 1_ 1 .......... .."1 �l..rX�_� (\�•� (l_(\r A 0 ..._� (\ r?��'\'1_�'1 ► �� r��.._� � � �1 1��� 1r......�1 1_/ A. 0"'A 1P 171_ � r? r1�� 1 1_x'1'\ �� (��.._ "a_�.. i1..1...V......i........�1J 11111.............1.. ► �1V11.. 1..". 1....... 1. 1.. 1....... 1. 1. J.'. 1.. 11�1J'..►........'........'' lJ` 1. 1. 1. 11. 1. 1..... 1.. 1........ 11... V.. 1...►......... 11.......►. 1..... V'.... 1...... ...�Cy.1.1.1.1.1.1..1..1J..1..1 districts. "Cul -de -sac street" shall have the primary purpose of serving abutting land use and connecting to the nearest appropriate local street. It is a minor street with only one outlet. "Development" means and includes, but is not limited to, the subdivision of land, the construction of new structures or buildings, and changes or renovations to existing structures or buildings and the attendant construction of improvements, either of public or private nature, for which approval by the City of Rohnert Park is required prior to commencement. "Driveway" For the purposes of single - family detached housing, "driveway" means a way for vehicular traffic providing access to four or fewer lots or units over a common parcel or easement(s), and necessary service and emergency vehicles, but from which the general public may be excluded, and which are not maintained by a public agency. Driveways shall meet all provisions of the California Fire Code, as adopted by the City, with respect to Fire Department access where such serve as Fire Department access. "Industrial Street" shall be public and private streets located within industrial areas as defined on the current City zoning ma or roadways that primarily serve large trucks transltln2 to and Y p ................. from retail centers. "Lane" is a public or private access to 10 residential units or less (see City Std. 200C). "Local streets" means a street that provides access to individual sites. nr *r xxxxx xxxxrxxxe xx xxxxxxxLocal stree, ts include Minor Streets., n n n N e i hborh o od Streets., La nes � A lxxlxxe xx xs xx� xxUxxxxxtxixxlxxixtxxY .x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x. x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.. .x.x.x.xxxxxxx xxxx x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x. x.x.x.x..xx.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x.x..xx.x.x.x.x.x. x Access Roads, Trail cLoo Streets and Cul -de -sac Streets. On street parki .. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n required on Minor Streets and Neighborhood Streets. "Loop street" shall be a one -way street providing access to a very limited number of residential houses. Use is extremely limited (see City Std. 200B). "Main street" provides access to neighborhood commercial and mixed use districts. 200 feet apart, or that they include aleft -turn pocket. This provision is intended to maximize access between neighborhoods. Driveways are permitted, provided they are right- turn -only and at least 100 feet apart. A deceleration lane must be provided for each driveway. No on- street parking is allowed. Minor Arterial streets include Parkways. "Major Collector" means to provide circulation within and between neighborhoods. Driveways are permitted, provided they are right- turn -only and at least 50 feet apart, or that they include a left -turn pocket. No on- street parking is allowed. Maior Collector includes Boulevards. e "Minor Collector" means to provide circulation within and between neighborhoods. Minor Collector streets shall have the primary purpose of intercepting traffic from intersecting local streets and handling traffic to the nearest arterial /regional street or intercepting traffic from one collector street and handling traffic to another collector street. It shall serve as an access to abutting properties. Minor Collector streets connect residential neighborhoods to commercial centers and service commercial districts. On- street parking is required on both sides of each se ®ment of a one -way couplet. Minor Collector streets include Avenues, Main Streets, and Industrial Streets. /� /� GG�/� A l A 1.� A 1.�+ A 1.�1 A L1I\ !\ A N !Y A !Y T7A !\ !\ T T T T N A !Y !\ 7I� 7A7 L1I\ A 7AT T 7I� 7 T 7MI� A !Y !\ 7 !Y T A T A A 7 ■ 7 T A T- L1I\ A T T !\ L1I\ --4- A T ■ A 7A !! !\ Design Standards ST -4 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 "Minor street" shall have the primary purpose of serving abutting land use and handling traffic to the nearest collector street. "Neighborhood street" shall have the primary purpose of providing access to small residential areas and shall specifically not be used for through traffic. The various streets within this designation are the one -way loop street, the lane, and the neighborhood street. v vvv v_vv vvvvv "Parkway" is a connection between towns or through a natural area and are not designed to accommodate adjoining development. "Private street" means a way for vehicular traffic providing access to lots or units over a common parcel or private easement, primarily by the owners or occupants of the common parcel, and necessary service and emergency vehicles, but from which the general public may be excluded, and which are not maintained by a public agency. Such streets may be designed and constructed to different standards than public streets in the following areas: surface treatment, street lighting hardware, signing, and entry islands. Private streets should not connect two or more public streets (except when necessary for internal circulation or emergency vehicle access) and shall be designed and constructed to the standards of public streets in terms of minimum width (may be reduced when meeting specific criteria — see City Std. 200A through L) structural section, curb, gutter, sidewalk, and all other aspects not specifically referenced above. No City enforcement of "no parking" signs or other such regulatory signs shall be provided for such streets. Access shall be through a standard curb cut. "Public street" means a way for vehicular traffic, whether designated as a local, transitional, regional /major thoroughfare, freeway, or other designation, which is improved to City standards, dedicated for general public use and maintained by a public agency. "ifreet!Lshafl "Public way" shall mean any street, channel, viaduct, subway, tunnel, bridge, easement, right - of -way or other way in which a public agency has a right of use. "Regional Streets" (equivalent to Arterial or Major Streets; includes Parkways and Boulevards). See "Arterial /Regional Streets." Design Standards ST -5 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 "Sidewalk" shall mean a Portland Cement Concrete (PCC) surfaced area for pedestrian usage located within the public or private street right -of -way or sidewalk easement and included as a standard element of a street section. "Street" shall include avenues, highways, lanes, alleys, crossings or intersections and courts which have been dedicated and accepted according to the law or which have been in common and undisputed use by the public for a period of not less than five years next preceding, or which have been dedicated to a semi - public use. "Street right -of -way width" shall mean the shortest distance between the lines delineating the public right -of -way of a street. "Street width" shall mean the distance between the curb faces of a street or edge of pavement where a curb face may be omitted by approval of the City Engineer. "Transitional Streets" (equivalent to Collector Streets) connect residential neighborhoods to commercial centers and service commercial districts. Streets in this category are the Avenue and the Main Street. "Walkwa /Trail mixed use)" shall mean a ublic or rivate aved or rock- surfaced xxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx�xxxxxxxxxxxxxxxxxxxxxxxxxx�xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxx�. tt p p p p excludin2 sidewalks, for the use of pedestrians., bicycles and horses. . n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n. nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnnnnnnnnnnnnnnnnnnnnn......... .. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. n.. ............................... "Walkwa /Trail edestrian " shall mean a or or rock- surfaced xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx yxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx( xxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx ......xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx pxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx pxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx pxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxx......xxxx ............xxx1. excludin sidewalks for the use of ......... ............................... ......................................................................................................................................................................................................................................................... �............................................................................ ............................... Design Standards ST -6 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 II. GENERAL A. For purposes of street layout and design, streets shall be classified as: anorn.Arternial xxxxxxxxxxxxxxxxxxx�xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 1. Parkway xxxxxxxxxxxxxxxxxxxxxxxxxx �x. Minor Arterial xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx . .............................................................. Ma or x Collector 1. Boulevard Minor Collector 1... Avenue ........... ................ ............................... 2. Main Streets 3. Industrial Local 1. Minor Street 2. Neighborhood Street 3.. .......... Lanes, 4 ...... Allevs. 5. Utility Access Road, Trails /� nnAC�c��iT 6 .................Loop Street ...nn .Cul -de -sac Street i nal ...n,. 1�1zTXXT ,�_�RNX,IA7V r0�.. c N,,4n;rxr Oxy xxxxxxx xx2 xxxx.x..x..x..x x x x x..x..x..x sxt i � x -Y e.t.—s ......................................................................................................................................................... �'...�.....a�.a...�r..a...� a�... �. csriaciVica Z A4n " C +,,pp+ r AX T A "IIA C uvuvuvuvuvuvuvv�v.v uvuvuvuvuvuvuvuvuvuv�" �° �����ivuvv►:: �° ��i° �: i� °cc�uvv�uvv�uv�uv�i�i�ii�:i °►� nnnnn nnnnnnnnn nnnnnnnnn nnnnnnnnn nnnnnnnnn ....t nn�r�nnn non V V bl l Aa. ........................................................................................................................................................ 1.. �........................................... ........................ N.....4.i rxv.. r� v..v..v v..v..v v..v..v v..v..v v..v..v - 1 1 1 V \.L 1xYx f n.:n::n ..n.:n::n ..n.:n::n ..n.:n::n ..n.:n::n.:n::n V . T LU.11�►7 .7........ � 1.:A�.TG!.: ...A .I V.Y: 'k � 0 ....... xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxx.x ................................. A T 1 xti- 11ty xxxAcc.� ...R.oud -�... �xx ;lei B. Street design standards shall be used for the design and construction of all private and public streets. C. Deviations from these standards may be granted by approval of the City Engineer. E. Reference Appendix D: City amended California Fire Code. Two entrances required for the following: a. Building exceeding 62,000- square -foot area b. 30 units or more F. No half streets will be allowed. t i TREET DESIGNS A. Geometric Standard Cross Sections Item Minimum Width/Length Street Classification Center median 16 feet Parkway 16 feet Boulevard 16 feet Avenue Travel lane 14 feet Industrial 11 feet Parkway, Boulevard 10 feet Avenue, Main and Minor Street cl 10 feet Neighborhood Street 12 feet (two-way) Lane Parking lane or shoulder feet Industrial 8 feet All others except Neighborhood Street 6 feet Neighborhood Street Curb lane (no Parking or Bike lane) 2 feet increase to curb face Local streets 1 foot increase to curb face All other streets Bike lane 5 feet All streets Divider between frontage road and arallelin road 8 feet, curb to curb All streets Left turn lanes: Double Single Two-Way Two 1 1 -foot lanes 10 feet 14 feet All streets where required All streets All streets Right turn lanes feet All streets Curb radius for cul- de -sac 4-48 feet (w /parking and no island) Cul -de -sac 448 feet (no parking and with an island) Cul -de -sac 448 feet (no parking and no Cul -de -sac Design Standards ST -8 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 Sidewalks — island) Main streets — required on both sides Note: An island in a cul -de -sac (other than those shown in Standard Drawings, when proposed, will require review and approval by the City Engineer, who shall determine the use of the correct turning radius, compliance with re uired access for emer enc vehicles, and any other required design criteria. Maximum length 500 feet (or as Cul -de -sac from projected curb approved by the or edge of pavement City Engineer) line of intersecting 5 feet All streets in PD, one -way loop streets, as street to center of approved by Planning Commission — turnaround required on both sides (widen at Length of streets 150 feet from the All streets allowed with no Fire projected curb or minimum clear sidewalk) Department- approved edge of pavement Where applicable turnaround line of the cross Sidewalks — 10 feet Main streets — required on both sides contiguous with tree (widen at obstructing locations to provide wells (where 4.5 -foot minimum clear sidewalk) permitted or required per Standards) Sidewalks — 5 feet All streets in PD, one -way loop streets, as contiguous approved by Planning Commission — required on both sides (widen at obstructing locations to provide 4 -foot minimum clear sidewalk) Sidewalk — 5 feet Where applicable meandering (where permitted by Standards) Sidewalk easement To back of All streets where applicable sidewalk Public utility 5 feet behind right- All streets where required easement of-way *Lane requires sidewalk for 5 or more homes, one side minimum. Note: Sidewalk one side as approved by Planning Commission. B. Access to Public Right -of -Way — Curb Cuts Design Standards ST -9 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 1. Each vehicular passageway to any parking or loading facility to or across a public right -of -way shall comply with the following requirements: a. Curb cuts shall be a maximum of 41 feet in width for non- residential uses, except as otherwise approved by Conditional Use Permit. Minimum of 12 feet for one -way, 24 feet for two -way. b. Driveway widths, within residential areas, shall be a minimum of 12 feet in width for single driveways, a minimum of 16 feet for double or triple driveways up to a maximum of 24 feet, except as otherwise approved by Conditional Use Permit. C. Wherever feasible, curb cuts serving adjacent uses shall be combined to minimize the number of entrances onto a public right - of -way on any block. No curb cut is allowed when it is less than 6 feet from an existing curb cut. d. Only one curb cut may be installed for any parking or loading facility, except that one or more additional curb cuts may be allowed if the City Engineer determines that each additional curb cut is necessary for the efficient operation of the facility and will not significantly reduce street capacity and traffic safety. Twenty feet top to top on the curb island is required between driveways on a single parcel. e. Any curb cut in a residential area on a corner lot shall be located at the farthest point possible from the curb return and outside of the sight vision triangle. f. In commercial /industrial area, a minimum of 200 feet required separation between driveway and the intersection of two arterial and /or collector streets. g. Except as otherwise approved by the City Engineer, curb cuts for any circular or "through" driveway must meet the following requirements: (1) The curb cuts for such driveway shall be at least 20 feet apart top to top and a minimum of 5 feet from the side property line. (2) The combined width of the curb cuts shall not exceed 50% of the lot frontage. IJI.IV. STREET ALIGNMENT A. Street alignment shall generally conform to the circulation element of the City's General Plan. Streets shall be aligned with adjacent existing streets by continuations of the centerlines thereof, or by adjustment by curves, and shall be laid out for the most advantageous development of the entire area. 1. Minimum centerline horizontal curve radii shall be as follows: a. Parkway ...................... ............................... ............................500 feet b. Boulevard ................... ............................... ............................500 feet Design Standards ST -10 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 C. Industrial Street ....................................... ..............................3 00 feet d. Main Streets ........................................... ............................... 300 feet e. Avenues ...................... ............................... ............................300 feet T nM f. Minor Street ............... ............................... ............................150 feet g. Neighborhood Street .. ............................... ............................100 feet h. Lane ............................................................ .............................90 feet i. Alley ........................................................... .............................40 feet 2. Lesser radii maybe used only when sufficient evidence is presented to the City Engineer to show that radii described above are not practicable. Any deviations require specific City Engineer's approval. 3. Superelevations are required on curves for the design of all major streets and for any other street with a design speed above 25 miles per hour. B. Where necessary to give access to or permit satisfactory future subdivision of adjoining land, streets shall extend to the boundary of the property and resulting dead -end streets greater than 150 feet (measured from the projected curb or edge of pavement line of the cross street) shall have a temporary turnaround. t �'.V, STREET GRADES Design Standards ST -11 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 Minimum Stopping Minimum Length Sight Distance of Curve Regional /Major and 350 feet 200 feet Industrial Streets Transitional /Collector 200 feet 100 feet Design Standards ST -11 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 Streets Local Streets 100 feet 100 feet 8. Minimum cross -slope for all streets shall be 2 %. Maximum cross - slopes shall be 5% (offset crown may require tilt section, minimum 2% cross - slope). 9. Maximum cross - slopes in cul -de -sac bulbs shall be 5 %. �:'.VL INTERSECTIONS A. All streets entering upon any given street shall have their centerlines directly opposite each other or separated by at least 200 feet. B. All streets shall intersect at right angles, or along radial lines when the intersection is within a curve, and shall have at least 50 feet of centerline tangent adjacent to the intersection. C. Curb return radii: Industrial Boulevard, Parkway Transitional-: Main Street, Avenue Local Minor Neighborhood Street, Lane 3 5 feet 20 feet 20 feet 20 feet 20 feet At all intersections, the curb return radius to be utilized will be determined by the highest street classification ., A 15 feet radius is allowed on Local Roads with parking on bons tr eets. The street frontage area 15 feet on either side of the curb return shall be properly marked "No Parking". TYPICAL SECTIONS A. Typical sections for the improvement of streets and alleys shall be shown on the improvement plans. Curb and gutter sections, curb return radii, parking strip widths, and sidewalk widths may be modified where these improvements have been constructed in a portion of a block to other than the typical sections shown. However, any modifications require the specific approval of the City Engineer. Landscape strips on other roadways shall be consistent with the Street Tree Table and Section XI. `Tl "VIII. PAVEMENT DESIGN ........ ......... Design of the structural section for all streets shall be in accordance with the following criteria: A. Design pavement per Caltrans Hi hway Design Manual Chapter 610 and 630 using a 20 year desi n life. B. Traffic Index 3. In no instance will the T.I. be less than the following:. Major Arterial and Industrial a minimum T.I. of 10.0 Major ro» etor Collector and Minor Arterial a minimum T.I. of 10.0 Minor Collector a minimum T.I. of 8.0 Local (excludes roads w /commercial traffic /busses) a minimum T.I. of 7.0 4. For all street design, use Chart No. 2 (3 sheets), "Structural Design Chart for Flexible Pavements." C. Soils Reports 1. Resistance "R" Values a. A qualified Soils Engineer shall obtain sufficient soils samples within the proposed street construction to permit determination of the "R" Value of the various materials which lie immediately under the planned structural section. The cost of sampling and testing shall be at the owner's expense. Design Standards ST -13 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 b. The basement soil shall be tested according to California Test 301 "Method for Determination of the Resistance `R' Value of Treated and Untreated Bases, Sub - bases, and Basement Soils by the Stabilometer" in use by the California Department of Transportation, Transportation Laboratory. Design of the structural section for a particular street will normally be based on the lowest "R" Value material encountered. C. If the engineer elects to utilize an "R" Value of 5, then "R" Value tests will not be required. d. The owner's soil engineer shall submit to the City a Materials Report showing the location and elevation of sampling points, "R" Value data, and Expansion Index Tests. The owner's soils engineer may be required to make a field survey of soil conditions when rough subgrade has been cut to verify data presented in the Materials Report. The cost of any additional sampling and testing shall be at the owner's expense. 2. ive Expansive Soils a. Irrespective of the "R" Value used, an Expansion Index Test shall be required. b. A soil will be classified as expansive unless the Expansion Index is less than 50 as measured by ASTM D 4829. " In addition soils meeting all four of the following provisions shall be considered expansive. 1. Plasticity Index (PI) of 15 or greater, determined in accordance with ASTM D 4319. Design Standards ST -14 Volume 1 for Public Improvements Revised c pte ber 2 nn7 gfgMarch 2011 C. Lime treatment shall be a minimum of 18 inches thick and extend to the edge of the back of the curb at a minimum. D. Gravel Equivalents 1. Structural sections are to be determined from Chart No. 2 utilizing traffic indexes and known basement soil "R" Values. Gravel equivalents are to be converted into structural sections using gravel equivalent factors (Gf) for the various construction materials as shown on Chart No. 2. 2. All streets shall have a safety factor included in the design. Structural sections using aggregate base shall have the gravel equivalent of the asphalt concrete layer increased by 0.2 feet. E. Other Design Considerations 1. For roadwav section design the maximum R -value of lime treated soils Design Standards ST -15 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 F. Minimum Structural Section: In no instance shall the asphalt thickness in a structural section be less than as follows: Major Arterial and Industrial Streets 0.50 feet asphalt concrete Major Collector and Minor Arterial Streets 0.50 feet asphalt concrete Minor Collector Streets 0.42 feet asphalt concrete Local Streets 0.42 feet asphalt concrete G. Improvement Plan Notation 1. All improvement plans shall include the design "R" Value, Expansion Index, and the Traffic Index. This information shall be included in the typical section or in a note or table on the same sheet as the typical sections. REQUIREMENTS FOR EMERGENCY ACCESS DURING CONSTRUCTION A. Subgrade Conditions Summer Excavated and drained April 1 — Se tember 30 sub grade Winter 6 inches Class II AB October 1 —March 31 and fabric and projections. Design Standards ST -16 Volume 1 for Public Improvements Revised c opto,-.4ber 2 nn7 gfgMarch 2011 3. Subgrade defined as native soil at bottom of street section (base and paving), excavated to the approximate lines and grades shown on the project grading plan, and provided with a discharge for collected water, as approved by the City Engineer. 4. Base shall be Class II aggregate base or alternative recommended by the soils engineer and approved by the City Engineer. 5. Poor subgrade is defined as "R" Value of 10 or less. 6. Base shall be placed only on an unyielding excavated and drained subgrade, and to be compacted to at least 90% relative compaction. 7. Fabric to be a ground stabilization fabric such as Mirafi 60OX or equivalent. X. COMPLETION OF ROADWAYS XI. STREET TREES A. Acceptable street trees are listed in the Table Street Tree List. Only trees listed for use in streets shall be used in street planter strips or medians. B. No tree shall be placed in a planter strip more narrow than the dimension listed. The minimum distance from any paved surface shall be half the minimum planter strip dimension. Root barriers are required between all planters and paving. Trees placed behind a sidewalk shall be a minimum of 5 feet behind the sidewalk. C. No tree shall be placed in a tree well that is smaller than the dimension listed. Trees shall be centered within a planter strip. Where planters strips vary in size due to meandering sidewalks the most narrow planter strip dimension in 20 feet either side of the tree shall govern. ,we D. Only trees listed for use along streets shall be placed adi acent to streets and walkways. Trees listed for use in parking areas only shall not be used along .................. streets. E. All trees shall be a minimum of 12 feet high and have a minimum trunk diameter of 1 inch in a 15 gallon can or larger. Design Standards ST- for Public Improvements um...'-so': u MIN pm. LP 4s?, 1s ,:°•8. ,t 1 4 W Nr IjN, Oat. N 11 WZ7 J 0 cFAM BY 21 11H I.F-" iMR 7M . 17 E l a EM IW61 [061 18 ®r Pal IIZZi rly 1-M P NP, IN R5 14� t. - gp- i I Z" 1M �0- fx c) T z l. 2,�i -s ZrI., D w Z%4 Ko,:S,� i% F4 Design Standards ST -5 for Public Improvements Jv r 4j. y LM r6 toi -�fl rz ri Z b L 2r, � 'Ti : z A ig 9, 41 hRIPE."14, L 41r!; N ltA .1% X i� �71,25 VIN Imp A a. Fj Ira IY_ r 3 D 0 k, I r L 11. 9� I C1 Ul Al 1,.r, i �. , - ! A Ii IAA ".;I - * - "T H'i a, Ali , 11-1 5 B rip, m L I'A a- -L-11111 r�! 9. .1 fr 17- &1 L wi I L r - ; I m RN 90 Id y %, L M�.� k�le LIS I 1i: a A52-5i P.-I ;:�4 v ID ?.A F2 ;�t?' Dt 9q L '-i. 17 11; PDO p1 I I rr lin rill 1 L' Xli T11 Ull li, .1 M ;,r g ��'�'1Ij[J Ila to IN �A.ka jjy RL: C L A m 2. E 5 -E M ii - j:,j at, im IIII flr i 1LNvI,," A ;I 2 ILO P ?-; •IN,;! __A ii! GI ;t4. I -9 10 G P, - 91• L W. r re rc� V n p".ii 411 1, 1,4� 1;�'- 3p d A I Zi 9 Z� Sl%� d IIIIIIII C�Ljj �p wdwm ITp a a r, m P) IA. X., �1' U 4;� V-1 v 1 Si 2N r Q W. d E�2 ig im m v 1-12 M! P111 iLt FR A�:j Z ;3;r k,2 =.. �1 k, zs ki qu :J4 t" �Z; il 11 Ni AR IM d! 0 L_ R k 1, A C: T A K: Rf 34 II-A, .4h '�_il 0 rl I tier.} A' 'A F 'L4 CA V -u .4 J ! r ;,9-p Eel �i 165. 0A L!it P kLj N.- L.1� IN 1& B' '-.I Ff. r.% W L:2 z i L I W a fil, 01� Y a gw,L I 'L' V. M.%. �z �,kL ME r X_; 14T a. I il� r 7� 4I F 1, L' F r L rp L }. %jL 11 a.,. 'i, 14U:�: -3:0 L'. C! 717G.' r r! ?r,-.j -1; I;�,%i`-7_. U_.m.2iz�L� O'd :0 .1.1 L.t ILI lR;IL r; -r V.21 r �1 L.7 %r.:j [,r L 1� L3.�L, ii L� F w n m. K U Vn c-, -A r�- it;! . fiA L. ;j ;4 g Y U Ir �J �T c ir� r c.J. i, .4 1 5 w L- r. c; v tc le -;Ll;c %I r,--! �: rx X P: r. I L 13,1 �j %T n., �L% AY. Q :i il F a; .1� x•314 -.! N Nc F. .51 t.b 40 �1 HI N ',I� ;,hj g �1 C_r Ill W U S1. R Ii F; i31 WI! 'il E714 -i --Z -'A N Cl 6 N Y.- ."i u H I.EL P4 V P.5 I �:h I! LF 5 I�q r.1 i3 �7 0 FJ j;! �2 �F - rr - -. V - ;;:p - VA .6 V •PF r; L, R; 2% P- F: m u -e. 3 IN �A 7.4 ini:q �%, 5Nv� L: N iL r-I -n!l 09 �3r!r j L5 IV 11 i.1 -i rd r� L3 _-; L� ��!' 147; M L; I zo --17, F" ri �EN L% iv '4 Kip 1-� '91 .?Jr r��nt)j; ift I� I � E: L7 1- r1; �11 ' F1 IL Ir' X 11 ' . . 1 :,I�, rl - 4 : N Alb' P CZi H3 :1 '1.. 51 1 % , im: r a C . A2 Ki 51 %L," r - Z& M a Z I� y!i 1" - 1 r. F r - ; J Li Li -e e., � . in ;,n i L n � i m 1 r . - i b nu: .. 11 121 T., , 1 0 " ki PA 45 - 1 A d M Z '. 1 c ' U r F I i J -Jr 3 L-1 :5 1' JL r:,l .. - 11 - N -2 LA 1z �� LLi:%, :4 _ � L IIE, r4:,; -i,i ;t r I= Ld III r2 P'L3 T-! 25: 1-,, hit Lf Y C:! - 1 -2 '%LJ 9 -'1 iP I'- -j ;Ll L: . I LY I _-- ;v 1 1; 1 Ir:;.! Ir.. r�. P, k E., 1:3 T: v% I I . 12 1 _f 31 !x 12 vs n; :2 L.;4 _�el - '51. - m �7 1.3 me. ;i:i,. �I -, ;-j I:, Lj 1--i, } v q N -1 ?1 Tt 1) j Z;? z 1! zi -d P_ I-- Ri �-O: FJ ?I; F, 01 Fa Fm. �J. 14. :7 %r;-. 1-4 ti �re _e m ;A 14 ?2 E N W H Ui T C Ld r. 'F; 71: ri -i ir 1 '10 r LI S -t:; L f:. r I -�., r L i C.'I '-I '-I 'J Lk�_ _q j5U 1 N h 0 T u 0 r. r. 11 F i ir,91 I L t� rw L�l ej rc rL -f -711»1 =' I !A IL Y_ I - n I N e F: I ' - n n F3 ri; �j p; k� 4 1 N L, 91c zl i,. In . r N Ll :.,E 9! i; Fa :7. L'ZI LjI I L; tU 0 1i �J rj C" 1i �j 3.,P f-d ?I �I.0 • !4 9i P !� tZ 1! 5 M !!.L11 71 ij Ld S 51 id :�6.;'J 23 F, 4� L'�O „I II _!�X r-.'E '31 1� OS W..1 N 4 �j rL L� Lp. PT -% IV F%� i_- --j m pi � j-1 4 0 A 13 P�l V ig 1� r! V1 :- 1117. 3 u �j %- -4 r L ri E, Uli L -7 iir�:m�':� it j� L Z ;I L; Or�� jy -L' -1 p I r L r. zi m :R L.: - LL, re iq Pei ; a p I u L-i w id IF .5 P1 'Z 7-1 P-A b; -Y. Sr P rN qi H �I C� 12, 111 iii Ef f., :_I R IZ ln:i 'c R �L�e --i Ll 3 �j •ii U-� I Z I E r. I 1-r r; ---1 -2 t2 Z& N �4 :P F.2 :F4 N L3 �f 12'. r.93 U 43 M L3 '- r,' f I & R Z-7 4'1 11 IT-. L�-: ?i ''ll �L cl =1 ;.. N H �h D cl ff 2) in '�i 0 R ',I U! Fi Li 01 d. F j Ir kj 111 15 r - :5 rd Z.. r;, LY J L11 ;1 !4 71 P 411 1 ir i S Z7 ;:L'-A 0 1P.T li� 42 S '-' C I L.2 i ef 3P. �f 9 L% rr�, ri c 3 P ;g C_ yn .2. �.j I Uj u n T! q Llii �% PEA; t 1 !-4 i%! 1 4., Ll TI L.� ;. r.' -_S.S ITr .1 L:.:Pj -L;.Y.;F Lr, 11 ;i S:: ri.5 L..' D E� C FJ :!I R�. ; -3. 1,71 r! ,r r! L, 1_. _& i., I J� re I -J 4 IS 1 �ii ?: -12. %A rJ 0 �j I j 9% %•v 1; 11 U L_� ;121 �i U ..i. - I L; Ii Ij I... ir;i 5 a LU 11 rd U 11 all CIL IP 5:1 -f L� r, t: !.i% -cl �. r) U !,; LA L! laL,; t: Ti C. p,. rj :�j !RE ,. u i -ji r ;r ke, 'cr rr' -7,; ou AX ;.L".Lj n I A b n j! L.3 % L-1 : _�:P. % 'i V. iF:. ITI, F. PI El 'E F-5 t, P' n' rJ :6 'z� �._' ;:I ri: -d r�- Z F, K; 9. Lr� :�r �j e I,: ij LL M Y.,-%, ,m' r, el. (-, -Y? J12 ri :L- L, 1 Z Li 0 A�- 41 P-. I N 7 R i: -:ii 0 a L; i.n.;� r g :�4 re. L� _:L �j ;3 p Yj % L F.-, 3.r!p -,j 7' r 1 3e J- in, �I rL4 % %,a ;I UR ii L;, Q E L,*� a! ill, �� 11 _j 1 41. 1 CM jj pr� 'j: ! I Wg 12 � Ib.': �*'& L-LI 1`1 Ph. �'j f il.� 6c 7: m ;I ..in V '�J. 5� r: 1%: �� A ch 2 U 1 � L �j 61 z 6? Ll. I.q. q p La F- s, 7 'fl N ;-L �r 4 it , t Ij Ln 111 -Lr-,' Lr' P-1 Ur U f_4 L. 1. jJ L Lr. F, Ll M L, -F L! 'M �P.J LI W FL- tr '.;L Z! FL _�,p iL� r, FJ 15 P2 61 I-L.qj ;16 5. U -1 A, r. Yl _IL 1,! 7; --L: 7, u Y-T 1.�- ':r 0 t� A rl I :V I� r; ;3 V n 'I .-I )t �-4 G �j 1. 1 r' I L: �07 I I r 61 Ij 'A 14 -1 Z a ;,I X. Iz, t t U IR 1, -1 jE I LC el Lr r� r�. L r; r, Lr_ P Li U I u T.r ill i; :� :,r, 111 L, Cl I I r. p I. r Fr, -1 M le; Ll I i �L' E7 1 V W. I a L..-;j 1: :u i... Z J_ �d n Ad 1"7 U. Ij%qiJ,573TI L� �JAI` L. h c n in i.�et a I , L-; rS in r- L,% 1.1 ml ri I T M -I ra n h! I, it I L% I p% t� rI -4 rr, p !I r. Zi •Ti mc d; r.1 m I J, i M. U 'L I I- ; i . ri 1, p jr. !7i t; 5! ;1 r, :!, IC I; �t I.! 0_1 T U r. -,I -j E.1 • u :j. e_, iiF F; R F I t! �1 7. Li f! P'_ FA I` F :r. t' A ;9 �J T ri: r,7-16: 9, :; 7r L-, tl':! L2R r,.. a 31 D 13 F! Ti Ot 7- -- -.L.F i? 72 P P X t4 1.1. Jr 1_1 I L1. F. r_1 Ij IL; -.. Ej LI I �.j "I q V. ;L.._ I A: ti r- ;3 L 11!6. rg V,: r, -, �, e: ri WL, C, K r., I.' Pi II F, 5 X5 11. or -- ki 0 Tr~ bs - r. JIP i �Z L11 F4 ;j f. ILI F.! !j Lu r- Tj a� -.7 Z71 m 0 C D G ;J -3_1 [i P, 3 1 -',;' C F.- 3 F3;.;;�; '11 EL F..L 0. h: '_ '414 1�'b`]A'.qjI' !Xj J).; i', I r •0 i:4 U ri �-4 p - T:� LE �'! L� 9� c! k; I N LI q) P,'�3 0 61 1 ZL %,A I rz -!c - .: 7 r % i 7. L! i) L .. i PLI I ;IJ R, - j • E3 I 1 0 ri F! 57'. U- -5 �j P 'r$ ;3 :1 I.r -L'M L -.7 t F �v Ls r3 ,_ L, IL Iii =3 ig ;k .0 • 7 p ..i; I :j Uj k; -� ' ' -. L: % j "I _I 11 '?,' j�. �. Z..j :1. 4 tj' !71, r i i •'A rj r., I! z - J.jZJ L! j W i J 6 LA a �- T. E u P, I; el. 0 ..: L! 1, pi z' ri A: Cd 1; �ri _ I �, ?i� , • I r L':_� LJ r% _? Ff 51 r.! I-% •q V A% 41 rj m U U i�. ?I �-u ;?. P !7� n P. !i -j tj LJ rill -6 IL, r, f; L.; v Oz V. L4 r�I S, r,, 0 " n OR �: P r. I I-, U �1 F-! Id U i 0 Vi :.- P1 M !Q �,n rk ej r-- -6 L Y� _m: IL' V. 51 rc! TE f-. 1� yp -j L� r�;,; f: r, i m -7 =1 Li j 1:� F, �P t 1II if K L3 I.' L . L� _,i e, I.;j 11 1 q., ,4 F.- -LIE: p. t] 14 1; 1 L: �I;r'U WL4'1! C. IR! d�!e �2 6 1, I� Cr imli ji L: Ik (?:. r.1 g; �� ig L, p Fj 7A M.. W P '1 4% •0 -i 'N U. kq. r.,.- Ll U Ik -�J •- - �1 a P. 91. JI r, ;T Q 2: 10. r ! p e N y. r- I rJ B 17- L L,! r% f-. 46 :4 I-A V: r. �7 Z�: �E rJ �j �-L:g ��j :,; j! L=: D; I!: Ii! C. E- 2% �_ k.- r4 ;j rd L� �-.k L3.!I F; VI L, 'N" 1.1 "1 J 7! 13 v (I in 44 %7 E L 1! 6' - - C: 113 T1 f.; L F i%4 'j Er..: 'r%l .4 LI a� �E 1'. S �,2 -1 �j 'L-:� F2 j I • j2 il: 1111 r; :r i 1;4 T. e: tj i to ftL� PL r� v r ir. 4 .2L P; .1 - JI L. M N Fr! J! Li rj . L� %j i.! in Ij �,j -L 0., r, . 1 Nr 'c R' �r. .g ff3 I w- ;3 ;I t j Ac;l 1H yl r a rl' Ll re t, N '%7 �l -il -N 'A A . il 1�,�,:J f: T. ri: U !A tq r. 0 0 !9 4 9 1�' ?J .-I Li -I P1 11; 'r' �I C." C. L: aa L5 4� U ?rl �I N r-i 4k 'it _1 '11. Ji F. :21 s � I 111 N t� -2 '7: 71"1 A N 'd 4 Fj 14 ; ). r� T, 'I rq i� E,.;' L: 0 ': �Lj IZ 3; IL-� !) ; !.6 w! t; ro : " �1 YI ;q �t p M !J 71 b 4 A r LU 0 T. kj 1 pe. r 5 p J, -F, 9 ri�. C i� I r j r 1 1,: �: IF, K 1,1 _. r; � i r d Lk 'es j) 4 E? 64 :1 '_15 Li M -,43 E71 1 L �; U r. I V D N il' , VI L� N r. '.. U 6 4 ft N 1 -2 J. e! 1-i rj L: �f. L I v, k,, f:, bc rL: x ii a N k, k I fri u. 11; ?:J .1 2! -1: 0_� -ji -1 e. k% I LI 01 IV 1'. ki W 1;711 ... a rd Lu It s U 'e3 j Lc in K:. V. q C,. W rg id W Ln W.R,;; -:i i.j t;- a%;.-.1 a:.. n, m r:: 7- c Al'; x 6; Iz 1 •-y--- '-- - - f.;V - �A F Of A k 44@ -)t� wy V -Ii" - A � - ;,_Lf c I _- .. .. - - - a'l l-N . J 0. P P w I -r-r;l r rAVA t a a� Q t a a� Q t a a� Q 3. r T i3 Ir 114- r I 14 e� L � .1 r 4% -1 % --j r L3 1 9 % r :6 :V. T ti r rr NNN 1 11 1 1 1 or I-N r F A, Nu I I 13:5 IS, m I IN I IL I I In 1: j Ar TEMMOO I e 9'a I.M L I N, L I 1 II -1 6 :;7 1 rj ilLr! 1 0: L . Ir % I IN A r-r =-9 ?dr FF FRA lu ill Ill I A ill i - - id �� �� � JEW r L J JU ft )Mr r NO -,,.NIIIIIIII L IMF- A AU IN r r 1 1 ; 1• Z 1}' 1'111y ■ ■.■-- .,11y,'` F i _ F�j 11� Y Y •• % IN I F1 9. A mI R M 1: 111 -M % �W- rl L% % r L % :116. r 1% r r .15 a rl rz t - % % % L NN.r I 61, WL 41-3 tLq A %1, 1 N: 1. a M r r IL r • L k i L -I.- is -' C3 r A:J, 1— 2 L :1 91 r -1 '1 NANA 11- 11.d _V __ :�,. � 'L.- -N, % — W2 I.0 L gi. r N. 29 L .9 L F I $1 r b16 .0 16 r $ T" L r • IL r -d -P , 19i 7 r: 7L ..e., • rj L NM� e J1, r AF-* 6 rr of $ q9" :r 4, AL 4 ON 9 'A. e r% F x IN. lu u 61 romlu 10 1 0 0 JAN _I L I J 3% I el A 9 if ' a MN 91 ■ A r • 9 .9 9 9 9 Ic 9P, d I L w ro % VIII . VIII I'll �., - ��III d L I CL 4 iL .9e KU, I II 111 Ili I I�� r_� W, L L MML Lt L INN L P, A ;t Lr.! 4 L A !:4 • :L it :L +,mf 1. ==3c 9c r a • r 4L Y,6 �--1 r A %: m1rr.L a _e n%& V 6 E rr • I r % . .1 r • .11g IV lut", 'r in' 6 _.�l 6: 6F Y % L 27 r: I C ':a Lr.T !':6 6 % 6 Lz rk • r, Pk 7: r L A :L % J.- A. ;r L 7' 1 -T� Lj 2 Kr 4. r L L T, r % L LC I z 4� Y IL I I L L r mm! I Ir !1M IMMEN Ut I I Jill I ILI F4 PrR r M 'r R )- ` jL. L 11 F ILI i Lj v r NNNNJ ML 9000000000000000=0 T %M ■ Li Pr r % Y� 7L 0 ZE Fir =9. t! L 9P, U. K2 p tis f ICI l�� � Ar No L� M P% IC!6 % :16-1 01 MEME I r Wod Yr-Lj . %* re rA —N. LI-4 F p" L IL L er mmmm====L1LLr1�- IL NE I 1i , �1f .I i ' ID r I LL 9L: -1 L j Lj Lm� IMMEMEMEM I r .j F. % LI 4ro le-altrk -9 t a a� Q Flange adapter Underground socket pipe clamp 0 Pipe bedding 3 Clear k, '4 -4 ° Conc. ier block ° P a• » ° a 3'- 0 Min a• 7 /1 R =4" Min ELEVATION Bearing area against 6" Min ° undisturbed ground ° .a (See table below) A Flange x push —on valve \ \ \ \ \ \ \ \ \\ 0 o Flange x mech. All flange tee ° • joint valve o o a• 0 0 ° .° . >_ Tie rods o °• ° a A' ° .a ° .d Mech. joint plug Concrete thrust tapped for blow —off. block (See table below) Concrete shall extend at least PLAN to the undisturbed earth at both sides of trench. MINIMUM DIMENSIONS PIPE TIE HARNESS THRUST q. CITY OF ROHNERT PARK q. - q. q. 1 1 HARNESS INSTALLATION ir " FOR FLANGE FITTINGS * Bearing area below grade of pipe against SCALE: NONE DATE: OCTOBER 2010 undisturbed ground. Approved: ** Bearing area against undisturbed ground. STD - 851 SIZE RODS BLOCK* A BLOCK ** 6" 5 8 " 4 S Ft. 2' 4 S Ft. 8" 3 4" 7 S Ft. 3' 7 S Ft. 12 " 1 -1 8 ' 15 S Ft., 3' 15 S Ft . OVER 12 BY DESIGN ENGINEER BEND TYPICAL CONC. BLOCKING SHOWN IN PERSPECTIVE. TYPICAL BEND TEE OFFSET NOTES: 1. To use this standard, a geotechnical engineer shall confirm the soil bearing capacity or a value of 1000 P.S.F. shall be used. 2. Safe bearing load of soil for horizontal thrust shall not be exceeded. 3. Concrete blocking, cast —in— place, to extend from bells of fittings to undisturbed soil and entire bearing area must be against undisturbed soil. 4. In using the Thrust Blocking Table below, the Design Engineer shall specify thrust blocking requirements for all other soil bearing conditions. 5. For plugged leg(s) of tee or cross use harness type blocking as shown on STD. 852 and concrete blocking indicated in table below. 6. Restrained joint pipe may be substituted, with calculations, in lieu of thrust blocks. MIN. REQ'D BEARING AREA IN SQ. FT. PER 100 P.S.I. TEST PRESSURE* PIPE SIZE SOIL BEARING CAPACITY(PSF) TEES & DEAD ENDS 900 BENDS 450 BENDS 22-1/20 BENDS 6" 1000 4 6 3 2 8" 1000 7 10 5 3 12" 1000 16 22 12 6 * MULTIPLY N0. IN TABLE BY TEST PRESSURE & DIVIDE BY 100 For pipes greater than 12 ", Design Engineer must submit calculations to size concrete thrust blocks. N U U O O � N L L N O � P7 O � N +' O U LO CO i C Q O O N n a -0 N O c: N 0 L •c: � O N-0 c/) N p 0 _ O U N � U � I �o Z*t _ (n 1 U 0 I • I DI ��I Q V N Do I �L 0 cLN I � 00 v I I ._ C^ o •— U cn v -0 N N _ U a .� I L L N (n O W C O I O 1 + a U N 0 O c Z U O I O U -0 I (� c: (� O O -0 N I I C)l ° v - - — -0 - I •- .L U > `� V w I O v ✓ W L. o Q (A (V U N O N L _ I I _ ° - •O •� — 4-1 o L O ;� N I I � E 0� E i I I ° 0 •_� ° Liz 0 I I'+J o 4-j O a -0 U a 0 -0 a E I U O •° ° Q ° Q � a) a) v , Q >, a - • v -0 - (n 0 O w Q (n O Q cn 0 I F- 0 0 v D ° p v v z N I`7 In CD .0 0 E L CITY OF ROHNERT PARK 0 WATER MAIN OVER STRUCTURE I I w SCALE: NONE DATE: OCTOBER 2010 Approved: STD. _ 856 cn O O c- -0 U U) N (n J N > J 0 J O X 0 -0 0 -0 -y -0 O Q) Q U Q) -0 Q N Q O 0 � O - 0 O O Q -0 -1-j Q (1) Q cn Q � Q O N Q O 0 c D 4- Q z Q U O U O < Q O Q Q W V) -0 0 w -0 U Q) Q I L -0 O L 4-1 c: L U 4 Z 0 Q) N Q) 0 •� Q) O W O w VJ O m� U N 0 U 2 � D� O � � � U V) Q ° a !O (.0 e O w of N c: O U � L L N a s I U GL >� v �7' � O O (n N-0 � U O>1 (D a_ U C QO U c > 4, v O 0 O Q U U U) -0 U 0 \� Q) ++ O +' 0 +, , O ^ w - 4- O U +� E 4-j CD Of O '� U 0 W -0 L- 0 V V U N O N -c- 0 0 -#-j O — -0 a) -I--, C. (n 0 :3 L.- E 0- w > _ c: b _ 4-j — > U ++ U L Q) -0 O 0 0 •- s w L 1 ' 4-j LL- 0 - al. Q � Q) O •� U 0 0 -0 ' U) O O Q) 4- O (n +O-+ Q) Q) I- _ ° W q- O 0 0 � 00 > ° + 48 co �\ 0-0 _ � X Q) 0 cn CITY 0 F ROHNERT PARK co Q) Q e 0 ry L- L v o . � Q) U �� F- O FIRE HYDRANT and LATERAL �' m c- °� - E 0 SCALE: NONE DATE: OCTOBER 2010 ai 0 Approved: ch a- 0 0 � STD. - 857 Page 1 of 2 Remove exi prior to cor I X AOI I I AO I i NIOTF_c - Max. 10' for final tie —in by Contractor under City inspection. proved 6" double check valve Double gate valve assembly OS &Y Shut —off valves Reducer if J I%,II1VW, u, y ..VV.J ,y I v 1, required. sufficient for test pressure or alternate harness blocking at both ends. - iron ings ;r as !d. 1. This assembly shall be installed when combustible materials will be stored or constructed on —site prior to acceptance of the on —site water main by the City. Fire flow & access must be satisfactory to the City Fire Department. 2. The Contractor shall furnish the meter and have the meter and double check valve tested and certified on —site prior to activating the system. The contractor is responsible for any fees and charges incurred. 3. The Contractor shall make final tie —in under the inspection of a City Public Works inspector. Inspection fees must be paid prior to scheduling tie —in. 4. Meters to be gallon reading type only. 5. Clearance to be 12" min. above finished grade or 6" above the inundation level, whichever is higher. 6. Fire lines shall be flushed per City Standard Specifications and adequate fire flow provided prior to combustible materials being stored or construction beginning on site. 7. The meter shall be installed with proper lengths of pipe both upstream and down stream of the meter. See manufacturers specifications for determining pipe length(s). 8. A Utility Billing account shall be opened with City prior to flowing water through meter. Precast concrete meter box set flush with surface of ground. 2' max. 6" min. a APPROVED BOX & COVER 4. (See Engineer's Approved List) Tracer wire: blue insulation, #12 solid copper w/2 " -3" pigtail Threaded brass pipe,_ ripe bedding 3 Clear R =4" 3' -0" Min. Min. Bearing area against 6" Min undisturbed ground (See Table Below) A ELEVATION Tie rods — (see Table below) -D - -D - 4%t> 4�! NEW MAIN - ,/X .D - // 4 Angle iron — 4% (see Table below & Note 1) Concrete shall extend at least to the undisturbed earth at both sides of trench. PLAN — 2" or 3" Square head plastic plug— finger tight 2" or 3" Brass ball valve (See Engineer's Approved List) Set valve operator parallel to curb. Set valve grade above bottom of box and a min. 2" below lid. Redwood support Plug tapped on center for iron pipe size thread. (See Note 1) NOTES 1. For 6" & 8" mains, M.J. plugs or caps with dilly lugs and 2" center tap may be used in lieu of angle iron. Install angle iron off — center to accomodate center tap. 2. Blow —off shall not be installed within the traveled way. If main ends within street area, blow —off to be extended to area outside of traveled way and installed as shown above. MINIMUM DIMENSIONS PIPE SIZE TIE RODS ANGLE IRON BEARING AREA A SIZE B. 0. 6" 5/8 of 3 11 x3 "x 1 4" * 4 S q. Ft. 2 2" 8" 3 4" 3 1/2 "x3 "x 1 /4 "* 7 S . Ft. 3' 2" 12" 1 -1 8' 4"x3 "x 1 2" 15 S . Ft. 3' 3" OVER R BY THE DESIGN ENGINEER 3" * (see note 1) Valve box & riser. (See Std. 877) Tapping sleeve or `• {= hydrant tee , O 8- ,; l;:, r - Concrete thrust Block (See Std. 854) I Approved Box & Cover (See Engineer's Approved List) Precast concrete meter box set flush with surface of ground or traveled way. °A IN Tracer wire: blue insulation, #12 solid copper Gate valve (P.V.C. pipe only) (See Std. 877) P.V.C. or D.I. Pipe Redwood blocking as required — Concrete pier 2" or 3" Square head 3 " -10" plastic plug finger tight 2" or 3" Brass ball valve. (See Engineer's Approved List) J Flange w /2" or 3" center tap. oil, block to 'dl�d j extend to undisturbed ground 3'x3'x6" min. Full length D.I. spool length as °Q required o` (See note 1) 4% .446 NOTES 1. Restrained joints are required for all new construction from gate valve to 90° bend. Thrust blocks are only required where existing services are being modified and restrained joints are not used. 2. Blowoff piping to be the same size as the main. Full size 8" or 12" blowoff wa ter m Gin ML F/C Cu I —de —Sac wa ter m Gin F/C --\ Th ru — Street Blind Flange Blind Flange E/P or F/C water main qW F/C Full size blowoff Deadend Street Full size blowoff ERT - UNIT SHALL BE SUPPORTED IN AN APPROVED BRACKET IN THE METER BOX. TOP OF THE ERT SHALL BE WITHIN 3 -1/4" OF THE TOP OF BOX. CURB & GUTTER A FA O 1" STRAIGHT METER COUPLING OR 1 -1/2" METER FLANGE BRASS STREET ELL CHECK VALVE BRASS CLOSE NIPPLE FIRE SUPPLY (1" MIN.) DOMESTIC SUPPLY (3/4" MIN.) n ANGLE BALL VALVE THREADED BRASS TEE DISC METER CITY INSTALLED CABLE AND TAG. TAG SHALL READ "DO NOT SHUT OFF ". ANGLE BALL METER VALVE IN -LINE CONNECTOR WITH SECURITY SEAL 1�1 - 14" CONCRETE METER BOX W/ COMPOSITE COVER STAMP 4" "W" ON FACE OF CURB / a IF - / a 10" DOMESTIC SUPPLY CONNECT TRACER WIRE TO TRACER WIRE ON /-- MAIN. IN THE ABSENSE OF A MAIN TRACER z w FIRE SUPPLY \���-_____________ WIRE WRAP TRACER WIRE AROUND MAIN. POLYETHYLENE TUBING, N U CLASS 200, SDR 9 (CTS) 3/4" TRACER WIRE: BLUE #12 SOLID (NO COUPLINGS) DRAIN ROCK COPPER (4" MIN.) DOMESTIC SUPPLY LINE AND MAINTAIN POSITIVE SLOPE-------"'- LOPE FIRE SUPPLY LINE SHALL MEET BUILDING DEPARTMENT AND FIRE DEPARTMENT REQUIREMENTS AS APPLICABLE, AND SHALL CORPORATION STOP EXTEND MIN. OF 12" BEYOND BOX AND SIDEWALK. WATER MAIN SERVICE SADDLE CITY MAINTAINED PRIVATE OWNER MAINTAINED NOTES 1. THIS STANDARD APPLIES TO COMMERCIAL AND RESIDENTIAL SERVICES WHICH WHICH REQUIRE OR PROVIDE FIRE SPRINKLER SERVICE. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF THE METER BOX WITH PERMANENT MARKER BEFORE CITY WILL ACTIVATE SERVICE. 3. OLD METER TO BE DELIVERED TO CORP. YARD OF PUBLIC WORKS DEPT. FOR FINAL READING. METER SHALL BE FURNISHED AND SET BY CONTRACTOR. PROVIDE ERT AND TRANSMITTING REGISTER WITH 5' LEAD. 4. SERVICE LATERAL AND BUILDING SUPPLY LINES SHALL BE INSTALLED UNDER BOX, KNOCKOUTS SHALL NOT BE USED AND BE GROUTED. 5. WATER SERVICE TO BE LOCATED IN MIDDLE THIRD OF LOT AND OUTSIDE OF DRIVEWAY APPROACH UNLESS OTHERWISE NOTED ON PLANS. 6. SERVICE LATERAL BEDDING (PEA GRAVEL) SHALL BE PLACED PRIOR TO INSTALLATION OF POLYETHYLENE TUBING. 7. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEERS LIST OF APPROVED MATERIALS.. 8. HYDRAULIC CALCULATIONS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13D. HYDRANT FLOW DATA SHALL BE BASED ON ACTUAL HYDRANT FLOW TEST DATA AS PROVIDED BY THE CITY FIRE DEPARTMENT. CALCULATIONS ARE SUBJECT TO FIRE SERVICES DIVISION APPROVAL. 9. SERVICE LATERALS OF 1 -1/2" (MINIMUM) SIZE SHALL BE REQUIRED FOR DUAL METER INSTALLATIONS. 10. ALL COMPRESSION FITTINGS SHALL HAVE STAINLESS STEEL INSERTS. 11. NO FENCING SHALL BE INSTALL BETWEEN STREET AND METER BOX. 12. THE METER SHALL BE INSTALLED WITH PROPER LENGTHS OF PIPE BOTH UPSTREAM AND DOWN STREAM OF THE METER SEE MANUFACTURERS SPECIFICATIONS FOR DETERMINING PIPE LENGTH(S). 13. A UTILITY BILLING ACCOUNT SHALL BE OPENED WITH CITY PRIOR TO FLOWING WATER THROUGH METER. RETROFIT NOTES 1. PROVIDE HYDRAULIC CALCULATIONS VERIFYING AVAILABLE PRESSURE AND FLOW PRIOR TO MODIFICATIONS FOR FIRE SERVICE RETROFITS. 2. A SEPARATE FIRE SERVICE SHALL BE INSTALLED (PER OTHER CITY STANDARDS) WHEN CALCULATIONS SHOW FIRE NOTES 1. THIS STANDARD APPLIES TO COMMERCIAL OR RESIDENTIAL SERVICES 12. THE METER SHALL BE INSTALLED WITH PROPER LENGTHS OF PIPE BOTH WHICH HAVE A SEPARATE FIRE SPRINKLER SYSTEM. UPSTREAM AND DOWN STREAM OF THE METER SEE MANUFACTURERS ERT - UNIT SHALL BE SUPPORTED IN AN APPROVED 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT BRACKET HUNG IN THE METER BOX. TOP OF THE MARKER BEFORE CITY WILL ACTIVATE SERVICE. FLOWING WATER THROUGH METER. 3. METER SHALL BE FURNISHED AND SET BY CONTRACTOR. PROVIDE ERT ERT SHALL BE WITHIN 3 -1/4" OF THE TOP OF BOX. AND TRANSMITTING REGISTER WITH 5' LEAD. 4. SERVICE LATERAL AND BUILDING SUPPLY LINES SHALL BE INSTALLED IN -LINE CONNECTOR WITH SECURITY SEAL UNDER BOX; KNOCKOUTS SHALL NOT BE USED. KNOCKOUTS SHALL BE 12" -14" CONCRETE METER BOX WITH COMPOSITE COVER STAMP 4" "W" ON FACE OF CURB / p DISC METER, CENTERED IN BOX p 6. SERVICE LATERAL BEDDING (PEA GRAVEL) SHALL BE PLACED PRIOR TO INSTALLATION OF POLYETHYLENE TUBING. 1011 7. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 8. SERVICE LATERALS SHALL BE AT LEAST ONE SIZE LARGER THAN THE LARGEST METER BEING INSTALLED FOR DUAL SERVICE INSTALLATIONS. 9. ALL COMPRESSION FITTINGS SHALL HAVE STAINLESS STEEL INSERTS. CITY OF ROHNERT PAR 10. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN, IN ABSENCE OF TRACER WIRE ON THE MAIN WRAP TRACER WIRE AROUND WATER SERVICE F5/811 MAIN. `b o o0 00°00 00�$� z w X 3/411, 1 " & 1-1 /2" DISC M ETE R%'-: \� 3 /4'LMIN1 - -- -- - -- POLYETHYLENE TUBING, DOMESTIC SUPPLY LINE TO CLASS 200, SDR 9, CTS N BUILDING TO MEET BUILDING (NO COUPLINGS) DEPARTMENT REQUIREMENTS TRACER WIRE: ANGLE BALL METER VALVE BLUE #12 SOLID o COPPER MAINTAIN POSITIVE SLOPE 3/4" DRAIN ROCK (4" MIN.) CORPORATION STOP WATER MAIN SERVICE SADDLE PUBLIC PRIVATE (INCLUDING MAINTENANCE RESPONSIBILITY) NOTES 1. THIS STANDARD APPLIES TO COMMERCIAL OR RESIDENTIAL SERVICES 12. THE METER SHALL BE INSTALLED WITH PROPER LENGTHS OF PIPE BOTH WHICH HAVE A SEPARATE FIRE SPRINKLER SYSTEM. UPSTREAM AND DOWN STREAM OF THE METER SEE MANUFACTURERS SPECIFICATIONS FOR DETERMINING PIPE LENGTH(S). 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT 13. A UTILITY BILLING ACCOUNT SHALL BE OPENED WITH CITY PRIOR TO MARKER BEFORE CITY WILL ACTIVATE SERVICE. FLOWING WATER THROUGH METER. 3. METER SHALL BE FURNISHED AND SET BY CONTRACTOR. PROVIDE ERT AND TRANSMITTING REGISTER WITH 5' LEAD. 4. SERVICE LATERAL AND BUILDING SUPPLY LINES SHALL BE INSTALLED UNDER BOX; KNOCKOUTS SHALL NOT BE USED. KNOCKOUTS SHALL BE GROUTED 5. WATER SERVICE TO BE LOCATED IN MIDDLE THIRD OF LOT AND OUTSIDE OF DRIVEWAY APPROACH UNLESS OTHERWISE NOTED ON PLANS. 6. SERVICE LATERAL BEDDING (PEA GRAVEL) SHALL BE PLACED PRIOR TO INSTALLATION OF POLYETHYLENE TUBING. 7. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 8. SERVICE LATERALS SHALL BE AT LEAST ONE SIZE LARGER THAN THE LARGEST METER BEING INSTALLED FOR DUAL SERVICE INSTALLATIONS. 9. ALL COMPRESSION FITTINGS SHALL HAVE STAINLESS STEEL INSERTS. CITY OF ROHNERT PAR 10. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN, IN ABSENCE OF TRACER WIRE ON THE MAIN WRAP TRACER WIRE AROUND WATER SERVICE F5/811 MAIN. X 3/411, 1 " & 1-1 /2" DISC M ETE R%'-: 11. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. A A --t 5' MIN. PE WATER SERVICE PLAN VIEW FACE OF CURB 3/4" DRAIN ROCK (4" MII� PE WATER SERX, SEWER LATERAL SECTION A -A SINGLE METER BOX INSTALLATION FOR DUAL 3/4" OR 1" MANIFOLD IN -LINE CONNECTOR WITH SECURITY SEAL WATER METER METER BOX AND LID F�OF G� O POLYETHYLENE TUBING CLASS 200, SDR9 CTS (NO COUPLINGS) NOTES 1. THIS STANDARD APPLIES TO COMMERCIAL SERVICES WITH A SEPARATE FIRE SERVICE OR RESIDENTIAL SERVICES WITHOUT A FIRE SPRINKLER SYSTEM. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE CITY WILL ACTIVATE SERVICE. 3. METER SHALL BE FURNISHED AND SET BY CONTRACTOR. PROVIDE ERT AND TRANSMITTING REGISTER WITH 5' LEAD. 4. SERVICE LATERAL AND BUILDING SUPPLY LINES SHALL BE INSTALLED UNDER BOX; KNOCKOUTS SHALL NOT BE USED. KNOCKOUTS SHALL BE GROUTED. BUILDING SUPPLY LINES SHALL EXTEND 12" BEYOND BOX AND SIDEWALK. 5. WATER SERVICE TO BE LOCATED IN MIDDLE THIRD OF LOT AND OUTSIDE OF DRIVEWAY APPROACH UNLESS OTHERWISE NOTED ON PLANS. 6. SERVICE LATERAL BEDDING (PEA GRAVEL) SHALL BE PLACED PRIOR TO INSTALLATION OF POLYETHYLENE TUBING. 7. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. fto .E METER VALVE ERT - UNIT SHALL BE SUPPORTED IN AN APPROVED BRACKET HUNG IN THE METER BOX. TOP OF THE ERT SHALL BE WITHIN 3 -1/4" OF THE TOP OF BOX. ADDRESS (SEE NOTE 2) BUILDING SUPPLY LINES TO BE INSTALLED PARALLEL TO EACH OTHER AND PERPENDICULAR TO CURB LINE. ANGLE METER BALL VALVE. SET VALVES MIN. OF 2" CLEAR FROM BOX AT EACH END. U- BRANCH TRACER WIRE BLUE #12 SOLID COPPER 8. SERVICE LATERALS SHALL BE AT LEAST ONE SIZE LARGER THAN THE LARGEST METER BEING INSTALLED FOR DUAL SERVICE INSTALLATIONS. 9. ALL COMPRESSION FITTINGS SHALL HAVE STAINLESS STEEL INSERTS. 10. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN, IN ABSENCE OF TRACER WIRE ON THE MAIN WRAP TRACER WIRE AROUND MAIN. 11. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. 12. FOR LATERAL INSTALLATION SEE STANDARD 863A. 13. FOR DUAL 1" METERS USE 1 1/2" PE TUBING FOR DUAL 5/8 "x3/4" METERS USE 1" PE TUBING. Of X w O> m0 Of U wW WH (n 20 w O w Of U) U = U Z w z �� 0(-) w w cn z J � z� n 0 x Lwm0 > ry, m aw0 zo W ateW Z LL O LL Ww0 H r = Of O a W ' M Z � 0 2 Lu mo J w Q z in _ � J (n p J ~ _ Z � � D Y LLI U ry, �aW wmo X � m w Z W 2i LLI U)� oz w NU ti ti ry 00 w ' �o o� z� a U 00 m� wry >w J LL a W > ry O U O p X U) W Wz~ O z 0 w m J W L Co Of W W L 0 2 Of H IL OW �C) (n gzz 00 mow < W J m ::) W W ~ D 0 W a- w W w 0 =W ~w N co w a co W U_ w co Z a ry w H a U) U) a ry m W J x N Z _ w m z Q O O >- 6 w w z w LLI _ W U) J = J () LU wv J J a m - N Z W — U W ~ a ~ LLI m> = U) r Of cD z ax < C� J J W U) O W CO Z z w LL O = w U� O v 0 m z a W :E w a- of Z 0 �< LU U Of w w cn z O LL w zz Y LL H 0 H 2 i J Q a X U Z z W a U LL — _ m O U � m ao O z z �� w D Q m a o z� �U) 0 Z vi O LUU U W a � D z z u X w m Z cn C) Of LL w LL � w O LL 0 0 o a °m 0 a� � O Oa U U J zzm W cn 0 > D w CO co J Q w m o w C/) Wz WU � 7- a cn W Z Z ? J O Q 0 W LLB U) N r Q w J H Cn LU a p >_?� w a U Y za z m = U 0 z > 00 W� C/) Jo maw U) O i �� a W �Z Zo W U w °° 2~ J J W U H w w 0 2 W w Z a J a w > Z a = LL O J W Z U— z U' N U Z < O U = c= 2 LU z J �_ z O Cl) L m w a g LLI > w= U > LU m w LU LL J p Z W = H z 0 mz �a a = w > a �= w� aW a� a O LL w Z Q �o pz O J �J a- J U) �� �� O O Cl) o m z 0 n a `. mom z� pW z J Q� DJ o cn 0 �a �wX �O LL —m cry o 2 Z H Jm 5 U za a � z W �O W m pLn ~ Z U)2 J ma U >o H �� z 0 Q�> o� wo Of w wLL zU) wQ wa w m m �wJ JU) z O D m J m0 J au, J H U) J �o a LLI J_ w wQ> DO m W 2 O w 0 p p � 5 W a 0 W Of W � J a H (nZ X H(Yj p JW ° �— H� IL z w WUW >n aLL p� U) w m� w Y co 0a U 0 w z O U o W a U z >— Y W U > � z o W Y O LL LLI W w Z a W U) z 0 Cn W H w J LLI w � m a � W U LL H Z p OU � O Z a r In N Cl) M 4 U) D Ln w m CO o f r` ZZ 00 0 m O r cn r r U) U) a ry m W J x N Z STAMP 4" "W" ON FACE OF CURB SIDEWALK - TRACER WIRE: BLUE INSULATION, #12 SOLID COPPER D O O O3 O 0 0 JO 4 6 WATER MAIN NO. ITEM DESCRIPTION QTY. 1 SERVICE SADDLE 1 2 2" X 4" BRASS NIPPLE THREADED 3 3 2" GATE VALVE THREADED 3 4 2" BRASS ADAPTER MIP X COMPRESSION 1 5 2" CTS POLYETHYLENE TUBING CLASS 200 SDR 9 NO COUPLINGS 1 6 2" BRASS ELL COMP. X THREAD 1 7 2" BRASS PIPE THREADED LENGTH AS NECESSARY 1 8 2" BRASS STREET ELL. STANDARD ELL FOR NO BYPASS 1 9 2" X 1" BRASS TEE 2 10 2" X 24" BRASS PIPE THREADED 1 11 2" - 2 BOLT THREADED METER FLANGE 1 12 2" PLATE STRAINER 1 13 2" COMPOUND METER W/ 2 TRANSMITTING REGISTERS AND 2 ERTS 1 14 2" FLEXIBLE METER COUPLING 1 15 2" BRASS PIPE THREAD X PE 24" MIN. LENGTH 1 16 1" X 8" BRASS NIPPLE THREADED 2 17 1" BRASS ELL THREADED 2 18 1" BRASS PIPE THREADED LENGTH AS NECESSARY 1 19 1 1" BRASS BALL VALVE WITH STOPS AND LOCKWINGS 1 20 RASS PIPE THREADED X PE LENGTH AS NECESSARY 2 21 t1"2-BOLT DRESSER 1 4' MAX. ERTS CENTER METER ASSEMBLY WITHIN BOX. DEPRESS LINE TO MEET BUILDING DEPT. N REQUIREMENTS. 0* 10 14 15 O* hh FLOV1� — — — — O* O 11 12 13 OOO* PIPE MATERIAL TO O7 MEET BUILDING DEPT. 11101, NMI REQUIREMENTS. FILTER FABRIC 3/4 , DRAIN ROCK MIN. 6 THICK AND EXTENDING 6" BEYOND BOX ELEVATION CONCRETE METER BOX W/ 10" READING LID. PROVIDE 2 EXTENSIONS UNDER BOX. IN -LINE CONNECTOR WITH SECURITY SEAL © ® O* O* 10 I I O* *O* O* co a * 0* 16 I 11 12 13 14 I 15 16 * 18 I * * I I 20 21 I * 20 7.25' MIN. NOTES: PLAN 1. BYPASS PIPING SHALL BE REQUIRED ON MULTIFAMILY RESIDENTIAL AND COMMERCIAL SERVICES. BYPASS PIPING 9. NO FENCING SHALL BE INSTALLED BETWEEN MAY BE OMITTED ON ALL IRRIGATION SERVICES. WITH APPROVAL OF THE CITY ENGINEER, BYPASS PIPING MAY BE STREET AND METER BOX. OMITTED ON COMMERCIAL SERVICES SERVING OFFICE OR RETAIL SPACE WITH SEPARATE FIRE SERVICES OR WHERE MULTIPLE DOMESTIC WATER SERVICES SERVE THE PROPERTY. 10. ALL COMPRESSION FITTINGS SHALL HAVE STAINLESS STEEL INSERTS. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE THE CITY WILL ACTIVATE SERVICE. 3. METER ASSEMBLY SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ERTS AND TRANSMITTING REGISTERS WITH 5 FT. LEADS. * = OMIT WHEN BYPASS IS NOT REQUIRED. 4. REFER TO CITY STANDARD 877 FOR GATE VALVE INSTALLATION DETAILS. VALVES MAY BE INSTALLED IN SIDEWALK WHERE SPACE LIMITATIONS EXIST. ** = OMIT WHEN BACKFLOW DEVICE IS INSTALLED DOWNSTREAM AND BYPASS IS NOT REQUIRED 5. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 6. PIPE OPENINGS IN METER BOX SHALL BE CUT - DO NOT USE HAMMER. PRIOR TO BACKFILLING, PIPE OPENINGS AND CITY OF RO H N E RT PARK BOX JOINTS SHALL BE GROUTED. 7. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN. IN ABSENCE OF MAIN TRACER WIRE, WRAP 2" COMMERCIAL WATER SERVICE SERVICE TRACER WIRE AROUND THE MAIN. RUN CONTINUOUS FROM MAIN TO METER BOX WITH LOOPS INTO EACH VALVE BOX. SCALE: NONE DATE: OCTOBER 2010 8. ERTS TO BE MOUNTED IN APPROVED BRACKET ATTACHED TO BOX W /SS ANCHORS. THE TOP OF ERTS SHALL BE NO Approved: MORE THAN 3 -1/4" BELOW TOP OF BOX. STD. - 865B 1. BYPASS PIPING SHALL BE REQUIRED ON MULTIFAMILY RESIDENTIAL AND COMMERCIAL SERVICES. BYPASS PIPING MAY BE OMITTED ON ALL IRRIGATION SERVICES. WITH APPROVAL OF THE CITY ENGINEER, BYPASS PIPING MAY BE OMITTED ON COMMERCIAL SERVICES SERVING OFFICE OR RETAIL SPACE WITH SEPARATE FIRE SERVICES OR WHERE MULTIPLE DOMESTIC WATER SERVICES SERVE THE PROPERTY. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE THE CITY WILL ACTIVATE SERVICE. 3. METER ASSEMBLY SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ERTS AND TRANSMITTING REGISTERS WITH 5 FT. LEADS. 4. REFER TO CITY STANDARD 877 FOR GATE VALVE INSTALLATION DETAILS. VALVES MAY BE INSTALLED IN SIDEWALK WHERE SPACE LIMITATIONS EXIST. 5. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 6. PIPE OPENINGS IN METER BOX SHALL BE CUT - DO NOT USE HAMMER. PRIOR TO BACKFILLING, PIPE OPENINGS AND BOX JOINTS SHALL BE GROUTED. 7. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN. IN ABSENCE OF MAIN TRACER WIRE, WRAP SERVICE TRACER WIRE AROUND THE MAIN. RUN CONTINUOUS FROM MAIN TO METER BOX WITH LOOPS INTO EACH VALVE BOX. 8. ERTS TO BE MOUNTED IN APPROVED BRACKET ATTACHED TO BOX W /SS ANCHORS. THE TOP OF ERTS SHALL BE NO MORE THAN 3 -1/4" BELOW TOP OF BOX. 9. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. NO. ITEM DESCRIPTION QTY. 4' MAX. TEE OR TAPPING TEE W/ 4" FLANGED OUTLET 1 2 4" GATE VALVE FLG X MJ W/ MEGA -LUG RETAINER GLAND STAMP 4" "W" ON FACE OF CURB SIDEWALK 4" DIP PE LENGTH AS REQUIRED INTERMEDIATE JOINTS RESTRAINED 2 ERTS 4" 900 ELL MJ W/ MEGA -LUG RETAINER GLANDS 1 5 4" 900 ELL MJ W/ MEGA -LUG RETAINER GLAND X FLG 1 6 4" TEE FLG 2 7 ' 2 8 4" X 3" REDUCER FLG 2 9 3" DIP SPOOL FLG 18" MIN. LENGTH 1 DEPRESS LINE TO 3" PLATE STRAINER 1 11 3" COMPOUND METER W/ 2 TRANSMITTING REGISTERS AND 2 ERTS 1 12 3" FCA 1 13 3" DIP FLG X PE 18" MIN. LENGTH 1 14 4" COMPANION FLANGE W/ 2" THREADED TAP 2 MEET BUILDING DEPT. 2" BRASS NIPPLE THREADED 18" MIN. LENGTH 2 16 2" BRASS ELL THREADED 2 17 2" x 4" BRASS NIPPLE THREADED 1 18 2" BRASS BALL VALVE WITH STOPS AND 2" SQUARE OPERATING NUT 1 19 2" BRASS PIPE THREADED X PE LENGTH AS NECESSARY 2 REQUIREMENTS. 2" 2 -BOLT DRESSER 1 O $ O g - TRACER WIRE: BLUE INSULATION, FLOW , 13 O 10 11 O 12 O ** O1 #12 SOLID COPPER 3 O PIPE MATERIAL TO klk MEET BUILDING DEPT. 33 REQUIREMENTS. O 4 FILTER FABRIC 3/4 DRAIN ROCK MIN. 6 , THICK O2 AND EXTENDING 6" BEYOND BOX A 0 ELEVATION CONCRETE METER BOX W/ 10" READING LID. PROVIDE 2 EXTENSIONS UNDER BOX. CENTER IN -LINE CONNECTOR WITH SECURITY SEAL (TYP. METER ASSEMBLY IN BOX. WATER MAIN O 0 © ® 90 13 8 ©* ri * O I 10 11 12 7 ** 14 14 z 15 * * * * 15 N * rs 16 * 16 8.75' MIN. NOTES: PLAN 1. BYPASS PIPING SHALL BE REQUIRED ON MULTIFAMILY RESIDENTIAL AND COMMERCIAL SERVICES. BYPASS PIPING MAY BE OMITTED ON ALL IRRIGATION SERVICES. WITH APPROVAL OF THE CITY ENGINEER, BYPASS PIPING MAY BE OMITTED ON COMMERCIAL SERVICES SERVING OFFICE OR RETAIL SPACE WITH SEPARATE FIRE SERVICES OR WHERE MULTIPLE DOMESTIC WATER SERVICES SERVE THE PROPERTY. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE THE CITY WILL ACTIVATE SERVICE. 3. METER ASSEMBLY SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ERTS AND TRANSMITTING REGISTERS WITH 5 FT. LEADS. 4. REFER TO CITY STANDARD 877 FOR GATE VALVE INSTALLATION DETAILS. VALVES MAY BE INSTALLED IN SIDEWALK WHERE SPACE LIMITATIONS EXIST. 5. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 6. PIPE OPENINGS IN METER BOX SHALL BE CUT - DO NOT USE HAMMER. PRIOR TO BACKFILLING, PIPE OPENINGS AND BOX JOINTS SHALL BE GROUTED. 7. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN. IN ABSENCE OF MAIN TRACER WIRE, WRAP SERVICE TRACER WIRE AROUND THE MAIN. RUN CONTINUOUS FROM MAIN TO METER BOX WITH LOOPS INTO EACH VALVE BOX. 8. ERTS TO BE MOUNTED IN APPROVED BRACKET ATTACHED TO BOX W /SS ANCHORS. THE TOP OF ERTS SHALL BE NO MORE THAN 3 -1/4" BELOW TOP OF BOX. 9. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. NO. ITEM DESCRIPTION QTY. 1 TEE OR TAPPING TEE W/ 4" FLANGED OUTLET 1 2 4" GATE VALVE FLG X MJ W/ MEGA -LUG RETAINER GLAND 1 3 4" DIP PE LENGTH AS REQUIRED INTERMEDIATE JOINTS RESTRAINED 2 4 4" 900 ELL MJ W/ MEGA -LUG RETAINER GLANDS 1 5 4" 900 ELL MJ W/ MEGA -LUG RETAINER GLAND X FLG 1 6 4" TEE FLG 2 7 4" GATE VALVE FLG 2 8 4" X 3" REDUCER FLG 2 9 3" DIP SPOOL FLG 18" MIN. LENGTH 1 10 3" PLATE STRAINER 1 11 3" COMPOUND METER W/ 2 TRANSMITTING REGISTERS AND 2 ERTS 1 12 3" FCA 1 13 3" DIP FLG X PE 18" MIN. LENGTH 1 14 4" COMPANION FLANGE W/ 2" THREADED TAP 2 15 2" BRASS NIPPLE THREADED 18" MIN. LENGTH 2 16 2" BRASS ELL THREADED 2 17 2" x 4" BRASS NIPPLE THREADED 1 18 2" BRASS BALL VALVE WITH STOPS AND 2" SQUARE OPERATING NUT 1 19 2" BRASS PIPE THREADED X PE LENGTH AS NECESSARY 2 20 2" 2 -BOLT DRESSER 1 * = OMIT WHEN BYPASS IS NOT REQUIRED. ** = OMIT WHEN BACKFLOW DEVICE IS INSTALLED DOWNSTREAM AND BYPASS IS NOT REQUIRED LOOP TRACER WIRE INTO VALVE BOX (TYP.)— O STAMP 4" "W" ON FACE OF CURB ---- SIDEWALK O IN -LINE CONNECTOR WITH SECURITY SEAL (TYP. WATER MAIN 0 NOTES: 1. BYPASS PIPING SHALL BE REQUIRED ON MULTIFAMILY RESIDENTIAL AND COMMERCIAL SERVICES. BYPASS PIPING MAY BE OMITTED ON ALL IRRIGATION SERVICES. WITH APPROVAL OF THE CITY ENGINEER, BYPASS PIPING MAY BE OMITTED ON COMMERCIAL SERVICES SERVING OFFICE OR RETAIL SPACE WITH SEPARATE FIRE SERVICES OR WHERE MULTIPLE DOMESTIC WATER SERVICES SERVE THE PROPERTY. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE THE CITY WILL ACTIVATE SERVICE. 3. METER ASSEMBLY SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ERTS AND TRANSMITTING REGISTERS WITH 5 FT. LEADS. 4. REFER TO CITY STANDARD 877 FOR GATE VALVE INSTALLATION DETAILS. VALVES MAY BE INSTALLED IN SIDEWALK WHERE SPACE LIMITATIONS EXIST. 5. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 6. PIPE OPENINGS IN METER BOX SHALL BE CUT - DO NOT USE HAMMER. PRIOR TO BACKFILLING, PIPE OPENINGS AND BOX JOINTS SHALL BE GROUTED. 7. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN. IN ABSENCE OF MAIN TRACER WIRE, WRAP SERVICE TRACER WIRE AROUND THE MAIN. RUN CONTINUOUS FROM MAIN TO METER BOX WITH LOOPS INTO EACH VALVE BOX. 8. ERTS TO BE MOUNTED IN APPROVED BRACKET ATTACHED TO BOX W /SS ANCHORS. THE TOP OF ERTS SHALL BE NO MORE THAN 3 -1/4" BELOW TOP OF BOX. 9. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. * ELEVATION % o Ot 4--al DEPRESS LINE TO MEET BUILDING DEPT. REQUIREMENTS. PIPE MATERIAL TO MEET BUILDING DEPT. REQUIREMENTS. 3/4" DRAIN ROCK MIN. 6" THICK AND EXTENDING 6" BEYOND BOX CONCRETE METER BOX W/ 10" READING LID. PROVIDE 2 EXTENSIONS UNDER BOX. CENTER METER ASSEMBLY IN BOX. 13 13 0 * O* � O 9' MIN. NO. ITEM DESCRIPTION QTY. 1 TEE OR TAPPING TEE W/ 4" FLANGED OUTLET 1 2 4" GATE VALVE FLG X MJ W/ MEGA -LUG RETAINER GLAND 1 3 4" DIP PE LENGTH AS REQUIRED INTERMEDIATE JOINTS RESTRAINED 2 4 4" 90° ELL MJ W/ MEGA -LUG RETAINER GLANDS 3 5 4" 900 ELL MJ W/ MEGA -LUG RETAINER GLAND X FLG 1 6 4" TEE FLG 2 7 4" GATE VALVE FLG 3 8 4" DIP SPOOL FLG 24" MIN. LENGTH 1 9 4" PLATE STRAINER 1 10 4" COMPOUND METER W/ 2 TRANSMITTING REGISTERS AND 2 ERTS 1 11 4" FCA 1 12 4" DIP FLG X PE 24" MIN. LENGTH 1 13 1 4" DIP FLG X PE 2 6 13* z 2 Lo N * =OMIT WHEN BYPASS IS NOT REQUIRED. ** = OMIT WHEN BACKFLOW DEVICE IS INSTALLED DOWNSTREAM AND BYPASS IS NOT REQUIRED NOTES: 1. BYPASS PIPING SHALL BE REQUIRED ON MULTIFAMILY RESIDENTIAL AND COMMERCIAL 11' MIN. SERVICES. BYPASS PIPING MAY BE OMITTED ON ALL IRRIGATION SERVICES. WITH r' t_� APPROVAL OF THE CITY ENGINEER, BYPASS PIPING MAY BE OMITTED ON COMMERCIAL SERVICES SERVING OFFICE OR RETAIL SPACE WITH SEPARATE FIRE SERVICES OR WHERE MULTIPLE DOMESTIC WATER SERVICES SERVE THE PROPERTY. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE THE CITY WILL ACTIVATE SERVICE. 3. METER ASSEMBLY SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ERTS AND TRANSMITTING REGISTERS WITH 5 FT. LEADS. 4. REFER TO CITY STANDARD 877 FOR GATE VALVE INSTALLATION DETAILS. VALVES MAY BE INSTALLED IN SIDEWALK WHERE SPACE LIMITATIONS EXIST. 5. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 6. PIPE OPENINGS IN METER BOX SHALL BE CUT - DO NOT USE HAMMER. PRIOR TO BACKFILLING, PIPE OPENINGS AND BOX JOINTS SHALL BE GROUTED. 7. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN. IN ABSENCE OF MAIN TRACER WIRE, WRAP SERVICE TRACER WIRE AROUND THE MAIN. RUN CONTINUOUS FROM MAIN TO METER BOX WITH LOOPS INTO EACH VALVE BOX. 8. ERTS TO BE MOUNTED IN APPROVED BRACKET ATTACHED TO BOX W /SS ANCHORS. THE TOP OF ERTS SHALL BE NO MORE THAN 3 -1/4" BELOW TOP OF BOX. 9. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. NO. ITEM DESCRIPTION QTY. 1 4' MAX. 1 2 6" GATE VALVE FLG X MJ W/ MEGA -LUG RETAINER GLAND 1 3 6" DIP PE LENGTH AS REQUIRED INTERMEDIATE JOINTS RESTRAINED STAMP 4" "W" ON FACE OF CURB � SIDEWALK �� 4 6" 90° ELL MJ W/ MEGA -LUG RETAINER GLANDS ERTS 5 6" 90° ELL MJ W/ MEGA -LUG RETAINER GLAND X FLG 1 6 6" X 4" TEE FLG 1 7 :.' .. •�. '• " :.' .. DEPRESS LINE TO 9 6" PLATE STRAINER 1 10 6" COMPOUND METER W/ 2 TRANSMITTING REGISTERS AND 2 ERTS 1 11 6" FCA MEET BUILDING DEPT. 12 6" DIP FLG X PE 30" MIN. LENGTH 1 13 4" GATE VALVE FLG 1 14 4" DIP FLG X PE LENGTH AS REQUIRED REQUIREMENTS. 15 4" 900 ELL MJ W/ MEGA -LUG RETAINER GLANDS 2 * 4" DIP PE SINGLE PIECE LENGTH AS REQUIRED 1 N 12LOOP TRACER WIRE INTO VALVE BOX (TYP.) —� TRACER WIRE: 7#12 10 11 BLUE INSULATION, SOLID COPPER 4-- PIPE MATERIAL TO MEET BUILDING DEPT. 33 REQUIREMENTS. FILTER FABRIC 3/4 DRAIN „ ROCK MIN. 6 THICK AND EXTENDING 6" BEYOND BOX ,0'0 O o ELEVATION CONCRETE METER BOX W/ 10" READING LID. PROVIDE 2 EXTENSIONS UNDER BOX. CENTER IN -LINE CONNECTOR WITH SECURITY SEAL (TYP) METER ASSEMBLY IN BOX. WATER MAIN — — — — — — o — — — — — — — o o\ of * Li - - - -� 14 z 14 * 15 16 NOTES: 1. BYPASS PIPING SHALL BE REQUIRED ON MULTIFAMILY RESIDENTIAL AND COMMERCIAL 11' MIN. SERVICES. BYPASS PIPING MAY BE OMITTED ON ALL IRRIGATION SERVICES. WITH r' t_� APPROVAL OF THE CITY ENGINEER, BYPASS PIPING MAY BE OMITTED ON COMMERCIAL SERVICES SERVING OFFICE OR RETAIL SPACE WITH SEPARATE FIRE SERVICES OR WHERE MULTIPLE DOMESTIC WATER SERVICES SERVE THE PROPERTY. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE THE CITY WILL ACTIVATE SERVICE. 3. METER ASSEMBLY SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ERTS AND TRANSMITTING REGISTERS WITH 5 FT. LEADS. 4. REFER TO CITY STANDARD 877 FOR GATE VALVE INSTALLATION DETAILS. VALVES MAY BE INSTALLED IN SIDEWALK WHERE SPACE LIMITATIONS EXIST. 5. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 6. PIPE OPENINGS IN METER BOX SHALL BE CUT - DO NOT USE HAMMER. PRIOR TO BACKFILLING, PIPE OPENINGS AND BOX JOINTS SHALL BE GROUTED. 7. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN. IN ABSENCE OF MAIN TRACER WIRE, WRAP SERVICE TRACER WIRE AROUND THE MAIN. RUN CONTINUOUS FROM MAIN TO METER BOX WITH LOOPS INTO EACH VALVE BOX. 8. ERTS TO BE MOUNTED IN APPROVED BRACKET ATTACHED TO BOX W /SS ANCHORS. THE TOP OF ERTS SHALL BE NO MORE THAN 3 -1/4" BELOW TOP OF BOX. 9. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. NO. ITEM DESCRIPTION QTY. 1 TEE OR TAPPING TEE W/ 6" FLANGED OUTLET 1 2 6" GATE VALVE FLG X MJ W/ MEGA -LUG RETAINER GLAND 1 3 6" DIP PE LENGTH AS REQUIRED INTERMEDIATE JOINTS RESTRAINED 2 4 6" 90° ELL MJ W/ MEGA -LUG RETAINER GLANDS 1 5 6" 90° ELL MJ W/ MEGA -LUG RETAINER GLAND X FLG 1 6 6" X 4" TEE FLG 1 7 6" GATE VALVE FLG 2 8 6" DIP SPOOL FLG 30" MIN. LENGTH 1 9 6" PLATE STRAINER 1 10 6" COMPOUND METER W/ 2 TRANSMITTING REGISTERS AND 2 ERTS 1 11 6" FCA 1 12 6" DIP FLG X PE 30" MIN. LENGTH 1 13 4" GATE VALVE FLG 1 14 4" DIP FLG X PE LENGTH AS REQUIRED 2 15 4" 900 ELL MJ W/ MEGA -LUG RETAINER GLANDS 2 16 4" DIP PE SINGLE PIECE LENGTH AS REQUIRED 1 * = OMIT WHEN BYPASS IS NOT REQUIRED. ** = OMIT WHEN BACKFLOW DEVICE IS INSTALLED DOWNSTREAM AND BYPASS IS NOT REQUIRED (Alternate F.D.C. locatioi (SEE STD 880 3' clear I I �Jcn I Note: The contractor shall obtain approval from the fire department prior to starting the fire protection service. i _ . Fire De artment I I o c I I p Q° � o connection 24 "High I I °- L' from finish grade o ' E +; C) W 4, Final location to I I o L` o° be determined b °' the Fire De t y I o _ Provide Construction Joints as shown. Screen Wall to Match The Building Exterior. 12 "x 12" Footing under, 8 "x8"x16" Conc. Block Screen Wall (Typ.) Alternate F.D.C. p if On 4" P.C.C. Slab I I i i i i Back of Sidewalk 10' Max. & within city 4' I I i i i i right of way Fire Hydrant ----- - - - - -- L -------- u----- - -u - -� Per 857 <> ----- - - - - -- -------------- - - - - -� I I Per 887 This configuration is permissible only with an 20' Max. ow 8 —inch min. pipe stub. NOTES: I 1 45 1 Min. II 1 1I4" Fl (TYP fi" Conc. Slab 18'Min. 1 IBMin. l 11 24 Min. 11 30 "16in. aII III II II 2. The equipment screen shall be located per the site plan. Domestic & irrigation meters shall be installed per std. 863 & 865. The length & width of the screen depends II II domestic water services. top of wall shall not restrict the view of the valve yoke from the street. PRIOR TO CONNECTION TO EXISTING CITY WATER SERVICE OR MAIN THE CONTRACTOR SHALL: a. Install a 2" minimum bridge connection for construction water and testing per std. 859. b. Pressure test line from point of connection to fire bridge and all domestic lines. c. Have all backflow assemblies tested by City certified testing contractor. Submit complete installation record and testing record for each assembly to Public Works Dept., 600 Enterprise CITY OF ROHNERT PARI Drive (forms available at 600 Enterprise Dr.,(707) 588 - 3300). d. Have passing results from bacteria testing samples taken i _ . Fire De artment I I o c I I p Q° � o connection 24 "High I I °- L' from finish grade o ' E +; C) W 4, Final location to I I o L` o° be determined b °' the Fire De t y I o _ Provide Construction Joints as shown. Screen Wall to Match The Building Exterior. 12 "x 12" Footing under, 8 "x8"x16" Conc. Block Screen Wall (Typ.) Alternate F.D.C. p if On 4" P.C.C. Slab I I i i i i Back of Sidewalk 10' Max. & within city 4' I I i i i i right of way Fire Hydrant ----- - - - - -- L -------- u----- - -u - -� Per 857 <> ----- - - - - -- -------------- - - - - -� I I Per 887 This configuration is permissible only with an 20' Max. ow 8 —inch min. pipe stub. NOTES: 1. Fire hydrant shall be located within 50' of the F.D.0 or as approved by the Fire Code Official. 2. The equipment screen shall be located per the site plan. Domestic & irrigation meters shall be installed per std. 863 & 865. The length & width of the screen depends on the size and number of irrigation and domestic water services. top of wall shall not restrict the view of the valve yoke from the street. PRIOR TO CONNECTION TO EXISTING CITY WATER SERVICE OR MAIN THE CONTRACTOR SHALL: a. Install a 2" minimum bridge connection for construction water and testing per std. 859. b. Pressure test line from point of connection to fire bridge and all domestic lines. c. Have all backflow assemblies tested by City certified testing contractor. Submit complete installation record and testing record for each assembly to Public Works Dept., 600 Enterprise CITY OF ROHNERT PARI Drive (forms available at 600 Enterprise Dr.,(707) 588 - 3300). d. Have passing results from bacteria testing samples taken by City, call (707) 588 -3300 minimum 48 hours prior. "Tamper ". WATER CONNECTION DETAIL e. All valves shall be hooked up for Alarm f. Satisfy all Fire Department requirements. g. The meter shall be installed with proper lengths of pipe both SCALE: NONE DATE: OCTOBER 2010 upstream and down stream of the meter see manufacturers specifications for determining pipe length(s). Approved: h. A utility billing account shall be opened with city prior to flowing STD. - 86c water through meter. Min. 2" thick rough cut treated redwood planks with opening cut to Redwood 2 x 4 fit water main or approved stakes manufactured casing plug. Ductile iron A Water main PI-47 iv,uvy uu,.y skid ♦ Steel �� 4 conductor A casing as specified Min 2" thick rough cut treated redwood planks with opening cut to fit water main 0 -�� 0 \` 0 -74 II 0 I/ 2' :MIN. NOTES TYPICAL DIRT STOP DETAIL 1. Install skids per manufacturers NO SCALE specifications. 2. See Engineer's approved list for approved skids. 3. Where conductor casing is existing R.C.P., banded redwood skids may be installed in lieu of polyethylene skids with 8" 8 8 8" Utilities Dept. approval. Max. Max. U Skid height to be APPROVED PIPES: such that pipe joints Ductile iron pipe w /restrained joints, do not rest on casing. TR flex or Field Lok restrained joint Ductile Iron pipe, Certainteed Yellowmine Certa —Lok PVC pipe TYPICAL PIPE JOINT AND INSULATOR 5/16" Cadmium plated bolts Wate Pipe 5/16" Ca( plated bol Polyeth; skids NO SCALE SECTION "A —A" NO SCALE ivy duty FI liner Steel band Steel conductor casing as specified r Minimum size casing required For all approved pipe types Pipe Size 6" 8" 12" 14" 16" Casing Size (Inside 0) 16" 18" 24" 24" 30" Casing Wall 375" Thickness .375" .375" .375" X ° � L ° ° a� L v L ?� o ^ o _ E� U ° > •> N U) N N N ° N ° (n p (n .L CL (n cn — — ° — (n CL 0 °, — > a�L' Q � �� �°L, p ° •Q O N m Ov N -0 p N —� C �.— O-0 > U E� °�� O N ° N C In > OL '> O O L. CL N L Q ° LL_ O � N ° 0 O ° O � U) � N� U � N U) E. -0 N N o NO ��0>. Qcn 'L o L _rZ ° -N-0 4-j L 0 � o > C31 0 u 4-j ° _0 � L c: c: � N °' -0 (n L. > O U ° Y — �' N p •" O_ C (D :3 N 0 (n U) U 4 O w -0 U) ° C N — > U) U U N N O° Q Q Ld U � -' O (n (nom ~ !E U � — .. rn L N Y 4--+ _ ° ' N ° ° °' — cn U -0 C W L_ L pF W W 1 ° ° U n c ° U — N 7 >%.— N — N .- �(n N� CO - O -0- (A _y� °� N� N 0 O-0 > L ULL. 0 CV -+, p O -0 -0 � -�- C > ° N ° 0 p° p U N 3U ° p �� N0 V _y > ° U _c >. � � +� a (n O � O o L ° (n ui Lm c: 4_0 4_0 ��0� I: (n0 UL (n0L• E –°�� > E > -0� 0 O-O O n�i ° O'er 3: O L (n.- > — 0 N — c: > 0 c w 0 E 0 W 0 0 0 > N O o' Q N N N: �O (1) 0 U 0 0 m Q ++ n N `� N N U— L (n O 3 O C L p — -0- n ° — N 0 O p N — > C ( 0 n U N ° •— ° >>U) 0 U) ° U N j Lm m (n (N n C)- Q°�� c 'I X Ll ° �. .' CITY OF RO H N E RT PARK -0 REDUCED PRESSURE BACKFLOW ASSEMBLY 0 ° a I I SCALE. NONE DATE. OCTOBER 2010 I Approved: O N i Lv�jv a STD. _ 876 VALVE BOXES: STEM EXTENSION FABRICATION NOTES: (See Engineer's approved list) Precast valve box set flush with street 1. All welds to riser shaft shall be fillet surface with cast iron ring and cover weld all around as specified below. marked "WATER ". 2. All steel required for riser fabrication shall be structural steel per ASTM A36. Finished grade 000 0 v 6 Min. 118" Min. O O " a O 00000 0 00 O 8" Max. � 30" Max. O O O o0 0 0 0 0 3/16 p a 0 Class "A" conc. collar from 3" below finished 4" O O O rode. a 3 O g i 2" I Mi 0 NI N VALVE STEM EXTENSION PARTS LIST: Q Valve operating nut or 1- 7/8 "x1- 7/8 "x2" high solid steel welded to top plate. Q 3/16" thk. x 7 -1/2" dia. free spinning guide plate, with 3 -5/8' dia. hole in center. Q Two 3/16 "x1 -1 /2 "x1 -1 /2 "X1 -1 /2 "X5 "L steel angle weld to two sides of riser shaft. Q 2 -1/2" x 3/16" square steel tubing length as required edge to weld to top plate. Q 3" x 3" x 1/4" steel top plate. Riser shaft after guide plate is in place. Tracer wire: blue insulation #12 solid copper w/2" -3" pigtail NOTES: 1. Valves 2" to 12" shall be resilient wedge gate valves and valves larger than 12" shall be butterfly valves (see Std. 878) unless otherwise approved by the Utilities Dept. 2. Gate valves shall conform to City Specification number 99 -1.05. 3. All external bolts and nuts on valves shall be 304 stainless steel or the entire valve shall be wrapped tightly with polyethylene film held securely with adhesive tape. 4. If valve is installed so that the top of the operating nut is less than 30" below finished grade, the valve stem riser is not required. 5. For installation of butterfly valve and tapping valve, see Std. 878. I ' � O I 8" SDR 35 PVC sewer pipe conforming to ASTM 3034. I i Riser pipe to be plumb and centered over valve stem, and shall be constructed from a single length of pipe, with no joint. — D ' a 4 Concrete pier block required when installing new valve on existing main. All Butterfly valves shall conform to City Specification Number 99 -1.06 Install Flanged Butterfly valve with �i two flanged by mechanical adapters on Class 200 PVC. •� f Valve box, valve stem extension, o �p77:0 & valve riser (See Std. 877) BUTTERFLY VALVE To be used on pipe larger than 12" TAPPING SLEEVE & VALVE To be used on pipe 2" to 12" (See Engineer's Approved List for Std. 866/867) NOTES: 1. All external bolts and nuts on valves shall be 304 stainless steel or the entire valve shall be wrapped tightly with polyethylene film held securely with adhesive tape. 2. Taps shall be made by Contractor. 3. Valves 2" to 12" shall be resilient wedge gate valves and valves larger than 12" shall be butterfly valves unless otherwise approved by the Utilities Dept. Approximate Excavation Area Valve box, valve stem extension, j /\ & valve riser \�/ (See Std. 877) Water Main 3/4", 1 " & 2" Taps: 5' Long x 2' -6" Wide Tap Pit Concrete thrust 4" & Larger: 6' Long x 4' Wide Dimensions Block (See Std. 854)---,-- �� 5/ .. • a Tapping Machine PP� 9 a fi ° 6" Min. d Tapping sleeve or °. Conc. pier block (on undisturbed earth) hydrant tee \� /��/ TAPPING SLEEVE & VALVE To be used on pipe 2" to 12" (See Engineer's Approved List for Std. 866/867) NOTES: 1. All external bolts and nuts on valves shall be 304 stainless steel or the entire valve shall be wrapped tightly with polyethylene film held securely with adhesive tape. 2. Taps shall be made by Contractor. 3. Valves 2" to 12" shall be resilient wedge gate valves and valves larger than 12" shall be butterfly valves unless otherwise approved by the Utilities Dept. ^ N N C) o Q) L L 0) Q- 0 0 (n O ?� O U •L -0 C CU co 0 O j •� N v 0- Li a 0 C N N L LL Z C CLLL,> 0 L ^ O "O � N U O •3 c �' U a L U v N N OL (A O L L o a 3 c — U "v v c -0 L •> +' +' N I 0 O L v N � •v :a a• .: � U4) a W O v L. O 4-j d ° 0O N O •U - O � v ° d .• O 0 v 0 30" Min — 36" Max. o o c > ° . ax. 0 0 0 00°00 U � N �p0 -c � cn 00 -c O O� L c c O< T ^ c c N N � O N V) W _ N 00 Q) 014 W > J a, > J •c / I X 1, I O W Y 0 w ° U O �p w > O N °' . 2 U m � U o- I a Q CL O �J 0 �co c c U L O O °. N 'co 0-0 O� W O a� c L - ° a o W n °J ( o - 0 � o� � o_ Q) a�c� = o N O cn OOp L o L - o o .. ° 0 Op0 �.., a ++ — > N a ° 000 O 0 OL O c ° > 0p0 N O- U N 0 0) Q- N N � O O L Cn O D_ _O m.�U Q _00 w ^ N� D O O :P U O ++ -c O •LV 0 -O O N0 UN 3 ° OO •3�•- 0!� (L) -C v -0 ° Q) L•C N L U > in a Lo U N •0- - O U p -0 E c •cA N O co Q o LO O J co CITY OF ROHNERT PARK o-t N o UNDERGROUND FIRE LINE SINGLE CHECK DETECTOR IN VAULT SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 879 PAGE 1 OF 3 BY -PASS PARTS LIST NO. DESCRIPTION QUANT. PART SIZE OR MODEL NO.* 1. HOSE BIB — MIP 3 3/4" 2. TEE — FIP x FIP x FIP 3 3/4" 3. SHORT MTR SPUD — 2" L 2 C38 — 23 — 2 4. STRAIGHT CHK. VALVE — MIP x FIP 1 HS81 — 333 5. ADAPTER — COMP x MIP 1 C84 — 33 6. BRASS VARIES 3/4" 7. 90' ADAPTER — COMP x MIP 4 L84 — 33 8. STRAIGHT BALL VALVE — FIP x FIP 2 B11 — 33 9. CLOSE NIPPLE 4 3/4" 10. 90' ADAPTER — COMP x FIP 1 L14 — 33 11. ADAPTER — COMP x FIP 2 C14 — 33 12. BUSHING 2 3/4" x VARIES * FORD MODEL NO's ARE GIVEN. SUBMIT SUBSTITUTIONS FOR APPROVAL. NOTES: 1 • The post indicator valve shall be installed as close as possible to the detector check vault. If a post indicator cannot be installed, an O.S. & Y. valve with locking chain must be installed inside the vault on the property side of the detector check with approval from the City Utilities Department. 2. The installation shall be provided with electronic supervision monitoring when required by the Fire Department. 3. Refer to vault size chart for proper size. Should an O.S. & Y. valve be installed in the vault, the vault size may need to be verified by the Contractor. See the engineer's approved list for approved vaults and covers. 4. All fire line services to the post indicator valve shall be tested by the Fire Services Construction inspection section per City of Rohnert Park Construction Specifications. All on —site fire lines, hydrants, and the P.I.V. shall be tested & inspected by the Fire Dept. per City Fire Code. 5. Double check detector check valve assembly with bypass double check shall be installed where an underground fire suppression system enters private property Installation details shall be approved by the Utilities Dept. prior to installation. (See Std. 880). 6. The fire department connection shall be installed and located as required by the Fire Department. 7. Post indicator valves shall be locked with a break —away lock. The top of the P.I.V. shall not be less than thirty —six inches (36 ") above finished grade. 8. Use only downstream of double detector check backflow preventer. 9. Single check valves may only be used in addition to a double detector check valve. VAULT SIZES D.C. SIZE WIDTH LENGTH 4" 4' 4' 6' 4' 4' 8" 5' S' 10" 5' S' PAGE 2 OF 3 Utilities Dept. Maint. Property Owner Responsibility Responsibility For 4" & larger install adjustable supports. (Two required) - 12" min. above finished grade or 6" above the inundation Sidewalk level, whichever is higher • d •a 6" Min. from back of sidewalk Public Works Inspector Fire Dept. Inspector Approved 4 ",6 ",8 "or 10" double check valve Double gate valve assembly Shut —off valves (See note 6) Test cocks Fire Dept. connection (FDC) 1 2 3 4 4" 90° Siamese pumper connection with dual 2 1/2" outlets (when required, See note 7) Factory installed bypass assembly and meter. Expansion ring, fill void with /—Concrete pad to extend sand 6" beyond risers. A — _ — — a — — (both sides) D.I.P D.I.P 3" thick concrete pad Provide 1 to conduit min. 2' -0" wide for for tamper switch 4 "0 and larger assemblies controls. (see note 8) (See note 10) Co. v Co. % v Co. v Co. v Co. � a I 1>`a° iai ai °alai °alai° alai° alai° To building NOTES: 1. This Standard is required for: a. all connections serving commercial fire sprinkler systems. b. any fire line connections to properties with auxiliary water supplies. c.) sites with multiple fire line connections to the City water system. 2. Approved double check detector backflow assemblies shall be shown on "List of approved backflow devices" of latest revision, by the University of Southern California Foundation for Cross Connection Control & Hydraulic Research. 3. All test valves shall be fitted with 1/4" female test cocks. 4. Double check detector assembly shall be located as close as possible to the sidewalk or public right —of —way. 5. Any cover or screening for this assembly must have both Fire Department & Engineering Department approval prior to installation. 6. Shut —off valves to be resilient wedge type O.S. & Y and will be chained and padlocked in the open position. 7. Must have specific approval of the Fire Dept. prior to installation. Location to be determined by the Fire Dept. 8. The installation shall be provided with electronic supervision monitoring when required required by the Fire Department. 9. Double check detector shall be the same size as the fire line except when a 12" fire line is required, then a 10" double detector check backflow assembly is required. 10. Restrained joints are required for all new construction from gate valve to 90' ell. Thrust blocks are only required where existing services are being modified and restrained joints are not used. High pressure water system O O2 ITEM Mainline gate valve to remain in closed position to isolate pressure zones. Vault – (see note 2) F/C Low pressure O water system O2 O2 MECHANICAL JOINT GATE VALVE STD. 877 0 DUCTILE IRON PIPE — FL. X P.E. O 11 © % O 0 r1---% , O % a• O , /Fire A ' Q Hydrant A and lateral Fire hydrant FLANGED GATE VALVE STD. 877 11 Per Std. 857 and lateral Per Std. 857 FLANGED COUPLING ADAPTER (See note 1 4 3 (See note 4) (See note 4) - 15 3/4" BRASS 16 ' 0 3/4" M.I.P X HOSE BIBB — BRASS 10 11 13 12 10 , ' - -.6 - -„ Restrained joints PLAN VIEW (see note 8) Set lid to open Finished grade or top of curb elev. perpendicular to curb �- %V, % 1 i 17 O 1 g ' a 16 6 30 » Min. 15 15 Valve & riser 36" Max. 4 x 12 Redwood blocking Per Std. 877 cover 14 14 pad ,p.a Typical dirt stop per Std. 872 „ a 6 Thick x 18 wide .a, o - ��.��, , ,�,� at all vault openings (Grouting optional) � continuous Class A �. �\ �� concrete footing. SECTION A —A Drain line – (see note 5) 3/4" Drain rock – min. 12" thick NOTES: 1. Make 3/4" top tap – install risers as shown. 2. See the engineer's approved list for approved vaults and covers. 3. The low flow by –pass (part numbers 8 -13) shall be installed unless otherwise approved by the Engineering Dept. and shall be a min. 4" in size. If a single P.R.V. is installed, center in vault and change parts Number 4 to 90° flanged ells, and delete part 5. 4. Install fire hydrants only when required by the Engineering Dept. 5. 2" schedule 40 P.V.C. drain pipe shall be installed from a perforated sump canister to an existing drainage system or to daylight. 6. Valves 18" and larger shall be butterfly valves. Valves 16" and smaller shall be resilient wedge gate valves. NO. ITEM 1O MECHANICAL JOINT TEE O2 MECHANICAL JOINT GATE VALVE STD. 877 O3 DUCTILE IRON PIPE — FL. X P.E. ® FLANGED TEE Q FLANGED GATE VALVE STD. 877 © FLANGED COUPLING ADAPTER O7 FLANGED P.R.V. — HIGH FLOW ® FLANGED REDUCER Q FLANGED 90' ELL 10 FLANGED GATE VALVE STD. 877 11 DUCTILE IRON PIPE — FL. X FL. 12 FLANGED COUPLING ADAPTER 13 FLANGED P.R.V. — LOW FLOW 14 3/4" BALLCORP (FORD FB 1000) 15 3/4" BRASS 16 3/4" COMP. X F.I.P. ADAPTER (FORD C14 -33) 17 3/4" M.I.P X HOSE BIBB — BRASS 18 3/4" M.I.P. TEE WITH TWO 2 3/4" F.I.P. X H.B. 7. All pressure reducing valves to be epoxy fused, inside and outside. (See the engineer's approved list) 8. Restrained joints are required for all new construction from CITY OF ROHNE mainline gate valve to vault. Thrust blocks are only required where existing services are being modified and restrained PRESSURE REDUCI� joints are not used. O 3co °°� v d O> 0 E v °- U L N O "D 0 a� U 0 O_ (31 -0 W C O co a .—= CO C Q • O N N v >rn n v •� > v L O (D 0 L 4% 4-0 O j a r o- (D (D X 'U N C C) "O N 3 :� �O O 7 Q - (n co L LEI O Z L Q Q -0 r�- Q 00 X 0 cn N N > N O L ) OO H -�-O 4-0 �U) U N C N O � C) C71 O Y m O N M a L_ 0 o- O 30 v v c Q_ Q U O t W U) a� N O i U_ N •Z _ O N N > N a E +� •aE 0 ° 0 'n .0 0 O 0 o L C V) co CO V 'X E ° C� N "O E O N O 7 t ° a 0 O L L C 3 "p v-. _ c 0 0- O v O N O O N L p N co Qj L "O co 3H O CO U N O L ~ N w 0 w �� ' 0 N C - +r t4- O -0 > 0 CO D U C N t C 0 E o :2 w V -p W� T v 3 ° I O .� Q N 4.0 O C C co 7 =-p O- 0-0-0 N .0. • Q• cn N C +' O -C L ° O -C U) n N O L W N O � N J -p Y O z V who '� � •�LO��Q a(n t- -0 �OO.t •U - p� C•C � D o O "OW N �� d �C (n L t "v C L N� > 0 C N 0-6 LL O O H C p �o p +M 0 Ut 0 L. •a fl- O a a :p N ° N CV O '- U -0 -g— v>V+O'5 0 aL C L N•V O O +�O° pt L 3H 0 �U -0 �- 0— N= N 'L p p a3 O4(nj C� 0 .0 ' -O E N N DI O N co NC °� Q1 Q � &- �+; C � 'QN Q1 N � C C .0 '0 ° N • �V p Ot•� �O U - •a0 p er-0 U U 0 v.- 3° L. O N O O(03, t N Ln co m "O O - Qp - N OL O(V 0 0 Ix , v N M 4 LCD (6 N .0 O" > "O •Q O N Q a O Of U Q O_ Q N i-r (71 L. N ( Q - Q N J _ (n N N C t N (n W� I J .� 4-0 m N 4.0 I of I w O N Q LLJ N J -p N 4-0 who a(n 3� — X (n Q LL LL U Z Ol N O = > LL- U cl LL- L2 %Vi LL- Z NMOHO O Cpoi L O oo 0 �vo U -0 (3) i O U) O C a� Oo 1 L O a O of C U � Q Pe) a� L _ O O O O N N L \ / / \� v N N a \\ 3 0 of Q j ++ O O U) _ O ai •d "O O U O +� O Q N N D7 U) — -0 U � N � O �♦' LOO o N °� N — N �_ O 3 L ,c 0 +� O -O L > O O O U) L (� N � 0) v O A W -O W Q O O N> v N E , + � -c +j / O ° O r w U U O O - /�y W -v wUI i w -1 W \ w^ U X w O 00 U O _ u N U _0 Q (n O !E O O U) • O- ++ 4' Q 4- Q U 00 O u) N _0 4-1 U) 0 0= L � O 0') O •� 0 X U N U O- c: 0-1 &i O N O C - O W U) W +J U N U) J (n X O w L_ O L -0 N X m O Q O N 0- L (n W Q U) -0 • W O N W O X N (� d Z Q O U �, m U O O �O Q O O U ) ; � _rZ • Q O w �b cn cn r � ' o^' C EO U l._ - 0= p O 00 -0 _0 or N w U) w > Cfl _0 Q • •• • • O ++ 0L • 4• O U) Q • :.' - N U U) > a w� O N E > X ' . '*. ° O m A .:.• .p' •� O E C m X ••• ` °...0 • w W O U L m •.' .•• .. �, + w Q) a) •, "' •X Q) GL N n~ • Q) •� O O 0= _ O , U O ' O O O U U -0 0 E N • (n (n O O L U Q .� cn a - O O •0 O O U (n W O Z O O Cfl CITY CF ROHNERT PARK WATER SAMPLING STATION SCALE: NONE DATE: OCTOBER 2010 Approved: STD. — 886 Water services as needed, similar to Std 8631 864 & 865 Install backflow as required. (See note 1) A NN. 12 6 p .. 20' Max. 4" D.I. manifold 4$$ D.I. lateral Tracer Wire: blue insulation, #12 solid copper 90° M.J. X flanged ell with 4" reducing flange with brass bushing & M.I.P. x comp. corp. a • °a . l a (See note 1) ,d v DI A KI \/I F--\A/ (See note 1) 41� dM Face of curb Transition lateral depth from standard main depth to depth of manifold. 4" Gate valve (See Std. 877 or 878) Tapping sleeve or tee I--3" to 6" F. G. r' 1P 24" min., 30" max. M.I.P. thread Tra compression coupling. Wire See engineer's approved list (Sizes as req.) � Jr I \ ° e A I \ e / �,. Tapping saddle set SECTION "A -A" vertically with F.I.P. thread (Sizes as req.) 4" D.I. manifold to be installed with 24" minimum, 30" maximum cover. NOTE: 1. Restrained joints are required for all new construction from gate valve to end of 4" manifold. Thrust blocks are only required where existing services are being modified and restrained joints are not used. 3/8" RAD 1/2" RAD 5/8" RAD 1" DIA 19/32 V /4" TAPPED HOLE, TYP OF 4 1" 1 3/4" -L OUTSIDE HOLE TO BE COUNTERSUNK FOR 1/4" S.S. BOLT W/ SLOTTED HEAD FOR ALLEN WRENC SECTION A -A 7 2•• VV 7/8" DIA -T -- L A 29/32 q �B ni w wI c+�nT�nw� o 0 1/2" PIPE CONSTRUCTION NOTES A. All components of cover and mounting bracket shall be type 316 s.s. B. All fasteners and piping adapters shall be type 316 s.s. C. Existing drinking fountains can be adjusted to regulate flow if water will not exit the opening. D. Field revisions to the cover will be limited to grinding and drilling of the covers to allow flow to exit through the hole in the cover. E. Prior to fabricating covers, shop drawings shall be submitted for review by the City Engineer. F. Direction of drinking fountain discharge shall be changed to eliminate direct sprinkler spray. NOTES 1. Be sure indexing pin is installed and oriented to accommodate the desired mounting 2. To adjust flow, turn adjustment screw counter clockwise to increase flow, and clockwise to decrease flow. HAWS MODEL 5051 LF DRINKING FAUCET 1 1/8" DIA BUBBLER I 3/18" 3/16" — — — — C 2 "X2 "X120" S.S. VARIES SQUARE TUBING I 1 3/4" II MOUNTING HOLE � 7" i I ADJUSTMENT SCREW T i 6 1 /8" i l CAP -- -- — -- 1 3/4" -L OUTSIDE HOLE TO BE COUNTERSUNK FOR 1/4" S.S. BOLT W/ SLOTTED HEAD FOR ALLEN WRENC SECTION A -A 7 2•• VV 7/8" DIA -T -- L A 29/32 q �B ni w wI c+�nT�nw� o 0 1/2" PIPE CONSTRUCTION NOTES A. All components of cover and mounting bracket shall be type 316 s.s. B. All fasteners and piping adapters shall be type 316 s.s. C. Existing drinking fountains can be adjusted to regulate flow if water will not exit the opening. D. Field revisions to the cover will be limited to grinding and drilling of the covers to allow flow to exit through the hole in the cover. E. Prior to fabricating covers, shop drawings shall be submitted for review by the City Engineer. F. Direction of drinking fountain discharge shall be changed to eliminate direct sprinkler spray. NOTES 1. Be sure indexing pin is installed and oriented to accommodate the desired mounting 2. To adjust flow, turn adjustment screw counter clockwise to increase flow, and clockwise to decrease flow. 3/8" RAD 1/2" RAD 1/4" TAPP HOLE, TYP OF 4 SECTION A -A 7/8" DIAL A 29/32" 1" k— 7 B 2" so 1" 1 1/8" DIA I 3/16" HAWS MODEL 5051 LF DRINKING FAUCET — BUBBLER -ft I T ' 4- VARIES 1 3/4" MOUNTING HOLE ADJUSTMENT SCREW 3 5/8" 1 3/4" CAP — — .OUTSIDE HOLE TO BE (- COUNTERSUNK FOR 1/4" S.S. BOLT W/ SLOTTED HEAD FOR ALLEN WRENCH LB D1 A AI I A CUP WASHER NUT 1/2" O.D. S.J. NUT 3/18" C� 2 „x2 °x120° S.S. � SQUARE TUBING �� II I f T� Il I -I- -I SECTION B -B 1/2" PIPE CONSTRUCTION NOTES A. All components of cover and mounting bracket shall be type 316 s.s. B. All fasteners and piping adapters shall be type 316 s.s. C. Existing drinking fountains can be adjusted to regulate flow if water will not exit the opening. D. Field revisions to the cover will be limited to grinding and drilling of the covers to allow flow to exit through the hole in the cover. E. Prior to fabricating covers, shop drawings shall be submitted for review by the City Engineer. F. Direction of drinking fountain discharge shall be changed to eliminate direct sprinkler spray. NOTES 1. Be sure indexing pin is installed and oriented to accommodate the desired mounting 2. To adjust flow, turn adjustment screw counter clockwise to increase flow, and clockwise to decrease flow. 1 3/8" RAD 1 1/2" RAD 1W 1/4" TAPF 4" HOLE, TYP OF 4 L OUTSIDE HOLE TO BE COUNTERSUNK FOR 1/4" S.S. BOLT W/ SLOTTED HEAD FOR ALLEN WRENCH SECTION A -A 7 B 2" so 1" 7/8" DIA -,, A 2sis2� L k- L B PLAN 3/411 2" A HAWS MODEL 5060 LF DRINKING FAUCET BUBBLER T VARIES ADJUSTMENT SCREW 2 1 /8" CAP 1/2" NPT SUPPLY (BY OTHERS) CONSTRUCTION NOTES 3/18" C� 2 11x 2 "x120" S.S. \\ SQUARE TUBING I I � l i i SECTION B -B A. All components of cover and mounting bracket shall be type 316 s.s. B. All fasteners and piping adapters shall be type 316 s.s. C. Existing drinking fountains can be adjusted to regulate flow if water will not exit the opening. D. Field revisions to the cover will be limited to grinding and drilling of the covers to allow flow to exit through the hole in the cover. E. Prior to fabricating covers, shop drawings shall be submitted for review by the City Engineer. F. Direction of drinking fountain discharge shall be changed to eliminate direct sprinkler spray. NOTES: 1. To adjust flow, turn adjustment screw counter clockwise to increase flow, and clockwise to decrease flow. I. Local Streets 20' One Way Street Without Parking See STD 200 B Lane See STD 200 C Neighborhood Street See STD 200 D Minor Street See STD 200 E II. Minor Collector Avenue Main Street III. Industrial Street Industrial Street IV. Major Collector Boulevard V. Arterials Parkway See STD 200 F See STD 200 G See STD 200 H See STD 200 1 See STD 200 J ONE -WAY LOOP STREET WITHOUT PARKING 20' minimum width contiguous sidewalks both sides (typ) 1. Streets are for access to no more than 10 residential units. 2. Street length shall not exceed 200'. 3. Streets shall have contiguous sidewalks on both sides unless otherwise approved 4. 20' Streets shall connect to other streets not less than 36' in width. 5. No flag lots shall connect to 20' streets. 6. Minimum distance of garage face to opposite curb face shall be 42'. 7. Fire hydrants shall be located at each intersection 8. .Maximum height of building fronting roadway not to exceed 2 stories and /or 21 feet max. roof access point. If this height is exceeded, street width curb to curb must be min. 26' clear, required for aerial fire apparatus. NOTE: THE USE OF THIS STREET WIDTH WILL ROUTINELY IMPOSE SPECIAL UTILITY DESIGN REQUIREMENTS, INCLUDING SPECIAL PIPE REQUIREMENTS FOR WATER AND SEWER IF LESS THAN 10' SEPARATION IS PROPOSED. PROPOSED USE OF THIS STREET ON A TENTATIVE MAP MAY REQUIRE DESIGN DETAIL BEYOND NORMAL SCOPE OF TENTATIVE MAPS. NEIGHBORHOOD STREET PARKING 42' Right of Way No co co v w 32' Minimum w U U Q Q Ln C;d 5' 6' 10' 10' 6' 5 Lo C;8 on P T T P • w• wv w .. A"J•` 4 •�'• �t: A•/ '.i1 t.wf•' 1 . t .; N; •' S •• 4 • •• } yY Fs:y:•x+p.. ^•.ir;ry. •i.;b.ke`C, • •n•,o-:N n.`':•.••.::,�y. :.•••. Y .. ,.., ••. ,. THIS STANDARD MAY BE USED ONLY WHEN ALL OE THE FOLLOWING CONDITIONS ARE M ET** 1. Vehicular speeds shall not exceed 25 miles per hour (MPH). 2. Average daily trips (ADT) shall not exceed 1000. 3. Maximum Street length is 1400. 4. Streets shall have access from two directions (no cul —de— sacs). 5. Streets may neck down to 20' at intersections. 6. Streets shall contain residential units only. 7. Sidewalk and curb width is 5 feet. 8. Corners shall have a 20' min. radius. 9. Maximum height of building fronting roadway not to exceed 2 stories and /or 21 feet max. height at roof access point. If this height is exceeded, the minimum clear width parking to parking must be 26' clear, required for aerial fire apparatus. CITY OF ROHNERT PARK NEIGHBORHOOD STREET SCALE: NONE DATE: MARCH 2011 Approved: STD.-200D 46' Right of Way U) CO � w CO w 36' U U Q a_ Q a_ � 5' 8' 1 10' 10' 8' S' 0 � P T T P � w:; .�3•gx.;av,�`C't��"4,�.a.•a�r1 w t • xr:y�'i i:as?tiyr`i i; ;,.wa:L.• r t:�•,.....• _... .a'.�....� a=r•rf'JliO i��. iti.' >�.�.:i.. •v'C: .: r• ::.r +n •R :r�'•a:ky2:_�rf��.._. 'f'_"•.�•_ __s.... 1 . Travel lanes are increased to 12 feet when they are adjacent to curbs (e.g., curb to curb width is 24 feet for no parking and 30 feet for parking on one side only). 2. Sidewalk and curb width is 5 feet. 3. Maximum height of building fronting roadway not to exceed 2 stories and /or 21 feet max. height at roof access point. If this height is exceeded, the minimum clear width parking to parking must be 26' clear, required for aerial fire apparatus. IND US TRIA L S TREE T 54' Right of Way V) U) Li w 48' U U Q a_ Q a_ LO 48 5' 8' 14' 14' 8' 5' LO 48 P T T P •• .�. • ``:y ::..�•`Y.i�: w +i.�>r.�.:iw. \: K..�I• t .. M•,`ti •`'� .��••t1.:°:�i't�, S•s r"t .• y: • ;�t •,�,;,y..«; �.. :b.•;a.:s's'►. "« T ?t�i.`ti �7s:.Fr+'1:•y". MI L 1. Sidewalk and curb width is 5 feet. CITY OF ROHNERT PARK INDUSTRIAL STREET SCALE: NONE DATE: OCTOBER 2010 Approved: STD.-200H PARKWA Y 88' Right of Way 58' 6' 10' 5' 1 1 ' 12' 12' 1 1 ' 5' 10' 6' B T T T T B • .• • •,. rts!' ja., 4'�.�'ry.:.i.�"5''`.•t��ii•.'• .a"{. '.r�a,�ti"C' ;hr�.. � :6. ...,;dye ?.• ?'k:'..` «t �•:_• ;r +r•'C'�� •. y: SHOWN WITH NO MEDIAN 102' Right of Way 6' 10' 5' 1 1 ' 1 1 ' 16 11 ' 11 ' 5' 10' 6' B •�. T T Median T '6�..- ":(�C '.i Sef'n• did': 1 •d'.rw' y:�.. -.;.• �.�.w Vn't•y�.`,3:+.'e..M•t4Y` T B .h•.p.,. .•1',`.; .%. o:. C::i?r.;,,.•�''!L�w'iN••s;w:,, SHOWN WITH 4 LANES, A MEDIAN AND BIKE �.•`•Li ~~,'•�• LANES 1. Travel lanes are 11 feet. The 2 lane configuration with a median is similar to the 4 lane configuration shown above. 2. Sidewalk width is 6 feet and planter strip width is 10 feet measured from face of curb to front of sidewalk. 3. No parking is allowed. CITY OF ROHNERT PARK PARKWAY SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 200J A ALLEY 20' MINIMUM 1' to 2' concrete headers (typ) 4" AC paving (minimum) 4' - 2% min, 57. max 3 #4's placed longitudinally a 6" class A PCC minimum — 2% min, 5% max 6" class 2 aggregate base minimum 1. Alley shall be contained within a commonly owned parcel, joint easements, or within private right of way. 2. Alley lighting shall meet the City's minor street requirements for uniformity ratio and minimum maintained foot candle specifications. 3. Access to 20 or more units will require a minimum 24' alley width for 2 way traffic and 20' for one way traffic. 4. No City utilities (water, storm drainage, sewer) may be constructed in the alleys. 5. Access to alleys will be required to be 24 ft wide for 20 ft beyond the intersection (measured from face of curb), tapering to 20 ft. 6. Adequate backup distance shall be provided. NOTE: 16 ft garage openings require a minimum backup distance of 28 ft. 7. Access to alleys from City Streets shall be through a Std 250A curb cut unless otherwise approved by the City Engineer. 8. Minimum horizontal curve radii shall be 200 ft. NOTE: CURVE RADII MAY NEED TO BE INCREASED DUE TO CLOSE PROXIMITY OF GARAGES TO ALLEY. 9. No dead end alleys will be allowed. 10. Alleys are to be used as secondary access only, with parking provided on primary access road. 11. Maximum alley length is 500'. 48' Radius Bulb APPLICATION: PARKING ALLOWED NO ISLANDS CURVE RADIUS DOWN TO 100' MAY AT BEGINNING OF CUL —DE —SAC. 35' F 48' Radius Bulb 4onument located 3 to 5 ft. Irom island face of curb >n centerline. APPLICATION: NO PARKING MAXIMUM ISLAND DIMENSIONS AS SHOWN. do No 60' 60' 26 120' HAMMERHEAD- ACCEPTABLE ALTERNATIVE HAMMERHEAD R= 40' min. P.R.C. B.C. /E.C. , F.C. R=4� Crown Line — See Notes 3 & 4 �s O 0 T 1001, Radius Pt. 0 outside F.C. See Note 4 N i , 10, � F.c. � 0 �3 4 0 � " I 4 — 4 0 P.R.C. 4 w R = 20' min. �V- N OTES: I 1. Minimum D = 60% Maximum D = 100 °. B.C. /E.C. 2. Minimum curb longitudinal slope = 1% 3. Crown line lies midway between outside 2% 2% and inside returns, along the line radial to the inside return. VARIES 4. Crown line elevation to be shown on the plans. 5. Design shall conform to these requirements F.C. F.C. except as otherwise approved by the City Engineer. 6. See City Standard 204B for alternate knuckle designs. CROWN LINE INSIDE CURBL RETURN 1.50/ 1% OUTSIDE 0 10 4% 7-0 �� CURB .5q T� � 390 RETURN SECTION A -A MAXIMUM & MINIMUM CROSS SLOPES 20' 45' RAID. . 45' RARAID. r 35' radius return Private 20' street with minimum knuckle Outside face of curb radius is 45' from a radius point offset 25' from centerline intersection. No parking allowed. 32' l 30' radius return Standard 32' street with minimum knuckle. Outside face of curb radius is 45' from a radius point offset 25' from centerline intersection. Parking allowed. 35' radius return 24 ft street with minimum knuckle Outside face of curb radius is 45' from a radius point offset 25' from centerline intersection. No parking allowed. 45' RAID. 36' 30' radius return Standard 36' street with minimum knuckle. Outside face of curb radius is 45' from a radius point offset 25' from centerline intersection. Parking allowed. NOTE: Use of these knuckle alternatives (radii offset greater than 10') requires the use of double yellow raised pavement markers following the crown line from the beginning of the outside curve to the end of the outside curve. 45' RAID R =40 ft (typ) Street Barricade _�� Per City STD -211 Q Through Street sign� in this Std.) No Parking sign r � (typ-) I 48' Rc Red }a 20 F TEMPORARY HAMMERHEAD 48" 1 FUTURE THROUGH STREET. M EXTENDED STREET SUBJECT TO INCREASED TRAFFIC 36" T4" x 4" R DW. POST 0 No Parkin (typ-) 0 TEMPORARY CUL —DE —SAC N OTES : 1. Sign shall be reflectorized as per City standard sheeting black on white metal sign with 4" letters. See City Engineer for details. 2. Design shall comply with appendix D of the Fire Code 3. If W is less than 30' on temporary hammerhead, legs shall be 40' instead of 30 . 4. For temporary hammerhead driveway cut, apron and concrete slab are acceptable if consistent with template above. 5. Temporary turnaround shall be used only when specifically approved by the City Engineer. CITY OF ROHNERT PARK TEMPORARY TURNAROUND FOR FUTURE ROAD SCALE: NONE DATE: OCTOBER 2010 Approved: STD. — 206 0.111" METAL AI L RAIL SIGN PER STD 206 3 type N marker signs 8„ x Q" 0 0 0 ROUGH D.F. » POSTS ° 0 0 ° 0 0 o 0 0 0 12 1/4 0 0 0 Z 2' -7" FINISH GRADE 6' —3" O.C. MAX. I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I L_ J L_ L_ J L_ J AS REQUIRED (CURB TO CURB ON DEAD END STREETS) 3 —5" A Cut Washer See NOTE 1. 3' min. 3 I - 1 MAX Tr�_ I r-- E. P. N N _- -I I _ -I I� 2" X 4" RDW. ' _ 1 header treated ' I 1 with an a � I PP roved LO 1 wood preservative I 1 I 1 � I I_ I See NOTE 2. L I� III SECTION A—A NOTES: 1. POSTS SHALL BE PAINTED ONE COAT OF WHITE PRIMER, AND ONE COAT OF WHITE ENAMEL AFTER ERECTION. 2. ALL PORTIONS OF POSTS TO BE INSTALLED BELOW FINISH GRADE SHALL BE TREATED WITH A WOOD PRESERVATIVE APPROVED BY THE CITY ENGINEER. 3. ON DEAD END STREETS, INSTALL TYPE W21 REFLECTORS AT CITY ENGINEER'S DIRECTION. 4. ALL RAIL ELEMENTS TO BE HOT DIPPED GALV. 3 3/16 to 1/16" tolerance 1 1/16" 1 5/16 �\ 100 12 1/4" 3 1/4 I ►- 1 17/32 to 9/16" 0.1 1 1 to nom. Symmetrical about nuetral axis RAIL ELEMENT SECTION 4 1/4 to 4 1/4 to $I I 1 1 1 10 I 1 3/4" X 2 1/2" 1 1 SLOT 1 1 29/32" x 01 1 1 1/8" 1 1 SLOT LAP IN DIRECTION OF TRAFFIC. 5/8" x 1 1/4" BUTTON HEAD, OVAL SHOULDER BOLTS WITH 1 1/4" RECESSED TOTAL HEX NUTS —TOTAL OF 8 PER SPLICE & 4 PER TERMINAL SECTION. RAIL SPLICE SECTION CENTERLINE OR LANE STRIPE THERMOPLASTIC 4" SOLID WHITE LINE TAPER 151 p OO �0 Z'-" / IMPROVED CURB & GUTTER INSTALL TYPE G RAISED PAVEMENT MARKERS AT 24' ON CENTER INSTALL TYPE N MARKER 24' E. P. typ� /010) a OBSTRUCTION INSTALL BARRIER PER CITY STD. 211. INSTALL TYPE C TERMINAL ENDS AT BOTH ENDS OF BARRIERS. 6' F/C F/C LIP OF GUTTER O N L N 21.1' N O N c W It Q T Of U SLOPE Q) 5% 2% � o MAX. MIN. -0 >N Z � Q) N � 62.2• 20' PER m -0 Jc 0 PARKING MIN. STALL � � W � — C3 O p T N = 0 C3 U SLOPE � m � 5% 2% c)- MAX. MIN. c L Q) N 0 II LL z 21.1' O N CITY OF ROHNERT PARK PARKING BAY F/c LIP OF GUTTER SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 213 FL - - , a ° a d d / ° • °d • Q • � SO' (ain,) ..)LI IF II Iy Lv uN-, LI IN-,[ I I ivNiuZ-)Lik, FL F , 14 minimum to _ Stall depth at 17 i i 2' i i i 1/2 lip i Maintain gutter flowline 2% max, in access parking areas 5% max. in other 1 % minimum 6" min. •n. . Section A concrete I I R/W 8;5' S W E 8 sidewalk 1. Stall widths vary — 9' minimum for residential and 10' for commercial 2. Parking bays to be privately owned and maintained. 3. For use on low volume (local or main) streets and /or within short block streets only (300' or less for commercial). 4. Maximum two stalls per lot for single family residential use. 5. Placement of parking bays restricted to areas with adequate sight distance. 6. Surface drainage flows must be maintained within gutter pan and right —of —way. 7. Handicap accessible projects and commercial applications of this standard must must meet all handicap requirements. 8. Minimum distance from end of curb return to first stall shall be 50'. 9. Street lighting Shall meet the city's CITY OF ROHNERT P. minimum street lighting requirements. 10. Street tree spacing shall be per City 450 PARKING BAY standards. TRENCH BACKFILL AND SURFACING EXISTING ROADS 4.5 inches thicker than existing asphalt or to 60" min. Fthe bottom of subgrade 4.5" min. thicker VARIES (3 ft. min.) depth than existing asphalt VARIES (3 ft. min.) PLAN 2 ft. min. 2 ft. min. VARIES 2 ft. min. VARIES (3 ft. min.) NOTES ON PAGES 5 -7 THIS STANDARD Page 1 of 7 finish grade 6 " ASPHALT CONCRETE MINIMUM. Bedding per page 3. this standard 2 ft. rd in. VARIES (3 ft. min.) Limits of Excavation 6" deep T— Section Limits of Restoration CITY OF ROHNERT PARK STANDARD TRENCH DETAIL TRENCH BACKFILL AND SURFACING SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 215 24" min. CLSM \` jREQUIRED. SECTION 4.5" min. thicker VARIES (3 ft. min.) depth than existing asphalt VARIES (3 ft. min.) PLAN 2 ft. min. 2 ft. min. VARIES 2 ft. min. VARIES (3 ft. min.) NOTES ON PAGES 5 -7 THIS STANDARD Page 1 of 7 finish grade 6 " ASPHALT CONCRETE MINIMUM. Bedding per page 3. this standard 2 ft. rd in. VARIES (3 ft. min.) Limits of Excavation 6" deep T— Section Limits of Restoration CITY OF ROHNERT PARK STANDARD TRENCH DETAIL TRENCH BACKFILL AND SURFACING SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 215 FULL DEPTH OF - EXISTING ASPHALT WITH MINIMUM OF 4 INCHES BORE HOLES 36" MIN 12 $$ MIN T- EXISTING AC SECTION po N Ir- PLAN Page 2 of 7 TRENCH WIDTH FOR HDPE PIPE PIPE SIZE* TRENCH WIDTH (MIN1. 15 36" 18 48" 24" 54" 30 60" 36" 72" PIPE MUST BE CENTERED IN THE TRENCH. *INSIDE DIAMETER SUBGRADE � TYPE C (STREETS UNDER CONSTRUCTION) TRENCH BACKFILL (TYPE TO BE SHOWN ON THE PLANS) FINISH GRADE CL2 AB:': 11= T III 195% R.C. I III 1 2„ III � Ell % 2 LIFTS/ IIII. . II =11 11= VIII TRENCH-.-.*. �I BACKFILL . II- CDF. III I �I TYPE B (SHOULDER AREAS) NATURAL GROUND NATIVE w MATERIAL Q REMOVED „ 30 FROM UPPER z 30” z 85% R.C. _, g II I III � TRENCH BACK FILL TYPE D (PUBLIC UTILITY EASEMENT) OUTSIDE STREET AREA NATIVE MATERIAL REMOVED FROM UPPER 30" 85% R.C. NATIVE MATERIAL . 85% R.C, . . TYPE E (PUBLIC UTILITY EASEMENT) UNDEVELOPED AREAS TRENCH BACKFILL TRENCH BACKFILL �III� -III (SEE ABOVE) (SEE ABOVE) �III� IIII „ � illy= 9„ MIN. 9 MIN. NOTE 3 15 MAX. 15" MAX. BEDDING MATERIAL 90% R.C. GEOTEXTI LE, M I RAFI 140NC OR EQUAL - III- El 6" MIN . DRAIN ROCK III 4 MIN. III - NOTE 2 Ii iii STABLE TRENCH UNSTABLE TRENCH PIPE BEDDING 1. RELATIVE COMPACTION IS DESIGNATED RC. 2. 1/4 PIPE O.D. MINIMUM WHEN EXCAVATION IS IN ROCKY GROUND. 3. PIPE DIAMETER 18" OR LESS: 6" MIN., 9" MAX. PIPE DIAMETER GREATER THAN 18": 9" MIN., 12" MAX. SEE TABLE ABOVE FOR HDPE PIPE TRENCH WIDTHS. Page 3 of 7 STREET STRUCTURAL SECTION SHALL BE AS SHOWN ON PLANS SUBGRADE SEE NOTES BELOW ATIVE TRENCH BACKFILL (90% R.C.) / z X N � N 4" MIN.- SEE NOTE 2, PAGE 3 TYPE F SEE NOTE 3, PAGE 3 BEDDING MATERIAL SEE PG.3 (NEW STREETS UNDER CONSTRUCTION) NOTES: 1. ROCKS EXCEEDING 6$$ SHALL NOT BE PERMITTED WITHIN THE TRENCH SECTION. 2. THE MAXIMUM DEPTH OF NATIVE BACKFILL MATERIAL SHALL NOT EXCEED 10', UNLESS THE STREET IS EXCAVATED A UNIFORM DEPTH FROM FACE OF CURB TO FACE OF CURB. 3. EMBANKMENT CONSTRUCTION METHODS SHALL BE USED. ALL SLOPES MUST BE KEYED -IN A MINIMUM OF 1 ' AS THE TRENCH IS BACKFILLED. 4. THE MINIMUM EQUIPMENT REQUIRED FOR COMPACTION OF NATIVE BACKFILL MATERIAL SHALL CONSIST OF A SHEEPSFOOT VIBRATORY ROLLER WITH A MINIMUM DRUM WIDTH OF 48 ", A MINIMUM GROSS WEIGHT OF 4600 LBS, OR MUST MEET APPROVAL OF THE CITY ENGINEER. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE PRIVATE SOILS ENGINEER AND THE CITY INSPECTOR 48 HOURS PRIOR TO EXCAVATION. 6. THE PRIVATE SOILS ENGINEER SHALL PROVIDE TESTING AND OBSERVATIONS ON A FULL TIME BASIS DURING ALL NATIVE BACKFILLING OPERATIONS. THE PRIVATE SOILS ENGINEER IS RESPONSIBLE FOR THE VERIFICATION OF ALL NATIVE BACKFILL WORK INCLUDING COMPACTION AND UNIFORM MOISTURE CONDITIONING, AND THAT MOISTURE CONTENT IS ABOVE OPTIMUM MOISTURE TO THE EXTENT APPROPRIATE FOR THE NATIVE MATERIAL BEING USED. Page 4 of 7 1. In streets that are less than five (5) years old or have a Pavement Condition Index (PCI) greater than 85, the City Engineer reserves the right to deny any street excavation or require repairs that are over and above these specifications. 2. The Contractor shall at all times so conduct his /her work as to assure the least possible disruption to the motoring traffic and adjacent residents and businesses. 3. During peak traffic and during times when no work is preformed on the new installation, plates shall be in place and the street opened to full traffic flow. Plates shall be placed across the trench in a secure fashion not to move or vibrate under traffic conditions. 4. Avoid weakening or destroying the existing pavement around an excavation with heavy construction equipment, stockpiling, or delivery of materials, etc. No stockpiling of backfill or road building materials is permitted on the pavement. 5. The excavated material from the trench shall be removed from the site. Backfilling shall begin immediately after completion of the designated utility work. 6. Granular backfill shall be used around the pipe and as pipe bedding. Bedding material shall be compacted to at least 90% relative density with moisture control (not on standard Proctor). Lift thicknesses should be less than or equal to 6 inches. 7. PIPE BEDDING and TRENCH BACKFILL shall be free of asphaltic material 8. PIPE BEDDING for slopes less than or equal to 8% shall have a minimum sand equivalent value of 30 and shall conform to the following grading: 1 " 3/4" 3/8" #4 #200 100% 90 -100% 65 -100% 30 -100% 0 -15% 9. Pipe bedding for slopes greater than 8% shall have a minimum sand equivalent of 30 and shall conform to the following grading: 1 " 3/4" 3/8" #4 #30 #200 100% 90 -100% 65 -100% 30 -100% 0 -100% 0 -15% 10. Trench backfill shall be compacted to at least 90% relative density with moisture control (not on standard Proctor). Lift thicknesses should be less than or equal to 12 inches. Compaction testing by an approved soils testing laboratory is required if granular trench backfill is used. 11. TRENCH BACKFILL shall conform to the following grading and have a minimum sand equivalent value of 25: 3" #4 #30 100% 40 -100% 10 -100% Page 5 of 7 12. CLSM (Plowable —fill) shall be used in all trenches within existing streets or shoulder areas. The depth shall be a minimum of 3 feet below the roadway aggregate base or from the pipe backfill to the roadway aggregate base, whichever is less. *Trench backfill may be used on an exception basis with the permission of the City Engineer. Compaction testing shall be provided by the contractor. 13. CLSM shall be a mixture of Portland cement, sand, 1" maximum coarse aggregate, air entraining agent, and water, batched by a ready —mixed concrete plant and delivered to the jobsite by means of transit mixing trucks. CLSM may also contain class f pozzolan (fly ash). CLSM shall be used in all roadways and be free of asphaltic material. 14. CLSM (Plowable —fill) The maximum 28 —day strength is 60 psi. The following combination of material, or an equivalent, may be used to obtain the desired "flowable— fill ". Cement 42 Ib /CY (0.47 sack); Water 235 Ib /CY(39 gallons or as needed); Coarse Aggregate1700 Ib /CY; Sand (ASTM C- 33)1845 Ib /CY. 15. The consistency of CLSM shall be such that all trench voids are filled with minimum rodding or vibrating but not so wet as to cause excessive shrinkage. 16. Permanent pavement may be placed directly upon the CLSM as soon as it has consolidated for the surface to withstand the process of paving without displacement. The surface of the CLSM shall be firm and unyielding. Any visible movement vertically or horizontally of the CLSM under the action of construction equipment or other maximum legal axle loads shall be considered as evidence that the control density fill does not meet this requirement. The contractor shall provide trench plates to allow traffic flow for all locations until control density fill is ready to be paved. 17. Asphalt repair shall extend 5 feet minimum from either side of the trench wall. Transverse patches on arterial and collector streets shall be overlaid across the entire street width for a distance of five (5) feet minimum on all sides of the trench. 18. The replacement asphalt shall be a minimum of 4.5 inches deeper than the existing asphalt or full depth replacement of asphalt in lieu of the aggregate base and asphalt, whichever is less. *A two inch overlay of the roadway surface may be substituted for this replacement asphalt at the discretion of The City Engineer. Conforms shall meet City Standards. 19. AGGREGATE BASE shall conform to the requirements of the City Standard Specifications, Class 2 aggregate base. 20. Asphalt concrete shall conform to the requirements of Section 39 of the State Standard Specifications. 21. A thickened T section of asphalt shall be placed an additional 6 inches deep to 2 feet either side of the trench wall. 22. Pavements shall be removed by saw cutting or grinding. Neatly cut or grind pavement after trench is backfilled to subgrade. 23. Any damage, even superficial, to the existing asphalt surface in the vicinity of the work shall be repaired at the expense of the Contractor, including but not limited to gouges, scrapes, outrigger marks, backhoe bucket marks, etc. A slurry seal type covering will be considered the minimum repair. Patching may be required, at the discretion of the City Engineer. 24. Existing pavements should be removed to clean, straight lines parallel and perpendicular to the flow of traffic. Do not construct patches with angled sides and irregular shapes. All repairs shall be full lane width. Joints shall be placed at lane lines. Page 6 of 7 25. Utility trench patches shall avoid excessive joints. a. When a proposed cut is within ten feet of an existing patch, extend the new patch to the existing patch. b. Patches shall be rectangular and maintain the same width throughout the length of the patch. c. If a patch is done within an existing patch make the boundaries of the patches coincide. d. Avoid frequent changes in width of patches. e. Do not leave strips of pavement less than one —half lane in width from the edge of the new patch to the edge of an existing patch or the lip of the gutter. f. The patched area must include any damage due to trenching operations within 10 feet of the patch. 26. A tack coat shall be applied to all edges of the existing asphalt before placing the new pavement. After placing the new asphalt, all seams (joints) between the new and existing pavements shall be sealed with rubberized crack seal material. 27. Patch slope and grade must match existing pavement. Patches should have a smooth longitudinal grade consistent with the existing roadway. Patches should also have a cross slope or cross section consistent with the cross slope of the existing roadway. 28. The finish pavement must be flush with the adjacent surfaces. The finished surface of the street repair shall be tested with a twelve— (12 —) foot straightedge parallel to the centerline or perpendicular across joints. Variations measured from the testing face of the straightedge to the surface of the street repair shall not exceed 1/8 inch in 12 feet longitudinally and 1/4 inch in 12 feet transversely. 29. The contractor is required to provide material testing for each phase of the work and at no cost to the City. The testing firm chosen to perform this work for the Contractor must be qualified and identified on the Permit application. 30. When the final surface is not immediately installed, it shall be necessary to place a temporary asphalt surface on any street cut opening. The temporary surface installation and maintenance shall be the responsibility of the Permittee until the permanent surface is completed and accepted. It shall be either a hot mix or cold mix asphalt paving material. Temporary surfaces shall be compacted, rolled smooth, and sealed to prevent degradation of the repair and existing structures during the temporary period. Permanent patching shall occur within two (2) weeks except as outlined in the Permit. Trenchplate may be used for 24 hours maximum. 31. Removal and replacement of unsatisfactory work shall be completed within fifteen (15) days of written notification of the deficiency unless deemed an emergency requiring immediate action. In the event the replacement work has not been completed, CITY ENGINEER will take action upon the contractor's bond to cover all related costs. Page 7 of 7 20' UTILITY & ACCESS EASEMENT 12' MINIMUM 2 "x8" REDWOOD HEADER (TYP.) z 2 7o a a a 2 "x4 "x24" LONG REDWOOD STAKE 4' OC WITH 3 -10d GALV. NAILS (TYP.) 0.67' COMPACTED BLUE SHALE (TYP.) STD. CURB & GUTTER TYPE B SOIL STABILIZATION FABRIC (TYP.) (SEE NOTE N0. 1) 20' SEWER & ACCESS ESM 12' MINIMUM �2% 4 a 4 1. SOIL STABILIZATION FABRIC SHALL BE MIRAFI 500 -X OR EQUAL. 2. ALL ACCESS ROADS HAVING A GRADE OVER 5% SHALL BE PAVED WITH 6 INCHES OF CLASS II AGGREGATE BASE AND 2 INCHES OF ASPHALT CONCRETE. 3. ALL ACCESS ROADS HAVING A CURVE WITH A RADIUS OF LESS THAN 100 FEET SHALL BE INCREASED IN WIDTH TO 20 FEET WITH A MINIMUM INSIDE RADIUS OF 20 FEET. 4. A HAMMERHEAD TURNAROUND MAYBE REQUIRED AT THE END OF THE UTILITY ACCESS ROAD AT THE DISCRETION OF THE UTILITIES DEPARTMENT. 5. THE SUBGRADE SHALL BE COMPACTED TO 95% RC. ° 0 U 100' A Parking 04 12' No Parking Bus Pod Sidewalk A On streets with parking This bus stop is "near side" of intersection. "Far side" bus stop is mirror image with the same dimensions. A "far side" bus stop is preferable. See City Std. -222 for section A —A ° 3 50' 60' c co A 0 U Bus Pod N Sidewalk A oda�,e PGGo o�par 8u On streets without parking Refer to County Std. This bus stop is "far side" of intersection. "Near side" bus stop is mirror image with the same dimensions. A "far side" bus stop is preferable. N otes: 1. Bus benches and shelter shall be located behind the sidewalk or in such a manner that a minimum 5'clear sidewalk is provided. 2. Paved section at bus stop to be as per Std. 222. 3. Design of bus stops shall be done in CITY OF ROHNERT PARK consultation with the transit agency and 9 y as approved by the City Engineer BUS STOP AT INTERSECTION SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 220 L ^ 00 U (1- (n O Z O ' O II N � N +-' '— � N N Q +� N I u O N '� !E C3 �- LJ -0 O — � Q Q Q U L- O U U a U) ) O U N 0 3� CL v p U -0 U) ^ -0 N N N N I O > • ^ a) �L -0 o 0- U) o � = Q >1 E -1--i U) •- �Z ^ ^ c U w U) O W n l W co +^/ -0 ' v i • - ) M W �I T VJ co U O Z N Z -Y U 0 O Z CITY CF ROHNERT PARK 0') 0 BUS STOP IN MIDDLE OF BLOCK SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 221 6" 12' on S FEATHER A.C. (WHERE APPLICABLE) 8" CLASS "A" P.C.C. da. a � 2% SLOPE Id a a. SEE NOTE 4. g" � 8" CLASS II AGGREGATE BASE COMPACTED TO 95% SECTION A —A REFERENCE STD. -220 8c STD. -221 NOTES: 1. Expansion joints & score marks to match existing curb gutter & sidewalk. 2. Use Class A P.C.C. 3. Construct subdrains when required by City Engineer. 4. Reinforcing steel required in concrete: #4 @ 12" O.C. each way, or #5 @ 16" O.C. each way. CITY OF ROHNERT PARK_ CONCRETE BUS PAD DETAIL SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 222 CLASS II AB SIDEWALK DIMENSIONS FOR; LANES, MINOR STREETS, AVENUES, NEIGHBORHOOD STREETS, AND INDUSTRIAL STREETS NOTES: 1. MEANDERING SIDEWALKS AND PLANTER STRIPS TO BE REVIEWED ON A CASE -BY -CASE BASIS PER CITY ENGINEER OR PLANNING COMMISSION. 2. SCORING PATTERN SHOULD MATCH ADJOINING SIDEWALKS. SEE NOTE 4 1' MIN 4.5' SIDEWALK TO BE 4 "CLASS A P.C.C. ON 4" SAND OR CLASS II A.B. SIDEWALK AND PLANTER STRIP DIMENSIONS FOR FOR MAIN STREETS NOTES: 1. MEANDERING SIDEWALKS AND CONTIGUOUS SIDEWALKS, TO BE REVIEWED ON A CASE -BY -CASE BASIS PER CITY ENGINEER OR PLANNING COMMISSION. 2. SCORING PATTERN SHOULD MATCH ADJOINING SIDEWALKS. 3. TREE WELLS ARE MINIMUM 4' x 4'. 4. ENCROACHMENT PERMIT REQUIRED FOR AWNINGS. 0 10' Planter Strip 6' Sidewalk SIDEWALK TO BE 4 "CLASS A P.C.C. ON 4 "SAND OR CLASS II AB SIDEWALK AND PLANTER STRIP DIMENSIONS FOR PARKWAYS NOTES: 1. MEANDERING SIDEWALKS AND CONTIGUOUS SIDEWALKS TO BE REVIEWED ON A CASE —BY —CASE BASIS PER CITY ENGINEER OR PLANNING COMMISSION. 2. SCORING PATTERN SHOULD MATCH ADJOINING SIDEWALKS. 9 q p (ismP del 1 5'-." MIN tre � ell 4' minimum clearance required i LAC � SIDEWALK TO BE 4" CLASS A P.C.C. ON SECTION A 4" CLASSN 11 OR AB AB 1. Street tree planting shall be in accordance with City standard. 2. Tree wells are the minimum size called for in the Street Tree List Vol. 1 3. Weakened planes, score marks and expansion joints shall be per standard 235 or may be in a 4 ft. by 4 ft. pattern as shown. 4. Street tree selections shall comply with City Street Tree List Vol. 1. Ni nTP-c 1. As site conditions dictate, Case A through Case G curb ramps may be used for corner installations similar to those shown in STD. -232E and STD. -232F. The case of curb ramps used in STD. -232E do not have to be the same. Case A through Case G curb ramps also may be used at mid block locations, as site conditions dictate. 2. If distance from curb to back of sidewalk is too short to accommodate ramp and 4' -0" platform (landing) as shown in Case A, the sidewalk may be depressed longitudinally as in Case B, or C or may be widened as in Case D. 3. When ramp is located in center of curb return, crosswalk configuration must be similar to that shown for STD. -232F. 4. As site conditions dictate, the retaining curb side and the flared side of the Case G ramp shall be constructed in reversed position. 5. If located on a curve, the sides of the ramp need not be parallel, but the minimum width of the ramp shall be 4' -0 ". Indicate detail landings, and relation to crosswalk. 6. Side slope of ramp flares vary uniformly from a maximum of 10% at curb to conform with longitudinal sidewalk slope adjacent to top of the ramp, except in Case C and Case F. 7. The curb ramp shall be outlined, as shown, with a 12" wide border at the level surface of the sidewalk with 1/4" grooves approximately 3/4" on center. See STD. -232G, grooving detail. 8. Transitions from ramps to walks, gutters or streets shall be flush and free of abrupt changes. 9. Maximum slopes of adjoining gutters, the road surface immediately adjacent to the curb ramp and continuous passage to the curb ramp shall not exceed 5 percent within 4' -0" of the top or bottom of the curb ramp. 10. Curb ramps shall have a detectable warning surface that extends the full width and 3' -0" depth of the ramp. Detectable Warning Surfaces shall conform to the details on STD. -232G and the requirements in the Special Provisions. Detectable warning materials should contrast at least 70% with adjacent surfaces. The material used to provide contrast shall be an integral part of the walking surface and shall differ from adjoining walking surface in resiliency or sound —on —cane contact. ADAAG 4.29.2. 11. The edge of the detectable warning surface nearest the street shall be between 6" and 8" from the gutter flowline. 12. Sidewalk and ramp thickness, "T ", shall be 4" minimum. 13. Utility pull boxes, manholes, vaults and all other utility facilities within the boundaries of the curb ramp will be relocated or adjusted to grade by the owner prior to, or in conjunction with, curb ramp construction. If utilities are not relocated within the curb ramp, the required surface conditions shall be maintained, slip resistance and contrasting color. 14. For retrofit conditions, removal and replacement of curb apron will be at the Contractor's option, unless otherwise shown on project plans, but in all cases must meet current standards. 15. The surface of each curb ramp and its flared sides shall be stable, firm and slip resistant. Indicate finish surface, including concrete or other approved surface materials. The detectable warning material also needs to be slip resistant, measured at the top of the domes surfaces and the surface between domes. Slip resistance shall be measured in accordance with ASTM C1028 and shall achieve a static coefficient of friction of 0.8 or greater, wet or dry. ADAAG 4.5. 16. The surface of each curb ramp and flared sides shall be of contrasting finish from that of the adjacent sidewalk. CBC 1 127 B.5.6. Provide 70% contrast per ADAAG 4.29.2. 17. Curb ramp shall have a minimum of surface warping and cross — slope. CBC 1127 B.5.2. 18. If possible the centerline of the curb ramp shall be parallel with the crosswalk. A Sidewalk v w See Notes See N ° 10 and 11 Note 7 See Notes 15 & 16 See Note 18 Front edge OOOUO 000000C of sidewalk 00000000'' x 000 0006") 00,0100- 0000 0000 10% Max 0000 00000 10% Ma x 000000 0000 at curb 000000 oaaa at curb See Note 17 A See Notes 8 & 9 4' -0" Min nn�r n See Note; 15 & 16 B Retaining curb if necessary at 6" Typ edge of sidewalk n" Min :e 7 Les 6 of 31 / B � See Notes 10 and 11 See Note 17 See Notes 8 & 9 See Note 18 n n � r n Gutter Retaining curb flowline Top of ramp 4' -0" Min if necessary Rounded Top of ramp Gutter �4' -0" Min i See Note 9 flowline Rounded 110 27 Max Tj ............ 8.33% Max 2� Max 8.33 Max T J See Note 9 SECTION A -A SECTION B -B Depress entire sidewalk as required See Notes 15 & 16 C 6 11 Typ 5-0" Min 8.3 3 0000000000 I 000000c 0000000000 000000c 0000000000 000000c ® 00000000 000000c Sidewal 2� Max 00000000 a 000000c 8.33 8 33� 00000000 � 00000000 000000c 000000c X 0 b� Max v 000000c 000000c c Max See No 00000000 00000000 N � x v .. x � a 0000000000 0 0000c NM L Front edge of sidewalk C See Note 17 See Nc See Notes 8& 9 n n(-% r 710000 000000 000000 000000 000000 000000 000000 15 & OMax 000000 000000 000000 0000 0 000000 000000 000000 x 0000 _,00001 10 ron t at curb o o 0006 at curb re dge 00 000 oo °o 0o idew :e 7 Les 6 of 31 / B � See Notes 10 and 11 See Note 17 See Notes 8 & 9 See Note 18 n n � r n Gutter Retaining curb flowline Top of ramp 4' -0" Min if necessary Rounded Top of ramp Gutter �4' -0" Min i See Note 9 flowline Rounded 110 27 Max Tj ............ 8.33% Max 2� Max 8.33 Max T J See Note 9 SECTION A -A SECTION B -B Depress entire sidewalk as required See Notes 15 & 16 C 6 11 Typ 5-0" Min 8.3 3 0000000000 I 000000c 0000000000 000000c 0000000000 000000c Retaining curb if T Gutter necessary flowline 2% Max T See Note 9 SECTION C -C 8.33% Max x Retaining curb if necessary at edge of sidewalk Sidewalk See Note 7 See Notes \'See Note 17 10, 11 & 18 SEE STD. -232A FOR ALL NOTE REFERENCES. ® 00000000 000000c 00000000 a 000000c p :2 00000000 � 00000000 000000c 000000c 0 b� 00000000 00000000 000000c 000000c cV 00000000 00000000 N 000c o 0000c 0000000000 0 0000c Front edge of sidewalk C See Note 17 See Notes 8& 9 n n(-% r Retaining curb if T Gutter necessary flowline 2% Max T See Note 9 SECTION C -C 8.33% Max x Retaining curb if necessary at edge of sidewalk Sidewalk See Note 7 See Notes \'See Note 17 10, 11 & 18 SEE STD. -232A FOR ALL NOTE REFERENCES. A Sidewalk ��Q o C N 0 See Note 7 I See Notes 2% Max 15 & 16 .. 0000 0000 F\�r °o °o °o °o �'`� x 0 00 0 0000 p 00 10% Max 0000 0 0 0 °°0 000000 0000 at curb 000000 0000 nnnnnn nnnn A 1 See Note 17 4' -0" Mln 10% Max See Notes at curb 10, 11 & 18 Front edge of sidewalk Planting 10% Max area, min \ at cur 3' x 3' --1'- b See Notes 8 & 9 See Note 171 See Notes 8 & 9 r C: � � See Sidewalk N:2 Note 7 w 0 See Notes 15 & 16 2% Max 10% Max at curb ront edge b 1000000 000000 of sidewalk 0000 0 �0000� 000000 x 0000 ,0000� v °000 Retaining Curb 0000 �00000� '00000 1000000 o0 I 000 00 000 00 (both sides of ramp) F I See Note 17 See Notes 4' -0" Min 10, 11 & 18 A " 6 Typ t Gu ter Top Gu r of ramp 4' -0" Min Rounded See Note 9 00 es I 2% Max Tj 8.33% Max SECTION A —A SEE STD. -232A FOR ALL NOTE REFERENCES. See Note 4 Gutter Top Gutter of ramp 4' -0" Min Rounded � See Note 9 2% Max Tj 8.33% Max .SECTION A -A SEE STD. -232A FOR ALL NOTE REFERENCES. A A Sidewalk q X Sidewalk See o Front edge See - X Note 7 _ of sidewalk Note 7 ° N See Notes 15 & 16 2% Max 6" Typ 10% Max See Notes 15 & 16 6 Typ at curb 0 " 000000 000000 OOOOOO ������ 000000 000000, e t a i n i n g Curb v N 000000 aaaaaa 000000 000000 ron t edge g • 0000 0 000000 0000 X 0000 (both sides of ramp) v 0 000000 000000 0000 0 000000 of sidewalk E 00000000 n 00000 0000 0000 0000 .� 0000 0000QQ 0000 O 0000x7 0000 0000 0000 OOOOQQ 000000 00000000 000 O 000000 0000 0 0000 000040 000000 000 See Note 17 �� See Note 17 See Note 17 See Note 17 See Notes 4 —0 Min See Notes Retaining Curb 4' -0" Min See Notes 10, 11 & 18 8 & 9 A 10 11 & 18 , See Notes A 8 & 9 nnrr r See Note 4 Gutter Top Gutter of ramp 4' -0" Min Rounded � See Note 9 2% Max Tj 8.33% Max .SECTION A -A SEE STD. -232A FOR ALL NOTE REFERENCES. See Note 17 Sidewalk Nci _0 p •o �O � '� - See Notes o c�ee 8 & 9 cv vara�rg Sidewalk See Note 19 See Note 17 �a F�aC e e F�ac See Notes P 8 & 9 Crosswalk if provided See Note 17 TYPICAL TWO-RAMP CORNER INSTALLATION See Note 1 r Gutte GutteTop e of ramp 4' -0" Min See Note Rounded 9 2% Max Tj 8.33% Max SECTION A -A SEE STD. -232A FOR ALL NOTE REFERENCES. CITY OF ROHNERT PARK CURB RAMPS TYPICAL TWO-RAMP CORNER INSTALLATION SCALE: NONE DATE: OCTOBER 2010 Approved: STD.-232E 24" Straight Curb See Note 17 See Note 19 ECR P HOC � Sidewalk See Notes 15 & 16 v L BCR ee Notes See Note 17 g & g 24" Straight Curb Crosswalk if provided TYPICAL ONE -RAMP CORNER INSTALLATION See Notes 1 and 3 Gutter flowline Top of ramp \ 4' -0" Min Rounded See Note 9 2% Max T� 8.33% Max SECTION A -A USE OF THIS CURB RAMP REQUIRES APPROVAL OF CITY ENGINEER SEE STD. -232A FOR ALL NOTE REFERENCES. CITY OF ROHNERT PARK CURB RAMPS TYPICAL ONE -RAMP CORNER INSTALLATION SCALE: NONE DATE: OCTOBER 2010 Approved: STD.-232F Ap roximately 1 /4„ 3/4 F-,,,' -7 F-,377 F p D D GROOVING DETAIL 0.2 0.45„ Top Dia T Indicate requirements 0.9„ for slip resistance at Base Dia top of domes and surface between domes. See Note 15 1.67" (IDSA IR 11 B -4) Center to center spacing 0 (0 Indicate requirements for slip resistance at top of domes DO DO and surface between domes. See Note 15 2.35 apart See RAISED TRUNCATED DOME PATTERN ( DETECTABLE WARNING SURFACE See Note 10 RAISED TRUNCATED DOME Limit of pay Rounded 4' -0" Min #"� Note 14 See T� Note 9 RETROFIT DETAIL Existing curb and sidewalk SEE STD. -232A FOR ALL NOTE REFERENCES. Curbs shall be perpendicular to aised Island crosswalk (Typ.) See Note 17 Slope passageway B STD. -232A (Typ.) to drain 2% max -*--See Note 5 Curb ramp, See Note 7 --Curb ramp, See Note 10 �� See Note 7 °o°o °o a °o °o �� See Note 10 0 Q) 0000OO 0000OO O ° -0 See Note 7 - v)'> - 000 000 - - �'> - See Note 7 00 00000 000000 LO � (Q0 U00 o0 UQ See Note 5 Detectable B warning surface, See Notes 2 and 4 � � v a) a) v 3 _ai a5 3 aD > > aD _0 a v _0 cn co Raised Island TYPE A PASSAGEWAY Clear passageway Var 4 -0 Min 6 Typ Surface of raised island _L Retaining curb T SECTION B -B N OTES 1. Sidewalk, ramp and passageway thickness, "T ", shall be 4" minimum. 2. Minimum width of passageway through raised islands shall be 4' -0", except as approved by city engineer for locations where right of way restrictions, natural barriers, or other existing conditions create an unreasonable hardship, the clear width of the passageway may be reduced to 3' -0 ". 3. For details of grooving used with Case CM curb ramp, see STD 232G, grooving detail. 4. For details of detectable warning surfaces, see STD 232G. 5. Where an island passage way length is less than 6' -0", the detectable warning surface shall extend the full width and full depth of the passage way length. Where an island passage way length is greater than or equal to 6' -0 ", but less than 8' -0 ", a detectable warning surface shall extend the full width and 2' -0" depth of the passage way length. Where an island passage way length is greater than or equal to 8' -0 ", a detectable warning surface shall extend the full width and 3' -0" depth of the passage way length. 6. For Case CM curb ramp (STD 232K), the edge of the detectable warning surface nearest the street shall be between 6" and 8" from the gutter flowline. 7. Transitions from ramps to walks, gutters or streets shall be flush and free of abrupt changes. 8. Maximum slopes of adjoining gutters, the road surface immediately adjacent to the curb ramp and continuous passage to the curb ramp shall not exceed 5 percent CITY OF R PARK within 4' -0" of the top or bottom of the curb ramp. 9. Utility pull boxes, manholes, vaults and all other utility CURB RAMP AND ISLAND PASSAGEWAY facilities within the boundaries of the curb ramp will TYPE A PASSAGEWAY be relocated or adjusted to grade by the owner prior to, or in conjunction with, curb ramp construction. SCALE: NONE DATE: OCTOBER 2010 10. For additional curb ramp notes and details, Approved: STD.-232H see STD. -232A through STD. -232G. Detectable Warning aised Island Surface, See Notes Slope passageway 2 and 4 to drain 2% max See Note 17 STD. -232A See Note 7 B Curbs shall be (Typ. if on street perpendicular to arking allowed) 711r-e%11111A1^111 (T,.r, � See Note 7 �� v W ......... Curbramp, _� _ • ••••••••• X See Note 10 n o oL ......... . B See Note 5 v � 3 a� a� > a TYPE B PASSAGEWAY Clear passageway Var 4' -0" Min 6 Typ Surface of raised island Retaining curb T N OTES SECTION B - B 1. Sidewalk, ramp and passageway thickness, "T ", shall be 4" minimum. 2. Minimum width of passageway through raised islands shall be 4' -0", except as approved by city engineer for locations where right of way restrictions, natural barriers, or other existing conditions create an unreasonable hardship, the clear width of the passageway may be reduced to 3' -0 ". 3. For details of grooving used with Case CM curb ramp, see STD 232G, grooving detail. 4. For details of detectable warning surfaces, see STD 232G. 5. Where an island passage way length is less than 6' -0 ", the detectable warning surface shall extend the full width and full depth of the passage way length. Where an island passage way length is greater than or equal to 6' -0 ", but less than 8' -0 ", a detectable warning surface shall extend the full width and 2' -0" depth of the passage way length. Where an island passage way length is greater than or equal to 8' -0 ", a detectable warning surface shall extend the full width and 3' -0" depth of the passage way length. 6. For Case CM curb ramp (STD 232K), the edge of the detectable warning surface nearest the street shall be between 6" and 8" from the gutter flowline. 7. Transitions from ramps to walks, gutters or streets shall be flush and free of abrupt changes. 8. Maximum slopes of adjoining gutters, the road surface immediately adjacent to the curb ramp and continuous passage to the curb ramp shall not exceed 5 percent within 4' -0" of the top or bottom of the curb ramp. 9. Utility pull boxes, manholes, vaults and all other utility facilities within the boundaries of the curb ramp will be relocated or adjusted to grade by the owner prior to, or in conjunction with, curb ramp construction. 10. For additional curb ramp notes and details, see STD. -232A through STD. -232G. Curb ramp, See Note 10 Raised Island Detectable Warning Surface, See Notes 2 and 4 vW o° U Note 7 See Note 5 See Note 7 See Note 5 v \,Slope passageway v N to drain 2% max 3 a� a� > _0 v TYPE C PASSAGEWAY Curbs shall be perpendicular to crosswalk (Typ.) See Note 5 See Note 7 Clear passageway Var 4' -0" Min 6" Typ Surface of raised island Retaining curb T Ki nTF-c SECTION B - B 1. Sidewalk, ramp and passageway thickness, "T ", shall be 4" minimum. Curb ramp, See Note 10 2. Minimum width of passageway through raised islands shall be 4' -0", except as approved by city engineer for locations where right of way restrictions, natural barriers, or other existing conditions create an unreasonable hardship, the clear width of the passageway may be reduced to 3' -0 ". 3. For details of grooving used with Case CM curb ramp, see STD 232G, grooving detail. 4. For details of detectable warning surfaces, see STD 232G. 5. Where an island passage way length is less than 6' -0 ", the detectable warning surface shall extend the full width and full depth of the passage way length. Where an island passage way length is greater than or equal to 6' -0 ", but less than 8' -0 ", a detectable warning surface shall extend the full width and 2' -0" depth of the passage way length. Where an island passage way length is greater than or equal to 8' -0 ", a detectable warning surface shall extend the full width and 3' -0" depth of the passage way length. 6. For Case CM curb ramp (STD 232K), the edge of the detectable warning surface nearest the street shall be between 6" and 8" from the gutter flowline. 7. Transitions from ramps to walks, gutters or streets shall be flush and free of abrupt changes. 8. Maximum slopes of adjoining gutters, the road surface immediately adjacent to the curb ramp and continuous passage to the curb ramp shall not exceed 5 percent within 4' -0" of the top or bottom of the curb ramp. 9. Utility pull boxes, manholes, vaults and all other utility facilities within the boundaries of the curb ramp will be relocated or adjusted to grade by the owner prior to, or in conjunction with, curb ramp construction. 10. For additional curb ramp notes and details, see STD. -232A through STD. -232G. f necessary, construct retaining curb at edge of sidewalk A See Notes 15 & 16 6 Typ. " STD. -232A Grooving, see Note 3 0000°°°00 °000000°° 000000000 °0°000000 °000000°00 000000000 5' — 0 " Min . = °O °O °O °O °O °O °0 °0 °00 3 °0000000000° 2 Max I 8.3 3 00000000000 > Sidewalk N o 000°00000000 Max. 00000000000000 X O O000000000000000 v L 0000000000000000000000000 X 000000000 U 000000000000000000000000 a 000000000 00000000000000000000000 000000000 p 0000000000000000000000:2 00 O° O O° O O O O O O O O 0° °0 °0 °0 °0 °0 °0 °0 °0 °0 b� See 0000000000000000000 c 000000000 N 00 00000000000000 0 000000000 � Note 7 00000000000000 N 000000000 ,,,,,,,,,,,,,,,,,,000 000000000 Detectable warning surface, See Notes 4 CR See Note 7 and 6. Crosswalk See Note 7 A if provided CASE CM CURB RAMP Retaining curb Gutter if necessary flowline LT 2% Max See Note 6 SECTION A- A n i nT�c� 1. Sidewalk, ramp and passageway thickness, "T ", shall be 4" minimum. 2. Minimum width of passageway through raised islands shall be 4' -0", except as approved by city engineer for locations where right of way restrictions, natural barriers, or other existing conditions create an unreasonable hardship, the clear width of the passageway may be reduced to 3' -0 ". 3. For details of grooving used with Case CM curb ramp, see STD 232G, grooving detail. 4. For details of detectable warning surfaces, see STD 232G. 5. Where an island passage way length is less than 6' -0 ", the detectable warning surface shall extend the full width and full depth of the passage way length. Where an island passage way length is greater than or equal to 6' -0 ", but less than 8' -0 ", a detectable warning surface shall extend the full width and 2' -0" depth of the passage way length. Where an island passage way length is greater than or equal to 8' -0 ", a detectable warning surface shall extend the full width and 3' -0" depth of the passage way length. 6. For Case CM curb ramp (STD 232K), the edge of the detectable warning surface nearest the street shall be between 6" and 8" from the gutter flowline. 7. Transitions from ramps to walks, gutters or streets shall be flush and free of abrupt changes. 8. Maximum slopes of adjoining gutters, the road surface immediately adjacent to the curb ramp and continuous passage to the curb ramp shall not exceed 5 percent within 4' -0" of the top or bottom of the curb ramp. 9. Utility pull boxes, manholes, vaults and all other utility facilities within the boundaries of the curb ramp will be relocated or adjusted to grade by the owner prior to, or in conjunction with, curb ramp construction. 10. For additional curb ramp notes and details, see STD. -232A through STD. -232G. PROPERTY LINE OR EASEMENT 5 6" 1 d d 12" MAX. 4 a. TYPICAL SIDEWALK � 18" MAX. a a. 1' — 0" WITH RETAINING WALL NOTES: 1. IN FLATLAND AREAS, MAX SLOPE OF GROUND TO BE 5:1 OR FLATTER AS DIRECTED BY THE CITY ENGINEER. 2. RETAINING WALL TO BE INSTALLED AS PROPERTY LINE PER DIRECTION AND ONLY WITH OR EASEMENT APPROVAL OF CITY ENGINEER. 3. RETAINING WALL IN HILLSIDES TO BE DESIGNED TO MEET APPROPRIATE STRUCTURAL REQUIREMENTS AND AS APPROVED BY THE CITY ENGINEER. TYPICAL SIDEWALK a a a: 5 1 WITHOUT RETAINING WALL EXPANSI so 15' Ni nTP-q - El ER STRIP (AS REQ'D) CURB AND GUTTER 1. WEAKENED PLANE: 1/8" WIDE x 1" DEEP IN SIDEWALKS, 1/8" WIDE x 1 1/2" DEEP IN CURB AND GUTTER. 2. EXPANSION JOINTS MATERIAL TO BE 1/4" THICK PREMOLDED JOINT FILLER FULL THICKNESS OF CONCRETE. APROVED MECHANICAL JOINTS MAY BE USED IN WALKS IN LIEU OF EXPANSION JOINTS. 3. SCORE MARKS FOR SIDEWALKS 6' & MORE IN WIDTH: LONGITUDINAL SCORE MARK ALONG CENTER OF WALK. 4. EXPANSION JOINTS SHALL BE INSTALLED IN THE CURB & GUTTER AT ALL CURB RETURNS. 5. EXPANSION JOINTS SHALL BE PLACED IN THE SIDEWALK AT THE SAME LOCATION AS THOSE IN THE CURB & GUTTER WHEN THE SIDEWALK IS CURB ADJACENT, UNLESS OTHERWISE DIRECTED BY THE CITY ENGINEER. 6. SIDEWALK SHALL HAVE 4" BASE MATERIAL (CLASS II AGGREGATE BASE ROCK OR SAND), 4" OF P.C.C., AND HAVE A 2% SLOPE TOWARDS THE STREET. 7. SCORING PATTERN SHOULD MATCH ADJOINING SIDEWALKS. NAManual of Standards \2010 Streets & Roadway Stand ards \CAD \235 weak planes- 201 0.dwg Oct 28, 2010 - 4:26pm 18" (SEE NOTI 3' -6" MIN. E Loomm- A NTS SECTION A —A NTS 2" X 6" S4S NO. 2 D.F. OR BETTER (TYP.) 4" X 4" S4S POST, CONSTRUCTION HEART REDWOOD (TYP.). 5/8" GALVANIZED CARRIAGE BOLT, WASHER AND NUTS COUNTERSUNK MID ) . COMPACTED FILL SEE NOTE 2 14 N OTES : 1. PAINT ALL EXPOSED SURFACES WITH 1 COAT OF PRIMER AND 2 COATS OF GLOSS WHITE EXTERIOR ENAMEL AFTER CONSTRUCTION. 2. POSTS SHALL BE BACKFILLED AND COMPACTED WITH NATIVE SOIL. 3. ALL PORTIONS OF POSTS TO BE INSTALLED BELOW FINISHED GRADE SHALL BE TREATED WITH A WOOD PRESERVATIVE. 4. IF SIDEWALK IS CONTIGUOUS TO CURB, BARRICADE SHALL BE 18" BACK FROM FACE OF CURB. SIDEWALK PLANTER (SEE NOTE 4) P.C.C. 2% ............ rf7--.-I_i�� 4" SAND OR - CLASS II AB N OTES 1. JOINTS AND SCORING PER STD. -235. 2. ALL CONCRETE SHALL BE CLASS A P.C.C. 3. * 6" FOR DRIVEWAY AREA. 4. SIDEWALK WIDTH SHALL MATCH EXISTING (UNLESS OTHERWISE CONDITIONED) AND SHALL MEANDER OR WIDEN AT OBSTRUCTIONS TO PROVIDE CLEARANCES AS SHOWN IN CITY STD.- 231. 5. DESIGN SHALL CONFORM TO THESE REQUIREMENTS EXCEPT AS OTHERWISE APPROVED BY THE CITY ENGINEER. CLASS 1 BIKE PATH OR MULTIUSE TRAIL — 2' — (min.) GRADED \�j \�j \�j / X 2' yin.) ADED 2% Slope on Shoulder Typ. 6" CL 2 Agg. base @ 95% RC. plus '---Subgrade: 3% over 6" CL 1 Agg subbase @ 95% RC. optimum moisture or 12" CL 2 A .Base @ 95% R.0 conditioning & gg compaction @ 90% NOTES 1. Design of Bike Path or Multipurpose Path shall be per chapter 1000 of the Highway Design Manual. 2. The minimum paved width for a two —way bike path shall be 8 ft. The minimum paved width for a one —way bike path shall be 4.5 ft. A minimum 2 ft. graded area shall be provided adjacent to the pavement. A 3 ft. graded area is recommended to provide clearance from poles, trees, walls, fences, guardrails, or other lateral obstructions. 3. A minimum 2 ft. horizontal clearance to obstructions shall be provided adjacent to pavement. 4. The vertical clearance to obstructions across the clear width of the path shall be a minimum of 9 ft. 5. Asphalt paving shall be 1/2 )) Max. —Med. HMA @ 95% compacton 10' CROSSWALK (TYPICAL) 12" TYPICAL TRAFFIC SIGNAL L.G. STANDARD— IN LINE WITH CROSSWALK STRIPE (NP) STREET NAME SIGN F.C. I 2° I C. B. 5. � � 0 � I I � I i I I i I B.S.W_ R/W � TRAFFIC SIGNAL � CONTROLLER & 2 SERVICE CABINET �lkJ) (SEE NOTE 1) I I CURB RETURNL _ _ _ _ _ _ _ SEE STD. -857 FOR DATA: R =35' FIRE HYDRANT A= 90° (SEE NOTE 4) LOCATION C.6. I I 6" NOTES: 1. TRAFFIC SIGNAL CONTROLLER & SERVICE CABINET MAY HAVE ALTERNATE LOCATIONS IF APPROVED BY THE CITY ENGINEER. 2. THE MINIMUM CURB RETURN RADIUS FOR REGIONAL & INDUSTRIAL STREETS SHALL BE PER SECTION VII. INTERSECTIONS, SUBPARAGRAPH C., "CURB RETURNS." 3. FOR DELTA ANGLES GREATER THAN 900, CURB RETURN PLAN DETAILS SHALL BE APPROVED BY THE CITY ENGINEER. 4. DESIGN SHALL CONFORM TO THESE REQUIREMENTS EXCEPT AS OTHERWISE APPROVED BY THE CITY ENGINEER. CITY OF ROHNERT PARK, CURB RETURN PLAN DETAIL SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 240a 10' CROSSWALK (TYPICAL) L.G. STREET NAME F.C. — _ ? � SIGN O 48" MIN. I \ \ TRAFFIC SIGNAL - I STANDARD- IN LINE \ SEE STD. -857 FOR WITH CROSSWALK FIRE HYDRANT B.S.W. STRIPE (TYP) LOCATION R/W \ \ TRAFFIC SIGNAL \ CONTROLLER & SERVICE CABINET (SEE NOTE 1) I / CURB RETURN DATA: R =20' I A = 90° (SEE NOTE 4) 6" 12" TYPICAL 1. TRAFFIC SIGNAL CONTROLLER & SERVICE CABINET MAY HAVE ALTERNATE LOCATIONS IF APPROVED BY THE CITY ENGINEER. 2. THE MINIMUM CURB RETURN RADIUS FOR REGIONAL & INDUSTRIAL STREETS SHALL BE PER SECTION VII. INTERSECTIONS, SUBPARAGRAPH C., "CURB RETURNS." 3. FOR DELTA ANGLES GREATER THAN 90° , CURB RETURN PLAN DETAILS SHALL BE APPROVED BY THE CITY ENGINEER. 4. DESIGN SHALL CONFORM TO THESE REQUIREMENTS EXCEPT AS OTHERWISE APPROVED BY THE CITY ENGINEER. CITY OF ROHNERT PARKI CURB RETURN PLAN DETAIL 2 SCALE: NONE DATE: OCTOBER 2010 Approved: STD. - 240b 6» 2„ a R-1/2 16" a 8" zn a a 4" MIN. 7rc- �L CLASS 2 AGGREGATE BASE COMPACTED TO 95% RELATIVE DENSITY SEE STD 264 IF MEDIAN IS LANDSCAPED a , �"l O� > O 8„ A. C. O���O� a c BASE o O 00 ALTERNATE CONSTRUCTION MATCH BASE DEPTH 4" MIN Im1��1 DEPTH 4" MIN NOTES: 1. TYPE 6 TO BE USED UNLESS SPECIFICALLY STATED ON THE PLANS AND APPROVED BY THE CITY ENGINEER 2. SEE CITY STD. -235 FOR LOCATION OF WEAKENED PLANES AND EXPANSION JOINTS. 3. THESE DETAILS APPLY TO NEW CONSTRUCTION AND RECONSTRUCTION PROJECTS ONLY. MEDIAN CURB TO BE DETAILED ON PLANS WHERE INSTALLED ON EXISTING PAVEMENT. 4. ALL CONCRETE SHALL BE CLASS "A" P.C.C. CITY OF ROHNERT F 5. WHERE THE MEDIAN ISLAND IS TO BE PAVED, THE MEDIAN AND THE CURBS ARE TO BE STREET MEDIAN CURB POURED AS A UNIT (NO COLD JOINT). m � J � V) J O w Q Ow U) m w� �z w W Of o ��OO JLV UO zL(!J �O W � O° w w w � w ZO z g o o U � �0 Ld 0Cnm>- O- U) =Ld X m� Uw �pwpF-? ��w� m woo UW oF- �j O W � �z Q =D> � mU pw� Wm U D LLJ m~J� Ow U?\ Q �U UQ�� J °z� Q �m Z z w _ ^ O cn> 0 JQOWo J ^ Qm �WNJ Q ~ O UQ�LV F- 0 Lv J= ZLV W Y wU LLJ N =, z� ZUQ(n 3_ m U w w0- F- �w0w <ix JO J Q 0g _ Zw� UUm =Qwz JO! J �w m N oXCnm ww � ~m�Ixz =m Q c0 Nw www0 ° -mz V) —i _=0of � \mQ QzF °L�;ONDF-OgJzOQ V) LLJ� Ow O .. moo—�v >��ZQ�Q(nw� ~> r_ clf Z U) F Ox O m w�w��ch wX(/)of z Ln N LLJ z w = Qm0!m Qth wmwD U Of w F- 0 Oro �LV W x0c�� Of mOf F- w >O >F- ZU00 z Q�Qz DmD Oz =CECE Of w O Cr \pw � O �l�0- Q QUQU z0�00- 0Of U Q O z N X Q ^ 0_ O� • N ry LLJ 0O D �cl:� U U Iq U LL X z L ° O W Q Q F_ z a_ z U J O Of I -1 Q Q N L O > WW W z z Y Z LLw o QC O � � I I U W o U W i o W u� •' U �m z QU Ia X� � b� oW W� 1. W� _ N U LLJ cn 0_ N �J N �W a O QXZW _ X °z cnm rn ° m Q �O Wo 1' Q z Q~ Q N ^ U) \ � W � (n NW < ZF Q vU U) V) ^ Q °U :2 Q (n 000- U o W mm U) 00 06 U J U Q 000- 00 W ° m � `- W CITY OF ROHNERT PARK O U MULTI - RESIDENTIAL AND COMMERCIAL v ° W N CURB CUTS Q ,�, O m Q SCALE: NONE DATE: OCTOBER 2010 LL J Approved: STD.-250A w � of J w z z� Z z J O QWQQ� W O (nJ OQ �� �W �o WZ U LL- F- Q � J~ UZ w> F- M ~(n�'--� ch x=00 W Jw O z� w� Q W W z ~ W O Z ° w w ��m�0� WQw��zOf wX mLL- Fn Q U =~ Q �U >F— W J�w3 m Q Q W W w z UX W 0� QW � Q�(nW p � = =zw0 QW ZW w0F = m _D> � Q F- F- 0w N WO w F- LL- U m�J� z� zOw UZ\ Q(n U W N m U Q Q W Q Q W m z J W = w I mmWw0 JQF-w O ~��J F- 0-~Q M,-, �w N J� m Q � ^� zNMX> U ^ F03 zw(n U) LL- zw m Y wm UQ WO Z� UD WzUWQcn � U z m z LU JOQ-0 U m =Q wm z .� (n ��l O z X OF- a- g o�w ° Lwf =�_��° p�nliz owQ QJLL- Z M-i QZ � (n O �Woo =w 0 W w 00� Jch 00 nD z>-u) :2Ld U g � >- � Q �� .. U �U >� wcnD Q W> Q�Qz w CD U) x O m U 3ZLhOw�w�ch ct w Xw rz �z QmQf m Q W0 J]f llfWmW U ^ W > � ch m Q� ~ W a- Q F- Z000 Qch DmD Ozm �wwm = -��w O c� \O I O Mw QUQU ZOO 00 00- 0Of U Q I z N 4 L6 (6 r; 00 6 I L,.., I F- 0 z w I �' °w w o� U) cn �. • N Zw \ w O N • a O LI Q z w I U) O F— Q Y W b I z � JI � z J° I I U <" W W 5- cn ° C� Uo � I . 1. U Y° o F-: LL' Z I � JW la X Q I w "4 c, w� � I° a U) z � w N �' � cn m o� � Wo Q 48 Q 0 0 W z a cv can m�� I U .. D^ Q — U D cn cn co N J z UU U CD a: co m� CITY OF ROHNERT PARK Q:� w D RESIDENTIAL CURB CUTS Q O LL. N SCALE: NONE DATE: OCTOBER 2010 Y w w ° Approved: Q °— Q STD.-25013 m cn J SEE NOTE 1 W A � A � E. C. i PED. RAMP (TYP) d: a. ' - d• 2 2 2 '� . • • a .. I �Q l< <I I I B C GUTTER FLOW LINE COMMERCIAL DRIVEWAY NinTF-c- THE FLOWLINE SHALL BE RAISED: 1. TWO INCHES AT THE A/2 TO EXPEDITE DRAINAGE; OR 2. TO THE BOTTOM OF THE STREET SECTION, WHICHEVER IS GREATER. WALK � _ P TOP OF CURB SLOPE 1/4 PER FT. 1/2 RAD. 6" VARIABLE 6 . MIN. SLOPE 1 " PER FT. a ° / SECTION AT DRIVEWAY A.C. BATTER 1 " TO 12" EXISTING COMPACTED W FI LL "C" VARIABLE LEVEL LINE 8" CLASS A P.C.C. Ni nTF-c • SECTION A -A 1. DESIGN SHALL CONFORM TO THESE REQUIREMENTS EXCEPT AS OTHERWISE APPROVED BY THE CITY ENGINEER. 2. RADIUS TO BE A MINIMUM OF 10 FEET. 3. PEDESTRIAN RAMP NEEDED ACROSS DRIVEWAY AT SIDEWALK INTERSECTION WITH DRIVEWAY. 4. USE OF THIS STANDARD AS APPROVED BY THE CITY ENGINEER. 5. DRIVEWAYS SHALL NOT ENCROACH ON CURB RETURNS OR PROPERTY LINE EXTENSIONS. 6. CONCRETE SHALL BE 1-1/2 to MAX. AGGREGATE (6 SACK). 7. 1/8 )1 x 1-1/2" DEEP WEAKENED PLANE JOINTS TO BE PLACED ON BOTH SIDES OF DRIVEWAY. a DRIVEWAY CURB & GUTTER a a d TAPER CURB HT. & TRANSIITION GUTTER WITHIN 2' (TYP.) 6" CUR .d 6" CURB 0" CURB, , 0" CURB x ap a Q 0" CUR a a 5' SIDEWALK 0" CURB ° a zi ° a Q d Q 4 4 = W p d zi 4 4 6" CURB a a a Q Q p a 6" CURB as F- (If a � p a a FLOW LINE CURB FACE 4 a 4 4 ° Q 4 d d p d p Q 4 STD. 241 CURB & GUTTER LIP OF GUTTER COMMERCIAL DRIVEWAY THE FLOWLINE SHALL BE RAISED: 1. TWO INCHES AT THE A/2 TO EXPEDITE DRAINAGE; OR 2. TO THE BOTTOM OF THE STREET SECTION, WHICHEVER IS GREATER. BATTER 1 to TO 12" EXISTING COMPACTED FI LL 1lLwW`mffmmr� 1. CURB RETURN RADII TO BE A MINIMUM OF 10 FEET. 2. USE OF THIS STANDARD AS APPROVED BY THE CITY ENGINEER. 3. DRIVEWAYS SHALL NOT ENCROACH ON CURB RETURNS OR PROPERTY LINE EXTENSIONS. 4. CONCRETE SHALL BE 1-1/2 1$ MAX. AGGREGATE (6 SACK). 5. 1/8 11 x 1-1/2" DEEP WEAKENED PLANE JOINTS TO BE PLACED ON BOTH SIDES OF DRIVEWAY. _ P TOP OF CURB 1/2" RAD. I r 4 ++ ~ SECTION AT DRIVEWAY CE FOR GROVE DETAIL N.T.S. REFER TO CITY STD. 3.1 VARIES VARIES DEPRESSED DRIVEWAY APPROACH M X 1 � 1M� 0.5' TC -� BACK OF WALK RW ° �- U v -� PROFILE AT CURB FACE �O �O \G 127 MAX. DRIVEWAY N.T.S. 4' OtK �O'O 0 0 0� SIDEWALK BEYOND ,0O 2% -� 4» R =1.5" DEPRESSED DRIVEWAY APPROACH SECTION A —A N.T.S. STREET STREET SLOPE X 5-6% 8' 4 -5% 6' 3 -4% 5' 2 -3% 4' 0.5 -2% 1 3' X= MINIMUM DISTANCE ' ON HIGH SIDE OF 2' 3' 16' DRIVEWAY /� X DRIVEWAY No MIN LOW SIDE HIGH SIDE BACK OF WALK ill ill Y lof RAMP 2%° � RAMP lof L Q 12:1 MAX I =1 I ~I 12:1 MAX t, I =1 I ~I o F/C SLOPE &GUTTER LIP A) STREET FOR GROVE DETAIL N.T.S. REFER TO CITY STD. 3.1 VARIES VARIES DEPRESSED DRIVEWAY APPROACH M X 1 � 1M� 0.5' TC -� BACK OF WALK RW ° �- U v -� PROFILE AT CURB FACE �O �O \G 127 MAX. DRIVEWAY N.T.S. 4' OtK �O'O 0 0 0� SIDEWALK BEYOND ,0O 2% -� 4» R =1.5" DEPRESSED DRIVEWAY APPROACH SECTION A —A N.T.S. STREET ° 6" P.C.C. ° ° NE 3" ASPHALT CONCRETE : 6„ CLASS 2 AG G . BASE SECTION A -A SAWCUT AS AND IF DIRECTED =ER F.C. L.G. :: NOTE: DRIVEWAY CONFORM 1. DESIGN SHALL CONFORM TO THESE REQUIREMENTS EXCEPT AS OTHERWISE APPROVED BY THE CITY ENGINEER. AREA Tim NOTES: 1. FOR TREE TYPE, REFER TO THE STREET TREE LIST IN VOLUME 1. 2. ROOT CONTROL DEVICES SHALL BE USED FOR ALL TREES PLANTED IN SIDEWALK CUTOUTS, PLANTER STRIPS, & BEHIND SIDEWALKS BUT WITHIN THE PUBLIC RIGHT -OF -WAY. FOR ROOT BARRIER TYPE, REFER TO PUBLIC WORKS DEPARTMENT. 3. TREES SHALL BE PLANTED 10' MINIMUM FROM WATER SERVICES OR SEWER LATERALS WIDTHS (W): PER STREET TREE LIST VOL.1 NOTES: ROOT BARRIER 1. FOR TREE TYPE, REFER TO THE STREET TREE LIST IN VO L.1. 2. ROOT CONTROL DEVICES SHALL BE USED FOR ALL TREES PLANTED IN SIDEWALK CUTOUTS, PLANTER STRIPS, & BEHIND SIDEWALKS BUT WITHIN THE PUBLIC RIGHT -OF -WAY. FOR ROOT BARRIER TYPE, REFER TO PUBLIC WORKS DEPARTMENT. 3. TREES SHALL BE PLANTED 10' MINIMUM FROM WATER SERVICES OR SEWER LATERALS 4 4 p ° a 4 a 4 a a p Q p a 4 a ° W a• W W r 4 4 p 4 a 4 a 4 a ° a 4 �F QY7 NOTE: W shall be at least as large as the dimension listed in the Tree List Vol.1 with minimum of 4'x4' SIDEWALK 4 TREE WELL 0 NOTES: 1. For tree type, refer to the Street Tree List in Vol.1. 2. Root control devices shall be used for all trees planted in sidewalk cutouts, planter strips, & behind sidewalks but within the public right —of —way. for root barrier type, refer to public works department. a° 9t p 4 p L ° p ° d p • a °a a pa a Y ° J Q w 0 M d p a 4Q C p 2> 'T —T i 4�� Z-1"" I/ e�� Ll NOTE: 1. FOR TREE TYPE, REFER TO THE STREET TREE LIST IN VOLUME 1. 1 LANDSCAPE STRIP CURB a a A.C. SURFACING a a CLSM a a a a a a AGGREGATE BASE 6" MIN. VISQUEEN LINED TRENCH 4„ (10 MIL. MIN.) MIN. MEDIAN /SIDEWALK CURB a a A.C. SURFACING zn a a o a CLSM a a a a a AGGREGATE BASE 6" MIN. VISQUEEN LINED TRENCH „ (10 MIL. MIN.) 4 MIN. Refer to Section VII.E.3. of Design Standards Moisture barrier shall be placed at edge of all roadways and medians Locate moisture barriers at the outside edge of contiguous pavement (eg. if sidewalk is adjacent to road, place moisture barrier at back of sidewalks, if there is a landscape strip place moisture barrier at back of curb.) CITY OF ROHNERT PARK MOISTURE BARRIER SCALE: NONE DATE: MARCH 2011 Approved: STD. - 264 City of Rohnert Park Manual of Standards, Details and Specifiications (Volumes 1, 2 and 3) Volume 3 Construction Specifications Construction Specifications Volume 3 for Public Improvements Revised October 2010 a City of Rohnert Park Manual of Standards, Details and Specifications Volume 1 Design Standards Volume 2 Detail Drawings 1. Water 2. Sewer 3. Storm Drain 4. Streets and Roadway 5. Traffic 6. Street Lighting 7. Parks and Landscaping 8. Bicycle Parlcing Volume 3 Construction Specifications TABLE OF CONTENTS Volume 3 Construction Specifications PartI Definitions ........................................................................................ ..............................1 Part II Modifications and Revisions to the Standard Specifications .......... .............................21 Section 6 — Control of Materials ........................................................................ ..............................3 Section10 — Dust Control .................................................................................. ..............................4 Section12 — Traffic Control .............................................................................. ..............................5 Section 12 -5 — Material Recycling .................................................................. ..............................7 Section 15 — Existing Highway Facilities ........................................................ ..............................8 Section 16 — Clearing and Grubbing ............................................................. ............................... 9 Section19 — Earthwork ................................................................................... ...........................4 -210 Section 20 -4 — Highway Roadway Planting ................................................. .............................14 Section21 — Notification ............................................................................ ............................... 16 Section 24 — Lime Treatment ...................................................................... ............................... 17 Section 25 — Aggregate Subbase ...................................... ............................... ...........................2219 Section26 — Aggregate Base ...................................................................... ............................... 20 Section 37 — Bituminous Seals ....................................................................... ...........................:�21 Section 39 — Asphalt Concrete .................................................................... ............................... 30 Section 39A — Asphalt Concrete Trench Paving ........................................ ............................... 3638 Section 40 — Portland Cement Concrete Pavement .................................... ............................... 3739 Section 51 — Concrete Structures ................................................................ ............................... 40 Section56 — Signs ....................................................................................... ............................... 4042 Section 63 — Cast -in -Place Concrete Pipe .................................................. ............................... 4143 Section 64 — Asbestos - Cement Pipe-(DELETED) ...................................... ............................... 45 Section64 — Plastic Pipe ............................................................................. ............................... 4646 Section 65 — Reinforced Concrete Pipe ............................................................ .............................48 Section 66 — Corrugated Metal Pipe ................................ ............................... ...........................5350 Section71 — Sewers .................................................................................... ............................... 51 Section 72 — Slope Protection ..................................................................... ............................... 63 Section 73 — Concrete Curbs and Sidewalks .............................................. ............................... 6764 Section 76 — Concrete Cylinder Pipe .......................................................... ............................... 66 Section77 — Pipe Casing ............................................................................ ............................... 72 Section 78 — Reinforced Plastic Mortar Pressure Pipe ............................... ............................... 73 Section 79 — Video Inspection of Storm Drains ......................................... ............................... 8175 Section 80 — Chain Link Fence Construction ............................................. ............................... 78 Construction Specifications i Volume 3 for Public Improvements Revised October 2010 a Section 80 -5 — Redwood Fence .................................................................. ............................... M80 Section81 — Monuments ............................................................................ ............................... 8981 Section 83 — Railing and Barriers ............................................................... ............................... 9082 Section 84 — Traffic Stripes and Pavement Markings ................................ ............................... 83 Section 85 — Pavement Markers ................................................................. ............................... 9284 Section 86 — Traffic Signal Detector Loops and Video Detection System . ............................... 9385 Section 90 — Portland Cement Concrete ..................................................... ............................... 9587 Section 98 — Handicap Ramp Construction ................................................ ............................... 88 Section 99 — Water Main Construction ....................................................... ............................... 89 ......................................................... ............................... S Section 100 -2 — Adjust Valve Covers, Cleanouts and Monuments to Grade ........................ 102 Section 100 -7 — Sacked Concrete Riprap ............................................... ............................... 103 Section 100 -8 — Reinforced Concrete Headwall ..................................... ............................... 449104 Section 100 -10 — Remove and Reset Mailbox ........................................ ............................... 421105 Construction Specifications ii Volume 3 for Public Improvements Revised October 2010 a Construction Specifications City of Rohnert Park Part I Definitions Public improvements within the City of Rohnert Park shall be constructed in accordance with the Standard Specifications of the State of California, Department of Transportation, Division of Highways (Caltrans), latest edition, which specifications are hereinafter referred to as the Standard Specifications, and in accordance with the following modifications and revisions herein stated in Volume 3 of the City of Rohnert Park Manual of Standards and Specifications. Whenever in the Standard Specifications the terms, State of California, Department of Transportation, Director, Division of Highways, Engineer, or Laboratory are used, the following terms shall be understood and interpreted to mean and refer to such substituted terms as follows: For State of California substitute City of Rohnert Park. For Department substitute the Public Works Department of the City of Rohnert Park. For Director substitute the City Engineer of the City of Rohnert Park. For Division of Highways substitute the Engineering Division of the City of Rohnert Park. For Engineer substitute the City Engineer, acting either directly or through properly authorized agents, such agents acting within the scope of the particular duties entrusted to them. For Laboratory substitute Private Laboratory as authorized by the City to test materials and work involved in the contract. -- - - - -- - - - - - - - - iiiiii- 01 - - Specifications pertaining to the administration of the City contracts will be contained in the special provisions for the contract. References to contract administration, measurement, and payment shall not apply to non -City contracts. Abbreviations: "City Std." means City of Rohnert Park Standard Detail "City Spec." means City of Rohnert Park Construction Specification "Standard Specifications" means State of California Department of Transportation Standard Specifcations , latest editionsate Tul T 2nn2 Construction Specifications 1 Volume 3 for Public Improvements Revised October 2010 Part II Modifications to Standard Specifications Part II includes modifications and revisions to the Standard Specifications. Only those subsections which are modified or revised will be noted herein. The Standard Specifications number sequence will be followed. Subsections to be modified will be noted as "(Subsection number) (Title)" followed by the modifications or additional requirements. In case of conflict between the Standard Specifications and the modification, the modification shall apply. Subsections to be deleted without modification will be noted as "(Subsection number) (Title) (Deleted) ". Subsections which are completely revised will be noted as "(Subsection number) (Title) (The following shall apply in lieu of Section ). Construction Specifications 2 Volume 3 for Public Improvements Revised October 2010 SECTION 6 — CONTROL OF MATERIALS All materials, parts, and equipment furnished by the Contractor in the Work shall be new, high grade, and free from defects. Quality of work shall be in accordance with the generally accepted standards. Material and work quality shall be subject to the Engineer's approval. Materials and work quality not conforming to the requirements of the Specifications shall be considered defective and will be subject to rejection. Defective work or material, whether in place or not, shall be removed immediately from the site by the Contractor, at its expense, when so directed by the Engineer. notice, the Engineer may cause such work or materials to be replaced. The replacement expense moving average requirements shall apply to the individual test results. Construction Specifications 3 Volume 3 for Public Improvements Revised October 2010 SECTION 10 — DUST CONTROL 10 -1.01 Description Attention is directed to the provisions in Section 10, "Dust Control ", of the Standard Specifications. 10 -1.02A Dust Miti!ation Measures 1. All dust - producing work and unpaved construction sites shall require at a minimum watering in the late morning and at the end of the workday; the frequency of watering shall be increased if wind speeds exceed 15 mph. Construction Specifications 4 Volume 3 for Public Improvements Revised October 2010 SECTION 12 — TRAFFIC CONTROL 12 -1.01 Description Construction area traffic control devices shall be installed and maintained in accordance with the applicable sections as specified herein, the Standard Specifications, Part VI of the City Traffic Standards, the current edition of the Manual of Traffic Controls published by Caltrans, and as directed by the Engineer. 12 -1.02 Traffic Control Plan Prior to commencing construction which will affect existing traffic, the Contractor shall submit for review by the Engineer, a Traffic Control Plan on an 11 " x 17" sheet of paper which contains only information specifically related to work zone traffic control. If the Contractor proposes to use Manual of Traffic Controls Published by Caltrans in lieu of a traffic control plan, in specific work operations, he /she shall submit in writing for consideration which Standard Plan will be used for each work operation. A Traffic Control Plan or proposal shall be submitted for review at least two weeks prior to implementation. The Traffic Control Plan shall contain a title block which contains the Contractor's name, address, phone number, project superintendent's name, contract name, dates and hours traffic control will be in effect, and a space for review acknowledgment. The content of the Traffic Control Plan shall include, but is not limited to, the following: A. Show location and limits of the work zone. B. Give dimensions of lanes affected by traffic control that will be open to traffic. C. Indicate signing, cone placement, and other methods of delineation and reference to appropriate City or Caltrans standard. D. Dimension location of signs and cone tapers. E. Identify side streets and driveways affected by construction and show how they will be handled. F. Show how pedestrian traffic will be handled through the construction site. G. Demonstrate how two -way traffic will be maintained. No work except for installation of project identification signs will be allowed to commence prior to approval of the Work Zone Traffic Control Plan. Construction Specifications 5 Volume 3 for Public Improvements Revised October 2010 12 -1.03 Traffic Control Attention is directed to Section 7 -1.08, "Public Convenience" and to Section 5 -1.05, "Order of Work" of the Standard Specifications. Exact locations of Project Identification signs and Advance Notice signs (Section 7 -1.08 "Public Convenience ") shall be determined in the field by the Engineer. Lane closures will be permitted between the hours of 8:30 a.m. and 4:00 p.m. only. Only one lane at a time may be closed and no lanes shall be closed at any other hours unless specifically approved by the Engineer. The Contractor shall maintain vehicle access to homes and other properties at all times while work is in progress. The Contractor shall keep the City of Rohnert Park Police and Fire Department informed regarding the closure of any traveled way. At a minimum, the Contractor shall call the Police Department at 584-2600 daily to report any traveled way closure. This means immediately upon closure for that day and again immediately after removal of the closure. For closures over multiple days, the daily notification still applies. If the Contractor has been given an approved Traffic Control Plan that includes road closures, he /she will be required to maintain vehicular access to homes and other properties where work is in progress within the closure area. Seventy -two (72) hours prior to construction, the Contractor shall place a notice on each front door, and attempt to notify each owner or tenant verbally that work will be underway within his block between stated hours, and request that cars be parked out of the roadway by 8:00 a.m. Service of notice shall not bar use of local cars within the block. Barricades and flaggers shall be positioned to allow safe turns at intersections. The Contractor shall maintain traffic control as necessary and as directed by the Engineer. Flaggers, barricades, signing, etc., shall remain in place for protection of City personnel until such time as all temporary lane delineation is complete. Construction Specifications 6 Volume 3 for Public Improvements Revised October 2010 Construction Specifications 7 Volume 3 for Public Improvements Revised October 2010 > > > Construction Specifications 7 Volume 3 for Public Improvements Revised October 2010 SECTION 12 -5 — MATERIAL RECYCLING 12 -5.01 Description The Contractor shall dispose of all portland cement concrete and asphalt concrete, generated from removal or demolition activities on the project, at a recycler for these materials. The Contractor shall provide receipts verifying delivery and approximate quantity (in tons) of the material delivered to a material recycler. All other excess materials from the project shall become the property of the Contractor and shall be disposed of by him, at his expense. fl e e . Construction Specifications 8 Volume 3 for Public Improvements Revised October 2010 SECTION 15 — EXISTING HIGHWAY FACILITIES 15 -3 Removing Concrete 15 -3.02 Removal Methods Concrete removal shall conform to applicable provisions of Section 15 -3 of the Standard Specifications and as specified herein. All concrete to be removed shall be disposed of by the Contractor away from the site of the work. Burying of broken concrete within the limits of the project will not be allowed. All concrete which is to be removed from sidewalk, curb, gutter, and driveway areas shall be removed to the nearest score mark or construction joint as directed by the Engineer. Construction Specifications 9 Volume 3 for Public Improvements Revised October 2010 SECTION 16 — CLEARING AND GRUBBING 16 -1.01 Description Clearing and grubbing shall conform to the applicable provisions of Section 16 of the Standard Specifications, with the following modifications and additional requirements. Clearing, grubbing, and access shall be confined to the limits shown on the Plans and shall not exceed the minimum necessary to complete operations. The Contractor shall not remove any trees, brush, shrubs, or other natural objects outside the limits of construction as shown on the Plans, unless directed by the Engineer. Any trees, brush, shrubs, or other natural objects not ordered removed by the Engineer which have been removed, altered, or damaged shall be replaced in kind by the Contractor before completion of the project. All unsuitable material shall be disposed of away from the site by the Contractor. The Contractor shall make all necessary arrangements for disposal of material. 16 -1.02 Preservation of Property All existing street designation and traffic control signs and posts within the foram ntio ex limits of work shall be carefully removed, cleaned of excess earth and delivered to the City Corporation Yard at ' Trebi �600 Enterprise Drive except those required for traffic control as determined by the Engineer. 16 -1.03 Construction The area to be cleared and grubbed shall be the area within the right -of -way shown on the Plans, unless otherwise specified in the special provisions. All stumps, large roots and other objectionable material shall be removed to a depth of 3 feet below finished grade in the area of construction. The resulting spaces shall be backflled with material suitable for the planned use. Such suitable material shall be placed and compacted in layers as specified in Section 19 -6 "Embankment Construction" of the Standard Specifications. 16 -1.04 Removal and Disposal of Materials Combustible debris shall be disposed of away from the site of the work. Burning within the limits of the project will not be allowed. Clearing and grubbing will be paid for at the contract lump sum price for clearing and grubbing Construction Specifications 10 Volume 3 for Public Improvements Revised October 2010 ndditionnl nllownnno wiII4o w►ndo 4horoforo Construction Specifications 11 Volume 3 for Public Improvements Revised October 2010 SECTION 19 — EARTHWORK 19 -1.01 Description Unsuitable material may be removed and replaced, or may be stabilized in accordance with the provisions of Section 19 -2.02, "Unsuitable Material." 19 -1.03 Grade Tolerance Immediately prior to placing subsequent layers of material thereon, the grading plane shall conform to one of the following: A. When aggregate subbase or aggregate base is to be placed on the grading plane, the grading plane shall not vary more than 0.05' above or 0.1' below the grade established by the Engineer. B. When asphalt concrete base is to be placed on the grading plane, the grading plane shall not vary more than 0.05' above or below the grade established by the Engineer. 19 -2 Roadway Excavation 19 -2.02 Subirade Stabilization Unsuitable material shall be stabilized per Section 19 -2.02 of the Standard Specifications with the following additions: In the event that the subgrade material is unstable and cannot be made stable by drying the top six inches as determined by the Engineer, _ ' then the Contractor shall excavate an additional six inches, install soil stabilization fabric and install six inches of Class 4 aggregate sub -base. Prior to placement of soil stabilization fabric, the Contractor shall remove all loose dirt as left from excavation operations. Soil stabilization fabric shall be installed per manufacturer's recommendations and shall meet or exceed the following specifications: Grab Tensile Strength 290 lb. Mullin Burst Strength 500 psi Trapezoid Tear Strength 120 lb. Modulus (Load at 10% Elongation) 1201b. Equivalent Opening Size 40 -70 Sieve Water Permeability Coefficient(K) .003 cm/sec. Soil stabilization fabric shall be Miraf 600 -X, Supac 6WS, Fibretex TEN -5, or equal. Construction Specifications 12 Volume 3 for Public Improvements Revised October 2010 Aggregate sub -base shall be Class 4 with a minimum sand equivalent value of 21, a minimum R- value of 50 and shall conform to the following gradings: Sieve Size Percent Passing 2" 100 1 -1 1/211 90 -100 3/4" 50 -85 #4 25 -45 #200 2 -11 The material contained on the #4 screen shall consist of 100% crushed particles. Aggregate sub -base shall be end - dumped on the soil stabilization fabric without disrupting fabric or basement soil as directed by the Engineer. Rolling shall commence immediately after spreading of the damp material and before the material has dried sufficiently to allow separation between the fine and coarse particles. Compactor shall be a non - vibratory type and compaction shall be to 92% R.C. 19 -2.02 Unsuitable Material (The following shall apply in lieu of Section 19 -2.02) Material below the natural ground surface in embankment areas, and basement material below the grading plane in excavation areas, that is determined by the Engineer to be unsuitable for the planned use, shall be excavated and disposed of or stabilized as directed or approved by the Engineer. When unsuitable material is removed and disposed of, the resulting space shall be filled with material suitable for the planned use. Such suitable material shall be placed and compacted in layers as hereinafter specified for constructing embankments. Stabilization of unsuitable material shall comply with the following provisions: A. Unsuitable material may be processed in place, may be excavated and placed on the grade or other locations suitable for further processing, or may be partially excavated and partially processed in place. 19 -3.06 Structure Backfill Specifications for pipe bedding, trench backf ll and surfacing shall be as shown on City Std. 215, "Standard Trench Detail." Except for structural backfll placed at specific locations described and enumerated in Section 19 -3.06 of the Standard Specification, structural backfll material specifications and compaction requirements shall be as follows: Structure backfll shall have a Sand Equivalent value of not less than 30 and shall conform to the following gradation: Construction Specifications for Public Improvements 14 Volume 3 Revised October 2010 cc » , 19 -3.06 Structure Backfill Specifications for pipe bedding, trench backf ll and surfacing shall be as shown on City Std. 215, "Standard Trench Detail." Except for structural backfll placed at specific locations described and enumerated in Section 19 -3.06 of the Standard Specification, structural backfll material specifications and compaction requirements shall be as follows: Structure backfll shall have a Sand Equivalent value of not less than 30 and shall conform to the following gradation: Construction Specifications for Public Improvements 14 Volume 3 Revised October 2010 - - - - - - - - - - - - - 19 -3.06 Structure Backfill Specifications for pipe bedding, trench backf ll and surfacing shall be as shown on City Std. 215, "Standard Trench Detail." Except for structural backfll placed at specific locations described and enumerated in Section 19 -3.06 of the Standard Specification, structural backfll material specifications and compaction requirements shall be as follows: Structure backfll shall have a Sand Equivalent value of not less than 30 and shall conform to the following gradation: Construction Specifications for Public Improvements 14 Volume 3 Revised October 2010 Sieve Sizes Percentage Passing 3" 100 No. 4 40 -100 Structural backflll shall be compacted to not less than 90 percent relative compaction, except that when placed under any roadbed, relative compaction shall be not less than 95 percent within 3 feet of finished grade. 19 -4 Ditch Excavation Ditch excavation shall conform to the applicable provisions of Section 19 -4 of the Standard Specifications. 19 -4.01 Description Ditches shall be constructed in conformance with the details and at the locations as shown on the Plans, as directed by the Engineer, and as specified herein. 19 -5.03 Relative Compaction (95 percent — California Test 216 and 23 1) (The following shall apply in lieu of Section 19 -5.03) Relative compaction of not less than 95 percent shall be obtained for a minimum depth of 0.75 - foot below the grading plane for the full width of the planned structural section, whether in excavation or embankment. Any area of the subgrade determined by the Engineer to be unstable, as evidenced by excessive deflection under the movement of equipment, shall be brought to satisfactory stability by additional rolling, reworking, removal, and replacement of unsuitable material, or stabilization with lime, as directed by the Engineer. Lime treated materials shall be compacted to not less than 95 percent relative compaction in accordance with the provisions of Section 24, except when lime is used to stabilize unsuitable material as specified in Section 19 -2.02. Construction Specifications 15 Volume 3 for Public Improvements Revised October 2010 b n, 19 -5.03 Relative Compaction (95 percent — California Test 216 and 23 1) (The following shall apply in lieu of Section 19 -5.03) Relative compaction of not less than 95 percent shall be obtained for a minimum depth of 0.75 - foot below the grading plane for the full width of the planned structural section, whether in excavation or embankment. Any area of the subgrade determined by the Engineer to be unstable, as evidenced by excessive deflection under the movement of equipment, shall be brought to satisfactory stability by additional rolling, reworking, removal, and replacement of unsuitable material, or stabilization with lime, as directed by the Engineer. Lime treated materials shall be compacted to not less than 95 percent relative compaction in accordance with the provisions of Section 24, except when lime is used to stabilize unsuitable material as specified in Section 19 -2.02. Construction Specifications 15 Volume 3 for Public Improvements Revised October 2010 Relative compaction of not less than 95 percent shall be obtained for embankment under bridge and retaining wall footings without pile foundations within the limits established by incline planes sloping 1.5:1 out and down from lines one foot outside the bottom edges of the footing. 19 -5.04 Relative Compaction (90 percent — California Test 216 and 23 1) (The following shall apply in lieu of Section 19 -5.04) Relative compaction of not less than 90 percent shall be obtained in all materials in embankment except as specified herein to be 95 percent. Material placed in accordance with the provisions of Section 19 -2.02, "Unsuitable Materials," shall be compacted to not less than 90 percent relative compaction. 19 -7.02 Imported Borrow Imported borrow shall be free of any regulated hazardous materials. Construction Specifications 16 Volume 3 for Public Improvements Revised October 2010 SECTION 20 -4 — HIGHWAY ROADWAY PLANTING 20 -4.05 Planting Trees shall have a minimum height of twelve feet including root ball, and a minimum container size of fifteen gallons, with a caliper of 1" at 12" above the top of the root ball. Conditions of the plants shall be symmetrical, typical for variety and species, sound, healthy, vigorous, free from plant disease, insect pests or their eggs, and shall have healthy, normal root systems, well filling their containers, but not to the point of being root bound. Plants shall not be pruned or topped prior to delivery. Each tree shall be tagged to indicate genus and species. All plant material shall be subject of the inspection and approval of the City. The City has the right to reject any item offered. a. 48 -hour notification shall be given prior to any inspection. b. Upon initial notification, the Contractor shall indicate the number of sequences or planting phases necessary to complete the entire project. C. 24 -hour notice shall be given the City prior to starting any additional phase. d. At the time of final inspection, the City may select at random one tree from each planting phase, to be removed and inspected for compliance to planting specie cation. Parkway Tree Planting Operations: All pits shall be dug with bottoms level, the width equal to two times the diameter of the root ball, and the bottom 4-142-timexsr4 inches less than the depth of the root ball. The City upon notification shall inspect pits prior to planting of trees. Pits shall be backf lied with a thoroughly mixed "prepared soll"-to-the-bottoni-of4he-mot-ba4l. When planting tablets are required, they shall be placed prior to placing the tree in the pit. Five (21 gram) planting tablets shall be evenly spaced around perimeter of pit on top of prepared soil. "Prepared soil" mix for backfll of the pits for 15- gallon trees shall consist of excavated soils and the following: a. 50% by volume of nitrolized soil amendment. b. 50% by volume native soil. Note: (1) Nitrolized soil amendment shall be a composted wood byproduct combined with one pound of actual nitrogen per cubic yard of shavings. (2) Planting tablets shall be a commercial fertilizer in tablet form yielding 20% nitrogen, 10% phosphorus and 5% potash. The tablet shall be compressed and yield a slow release of nutrient over a 12 -month period. Set plants in center of pit, in vertical position, so that crown of ball will be level with finish grade after allowing for watering and settling--m:[ a �'� 111 '� °�r *'�° s ° r °;-rs'�;r *� ��;�'� �-r�a° -that 4t Prepare a depressed earth water basin capable of holding 10 gallons of water. Water shall be applied in that quantity at time of planting. Each tree must be properly supported by two Lodgepole Pine stakes. Stakes shall be a minimum of 2" x 2" and not less than eight feet in length. Stake all trees at time of planting by placing stake in prepared hole and driving stake a minimum of 30 inches into soil. Stakes shall be placed perpendicular to direction of prevailing winds. All trees shall be secured to stakes as detailed (or approved equal). Six -penny scaffold nails shall be used to secure the ties to the stakes — two per side. Gi a.ra.ntoes, Fifteen - gallon trees shall be guaranteed as to growth and health for a period of one year after final acceptance by the City. Trees that fail to grow or are injured or damaged during planting operations, shall be replaced within 30 days ° min* °rarc° r °rioa. Replacement material shall be guaranteed as specified as original guaranteed material. Trees not installed according to the requirements will be rejected by the City. Construction Specifications 18 Volume 3 for Public Improvements Revised October 2010 SECTION 21— NOTIFICATION 21 -1.01 The Contractor shall notify the Project Engineer or Project Inspector of any work to be performed on any given work day either on the afternoon of the prior working day or before 8:30 a.m. on the given working day. Any work completed for which the Project Engineer or Project Inspector has not received prior notification of its scheduling MAY NOT BE ACCEPTED-FOR p A VME�'T Construction Specifications 19 Volume 3 for Public Improvements Revised October 2010 SECTION 24 — LIME TREATMENT 24 -1.01 Description (The following shall apply in lieu of Section 24 -1.01) This work consists of stabilizing basement soil, mixing in place material, lime and water, and spreading and compacting the mixture to the lines, grades, and dimensions shown on the Plans and as specified herein. 24- 1.01 -A Where designated by the Engineer, basement soil below the planned lime treated subgrade shall be stabilized in the following manner: The material shall be excavated to the lines and grades specified by the Engineer and spread in a uniform layer over another portion of the grade. Dry lime in the amount specified by the Engineer shall be spread and mixed into the material as provided in Section 24 -1.06, "Mixing ". The material shall then be used to backfll the original excavation in 6" compacted layers. Each layer below a plane 12" below the grading plane shall be compacted to not less than 90 percent relative compaction. Each successive 6" layer up to the bottom of the planned lime treated subgrade shall be compacted to not less than 92 percent relative compaction. 24 -1.02 Materials Lime to be used shall be granular guicklime and shall be added to the existing material at the .approximate rate of four percent by weight of the dry material, the exact percentage to be determined by the Engineer, based oneotechnical tests provided by the contractor. Lime treatment must be a�roved by the Engineer in writing, and when accompanied by an adequate safety program to be proposed by the Contractor. Granular quicklime shall conform�g to the specifications of ASTM Designation CS l��rk�ett Hydrated lime shall be used only when permitted by the Engineer in writing. When sampled by the Engineer at the point of delivery, the sample of quicklime shall contain not less than 90 percent Calcium Oxide, CaO, as determined by ASTM: C 25 -67. G ranular quicklime_�initial mixing shall continue until the quicklime is uniformly distributed throughout the material. Water shall be added as required to proved sufficient moisture for hydration. The mixture shall be cured for not less than 16 hours prior to final mixing. Construction Specifications 20 Volume 3 for Public Improvements Revised October 2010 Lime to be used shall be granular quicklime and shall conform to Section 24 -1.02 of the City The Contractor shall provide a grade checker to insure mixing to the full depth as specified. Water shall be added during the final mixing operations until the water content of the mixture is approximately two percent above the test optimum moisture content. 24 -1.06 Mixinfy Mixing shall be in accordance with Section 24 -1.06 of the Standard Specification. 24 -1.075 Spreading and Compacting Lime treated material shall be a minimum of 126 inches deep except where reciuired elsewhere to be reater and finished to the lines and grades as shown on the Plans. Lime treated material shall be compacted to not less than 95 percent, as determined by Test Method No. California 216 and 231. The sample of lime treated soil used for determining the maximum wet density shall be obtained from the test site at the time of testing. The surface of the lime treated material shall not vary more than 0.05 -foot above or below the grade established by the Engineer 24-1.0609 Curin Curing of lime treated material shall be in accordance with Section 24 -1.09 of the Standard Specifications. The Contractor may, at his option, omit the curing seal if the first lift of A.C. Base is placed within twenty -four (24) hours after the final compaction of the lime treated material. Construction Specifications 21 Volume 3 for Public Improvements Revised October 2010 nddftionnl nfl wnnno wffl bo w►���� �������r�n� n� �zrnr�no �z»�� �a w►n�o ��- ►oro��ro Construction Specifications 21 Volume 3 for Public Improvements Revised October 2010 SECTION 25 — AGGREGATE SUBBASE 25 -1.01 Amymate Subbase Aggregate subbase shall be Class 4 conforming to and placed in accordance with the requirements of Section 25 of the Standard Specifications, with the following modifications and additional requirements. Aggregate subbase shall be Class 4 with a minimum sand equivalent value of 21, a minimum R- value of 50 and shall conform to the following gradation: Sieve Size Percent Passing 3" 100 1 -1/2" 90 -100 3/4" 50 -90 #4 25 -55 #200 2 -11 The material contained on the #4 screen shall consist of 100% crushed particles. Rolling shall commence immediately after spreading of the damp material and before the material has dried sufficiently to allow separation between the fine and coarse particles. 25 -1.03 Grade Tolerance The subgrade to receive aggregate subbase, immediately prior to spreading, shall not vary more than 0.05 -foot above or 0.1 -foot below the grade established by the Engineer. 25 -1.05 Compacting The surface of the finished aggregate subbase shall be firm and unyielding. Any visible movement vertically or horizontally of the aggregate subbase under the action of construction equipment or other maximum legal axle loads shall be considered as evidence that the aggregate subbase does not meet this requirement. Construction Specifications 22 Volume 3 for Public Improvements Revised October 2010 > > 25 -1.03 Grade Tolerance The subgrade to receive aggregate subbase, immediately prior to spreading, shall not vary more than 0.05 -foot above or 0.1 -foot below the grade established by the Engineer. 25 -1.05 Compacting The surface of the finished aggregate subbase shall be firm and unyielding. Any visible movement vertically or horizontally of the aggregate subbase under the action of construction equipment or other maximum legal axle loads shall be considered as evidence that the aggregate subbase does not meet this requirement. Construction Specifications 22 Volume 3 for Public Improvements Revised October 2010 Construction Specifications for Public Improvements 23 Volume 3 Revised October 2010 fie > > > Construction Specifications for Public Improvements 23 Volume 3 Revised October 2010 SECTION 26 — AGGREGATE BASE 26 -1.01 Aswres!ate Base Aggregate base shall be Class 2 conforming to and placed in accordance with the requirements of Section 26 of the Standard Specifications, with the following modifications and additional requirements. Rolling shall commence immediately after spreading of the damp material and before the material has dried sufficiently to allow separation between the fine and coarse particles. 26 -1.02 Quality Requirements The minimum sand equivalent shall be 31 for any individual test. 26 -1.05 Compacting The surface of the finished aggregate base shall be firm and unyielding. Any visible movement vertically or horizontally of the aggregate base under the action of construction equipment or other maximum legal axle loads shall be considered as evidence that the aggregate base does not meet this requirement. Construction Specifications for Public Improvements 24 Volume 3 Revised October 2010 SECTION 37 BITUMINOUS SEALS 37 -2 SLURRY SEAL 37 -2.01 Description This item shall consist of furnishing and placing a slurry seal coat on Rohnert Park City streets as designated herein in conformance with the requirements of Section 37 -2, "Slurry Seal ", of the Standard Specifications, the International Slurry Seal Association Publication A105 and as specified herein. This work consists Of preparation and application of a Type II latex modified slurry seal on various roadway sections as indicated on the plans, these specifications or as directed by the engineer . the field. A roadway will include all travel lanes, shoulders, acceleration and deceleration lanes, truck turnouts and intersections. Repair any roads, driveways, walls and curbs which are dama fed during construction, t0 their original Or better condition. Slurry Seal shall consist of mixing asphalt emulsion, areate, and water and spreading the mixture on a surface or pavement where shown on the plans, as specified in these specifications and the special provisions, and as directed by the Engineer. 37 -2.03 Materials The materials used shall conform to Section 37 -2.02 "Materials" of the Caltrans Standard Specifications, with the exceptions noted in these Technical Specifications. 37 -2.02A Asphaltic Emulsion Latex emulsified asphalt shall be a Buick traffic, Buick cure (QT -QC) type, conformin to Section 94. This emulsion shall be homogeneous and show n0 separation after thorough mixing. It shall break and set on the areate within five (5) minutes and be ready for cross - traffic within five to thirty minutes. The latex asphalt emulsion shall conform to the following requirements : Test on Emulsion I Method of Test I Requirements VISCOSlty, ASTM D244 15 -90 S SF A 77 degrees F, sec PH ASTM D244 2+/-1 Residue by Distillation ASTM D244 60% minimum Test on Residue from Distillation Test: Construction Specifications 25 Volume 3 for Public Improvements Revised October 2010 Test on Residue Method of Test Reguirements Penetration (cry, 77 100 No. 4 ASTM DS 40-80 degrees 65-90 Softening Point (Rini 40-70 No. 30 ASTM D36 130 + & Ball) de free s, F 5-15 Ductility gj5_degrees ASTM D113 25 F, 5 cm/min., min. Fraass- Breaking Point DIN 52012 —18 (de , rees C) 37 -2.02B Water Water shall be free of harmful soluble salts and shall be of such uality that the asphalt will not separate from the emulsion before the slurry seal is in place in the work. 37 -2.02C Aggregate Areate shall consist of sound, durable, crushed gravel and approved mineral filler. The material shall be free from vegetable matter and other deleterious substances. Aware „ ate shall be 100% crushed, with no round particles, and shall be volcanic in origin and black in color. The use of gray or light- colored areate will not be allowed. The percentage composition of the a �re�ate shall conform to the following radin�. PERCENTAGE PASSING Sieve Size Type II No. 3/8" 100 No. 4 94-100 No. 8 65-90 No. 16 40-70 No. 30 25-50 No. 200 5-15 The aaaregate shall conform to the following additional gqqlity requirements: Construction Specifications 26 Volume 3 for Public Improvements Revised October 2010 Test alifornia test Type II Sand Equivalent 217 70 min. Durability Index fine 229 70 min 37 -2.02D Polymer Latex. 37 -2.02E Mineral Filler. The mineral filler shall be either Portland cement or other approved mineral fillers, if required. Portland cement, if used, shall be commercially available Type I -II and shall be free of lumps and clods. 37 -2.03 Mix Design Construction Specifications 27 Volume 3 for Public Improvements Revised October 2010 37 -2.04 Proportionin" Asphalt emulsion shall be added at a rate determined by the mix design and in the range of the table above. A job mix design shall be submitted by the Contractor for approval by the En ineer that conforms to the specification limits, and that is suitable for the traffic, climate conditions, curing conditions and final use. This will include recommended application rate of slurry to suit the job conditions. Calibrated flow meters shall be provided to measure both the addition of water and licluid additives to the pub mill. If necessary for workability, a retarding went, that will not adversely affect the seal, may be used. 37 -2.05 Mixing and Spreading Equipment B' Mixing and spreading eciuipment shall be in accordance with the Caltrans Standard Specifications, Section 37 -2.04 and 37 -2.05, respectively, and as specified herein. The Slurry Seal shall be mixed in a self - propelled mixing machine eciuipped with a continuous flow pug mill capable of accurately delivering and automatically proportionin the aggr ate, emulsified asphalt, water and additives. The slurry seal retention time in the pub mill shall be less than three seconds. No retention of mixed slurry seal shall be allowed within the pug mill by gqte shut-off or other mechanical means. The mixing machine shall have sufficient storage capacity of are ate, emulsified asphalt, and water to maintain an adequate supply to the proportioning controls. The mixing machine shall be ecuipped with controls for proportioning the material to the mix. Each material control device shall be calibrated, properly marked, and lockable at the direction of the Engineer. The mixing machine shall be ecuipped with an approved fines feeder that provides a uniform, positive, accurately metered, amount of a mineral filler, if used, at the same time and location that the ag�regate is fed. The mixing machine shall be equipped with measuring device that allows-for-quick- accurate measurement of the volume. The mixing machine shall be eciuipped with a water pressure system and nozzle tape spray bars to provide a water spray immediately ahead of the spreader box. Ga es or approved means of measurement shall be provided on the equipment so that the proportional rates of are ate, water and asphalt emulsion can be checked at intervals determined by the Eqgineer. The rear flexible strike -off blade shall be capable of being adiusted to the various crown shapes so as to apply a uniform slurry seal. Any burlap drab used shall be replaced when it loses its flexibility. Construction Specifications for Public Improvements ME Volume 3 Revised October 2010 The Contractor shall calibrate the spreader vehicle(s) to be used on the project to the approved mix design prior to their arrival at the job site, and shall furnish the Engineer a copy of the calibration settings for each vehicle. Thereafter, no adjustments in the a re ate and emulsion settings shall be made without the approval of the En ineer. The Contractor shall demonstrate the ability to mix and apply slurry in a satisfactory manner and to the approved mix design with each spreader vehicle. The Contractor may not begin work until the ability to apply slurry as specified is demonstrated to the En ineer. 37 -2.06 Placing Prior to sealing each street, the Contractor shall verify that each street to be sealed has been "approved for sealin " b , the Inspector. Surface to receive slurry seal shall be prepared in accordance with the requirements specified for preparing surfaces to receive asphaltic emulsion as specified in Section 37 -1.04, "Preparation for Seal Coat ", of the Caltrans Standard Specifications. Three working days prior to the slurry seal operations, the contractor shall notify all residents, businesses and agencies with an approved written notice detailing the streets and limits of work to be done along, with the hours of work. The contractor shall also post all streets with temporary "No Parking - Tow Away" sins at 50 foot staered intervals. These sins shall also state the day of the week and hours of no parkin. Immediately preceding the seal application, the Contractor shall cover all grates, slotted manholes, and other appurtenances on and adjacent to the pavement that would allow the entry of the sealing materials; mask with roofing paper, all closed manhole covers, water and has valve box covers, monuments, monument boxes, etc.; and remove all existing raised pavement markers, paint and thermoplastic pavement markings. No adhesive material shall be permitted to cover, seal or fill the joint between the frame and cover of the structure. Construction Specifications for Public Improvements 30 Volume 3 Revised October 2010 Drainage inlets, shall be uncovered and cleaned to the satisfaction of the Engineer as soon as the seal sets. The other surface utilities shall be uncovered and cleaned of slurry material by the end of the same work day at each location. If they are not uncovered within this time frame, no additional seal shall be placed until they are uncovered. Gutters, curbs, sidewalks, driveways, shoulders and other structures adjacent to the pavement to be slurry sealed shall e cleaned of excess seal tot the satisfaction oft the Engineer. Asphalt pavement, concrete curb, butter, sidewalk, and other concrete surface structures alone existing streets damaged by the Contractor's operations, including but not limited to walkways, lawns and other landscaping, fences, gates, driveways, walls and mail boxes shall be replaced in kind by the Contractor. Hand tools shall be available in order to remove spillage. Ridges or bumps in the finished surface will not be permitted. The mixture shall be uniform and homogeneous after spreading on the existing surface and shall not show separation of the emulsion and a2,,are ate after setting. Full compensation for protecting and repairing property as specified herein shall be considered as included in the price paid for other items of work, and no additional compensation will be allowed therefore. The slurry seal shall be mixed, spread, and placed in accordance with the provisions of Caltrans Standard Specifications Section 37 -2, with the following exceptions and additions: The slurry seal shall not be applied when either atmospheric or pavement temperature is 55° F and falling but may be applied when both the atmospheric or pavement is 50° F and rising. The slurry seal shall not be applied urine periods of a norma y high relative humidit y that pro on , , the curing beyond a reasonable time. Slurry seal shall not be applied when raining or foggy. Slurry seal shall not be applied when freezing or rain is expected within 24 hours. The slurry seal mixture shall not be applied prior to 8:00 A.M. Also, the slurry seal mixture shall not be applied after 3:00 P.M., except if approved by the Engineer. Approval of applications after 3:00 P.M. will only be for the purpose of completing the section of work then underway. Be inning a new section of work after 3:00 P.M. will not be permitted. The slurry mixture shall be uniformly spread. The rear flexible strike -off blade shall make close contact with the pavement. Construction Specifications for Public Improvements 31 Volume 3 Revised October 2010 Wheel tracks, footprints, and other undesired markings in the slurry seal shall be repaired to the satisfaction of the Engineer. Treated areas will be allowed to cure until such time as the Engineer permits their opening to traffic. Fourteen days after completion of the slurry sealing, the contractor shall sweep the roadway section including all slurry sealed areas and all gutters to remove accumulated fines from the roadway surface. Thirty days after completion of the slurry sealing, the contractor shall sweep the roadway section including all slurry sealed areas and all gutters to remove accumulated fines from the roadway o surface. Construction Specifications for Public Improvements 33 Volume 3 Revised October 2010 . . . . . . . . . . . . It It It It Start and finish of slurry application shall be a straight line obtained by laying a strip of Immediately prior to the sealing operation, the Contractor will completely clean the r four minutes. A sufficient amount of slurry shall be carried in all parts of the spreader at all spreader box. No streaks such as caused by oversized aggregate pavement will be lefr in the finished Construction Specifications for Public Improvements 36 Volume 3 Revised October 2010 rubbish, equipment and temporary structures associated dailr4esis-- with the performance of work on a . Construction Specifications for Public Improvements 36 Volume 3 Revised October 2010 . . qyand Construction Specifications for Public Improvements 36 Volume 3 Revised October 2010 SECTION 39 — ASPHALT CONCRETE 39 -1.01 Description Asphalt concrete surface and the placing thereof shall conform to the requirements of Section 39 of the Standard Specifications. A minimum of two weeks prior to the placement of any Asphalt Concrete, the Contractor shall notify the Engineer of which asphalt plant will be used to supply the mix. For any job, Asphalt Concrete shall be supplied from a single plant. 39 -2.01 Asphalts The amount of asphalt binder to be mixed with the aggregate will be specified by the Engineer at the time of paving. A different asphalt binder content may be specified for each lift and each location. Asphalt binder to be mixed with aggregate for Asphalt Concrete surface, leveling, or Open Graded courses shall be PG -64 ^ u n nnn grade paving asphalt. 39 -2.02 Asmres!ate The aggregate grading of the various types of Asphalt Concrete shall conform to one of the following as directed by the Engineer: Surface Course Leveling Course Asphalt Concrete Base Open Graded 39 -4.01 Grade Tolerance Type A — 1/2" Maximum, Medium or Coarse, or 3/4" Maximum, Coarse Type A —3/4" Maximum, Medium Type A or B —3/4" Maximum, Medium 3/8" Maximum The subgrade to receive Asphalt Concrete or Asphalt Concrete Base immediately prior to applying prime coat, shall not vary more than 0.05 -foot above or below the grade established by the Engineer. Construction Specifications for Public Improvements 37 Volume 3 Revised October 2010 39 -4.02 Prime Coat and Tack Coat Prime coat shall consist of either SC -70 or MC -70 grade liquid asphalt as directed by the B. A paint binder (Tack Coat) shall be applied on asphalt to asphalt seams and joints as specified in Section 39 -4. Prime Coat and Paint Binder (Tack Coat)," of the State Standard Specifications. C. Before placing asphalt concrete, an asphalt emulsion tack coat of 70 percent CSS -1 and 30 percent water shall be furnished and applied uniformly to contact surfaces of all cold pavement joints, curbs, gutters, and all existing pavement to be surfaced in conformance with Section 39 of the Caltrans Standard Specifications. Apply a tack coat of emulsion at a rate of approximately 1 liter /m2 (0.2 al /yd2) to the sides of the repair area. D. If cut does not extend to subrade, apply prime coat to prepared subbase at 0.2 to 0.25 gallons per sq. yard to fill all void and interstices and uniformly coat sub grade E. Asphalt emulsion tack coat shall be applied to any course in advance of spreading the next course at 0.10 to 0.15 gallons per sq yard. Tack coat shall be applied between all asphalt concrete lifts. If successive lifts are paved on the same and when the surface temperature of the lower lift has not fallen below 150 °F, and the surface of the lower lift is clean, then the tack coat between lifts can be eliminated. F. Asphaltic Concrete shall not be placed until the asphaltic emulsion tack coat has cured. Following application of the prime coat, at least twenty -four (24) hours shall elapse before placing Asphalt Concrete. Any excess asphalt primer shall be blotted up with sand and removed from the grade. Tack coat shall be diluted SS 1 or C S S 1, or undiluted RS -1 or CRS -1 type asphalt emulsion. 39 -5 Hauling, Spreading, and Compacting Equipment 39 -5.01 a °' �T °''� °' °�Transportin Asphaltic Concrete Construction Specifications 38 Volume 3 for Public Improvements Revised October 2010 E. During periods of cold weather or for long distance deliveries, pre- insulation around entire truck bed surfaces. 39 -5.021 Spreading Equipment The Asphalt Concrete shall be deposited from the haul vehicle into the hopper of the paving machine. The practice of depositing the material on the roadbed in a windrow and subsequently using a pick -up machine to deposit the material in the hopper of the asphalt paver will not be allowed. All asphalt shall be placed in such a manner as to avoid separation. 39-5.,0203 Compacting Equipment Compaction rollers shall be either 2 -axle steel -tired rollers, pneumatic -tired rollers, or approved double -drum vibratory rollers. Steel -tired static compaction rollers shall weigh not less than 12 tons. Double -drum vibratory rollers shall be operated at a maximum speed of 135 -feet per minute (approximately LS mph). Double drum - vibratory rollers shall have a minimum frequency of 2400 VPM and the amplitude shall be field - adjustable. All pneumatic -tired rollers shall be equipped with an approved wind skirt unless otherwise permitted by the Engineer. Pneumatic -tired rollers used for compaction of Asphalt Concrete Base shall be so equipped that the air pressure in all tires may be regulated uniformly by the operator while the roller is in motion. Finish rollers shall be 2 -axle steel -tired tandem rollers weighing not less than 8 tons. Construction Specifications 39 Volume 3 for Public Improvements Revised October 2010 39 -6 Spreading and Compacting 39 -6.01 General Requirements Asphalt Concrete shall not be placed on any roadbed until all utility construction beneath the roadbed has been completed, sewer and water lines have been tested, and water lines chlorinated. The surface course of Asphalt Concrete shall not be placed until final utility connections have been made, unless otherwise permitted by the Engineer. Asphalt Concrete shall not be placed after thirty (30) minutes before sunset, as established by weather bureau, except as otherwise authorized by the Engineer. Asphalt Concrete or Asphalt Concrete Base shall not be placed during rainy weather or on a wet surface. Asphalt Concrete shall not be placed when the atmospheric temperature is below fifty (50) degrees Fahrenheit or conditions indicate it will drop below fifty (50) degrees Fahrenheit before the material can be satisfactorily compacted. Asphalt Concrete Base shall not be placed when the atmospheric temperature is below forty (40) degrees Fahrenheit or conditions indicate it will drop below forty (40) degrees Fahrenheit before the material can be satisfactorily compacted. Material which cannot be placed in compliance with these requirements shall be rejected. The compacted thickness of Asphalt Concrete layers shall be as directed by the Engineer. The normal minimum and maximum compacted lift thickness for Asphalt Concrete surfacing are 0.17' and 0.25' respectively. The normal minimum and maximum compacted lift thickness for Asphalt Concrete Base are 0.25' and 0.33-50' respectively. No layer shall be placed over a layer until the temperature at mid depth is not more than 160 degrees Fahrenheit. 39 -6.03 Compacting The temperature of the Asphalt Concrete shall be specified by the Engineer. Unless lower temperatures are specified by the Engineer, all mixtures shall be spread, and the first coverage of initial or breakdown compaction shall be performed, when the temperature of the mixture is not less than 250° Fahrenheit at mid - depth, and all breakdown compaction shall be completed before the temperature of the mixture drops below 200' Fahrenheit at mid - depth. Additional rolling equipment shall be required or the rate of spread shall be reduced to permit compliance with this requirement. A. Asphalt Concrete surface course and leveling courses. 1. Equipment Required. If production in any one hours exceeds the limits set forth below, the Contractor shall cease his paving operation until additional rolling equipment has arrived on the project. a. 125 tons per hour or more. Construction Specifications 40 Volume 3 for Public Improvements Revised October 2010 The Contractor will be required to furnish a minimum of two approved double -drum vibratory rollers and one 8 -ton tandem finish roller for each asphalt paver, with a separate operator for each roller. A pneumatic roller may be substituted for one of the vibratory rollers if approved by the Engineer. b. 50 -125 tons per hour. The required minimum rolling equipment specified above may be reduced to one approved double -drum vibratory roller and one 8 -ton tandem roller for each asphalt paver, with a separate operator for each roller when the compacted thickness is not less than 0.17' . C. 50 tons per hour or less, at any location. The required minimum rolling equipment specified above may be reduced to one approved double -drum vibratory roller, weighing not more than 12 tons, for each paving machine. 2. Compaction Requirements. Compaction rolling shall consist of a minimum of four complete vibratory coverages with an approved double -drum vibratory roller. Finish rolling shall consist of one or more coverages with an 8 -ton tandem roller immediately following completion of compaction rolling. B. Asphalt Concrete Base. 1. Equipment required. The Contractor shall be required to furnish one approved double -drum vibratory roller and a minimum of one pneumatic -tired roller, with a separate operator for each roller. An approved double -drum vibratory roller may be substituted for the pneumatic - tired roller specified above. 2. Compaction requirements. Compaction rolling shall consist of the following: a minimum of two complete vibratory coverages with an approved double -drum vibratory roller, and two complete coverages with a pneumatic -tired roller. The order of rolling shall be specified by the Engineer. Construction Specifications 41 Volume 3 for Public Improvements Revised October 2010 Final rolling shall consist of one coverage with the vibrating units turned off. Approval of vibratory rollers: The Engineer may approve initial use of a double -drum vibratory roller not previously approved on the basis of tests by other agencies or other information provided by the Contractor. Approval for subsequent use of the roller shall be based on cores taken from test sections designated by the Engineer and compacted with different numbers of coverages. Test sections shall be compacted under the following conditions: 1. Asphalt Concrete temperature at mid -depth shall be between 270 and 280 degrees Fahrenheit at the beginning of rolling. Rolling shall not continue after the mix temperature has dropped to 200 degrees Fahrenheit. The compacted thickness shall be between 2" and 3.5 ". 2. The Contractor or manufacturer's representative shall specify the operating conditions of frequency and amplitude. The basis for approval shall be the attainment of 97% relative compaction and satisfactory surface condition following final rolling. The number of coverages required shall be the minimum number required to obtain 97% relative compaction. The mix will be sampled during paving of the test sections, and the test maximum density will be the average density of specimens compacted in accordance with California Test 304. The in- place density for each test section shall be the average of three core densities. Relative density will be the ratio of in -place density to test maximum density as determined by Qaliforniq_Test 375. Construction Specifications 42 Volume 3 for Public Improvements Revised October 2010 39 -9 Side Street Conforms 39 -9.01 Description Side street conforms shall conform to the requirements of City of Rohnert Park Std. 208, with the following additions: The side street structural section shall be 3.5 inches of asphalt concrete base and 2.5 inches of asphalt concrete surfacing between the limits of the main street and the conform line. Beyond the conform line the existing asphalt shall be removed and replaced as directed by the Engineer to provide a smooth transition. > > > Its It 1241111.11�� 39 -9 Side Street Conforms 39 -9.01 Description Side street conforms shall conform to the requirements of City of Rohnert Park Std. 208, with the following additions: The side street structural section shall be 3.5 inches of asphalt concrete base and 2.5 inches of asphalt concrete surfacing between the limits of the main street and the conform line. Beyond the conform line the existing asphalt shall be removed and replaced as directed by the Engineer to provide a smooth transition. > > > > 39 -10 Edge Grinding 39 -10.01 Description Edge grinding shall be done per City of Rohnert Park Std. 208, 209 and 210. 39 -11 Pavement Reinforcing Fabric Pavement reinforcement fabric is allowed only with the permission of the C it Engineer. 39 -11.01 Description Construction Specifications 43 Volume 3 for Public Improvements Revised October 2010 > > 39 -11 Pavement Reinforcing Fabric Pavement reinforcement fabric is allowed only with the permission of the C it Engineer. 39 -11.01 Description Construction Specifications 43 Volume 3 for Public Improvements Revised October 2010 The fabric shall be a needle - punched non -woven 100% polypropylene fabric which conforms to the following properties: PROPERTY MIN. VALUE Tensile Strength, either direction 901bs. (Per ASTM D1682-64) Elongation at Break, either direction 50% (Per ASTM D1682 -64) Weight, oz. /sq. yd. 4.0+0.5 (Per ASTM D -1910) Asphalt Retention by Fabric 0.20 gsy (Army Corps of Engineers Method) residual Mullin Burst Strength 160 psi (Per ASTM D -751) Prior to placing the fabric, the existing pavement to receive the fabric shall be cleaned to the satisfaction of the engineer of all materials such as but not limited to leaves, sand, dirt, gravel, water and vegetation. Placement of the fabric shall be made only under the following conditions: (1) The ambient air temperature is above 50° Fahrenheit and rising. (2) The pavement is dry and the pavement temperature is above 40° Fahrenheit and rising. The surface area to receive the fabric shall be sprayed with steam refined pavement asphalt type AR -4000 at the rate of 0.22 -0.28 gallons per square yard. The Contractor's attention is directed to Section 92 -1.04, "Applying ", of the Standard Specifications. The exact rate of application will be determined by the Engineer. The asphalt shall be sprayed with a suitably metered truck or the truck must have been recently calibrated by test method California No. 399A. The temperature of the asphalt binder must be spread in the range of 290° Fahrenheit and 365° Fahrenheit. The fabric shall have no overlap. Fabric shall be butted at all joints. Transverse joints shall be shingled in the direction of paving to prevent edge pick -up by the paver. The fabric shall be placed into the asphaltic binder with a minimum of wrinkles and broomed or squeegeed to remove any bubbles prior to the binder cooling substantially enough so that the fabric will not adhere to it. The equipment for placing the fabric shall be mechanized and capable of handling full rolls of material and shall be capable of laying the fabric without forming excessive wrinkles and /or folds. As directed by the Engineer, if fabric folds or wrinkles V2 inch in height or greater exist, the fabric shall be slit and allowed to lay flat. Brooming will maximize fabric contact with the pavement surface. The equipment used to place the fabric is subject to approval by the Engineer. At each utility cover which could be covered with fabric, the fabric shall be neatly cut around the cover to allow for raising the cover to finished grade. Turning of the paving machine or other vehicles should be gradual and shall be kept to a minimum to avoid damage to the membrane. Should equipment tires tend to stick to the fabric during pavement operations, small quantities of asphalt concrete shall be broadcast ahead to prevent sticking. Pavement reinforcing fabric shall be Glasspave 25 or equivalent: Construction Specifications 45 Volume 3 for Public Improvements Revised October 2010 SECTION 39A — ASPHALT CONCRETE TRENCH PAVING 39A -1.01 Description Asphalt concrete surfacing and asphalt concrete base and the placing thereof shall conform to the requirements of Section 39 of the Standard Specifications and as specified herein. 39A -2.01 Asphalts Asphalt thickness for final asphalt surfacing shall conform to City Std. 215 or as shown on the Plans. Note to Designer: State existing section and proposed new trench asphalt concrete thickness. For temporary paving, use 1/2" maximum, medium grade aggregate and SC 3000 asphalt for use the same day, or SC 250 for use over a one week period. The amount of asphalt binder to be mixed with the aggregate will be specified by the Engineer at the time of paving. A different asphalt binder content may be specified for each lift and each location. 39A -6.01 General Requirements The Contractor shall provide compaction of backfll and base material as the job progresses, each day. Temporary paving (2" minimum) will be placed each day over the work, leaving not more than 25 feet unpaved. The balance of the trench shall be covered with steel plates, capable of sustaining normal traffic loads. Temporary A.C. paving shall be used around all edges of steel plates. Finished asphalt trench paving shall be even, smooth riding and have an appearance that is compatible to the surrounding surface. Upon placement of the last lift of Class 2 aggregate base as shown for Type A trench on City Std. 215, the Contractor shall cut the edges of pavement in a neat manner to the locations shown on said Std. 215. Construction Specifications 46 Volume 3 for Public Improvements Revised October 2010 SECTION 40 — PORTLAND CEMENT CONCRETE PAVEMENT 40 -1.01 Description Portland Cement Concrete Pavement shall be constructed in accordance with Section 40 of the Standard Specifications and as specified herein. 40 -1.04 Grade Tolerance The subgrade to receive concrete pavement, immediately prior to placing, shall conform to the compaction and elevation tolerances specified for the material involved and shall be free of loose or extraneous material. 40 -1.05 Reinforcement Reinforcement, where required, shall conform to the provisions of Section 52 of the Standard Specifications, the details as shown on the Plans, and as directed by the Engineer. 40 -1.08 Joints Expansion joints shall be constructed in accordance with the details and at the locations shown on the Plans and in conformance with the requirements of Section 73 of the Standard Specifications. - - - - - -- - - - - Construction Specifications 47 Volume 3 for Public Improvements Revised October 2010 SECTION 51— CONCRETE STRUCTURES 51 -1.02 Minor Structures Catch basins shall be constructed to the details and at the locations shown on the plans and in accordance with these Specifications. Catch basin covers shall be concrete with cast iron frame. Storm drain manholes and drop inlets shall be constructed in conformance with the details and at the locations shown on the plans and in accordance with these Specifications. 51 -1.04 Structures Storm drain manholes shall be standard 48" diameter precast concrete manholes or 60" diameter precast concrete manhole at the locations shown on the plans and in accordance with City Standard Details. Concrete for manhole bases shall be Class A portland cement concrete conforming to the applicable requirements of Section 90 of the Standard Specifications and shall be poured full thickness against the sides of the manhole excavation or shall be formed. Manhole barrels and taper sections shall be precast concrete sections using Type II portland cement complying with ASTM Designation: C150. The barrel and taper sections shall be constructed in accordance with the applicable provisions of ASTM Designation: C478. Top of manhole frames and covers shall be set accurately to the final finished grade in paved streets and to the elevation shown in unimproved areas. Concrete for catch basins shall be Class "A" portland cement concrete conforming to the requirements of Section 90 of the Standard Specifications. In lieu of the inspection of reinforcing steel as provided under Section 52 -1.04 of the Standard Specifications, upon request the Contractor shall furnish the Engineer with a certificate from the supplier of the reinforcing steel stating that the steel delivered complies with the requirements of Section 52 -1.02 of the Standard Specifications. Bar reinforcing shall conform to and be placed in accordance with Section 52 of the Standard Specifications. Connections to existing storm drain structures shall be made with care to avoid unnecessary damage to any existing curb and gutter or sidewalk. Any damaged section shall be removed and replaced in accordance with City Standards and as approved by the Engineer. Pipe connections to the existing structures shall be sealed with cement mortar. Drop inlets and grates shall be bicycle -safe and designed for H2O loading. Frame and grate shall be hot - dipped galvanized after fabrication Construction Specifications 48 Volume 3 for Public Improvements Revised October 2010 51 -1.135 Mortar 51- 1.135A Description Mortar shall consist of a mixture of Type II Portland Cement complying with ASTM C 150, sand, and water. Sand for mortar shall be clean, dry, well - graded sand, free of organic or other deleterious matter, silt or other objectionable matter, and shall be of such size as determined by laboratory sieves, that all will pass a No. 30 sieve size, square openings. Mortar shall consist of one part by volume of cement and three parts by volume of sand. The mortar shall contain only enough water to permit placing and packing. Mixed mortar shall be used before initial set and in no case will retempering with additional water be permitted. Mortar shall conform to the requirements of Section 51 -1.135 of the State Standard Specifications. 51- 1.135B Admixtures No admixtures will be permitted unless authorized by the ENGINEER. 51- 1.135C Curin After placing, all surface of mortar shall be cured by the water method in accordance with Section 90 -7, "Curing Concrete" of the State Standard Specifications, for a period of not less than 3 days. Construction Specifications 49 Volume 3 for Public Improvements Revised October 2010 SECTION 56 — SIGNS Street name signs and traffic regulatory signs and hardware which are not to be mounted on traffic signal mastarms or poles shall be provided and installed by the Contractor at the locations shown on the Plans and Part III of the City Traffic Standards. Existing street name signs and traffic regulatory signs which are not on traffic signal mastarms /poles shall be relocated as shown on the Plans by the Contractor. New street name signs and traffic regulatory signs and brackets to be mounted on traffic signal mastarms /poles shall be provided and installed by the Contractor. Existing street name signs and traffic regulatory signs on traffic signal mastarms /poles will be relocated by the Contractor. Construction Specifications 50 Volume 3 for Public Improvements Revised October 2010 Ohl* aflownnnA wifl bA madA thArAforA. Construction Specifications 50 Volume 3 for Public Improvements Revised October 2010 Where shown on 111,1111 If lik I the Plans, inlet and outlet structures shall be constructed or installed in A starter section shall troweling be used at the beginning of each run the cast -in -place concrete pipe of cast -in -place concrete pipe, on continuous runs. and • maintain a humid condition within the pipe for a minimum of seven days. • Construction Specifications 52 Volume 3 for Public Improvements Revised October 2010 SECTION 63 - CAST -IN -PLACE CONCRETE PIPE 63 -1.02 Materials Consistency of the concrete shall be determined in accordance with ASTM C 143. Maximum slump shall be 2- inches. 63 -1.03 Inspection For private development projects, full time inspection of all public cast -in -place concrete pipe shall be provided by the project developer. The name and contact information for the specialty inspector shall be submitted to the City Public Works Department two weeks prior to commencement of pour. No pipe shall be poured without the presence of the specialty inspector onsite. Within 30 days of completion of pour, the private inspector shall submit to the City an inspection report listing dates, locations, measured wall thickness, and other details of the inspection. The private inspector's report shall certify that the pipe meets the requirements of the specifications and shall be stamped and signed by a registered civil engineer. No paving or other construction over the pipe, except backfi lling, shall proceed prior to City approval of the private inspector's report. The private inspector shall comply with OSHA requirements for permit - required confined spaces per Federal Register 29 CFR part 1910.146. 63 -1.05A Structures Where shown on the plans, inlet and outlet structures shall be constructed or installed in connection with cast -in -place concrete pipe. Where such structures are constructed or installed, the ends of pipes shall be placed flush or cut off flush with the structure face, unless otherwise directed by the Engineer. A starter section shall be used where the beginning of a run of cast -in -place concrete pipe is at a structure, and a closing section shall be used where a run cannot be completed because of lack of clearance ahead in the trench. Starter sections, as required, shall be 6 feet in length and of the same inside diameter as the cast -in -place concrete pipe. Manhole bases and or structures may be formed by opening and troweling the cast -in -place concrete pipe on continuous runs. Structures shall be as described in Section 65 -1.04 of the City of Rohnert Park Construction Specifications for Public Improvements. 63 -1.06 Curing and Protecting Concrete (The following shall apply in lieu of Sec. 63- 1.06.) Backfill shall be placed in accordance with Std. 215 of the City of Rohnert Park Design and Construction Standards, except that the pipe bedding specifications shall not apply. Curing and protecting concrete shall comply with the following requirements: Construction Specifications 53 Volume 3 for Public Improvements Revised October 2010 The concrete shall be cured by placing trench backfill complying with the specifications contained in Std. 215 to an approximate depth of 0.5 foot following application of either a waterproof membrane or a pigmented curing compound as provided in Section 90 -7, "Curing Concrete." Hand spraying of the curing compound will be permitted. During the period following the placement of the concrete, the ends of the pipeline shall be covered with suitable material to maintain a humid condition within the pipe for a minimum of 7 days. Initial backfill placement shall be made immediately after the concrete has hardened sufficiently to prevent damage to the pipe during backfill operations. The concrete pipe shall be protected as provided in Section 90 -8, "Protecting Concrete." After the pipeline has been completed, but not prior to 7 days following the placement of the concrete, the Contractor shall backfill the pipe trench in accordance with the requirements of Std. 215. In all cases, the Contractor shall be responsible for correcting any damage to cast -in -place concrete pipe caused by premature or excessive loading prior to the end of a 7 -day curing period. 63 -1.07 Television Inspection of Cast -in -Place Concrete Storm Drain Pipe Television inspection of cast -in -place concrete storm drain pipe shall be as described in Section 79 of the these Specifications. Construction Specifications for Public Improvements 54 Volume 3 Revised October 2010 SECTION 64 — ASBESTOS CEMENT PIPE SECTION REPLACED TE- Asbestos cement pipe is not authorized for use within the City of Rohnert Park. Construction Specifications for Public Improvements 55 Volume 3 Revised October 2010 SECTION 64 — PLASTIC PIPE 64 -1.01 Description All plastic storm drain pipe shall be type S corrugated polyethylene pipe. 64 -1.02 Size and Materials Plastic pipe for use in public storm drain systems shall be Type S, smooth interior wall, corrugated exterior wall, high density polyethylene pipe (HDPE) as specified in AASHTO designation M294. Pipe shall be manufactured from virgin compounds with no plasticizers. HDPE compounds used in the manufacture of plastic pipe shall be per the Standard Specifications. 64 -1.04 Couplings and Fittings Pipe couplings and fittings shall be a bell and spigot joint with a rubber gasket on the spigot meeting ASTM F -477 and shall provide a soil -tight seal and be made of the same material and from the same manufacturer as the pipe. The method of joining pipes and fittings shall be as recommended by the pipe manufacturer. Pipes and fittings coupled together shall have no more than one corrugation distance of separation between them. 64 -1.05 Excavation and Backfill Excavation and backfll shall be as shown on Std. 215 of the City of Rohnert Park Design and Construction Standards and the following provisions. The space between the pipe and trench wall shall be wider than the compaction equipment used in the pipe zone, regardless of the dimensions shown on the Std. 215 unless sew compazlingCLSM backfill material is used. Pipe bedding will be placed in 6" (maximum) lifts to 6" above the top of pipe with each lift hand or mechanically tamped. The final lift may be compacted with a plate type vibrating compactor. During construction, heavy equipment vehicle loads shall be avoided over the pipe or additional cover shall be placed at vehicle crossings. 64 -1.07 Laving Pipe Plastic storm drain pipe shall be installed in accordance with the Standard Specifications, generally accepted practice and on the alignment and grade as shown on the plans. When long radius curves are permitted, adjustments in horizontal alignment will be achieved through adjustments at each coupling, within manufacturer's specification, and not by bending of the pipe. Pipe shall be centered in the trench. Construction Specifications 56 Volume 3 for Public Improvements Revised October 2010 Unless otherwise specifically permitted by the Engineer, all pipe shall be laid upgrade. Where ground water or surface drainage occurs, pumping shall continue until backfilling has progressed to a sufficient height to prevent flotation of the pipe. 64 -1.10 Television Inspection of Plastic Storm Drain Pipe Television inspection of plastic storm drain pipe shall be as described in Section 79 of these Specifications. 64 -2.01 Trench Shoring and Bracing - Storm Drain All bracing and shoring shall conform to Section 65 -2 of these Specifications. Construction Specifications 57 Volume 3 for Public Improvements Revised October 2010 R . . I 'All Ella sow 1 11111111'll1l111111111111 1. . • the supplier of the reinforcing steel stating that the steel delivered complies with the vi lb I prke 7L jLxxg . . . . . . . . . . . . 4f III Ift, SECTION 65 — REINFORCED CONCRETE PIPE 65 -1.01 Description Reinforced concrete pipe shall be installed on the alignment and grade as shown on the plans and in accordance with the applicable provisions of Section 65 of the City of Rohnert Park Construction Specifications and as directed by the Engineer. Reinforced concrete pipe shall be Class III, Class IV, or Class V, as shown on the plans, and shall conform to the provisions of ASTM C76. 65 -1.02 Materials All concrete pipe shall conform to the provisions of Section 65 -1.02 of the Standard Specifications prior to shipment from the manufacturer. 65 -1.03 Earthwork Excavation and backfill shall conform to the City of Rohnert Park Construction Specifications. Backfill shall be in accordance with Std. 215 and as shown on the plans. If, during excavation for any culvert or structure, material is encountered which is unsuitable as a foundation for such culvert or structure, such unsuitable material shall be removed to a depth as required by the Engineer and the resulting space shall be refilled with approved material. Trenching operations shall be conducted in such a manner as not to disturb the existing curb and gutter and existing utilities. Trenching operations for pipelines and structures shall be conducted in such a manner to minimize damage to existing tree roots. Hand digging shall be used where necessary to protect tree roots. Where tree roots are encountered, root pruning shall be accomplished by use of sharp tools appropriate for the size of root to be cut. Each cut shall be clean with no torn bark or splintered wood remaining on the tree. All tree work shall be performed by a certified arborist from the list approved by the City. All raised pavement markers, street striping, chatter bars or any other traffic markings disturbed during work shall be replaced in kind by the Contractor to the satisfaction of the Engineer. Excavation and backfill shall be as shown on Std. 215. 65 -1.07 Laying Cylyff±Pi e Unless otherwise specifically permitted by the Engineer, all pipe shall be laid upgrade. No pipe shall be laid which is cracked, checked, spalled, or damaged and which, in the opinion of the Engineer, is unsuitable for use. Construction Specifications 61 Volume 3 for Public Improvements Revised October 2010 Connections to existing storm drain structures shall be made with care to avoid unnecessary damage to any existing curb and gutter or sidewalk. Any damaged section shall be removed and replaced in accordance with City Standards and as approved by the Engineer. Pipe connections to the existing structures shall be sealed with cement mortar. Proper implements, tools, and facilities satisfactory to the Engineer shall be provided and used by the contractor for the safe and efficient execution of the work. All pipe, fittings, and accessories shall be carefully lowered into the trench by means of derrick, ropes, or other suitable equipment in such a manner as to prevent damage to pipe and fittings. Under no circumstances shall pipe or accessories be dropped or dumped into the trench. The pipes and accessories shall be inspected for visible defects prior to lowering into the trench. Any visibly - defective or unsound pipe shall be replaced. The line and grade of existing utilities designated to remain shall not be altered. Any leakage caused in existing utilities by reason of the Contractor's operations shall be immediately repaired at the Contractor's expense. Existing water lines shall be supported in place maintaining service during construction. The Contractor shall be responsible for any damage to the water lines during construction and any damage resulting from improper backflling techniques. Water services shall be relocated where encountered during construction and as shown on the plans. Existing sewer lines shall be supported in place maintaining service during construction. The Contractor shall be responsible for any damage to the sewer lines during construction and any damage resulting from improper backflling techniques. 65 -1.08 Television Inspection of Reinforced Concrete Storm Drain Pipe Television inspection of cast -in -place concrete storm drain pipe shall be as described in Section 79 of the these Specifications. 65 -2 Trench Bracing and Shoring - Storm Drain 65 -2.01 Description All bracing and shoring shall conform to Section 5 -1.02A and Section 7 -1.01E of the Standard Specifications and the Division of Industrial Safety Construction Safety Orders which are currently in use. The Contractor shall take all necessary measures to protect the workers and adjacent areas and structures from the hazards of the trenching or excavation operations. Construction Specifications 62 Volume 3 for Public Improvements Revised October 2010 SECTION 66 — CORRUGATED METAL PIPE 66 -1.01 Description All corrugated metal pipe shall meet the requirements of Section 66 of the Standard Specifications. Corrugated aluminum pipe, if used, shall meet the requirements of Section 66 -2 of the Standard Specifications. Construction Specifications 63 Volume 3 for Public Improvements Revised October 2010 > quipmen> ovnnvntion n���I Construction Specifications 63 Volume 3 for Public Improvements Revised October 2010 Construction Specifications -164 Volume 3 for Public Improvements Revised July 2010 SECTION 71— SEWERS 71 -1.02 Materials Sewer pipe to be installed shall be ductile iron pipe, high density polyethylene, or polyvinyl chloride pipe, in conformance with the appropriate provisions of the City Construction Specifications, Section 71, Standard Specifications for Public Works Construction, as noted on the Plans and as specified herein. Asbestos cement pipe shall not be allowed. 71 -1.02A Polyvinyl Chloride (PVC) Pipe PVC solid wall sewer pipe and fittings for gravity sewer shall be made from all new, rigid, un- plasticized polyvinyl chloride in accordance with ASTM Standard Specifications D3034 and F679 and shall have a wall thickness of at least SDR 26. Joints shall consist of an integral thickened bell- and - rubber ring and shall provide for expansion and contraction at each joint. The rubber ring shall be compatible with the pipe manufacturer's recommended lubricant. All pipe shall have a home mark to indicate full penetration of the spigot when the joint is made. All PVC pipe entering or leaving a concrete structure shall have an elastomeric waterstop firmly clamped around the pipe exterior and cast into the structure base per City Standard 500 or near the structure wall center per City Standard 533. 71 -1.02B Restrained Joint (PVC) Pipe and Fittings Restrained joint PVC pipe and fittings shall conform to the requirements of ASTM D2241. Joints shall be gasketed and conform to the requirements of ASTM D3139 and ASTM F477. Use only full circle type restraint clamps. Restraint systems that use set screws that impose point loads on the pipe will not be permitted. 71 -1.02C Ductile Iron Pipe Ductile iron pipe shall be cement lined, new pipe conforming to ANSI A 21.51 -197s or most recent issue, if any as sponsored by the American Water Works Association for thickness Class 50 Ductile Iron Pipe. The pipe shall be furnished with either bell and spigot ends, "Tyton Joints," or mechanical joints, except where specifically specified on the Plans. Ductile iron pipe used in force mains shall be polyethylene or epoxy lined. All ductile iron pipe buried underground shall be encased in polyethylene film in the tube form. Polyethylene material and installation procedure for the encasement shall conform to ANSI /AWWA C105/A21.5-82 or most recent issue, if any. Installation Method "A" as described in aforementioned specification shall apply. 71 -1.02D Ductile Iron Restrained Joint Fittings Restrained joint fittings shall be ductile iron in accordance with applicable requirements of ANSI /AWWA C 111 /A21.11 and ANSI /AWWA C 153/A21.53 of latest revision and shall be compatible with the type and pressure class of pipe used. 71 -1.02E Sewer Force Main and Gravity HDPE Pipe The Contractor shall provide high density polyethylene pipe (HDPE) as specified. The pipe shall be made to diameter and tolerances in accordance with ASTM F714. All pipe shall be made from virgin grade material. The pipe shall be of the diameter and class shown or specified and shall be furnished complete with all fabricated fittings, and other appurtenances as necessary for a complete and functional system. Markings: Pipe materials shall be legibly marked by the pipe manufacturer. The following shall be printed on the pipe: 1. Name and trademark of manufacturer. 2. Nominal pipe size. 3. Standard Dimension Ratio. 4. The letters PE followed by the polyethylene grade per ASTM D1248 followed by the Hydrostatic Design Basis in hundreds of psi. 5. Manufacturing Standard Reference. 6. A production code from which the date and place of manufacture can be determined. The Contractor shall provide submittals to the Engineer for approval on all materials. Quality Control Submittals: 1. HDPE Pipe, Butt - Fusion Welded Joints: a. The Contractor shall provide written verification that personnel using the fusion joining equipment are trained in the skills necessary for the correct joining of HDPE pipe and recommended methods for service connections to the satisfaction of the pipe supplier. Certification of the training shall be provided from the certified representative of the pipe manufacturer. b. Fusion equipment shall be operated only by technicians who have been certified by the pipe manufacturer or supplier and who have a minimum of five (5) years of experience fusion welding pipelines. The technician's experience shall be documented in the HDPE pipe submittal, including a current (within the past three years) training certificate. c. The Contractor shall perform trial fusion welds and submit samples to the Engineer for review prior to installation of the pipe. Full penetration welds shall provide a homogeneous material across the cross section of the weld. The fusion Construction Specifications -166 Volume 3 for Public Improvements Revised July 2010 machine and technicians employed for the trial welds shall be the same utilized for the installation work. d. Quality assurance procedures certified by the pipe manufacturer to be in full accordance with the requirements of this Specification shall be submitted by the Contractor. 4. Certification. The Contractor shall furnish a certified affidavit of compliance for all HDPE pipe and fittings furnished confirming that the materials supplied fully conform to the requirements specified herein. 5. Certifications of Calibration: Approved testing laboratory certificate or manufacturer's calibration certificate. 6. Quality assurance procedures shall be performed by the pipe manufacturer fully in accordance with the requirements of this specification. The certification shall include certified laboratory data confirming that said tests have been performed on a sample of the pipe to be provided under this contract, or pipe from that production run, and that satisfactory results were obtained. Shop Drawings: 1. The Contractor shall submit catalog cuts, specifications, dimensioned drawings, installation details and sketches, and other pertinent information for the HDPE pipe installation work. All materials provided shall be in full accordance with the requirements of the reference specifications specified above. 2. The Contractor shall verify with the pipe manufacturer all connection details. 3. The Contractor shall submit detail drawings and a written description of the construction procedure to install pipe. Pipe shall be high molecular weight, high- density polyethylene pipe. The material shall be listed by the Plastic Pipe Institute (PPI) with a designation of PE 3608 and have a minimum cell classification of 345464C, D, or E as described in ASTM D3350. The pipe material shall meet the requirements for Type III, Class B or C, Category 5, Grade P34 material as described in ASTM D1248. The pipe shall contain no recycled compound except that generated in the manufacturer's own plant from resin of the same specification from the same raw material pipe. Pipe and fittings shall be made in conformance with ASTM F714 and ASTM D3261 as modified for the specified material. The pipe shall be homogeneous throughout and free of visible cracks, holes, foreign inclusions or other injurious defects. It shall be uniform in density and other physical properties. Any pipe not meeting these criteria shall be re.ected. Only tools approved by the pipe manufacturer or the Engineer shall be used for assembly of pipe fittings and service connections to ensure proper installation. The heater plate used for pipe joining shall be equipped with suitable means, such as thermometers or pyrometers, to measure the temperature of plate surfaces and to ensure uniform heating. Construction Specifications -167 Volume 3 for Public Improvements Revised July 2010 Butt fusion fittings shall be in accordance with ASTM D3261 and shall be manufactured by injection molding, a combination of extrusion and machining, or fabricated from HDPE pipe conforming to this specification. All fittings shall be pressure rated to provide a working pressure rating no less than that of the pipe. Fabricated fittings shall be manufactured using a McElroy Data logger to record fusion pressure and temperature. A graphic representation of the temperature and pressure data for all fusion joints made producing fittings shall be maintained as part of the quality control. The fitting shall be homogeneous throughout and free of visible cracks, holes, foreign inclusions, voids, or other injurious defects. Each polyethylene fusion fitting shall meet all the material requirements established for the pipe to which the fitting is to be jointed. Fittings fabricated from pipe shall be manufactured from pipe stock with a wall thickness at least 25% greater than that of the pipe to which the fitting is to be joined or shall be otherwise externally reinforced so that the fitting carries a pressure rating equal to that of the pipe from which it is made. Each fitting shall be designed and manufactured to operate at not less than the design pressure of the pipe system for which it is intended. Polyethylene pipe shall be joined by butt fusion welding, as specified herein. RESTRAINED JOINTS: Mechanical restraint for HDPE may be provided by mechanical means separate from the mechanical joint gasket sealing gland. The restrainer shall provide wide, supportive contact around the full circumference of the pipe and be equal to the listed widths. Means of restraint shall be machined serrations on the inside surface of the restrainer equal to or greater than the listed serrations per inch and width. Loading of the restrainer shall be by a ductile iron follower that provides even circumferential loading over the entire restrainer. Design shall be such that restraint shall be increased with increases in line pressure. Serrated restrainer shall be ductile iron ASTM A536 -80 with a ductile iron follower; bolts and nuts shall be corrosive resistant, high strength alloy steel. The restrainer shall have a pressure rating of, or equal to that of the pipe on which it is used or 150 PSI whichever is lesser. Restrainers shall be JCM Industries, Sur -Grip or pre- approved equal. Nominal Restraint Serrations Size Width per inch 4 ", 6" 1 -1 /2" 8 8" 10 & 12" 1 -3/4" 8 Pipe stiffeners shall be used in conjunction with restrainers. The pipe stiffeners shall be designed to support the interior wall of the HDPE. The stiffeners shall support the pipe's end and control the "necking down" reaction to the pressure applied during normal installation. The pipe stiffeners shall be formed of 304 or 316 stainless steel to the HDPE manufacturers published average inside diameter of the specific size and DR of the HDPE. Stiffeners shall be by JCM Industries or pre- approved equal. Construction Specifications -168 Volume 3 for Public Improvements Revised July 2010 Install in accordance with manufacturer's recommendations and as directed herein. JOINING: BUTT FUSION: Sections of polyethylene pipe should be joined into continuous lengths on the j obsite above ground. The joining method shall be the butt fusion method and shall be performed in strict accordance with the pipe manufacturer's recommendations. The butt fusion equipment used in the joining procedures should be capable of meeting all conditions recommended by the pipe manufacturer, including, but not limited to, temperature requirements of 400 degrees Fahrenheit, alignment, and an interfacial fusion pressure of 75 PSI. The butt fusion joining will produce a joint weld strength equal to or greater than the tensile strength of the pipe itself. All field welds shall be made with fusion equipment equipped with a McElroy Data Logger. Temperature , fusion pressure and a graphic representation of the fusion cycle shall be part of the quality control records. SIDEWALL FUSION: Sidewall fusions for connections to outlet piping shall be performed in accordance with HDPE pipe and fitting manufacturer's specifications. The heating irons used for sidewall fusion shall have an inside diameter equal to the outside diameter of the HDPE pipe being fused. The size of the heating iron shall be 1/4 inch larger than the size of the outlet branch being fused. MECHANICAL: Bolted joining may be used where the butt fusion method cannot be used. Flange joining will be accomplished by using a HDPE flange adapter with a ductile iron back -up ring. Mechanical joint joining will be accomplished using either a molded mechanical joint adapter or the combination of a Sur -Grip Restrainer and Pipe Stiffener as manufactured by JCM Industries, Inc. Either mechanical joint joining method will have a ductile iron mechanical joint gland. OTHER: Socket fusion, hot gas fusion, threading, solvents, and epoxies may not be used to join HDPE pipe. QUALITY AND WORKMANSHIP: The pipe and /or fitting manufacturer's production facility shall be open for inspection by the owner or his designated agents with a reasonable advance notice. During inspection, the manufacturer shall demonstrate that it has facilities capable of manufacturing and testing the pipe and /or fittings to the standards required by this specification. PIPE PACKAGING, HANDLING & STORAGE: The manufacturer shall package the pipe in a manner designed to deliver the pipe to the project neatly, intact and without physical damage. The transportation carriers shall use appropriate methods and intermittent checks to insure the pipe is properly supported, stacked and restrained during transportation such that the pipe is not nicked, gouged, or physically damaged. manufacturer's recommendations. The pipe shall be handled in such a manner that it is not pulled over sharp objects or cut by chokers or lifting equipment. Sections of pipe having been discovered with cuts or gouges in excess of 10% of the pipe wall thickness shall be cut out and removed. The undamaged portions of the pipe shall be rejoined using the heat fusion joining method. Fused segments of the pipe shall be handled so as to avoid damage to the pipe. Chains or cable type chokers must be avoided when lifting fused sections of pipe. Nylon slings are preferred. Spreader bars are recommended when lifting long fused sections. 71 -1.03 Excavation and Backfill Backfill shall be in accordance with City Standard 215 except trench backfill section in roadways and paved areas shall be CDF. Sheet piling and other sheeting shall be withdrawn in such a manner as to prevent caving at the walls of excavations or damage to piping or other structures. Except as may be hereinafter modified, no sheeting shall be left in the trench and no backfi ll shall be made against the sheeting before it is removed. Any sheeting extending below the invert of the pipe shall be left in place by cutting off in a manner satisfactory to the Engineer. Trenching operations shall be conducted in such a manner not to disturb the existing curb and gutter and the existing utilities. Flow shall be maintained in any sanitary sewers, storm drains, water lines, or water courses encountered in trenching. The Contractor shall remove all water which may accumulate in the excavation during the progress of the work can be done in the dry. Trenches shall be kept free from water while the pipe or other structures are installed and until backfilling has progressed to a sufficient height to anchor the work against possible flotation or leakage. At all times, the Contractor shall have sufficient pumping machinery available for immediate use. Water shall be disposed of in such a manner as to cause no injury to public or private property, or be a menace to public health. Blasting will not be permitted. All trench excavation materials from trenches shall be the property of the Contractor. None of the excavation material shall be disposed of on the work site. Prior to disposal of any material, the Contractor shall submit to the Engineer written authorization for such disposal of material and entry permission signed by the owners of the disposal site, and shall comply with any other requirements of disposal, such as City and County permits, as may be required. All raised pavement markets, street striping, chatter bars or any other traffic markings disturbed shall be replaced in kind by the Contractor to the satisfaction of the Engineer. 71 -1.03A Trench Bracing and Shoring All bracing and shoring shall conform to Section 5 -1.02A and Section 7 -1.01E of the Standard Specifications and the Division of Industrial Safety Construction Safety Orders which are currently in use. The Contractor shall take all necessary measures to protect the workmen and adjacent areas and structures from the hazards of the trenching or excavation operations. Settlement monitoring shall be required for major excavations where shown on the plans, next to existing improvements or as directed by the City Engineer. 71 -1.04 Existing Manholes Existing manholes and cleanouts located within the street right -of -way shall be adjusted to conform to finished pavement grades in accordance with the details shown on City Standard 500 and as described in section 71 -1.07A of these specifications. Prior to the removal of an existing manhole frame, a platform shall be constructed in the manhole above the top of the sewer to prevent any dirt or debris from falling into the sewer. The platform shall remain in place until all work on the manhole has been completed and the asphalt concrete has been placed around the manhole. Prior to the removal of the platform from the manhole, all dirt and debris shall be removed. Lowering of the manhole ring and cover shall be accomplished by the removal of existing concrete grade rings below the manhole ring or by removing the upper section of manhole barrel and substituting therefore a shorter section of barrel. Trimming of taper sections is not permitted. All sections of removed and or replaced manhole barrels shall be sealed with a preformed mastic seal, Ram -Nek or approved equal. Exterior joints shall be taped using a 6 -inch wide 60 mil tape, Infi- shield or approved equal. After placing the surface course of asphalt concrete, all manholes and cleanouts shall be located and marked with white paint before the close of that working day. within two working days of paving, all manholes and cleanouts shall be adjusted to grade and inspected. 71 -1.05 Pipe Laying Where groundwater occurs, pumping shall continue until back filling has progressed to a sufficient height to prevent flotation of the pipe. Water shall be disposed of in such a manner as to cause no property damage or not be a hazard to public health. Where construction consists of constructing a new main or extension of an existing main, the downstream end of the new main shall be securely closed with a tight fitting plug until the construction is accepted by the Engineer. If the new sewer main is connecting to an existing main at a location other than a manhole, prior to requesting the staking, the Contractor shall pothole the existing sewer main to verify invert grades and locations. Sewer pipe shall be laid in straight lines and on uniform rates of grade between points where changes in alignment or grade are shown on the Plans. The interior of the pipe shall be free of foreign matter before lowering into the trench. The pipe manufacturer's written instructions covering the installation of the pipe shall be closely followed unless otherwise directed by the Engineer or as specified herein. After each pipe section is laid, the pipe joints shall be checked by the Contractor with a feeler gauge to determine if the rubber ring is properly seated for push on joint PVC or D.I. pipe. The trench shall not be backfilled until authorized by the Engineer. Pipe laying shall proceed upgrade with the spigots pointing in direction of flow. The invert of the pipe shall be set at required line and grade as determined from batter boards set not over 25 feet apart. Electro- optical grade setting devices may be used provided the Contractor certifies that the device will be operated by a person proficient in its operation. Any section of pipe found to be defective or which has had grade or joints disturbed shall be re- laid by the Contractor at his expense. Proper implements, tools, and facilities satisfactory to the Engineer shall be provided and used by the Contractor for the safe and efficient execution of the work. All pipe, fittings, and accessories shall be carefully lowered into the trench by means of derrick, ropes, or other suitable equipment in such a manner as to prevent damage to pipe and fittings. Under no circumstances shall pipe or accessories be dropped or dumped into the trench. The pipe and accessories shall be inspected for visible defects prior to lowering into trench. Any visibly defective or unsound pipe shall be replaced. The line and grade of existing utilities shall not be altered. Any leakage caused in existing utilities by reason of the Contractor's operations shall be immediately repaired at the Contractor's expense. storm drains. If the Contractor elects to remove and replace, backfill shall be in conformance with City Standard 215. Existing water lines shall be supported in place with service maintained during construction. The Contractor shall be responsible for any damage to the water lines during construction and any damage resulting from improper backfilling. Existing sewer lines shall be supported in place with service maintained during construction. The Contractor may, at his option, remove and replace any sewer laterals which are not in use during construction. The Contractor shall be responsible for repairing damage to sewer lines during construction and any damage resulting from improper backfilling. Sewer lateral inverts shall be set at or above the midpoint of the sewer main. Sewer laterals shall be placed at the locations shown on the Plans or as directed by the Engineer. The Engineer shall have the authority to direct the Contractor as to the location of laterals to be placed in the field. Typically, each sewer lateral found to exist shall be replaced, unless specifically deleted by the Engineer. In all cases, a minimum separation of five (5) feet shall be left between parallel sewer laterals and water services. 71 -1.07 Sewer Structures Manholes shall be standard precast concrete manholes as detailed on City Standard 500, and as shown on the Plans. Mains larger than 27" in diameter require 60" diameter manholes. Concrete manhole bases may be precast or cast -in- place. Precast concrete manhole bases must be approved by the City Engineer. Manhole bases may be poured -in -place concrete on undisturbed earth. The bases shall be poured a minimum full thickness as shown on City Standard 500 against the side of the manhole excavation or to dimensions shown on the Plans if the dimension exceeds the minimum required. The manhole excavation site shall be dewatered before pouring. Pre -cast manhole bases, conforming to City Standard 500 in dimensions and the requirements outlined below for materials may be used. Such pre -cast bases shall be placed on a minimum 6- inch thick cushion of drain rock, as specified in City Standard 500. The drain rock shall extend a minimum of 6 inches beyond the outside edges of the base. Concrete for manhole bases shall be Class A portland cement concrete conforming to the applicable requirements of Section 90 of the Standard Specifications. The portland cement shall be Type V conforming to ASTM C 150 or low - alkali -Type II cement meeting the requirements for Type V cement. The base slab and initial riser section shall be connected to create a watertight joint per City Standard 500. Flow channels shall be constructed as shown on the Plans. Changes in size or grade shall be made gradually and changes in direction by smooth curves. All finished surfaces shall be smoothly troweled with a steel trowel. All manhole barrels and taper section shall be precast concrete sections using Type V portland cement complying with ASTM C 150 or low - alkali Type II cement meeting the requirements for Type V cement. The 48 -inch and 60 -inch diameter barrels and taper sections shall be constructed in accordance with the applicable provisions of ASTM C478 and shall be inspected by the Engineer to determine that the interior surfaces are smooth and free of pockets or depressions. Manhole frames and covers shall be in accordance with City Standard 512. Tops of manhole frames and covers shall be set accurately to finished grade in paved streets and one foot above finished grade in unimproved areas. The frames shall be evenly set per City Standard 500. Where manholes are set above finished grade, the earth shall be mounded up around the manhole in a neat and acceptable manner to the satisfaction of the Engineer. Where sewer pipe is to be installed into or out of existing manholes, and the invert of the new connection penetrates the manhole barrel section, the barrel section wall shall be core drilled. The Contractor shall install an elastomeric seal and silicone caulk per City Standard 533. Where sewer pipe is to be installed into or out of existing manholes, and the invert of the new connection penetrates the manhole base the manhole base may be chipped and the Contractor shall install an elastomeric waterstop and 316 stainless steel band per City Standard 500. Form a smooth channel in the manhole base using Dam -It by Euclid. For either method the Contractor shall backfill the area around the pipe with a non - shrink grout to insure a watertight connection. All joints in manholes shall be sealed by means of a preformed, self - bonding, self - sealing plastic gasket, such as "Ram -Nek" manufactured by the K.T. Snyder Company, Houston, TX, or approved equal. Joint seals shall be installed in full compliance with the manufacturer's current recommendations. 71 -1.07A Chimney Sections All manhole castings shall be adjusted to meet final paving elevation with the installation of HDPE grade rings and shall be installed per City Standard 500 and as described herein. After final installation a final deviation of more than 0.25 inch between the top of the manhole lid and the surrounding paving at any location shall be cause for rejection. Installation of HDPE Adjusting Rings shall be per manufacture's recommendations. In order to achieve a flush finish between the top of the concrete cone section and the first HDPE grade ring the alignment tab on grade ring bottom may need to be removed so that the grade ring will sit on the manhole cone section flush and not have point loading. slab with a whisk broom . Ensure a flat seating surface free of rocks, gravel, blacktop, protruding concrete or debris. Utilize compressed air to blow dust and debris from the surface after grinding. Where the top of the concrete cone is rough, use non - shrink hydraulic cement, according to manufacturer's recommendations, to fill in depressions and smooth the concrete cone. Grinding and grouting shall be done when required to: 1. Remove any protrusions over 1/4 inch. 2. Make the manhole ring stable without any rocking prior to foaming. The HDPE adjusting ring system shall be measured in place dry prior to final assembly. The annular space between the rings and cone basin, the rings, and the rings and cover frame shall be sealed utilizing an approved construction foam in accordance with manufacturer's instructions. With the sealant applied, place the first ring down onto the cone or top slab with the male lip into the opening. The ring must be stable prior to foaming. Point loading on the ring is cause for rejection of the finished work. Prior to setting the cover frame in place, construction foam sealant shall be placed on the top of the last ring. Be sure to apply the sealant in a location so that it contacts the cover frame the full 360 degrees. With the sealant applied, set the cover in place verifying that it is centered on the top ring. Cover and frame shall be aligned per Rohnert Park City Standard 512A. Install external joint seal over the entire chimney area, extending from the cover to three inches below the top of the cone. Wrap with 60 mil inch wide corrosion prevention tape. CONCRETE COLLARS No backfllling, except with concrete, will be permitted, except over excavated areas may be filled with CLSM. Seal all saw cut grooves beyond the edge of concrete. Concrete collars shall be constructed with quick set concrete, mixture to be approved by the Engineer. Except as approved by the Engineer, Contractor shall keep traffic off of raised facilities for 24 hours. The surface of the finished concrete shall be finished 2 inches below flush with the pavement. The top surface of the cast collar shall be screeded off at the correct elevation to receive and support the full depth of the pavement surface course. Contractor shall let the 8" concrete collar cure for 24 hours prior to traffic loading. Cover manhole with steel plate during curing process. The concrete shall attain a modulus of rupture of 1,000 pounds per square inch prior to beginning paving operations. 71 -1.08 Trench Resurfacing 71 -1.09 Testing of Sewers Testing of all portions of the sewer including manholes will be required. All sewer pipes shall be tested per the appropriate test as described in City Standard 530 and 530A guidelines or as described below. Manholes shall be tested per City Standard 530B The Contractor shall furnish to the City a 5% deflection mandrel and proving ring for gravity mains as shown on City Standard 518 at the City's request. GRAVITY HDPE PIPELINES: Trunk sewers with no lateral connections between manholes constructed of HDPE shall be tested in accordance with ASTM F 1417. All other HDPE sewers shall be tested per City Standard 530 and 530B. HDPE Force Mains shall be tested as referenced in City Standard 530A. Construction Specifications -176 Volume 3 for Public Improvements Revised July 2010 Construction Specifications for Public Improvements -177 Volume 3 Revised October 2010 SECTION 72 — SLOPE PROTECTION 72 -1.01 Description Slope protection shall consist of loose rock riprap. The slope protection shall be placed at the location shown on the Plans in conformance with the requirements of the Standard Specifications and the Sonoma County Water Agency Flood Control Design Criteria Manual. 72 -2.02 Materials Loose Rock Riprap -Rocks shall be angular and well graded from an average diameter of four (4) inches to an average diameter of fifteen (15) inches with approximately fifty (50) percent by weight smaller than nine (9) inches in average diameter. Not more than ten (10) percent of the rock riprap by weight shall be less than four (4) inches average diameter. An occasional rock having an average diameter of not more than 20 inches may be included, provided that no more than five (5) percent of the rock riprap area shall have these larger rocks projecting above the neat lines, but in any event the total rock mass shall be dense and well integrated. 72 -5 Grouted Rock Riprap Grouted rock riprap shall be constructed in accordance with the details as shown on the Plans, Standard Specifications, as specified herein, and at the direction of the Engineer. Concrete for grouted rock riprap shall be in accordance with Section 90 of the Standard Specifications and shall be Class "C ". Rocks shall not exceed a one foot diameter and shall not be less than three inches in diameter. Rocks shall be so placed as to provide a minimum of voids and the larger rocks shall be placed in the toe course and on the outside surface of the slope protection. The rock may be placed by dumping and may be spread in layers with suitable equipment. Local surface irregularities of the grouted rock riprap shall not vary from the plan slopes by more than six inches, measured at right angles to the slope. The surfaces of the rock to be grouted shall be cleaned of adhering dirt and clay and moistened. Grout shall be brought to the place of final deposit by means of chutes, tubes, or buckets, or may be placed by means of pneumatic equipment or other mechanical methods. In no case shall grout be permitted to flow on the rock riprap a distance in excess of ten feet. Immediately after depositing, the grout shall be spaded and rodded into place with suitable spade trowels or other approved means until a minimum penetration of eight inches is achieved. Construction Specifications -178 Volume 3 for Public Improvements Revised October 2010 Grouted rock riprap shall be cured as provided in Section 90 of the Standard Specifications. Construction Specifications -179 Volume 3 for Public Improvements Revised October 2010 H n nce wi be mn de th Construction Specifications -179 Volume 3 for Public Improvements Revised October 2010 SECTION 73 — CONCRETE CURBS AND SIDEWALKS 73 -1.05 Curb Construction Portland cement concrete curb and gutter shall be constructed in conformance with the details and at the locations shown on the Plans and in accordance with the applicable provisions of Section 73 of the Standard Specifications and as specified herein. Curb openings, for driveways, shall be constructed at existing driveways, and at locations shown on the Plans or directed by the Engineer. All concrete which is to be removed from curb, gutter, and driveway areas shall be removed to the nearest construction joint or as directed by the Engineer. Median curb per City of Rohnert Park Standard Details shall be constructed at the locations shown on the Plans and in accordance with the applicable provisions of Section 73 of the Standard Specifications and these modifications. All oil, paint, tire marks, and other discoloring shall be removed from the curb and gutter by sandblasting prior to acceptance by the Engineer. Cement mortar will not be an acceptable substitute for sandblasting. No deduction in measured length of curb and gutter to be paid for will be made for curb openings for driveways. 73 -1.07 Sidewalk, Driveway, Island Paving, Handicap Ramp, and Valley Gutter Construction Portland cement concrete sidewalk shall be constructed in accordance with the details and at the location shown on the Plans and in conformance with the requirements of Section 73 of the Standard Specifications and as specified herein. All concrete which is to be removed from sidewalk and driveway areas shall be removed to the nearest transverse score mark across the full width of sidewalk or construction joint as directed by the Engineer. Concrete for sidewalk shall conform to the requirements of Section 73 of the Standard Specifications. All soft or spongy material shall be removed and replaced with suitable material as required by the Engineer. Island paving shall be constructed in accordance with the details and at the location shown on the Plans, and as directed by the Engineer. Handicap ramps shall be constructed in accordance with the details and at the locations shown on the Plans per City Std. 232. Portland cement concrete valley gutter shall be constructed in accordance with the details and at the location shown on the Plans and in conformance with the requirements of Section 73 of the Standard Specifications and City of Rohnert Park Standard Details with the following modifications and additional requirements. Concrete for valley gutter shall conform to the requirements of Section 73 of the Standard Specifications and as specified herein. All soft or spongy material shall be removed and replaced with suitable material as required by the Engineer. Construction Specifications -181 Volume 3 for Public Improvements Revised October 2010 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Construction Specifications -181 Volume 3 for Public Improvements Revised October 2010 � ''--r----------_r-----��---"----"---- Construction Specifications for Public Improvements Volume 3 Revised $gplgflibgf:299TJanuary-2006-July-2-OWOctober 2010 Eng4wexn � ''--r----------_r-----��---"----"---- Construction Specifications for Public Improvements Volume 3 Revised $gplgflibgf:299TJanuary-2006-July-2-OWOctober 2010 Construction Specifications for Public Improvements Volume 3 Revised $gplgflibgf:299TJanuary-2006-July-2-OWOctober 2010 SECTION 76 — CONCRETE CYLINDER PIPE 76 -1.01 General Concrete Cylinder Pipe or Reinforced Mortar Pressure Pipe shall meet the requirements of Section 76 as specified herein. If Concrete Cylinder Pipe is selected, it shall conform to the requirements specified in this section and cathodic protection shall be provided as specified in herein. 76 -1.02 Description Mortar lined and coated steel cylinder pipe shall be pretensioned concrete cylinder type in accordance with AWWA C303 and as noted herein. Piping shall be per AWWA C303 for piping inclusive of 60 -inch diameter, unless otherwise noted. Pretensioned concrete cylinder pipe shall conform to AWWA C303 and its appendix except as follows. All piping and appurtenances shall be designed for 100 psi working pressure minimum and shall be capable of withstanding a trench load of 20 feet. Rubber gaskets shall conform to Section 76 -1.02 (4), "Flanges, Gaskets, and Bolts ", as specified herein. Buttering material for sealing interior joints and grout for exterior sealing of joints shall conform to mortar specified in section 3.10 of AWWA C303. Piping shall be designed in accordance with the appendix of AWWA C303. Pipe diameter referred to is inside diameter of pipe after installation of pipe lining. Piping 48 inch diameter and larger shall be designed to limit deflection. When this type of pipe is used for 48 -inch diameter and larger pipe, the Contractor shall assume complete responsibility for proper installation to prevent deflections in excess of the limits specified in Section 76 -1.07, "Laying Concrete Cylinder Pipe ", Part 50, "Pipe Deflection ", as specified herein. 1. Materials. Cement shall be portland cement in accordance with ASTM C150 and shall be Type II. Steel cylinders shall be ASTM A570 structural quality Grade C and shall be 10 gauge minimum. Steel for joint rings shall conform to ASTM A570 Grade A and shall be minimum 12 gauge for diameters up to 18 inches, minimum 3/16 inch for diameters 18 through 42 inches and 1/4 inch for diameters 48 inches and larger. Spigot rings shall be formed from hot rolled steel having Carnegie Shape M3516. 2. Construction. Reinforcing bars shall be wound helically around the cylinder under a tensile stress in accordance with AWWA C303. A device shall be provided for stressing, measuring, and indicating the tension of the bar reinforcement during the winding operation. As the circumferential bar reinforcement is wound, a portland cement paste composed of one sack of cement to not more than five gallons of water shall be applied to the Construction Specifications -183 Volume 3 for Public Improvements Revised October 2010 rod or to the cylinder in such a manner that the section of bar bearing on the cylinder shall be coated with cement paste. Immediately preceding application of concrete encasement, a cement paste composed of one sack of portland cement to not more than five gallons of water shall be applied uniformly over the steel surface. 3. Data Required. The manufacturer shall provide the following data in addition to the other requirements herein: an affidavit of compliance; design calculations; steel test reports; concrete test reports; rubber gasket test reports; and the pipe laying diagram. The pipe shall be marked in accordance with AWWA C303. 4. Flanges,, Gaskets, and Bolts. Steel pipe flanges whose nominal diameter is 6 inches or greater shall conform to AWWA Standard C207, Class D. All flanges shall be furnished with gaskets, studs, or bolts and nuts. Where a flange is not connected to another appurtenance or pipe, a blind flange shall be attached. Gaskets for flanges shall be 1/16 -inch thick, rubber or asbestos composition. The gaskets shall conform to ASTM Designation F104 (112100 -M6). Unless otherwise specified, all bolts, studs, and nuts shall be steel conforming to the requirements of ASTM Designations A307, A325, or approved equal. Washers shall be of forged or rolled steel. All bolting material shall be cadmium plated. Unless otherwise specified, steel bolts shall be furnished with regular semifinished hexagonal heads and nuts. Bolt heads and nuts shall be sufficient to break the bolt in the body portion when tested. 5. Protective Coatings for Appurtenances. This section covers the preparation of surfaces and the application of protective coatings and related materials as required to complete the work as specified herein. Galvanized metal, non - ferrous metal parts, stainless steel parts, austenitic gray iron, and high nickel cast iron parts shall not be coated unless otherwise specified in these specifications. Surfaces not to be coated shall be protected from contamination and damage during the cleaning and coating of adjacent surfaces. The items listed in the following schedule shall be shop- coated, unless otherwise specified. Field coating may be permitted on items not specified herein upon approval of the Engineer. Coating materials, minimum number of coats, and minimum dry film thickness for the various items of work shall be as specified below, unless otherwise shown on the drawings. Surface preparation and undercoat(s) shall be in accordance with the coating manufacturer's recommendations. Construction Specifications -184 Volume 3 for Public Improvements Revised October 2010 6. Marking of Pipes. Each pipe section and special fitting shall be marked clearly on the interior surface with the manufacturer's name or trademark and the date of manufacture. In addition, special marks of identification, sufficient to show the proper location of the pipe or special fitting in the line, shall be placed on each pipe or special. Each pipe shall be marked with a designation, e.g. 48 PT 100. The first number denotes pipe inside diameter in inches; "PT" denotes pretensioned pipe; and the last number denotes the operating head in psi, as specified herein. The pipe coating shall be marked with the date the coating was applied. ITEM COATING A. All bolts, nuts, and washers. Cadmium plated in accordance with ASTM - - Designation A 165. - - Exterior surfaces of burled blend Two coats, 8 mils each, Kopper's Bitumastic 300 B. flanges. M coat -tar epoxy or ENGARD 800 coal tar epoxy - - - - - - or approved equal. C Interior ferrous surfaces of blind „ Same as Item "B". . flanges and valves. D. All surfaces of buried valves. Same as Item "B ". Exterior surfaces of pipe ends to „. Same as Item "B"; extend for all sleeve -type E. coal -tar enamel coating and couplings. wrapping. Exterior surfaces of nuts and One coat, 8 mils, of bolts for flanged joints, F. sleeve -type couplings, and blend Kopper Bltumastic 300 Mcoal -tar epoxy or flanges. Engard to be applied after installation and hand tool cleaning. Compensation for furnishing and application of protective coatings will be deemed included in the contract prices for the various items of work and no additional payment will be made therefore. 6. Marking of Pipes. Each pipe section and special fitting shall be marked clearly on the interior surface with the manufacturer's name or trademark and the date of manufacture. In addition, special marks of identification, sufficient to show the proper location of the pipe or special fitting in the line, shall be placed on each pipe or special. Each pipe shall be marked with a designation, e.g. 48 PT 100. The first number denotes pipe inside diameter in inches; "PT" denotes pretensioned pipe; and the last number denotes the operating head in psi, as specified herein. The pipe coating shall be marked with the date the coating was applied. Construction Specifications -185 Volume 3 for Public Improvements Revised October 2010 - - - - - - - - - - - - - - - - - - - - - - Construction Specifications -185 Volume 3 for Public Improvements Revised October 2010 76 -1.07 Laying Concrete Cylinder Pipe 1. Alignment, Angles, and Bends. In general, the centerline of the pipe shall be as shown on the Plans. When necessary, and with the approval of the Engineer, the pipeline may deviate slightly from this alignment. Changes in the direction of alignment or grade of the pipeline shall be accomplished by using specially fabricated bends, by beveling the ends of the pipe, or by pulling the joints. It is desirable to eliminate special sections or fittings wherever possible and the Contractor may submit alternate curves for approval by the Engineer. Wherever a grade break is shown on the drawings at a specific station, it is permissible to alter said station so that the change in grade is more gradual and can be taken up in the joints without exceeding the allowable angle of deflection recommended by the pipe manufacturer. In general, the Contractor shall hold the flow line of the pipe at or below the specific elevation denoted on the profile. When necessary, and with the approval of the Engineer, the pipeline may deviate slightly from this profile; however, in no case shall the top of the pipe have less than the cover indicated on the typical trench details shown on the Plans. Beveling pipe ends to provide for angles in the pipeline, where fittings or specials are not used, shall be accomplished by cutting the pipe sections to the proper length and beveling one or both ends of each pipe section by welding the bell or spigot ring to the pipe cylinder at a deflection of no more than five degrees from the plane perpendicular to the longitudinal axis of the pipe section. Pulled joints will be permitted at beveled pipe ends. 2. Joints and Couplings. Field joints may be either welded or rubbergasketed type, except where specifically shown on the Plans and where welding is necessary to anchor pipe in tension. Where the words "weld joints" are shown on the profile sheets, the Contractor is required to weld the joint. The weld may be on the inside or outside. The Contractor shall weld all vertical and horizontal joints which deflect more than five degrees. The length of pipe to be welded shall be as shown on the Plans. Construction Specifications -186 Volume 3 for Public Improvements Revised October 2010 All field- welded joints shall conform to the requirements of AWWA Standard C206 as modified herein. Bell and spigot joints shall be double - welded (an inside and outside weld) at concrete encasements and in casings under highways and railroads. Prior to backfilling this type of joint, the Contractor shall test the joint in accordance with AWWA Standard C206, Section A8 -2, paragraph 2.2, or by soap or wash pass test. Where flanged coupling adapters are specifically called for on the drawings, the coupling shall be harnessed against tension in accordance with AWWA Manual M -11 design details. Where there will be no tension across a joint and the Contractor uses a flexible coupling, at his option, the harness may be omitted. The outside of pipe cylinders to be fitted with flexible couplings shall be free from surface defects and shall have the longitudinal or spiral welds ground to plate or sheet surface for a distance of 10 inches back from the pipe ends. Pipe cylinders shall have tolerances within the limits required by the manufacturer of the coupling to be used. 3. Pipeline Anchorage. The Contractor shall provide such anchorage for the pipeline, fittings, and appurtenance structures as may be required to adequately resist 150% of the pipeline working pressures specified herein. Anchorage for the pipe against longitudinal thrust, when the bend is greater than 5 degrees, shall be provided by Portland Cement Concrete thrust blocks or by welding for the required distances on each side of the vertical or horizontal bends, as shown on the Plans. The length of welded joints each side of a mainline valve shall be the same as for a 90 degree deflection as shown on the Plans. Field- welded joints shall be as specified in Section 76 -1.07 as specified herein. The City retains the right to inspect any and all welds. Any welds found to be unacceptable shall be rewelded and retested. The Contractor will be responsible for the cost of any retesting of welds. All welds shall be sandblasted prior to grouting of the joints. In lieu of welding the pipe, Portland Cement Concrete thrust blocks shall be required at bends, tees, and reducers. The concrete thrust blocking shall be as shown on the Detail Sheet provided in these specifications. 4. Pipe Cleaning and Leakage Test. The Contractor, after placement of the pipe, shall remove all construction materials and shall sweep or otherwise clean the pipe of all dirt and debris. After the backfill has been completed, the pipeline and valves shall be tested for water - tightness by filling it with water and bringing the hydrostatic pressure to not less than 25 percent and not more than 50 percent in excess of the "working pressure ". "Working pressure" for the pipeline shall be 100 psi minimum. Construction Specifications -187 Volume 3 for Public Improvements Revised October 2010 The Contractor shall furnish necessary bulkheads, pumps, pressure gages, means of measuring water loss, water, and all other equipment, materials, and labor required for making the test. The line shall be isolated for testing by placing temporary bulkheads in the pipe. The Contractor shall contact the Public Works Department (707) 588 -3300 for information regarding allowable uses of City water and available sources of water, other than the City water system, for construction purposes. The amount of water required to maintain the test pressure shall be measured accurately by means approved by the Engineer. While the pipe is under pressure, a survey shall be made by the Contractor along the pipeline for leaks. Regardless of the test results, all detectable leaks shall be repaired by the Contractor and the pipeline retested so that the remaining amount of leakage can be determined. If the leakage rate exceeds that specified, the repair and retest procedure shall be repeated until the pipeline passes the leakage test. For the pipeline to satisfactorily pass the leakage test, the measured leakage under the test shall not exceed 40 U.S. gallons per inch of inside diameter per 24 hours per mile of pipe. 5. Pipe Deflection. Vertical ring deflection in pipe after backfill shall not exceed the following limits: 2 Pretensioned Steel Cylinder Concrete Pipe is (D ) inches. 4000 Where "D" is nominal pipe diameter In inches. If deflections are found to be in excess of the above, the pipe shall be uncovered and allowed to reround, and the bedding and backfill shall be re- compacted. If the pipe lining or coating is damaged or if the pipe does not reround to less than the above limits, it shall be replaced at the Contractor's expense. 6. Bedding. Pipe bedding shall conform to City Std. 215. 7. Dewatering. The Contractor shall perform all dewatering and maintain temporary drainage as required to keep the excavation free of water through the construction operations. Wherever necessary for dewatering or to provide proper drainage, the Contractor shall, at his own expense, furnish and operate all necessary pumping equipment, drainage sumps, well point system, and other drainage facilities. 8. Warning _ Tape. After bedding is completed and before backfilling begins, the Contractor shall furnish and install underground line warning ribbon or tape, one foot Construction Specifications -188 Volume 3 for Public Improvements Revised October 2010 above the pipeline. The tape shall be made of high-quality polyethylene base material that will resist acids, alkalis, and other substances normally found in soils. The tape shall have a thickness of at least .004 -inch and have a width of at least 6 inches. The tape shall be color -coded (nonfading bright green) with overcoating printing which reads continuously: "CAUTION CAUTION" "RECLAIMED IRRIGATION WATER" The tape shall be Brady Identoline or approved equal. The cost of furnishing and installing this tape shall be considered as included in the contract price for the appropriate pipe item. Construction Specifications -189 Volume 3 for Public Improvements Revised October 2010 _4 n � rn � rACr o�Arcr Ain Construction Specifications -189 Volume 3 for Public Improvements Revised October 2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Construction Specifications -189 Volume 3 for Public Improvements Revised October 2010 SECTION 77 — PIPE CASING 77 -1.01 Description Pipe casing shall conform to the requirements of the Plans, Sections 65 and 66 of the Standard Specifications and as specified herein. The method of installing the casing shall be at the Contractor's option. The casing may be either 5/8" thick corrugated galvanized steel liner plate, 5/8" thick steel pipe, or reinforced concrete pipe, Class III minimum. The casing shall be of sufficient strength to withstand surface loads imposed by E80 railroad loads under the railroad area and H2O highway loads under the highway area and must also be of sufficient strength to withstand all additional construction loads. Method of installation and materials to be used shall be submitted to the Engineer for approval. If corrugated steel liner plate or steel pipe is used, the liner or the pipe shall be galvanized and bituminous lined and coated. Bituminous coating shall be either field applied or furnished by the manufacturer and shall conform to the following specification. Coating may be either asphalt mastic or tar base. Corrugated steel liner plate or steel pipe shall be galvanized in accordance with ASTM A -123- 71. Bolts, nuts, and pipe plugs shall be galvanized in accordance with ASTM A- 153 -67. Bituminous coating shall be as per AASHTO Designation M243 -73 Asphaltic Mastic or Tar Base. All galvanized surfaces shall be coated. The excavated hole shall be as per AASHTO Designation M243 -73 of one part Type II Portland Cement and two parts sand conforming to ASTM C33 and graded so that 100% by weight will pass a standard No. 8 mesh sieve, and at least 48% by weight will pass a standard No. 40 mesh sieve, and the minimum amount of water required for mixing and placing. Sluicing and jetting with water will not be permitted. Construction Specifications -190 Volume 3 for Public Improvements Revised October 2010 - - - - - - - - - - - Construction Specifications -190 Volume 3 for Public Improvements Revised October 2010 SECTION 78 — REINFORCED PLASTIC MORTAR PRESSURE PIPE 78 -1.01 General Reinforced Plastic Morter Pressure Pipe shall only be used with the permission of the City EqgLneer- Concrete Cylinder Pipe or Reinforced Plastic Mortar Pressure Pipe shall conform to the requirements of the Standard Specifications and as specified herein. If Reinforced Plastic Mortar Pressure Pipe is selected, it shall conform to the requirements specified in this section and cathodic protection shall not be required, except for the "Pipe Casing" specified in Section 77 if corrugated steel liner plate or steel pipe is used. 78 -1.02 Description Reinforced Plastic Mortar Pressure Pipe shall be manufactured in accordance with ASTM D- 3517 and as specified herein. All piping and appurtenances shall be designed for 100 psi working pressure minimum and shall be capable of withstanding a trench load of 20 feet. All Reinforced Plastic Mortar Pressure Pipe shall be designed to limit deflection. When this type of pipe is used, the Contractor shall assume complete responsibility for proper installation to prevent deflections in excess of the manufacturer's recommendations. 1) Data Required: The manufacturer shall provide the following data in addition to the other requirements herein: an affidavit of compliance; design calculations; test reports on pipe and joints; pipe laying diagram; and five copies of the manufacturer's installation guide. 2) Marking of Pipes: Each pipe section and special fittings shall be marked clearly on interior surface with the manufacturer's name or trademark and the date of manufacture. Pipe markings shall be in accordance with ASTM D-3517. In addition, special marks of identification, sufficient to show the proper location of the pipe or special in the line, shall be placed on each pipe or special. Construction Specifications -191 Volume 3 for Public Improvements Revised October 2010 ili'llllllllll - - 0 - - - - - - - - - - - - - - - - Construction Specifications -191 Volume 3 for Public Improvements Revised October 2010 . II II II II 78 -1.04 Laying Reinforced Plastic Mortar Pressure Pipe 1) Alignment, Angles, and Bends: Laying of reinforced Plastic Mortar Pressure Pipe shall be as specified in Section 76 -1.07, "Laying Concrete Cylinder Pipe ", Part 1, except that the last paragraph is not applicable. 2) Joints, Couplings, and Adapters: Joints shall be as specified in ASTM D -3517. Couplings and adapters shall be as recommended by the manufacturer. 3) Pipeline Anchorage: The Contractor shall provide such anchorage for the pipeline, fittings, and appurtenance structures as may be required to adequately resist 150% of the pipeline working pressures specified herein. Portland Cement: Concrete thrust blocks shall be required at bends, tees, and reducers. The concrete thrust blocking shall be as shown on the detail sheet provided in these specifications. 4) Pipe Cleaning and Leakage Test: The Contractor, after placement of the pipe, shall remove all construction materials and shall sweep or otherwise clean the pipe of all dirt and debris. After the backfill has been completed, the pipeline and valves shall be tested for watertightness by filling it with water and bringing the hydrostatic pressure to not less than 25 percent and not more than 50 percent in excess of the "working pressure ". "Working pressure" for the pipeline shall be 100 psi minimum. The Contractor shall furnish necessary bulkheads, pumps, pressure gages, means of measuring water loss, water, and all other equipment, materials, and labor required for making the test. The line shall be isolated for testing by placing temporary bulkheads in the pipe. The Contractor shall contact the Public Works Department at (707) 588-3300, for information regarding allowable uses of City water and available sources of water, other than the City water system, for construction purposes. The amount of water required to maintain the test pressure shall be measured accurately by means approved by the Engineer. While the pipe is under pressure, a survey shall be made by the Contractor along the pipeline for leaks. Regardless of the test results, all detectable leaks shall be repaired by the Contractor and the pipeline retested so that the remaining amount of leakage can be determined. If the leakage rate exceeds that specified, the repair and retest procedure shall be repeated until the pipeline passes the leakage test. For the pipeline to satisfactorily pass the leakage test, the measured leakage under the test shall not exceed 40 U.S. gallons per inch of inside diameter per 24 hours per mile of pipe. Construction Specifications -192 Volume 3 for Public Improvements Revised October 2010 5) Beddin : Pipe bedding shall conform to City Std. 215 except that pipe bedding material shall be 4 sack Portland Cement concrete with aggregate graded as follows: 100% passing 3/4 ", 30% to 70 % passing #4, and 0% to 10% passing a No. 200. 6) Dewatering: Dewatering shall be as specified in Section 76 -1.07, "Laying Concrete Cylinder Pipe ", Part 7. 7) Warning Tape: Warning tape shall be as specified in Section 76 -1.07, "Laying Concrete Cylinder Pipe ", Part 8. Construction Specifications -193 Volume 3 for Public Improvements Revised October 2010 � rn o�Arcr Ain Construction Specifications -193 Volume 3 for Public Improvements Revised October 2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Construction Specifications -193 Volume 3 for Public Improvements Revised October 2010 SECTION 79 — VIDEO INSPECTION OF STORM DRAINS 79 -1.01 Description Television inspection of all new and modified storm drain pipes and structures is required. The contractor shall hire an independent pipe video inspection service to perform the inspection. The camera used shall be self - propelled or pulled, be able to pan and tilt and shall be equipped with high - intensity lights. A •digital video on CD-erDVD in an acceptable format of the television inspection shall be produced along with a printed log of the inspection and delivered to the Engineer. The pipe video inspection service shall be pre - approved by the City. The pan and tilt color camera used for the inspection shall be specifically designed and constructed for such inspection. The camera shall be mounted on adjustable skids or tractor to keep it in the center of the pipe. Lighting for the camera shall be supplied by a lamp(s) on the camera, capable of being dimmed or brightened remotely from the control panel. The lighting system shall be capable of illuminating the entire periphery of the pipe. The color camera shall be operative in 100% humidity conditions and shall have a minimum of 330 lines of resolution but must be capable of discerning small, hairline cracks and other minor defects. The pan and tilt color camera shall be moved through the line at a uniform slow rate of 30 feet per minute maximum. A 2- inch depth gauge shall be pulled or pushed in front of the camera. All pipe cleaning prior to the video inspection will be at the contractor's expense. All cleaning water and debris shall be captured, removed and properly disposed. Cleaning water will not be allowed to discharge to the storm drain system. The contractor is responsible for all stuck, broken or lost equipment and shall bear all necessary cost to retrieve said equipment including dig ups. All work performed must meet quality and clarity standards set by the City of Rohnert Park and are subject to Public Works review. A pan and tilt color camera will be used for all video inspections of storm drains within the jurisdiction of the City of Rohnert Park. The following conditions shall exist prior to the television inspection: • All storm drain pipes shall be installed, grouted, backf lied to 5 feet over the top of the pipe or to subgrade, and compacted; Conduits or pipelines for all underground utilities (sewer, water, cable television, telephone, electrical, gas, street light) that cross storm drain trench shall be installed; The bases of all structures shall be in place and grouted; Construction Specifications -194 Volume 3 for Public Improvements Revised October 2010 The system shall be cleaned and all debris removed; Street shall be unpaved; When the above work has been completed, the contractor shall notify the Engineer 48 hours in advance of the date for television inspection. Immediately before inspection the system shall be flushed with clean water. During this inspection, the contractor or authorized representative shall be present to observe the video as provided by the television camera. At the beginning of each run of storm drain pipe the video shall display: A. The project name; B. Date; C. Company performing the inspection; D. Run number (unique designation for each section of pipe); E. Street name (if applicable); F. Pipe size; G. Pipe material; H. Structure numbers (as labeled on the plans) at each end of the pipe; I. Direction of the camera; J. Type of structure. The video tape shall display the following information continuously during the run: A. The camera's location via a continuously updated footage counter measuring the distance from point of entry; B. Project name; C. Structure numbers (as shown on the plans) at each end of the run; D. Run number. The camera shall stop at all structures, connections or defects (sags, bad joints, etc.) for a period of at least 10 seconds and be noted on the log sheet. The camera will be panned or tilted toward the connection or defect so that any portion of the connection or defect that is visible from within the pipe or structure can be completely inspected. A printed record shall be made for each pipe run and shall clearly show the: A. Run number; B. Structure number at each end of the run; C. Direction of camera travel; D. Location and description of each defect discovered by the camera; E. Line size; F. Length of run; G. Structure depths; H. Location of blind connections. Construction Specifications -195 Volume 3 for Public Improvements Revised October 2010 The video inspection disk or tape and report shall be delivered together to the Engineer and become the property of the City of Rohnert Park. The following video tape observations shall be considered defects in the construction of the storm drain system and will require corrections prior to acceptance: Off grade - 0.08' or more deviation from grade; Joint separations; Offset joints; • Cracked or damaged pipe or evidence of the presence of an external object bearing upon the pipe (rock, root, etc.); Debris or other foreign objects; Pipe deflections greater than 7.5% of base diameter, measured inside the pipe; • Other obvious deficiencies when compared to approved Plans and Specifications, these Standards and City Design and Construction Standards. The contractor will be notified in writing of any deficiencies revealed by the television inspection that will require repair, following which the contractor shall excavate and make the necessary repairs and request a television re- inspection. Television re- inspection shall be at the contractor's expense. Any subsequent televising of the lines, if deemed necessary by the City, shall be completed at the City's expense. Any defects found prior to or during the warranty period shall be corrected by the contractor. Construction Specifications -196 Volume 3 for Public Improvements Revised October 2010 Construction Specifications for Public Improvements Volume 3 Revised October 2010 . hereim. Construction Specifications for Public Improvements Volume 3 Revised October 2010 SECTION 80 — CHAIN LINK FENCE CONSTRUCTION 80 -1.01 Description The chain link fence, gates, and appurtenances to be erected under this contract shall be constructed in accordance with Section 80 of the Standard Specifications, the details shown on the Plans, as specified herein, and as directed by the Engineer. The fence and gates shall consist of six foot high steel mesh fabric with a top rail and topped by three strands of barbed wire equally spaced six inches apart on angled extension arms for a total fence height of approximately seven feet. 80 -1.02 Connections Existing cross fences shall be connected to the new fences. Corner posts with braces for every direction of strain shall be placed at the junction with existing fences. The wire in the new and existing fences shall be fastened to the posts. 80 -1.03 Materials Fabric: Chain link fence fabric shall be galvanized steel fabric conforming to the specifications of AAFHP Designation M -181. The fabric shall be #9 gauge, 72" high, and woven into approximately a two inch mesh. All chain link fabric shall be galvanized after weaving by the hot dip process with a minimum of 1.2 ounces of zinc retained per square foot of uncoated wire service. Posts and Framework: All posts, gate frames, and top rails shall be steel pipe galvanized according to the specifications of AASHO Designation M -111 and shall conform to the following dimensions and weights: O.D. Min. Wt. Per L.F. Line Posts 01A Terminal and Corner Posts 21/2" Gate Posts 4" Top Rails Gate Frames 1-5/811 1-5/811 2.72 3.65 9.11 2.27 2.27 Line post spacing shall not exceed ten foot centers. All line and corner posts shall be a minimum of nine feet in length and gate posts a minimum of ten feet in length. Braces: All terminal and corner posts shall be truss braced from a first line post to the bottom of the terminal post with a 3/8" galvanized truss rod assembly. Gates: Two 8 -foot drive gates providing a 16 -foot wide clear opening shall be provided and installed where shown on the Plans and as directed by the Engineer. Gates shall be provided with Construction Specifications -199 Volume 3 for Public Improvements Revised October 2010 catch and locking attachment of an approved design which will not rotate around the latch post. Stops to hold gates open and a center rest with catch shall be provided. Gate hinges shall provide a 90 degree opening. All fittings shall be hot dip galvanized. 80 -1.04 Erection The fence shall be installed by skilled and experienced fence erectors on lines and grades furnished by the Engineer. Line and corner posts shall be set in concrete foundations a minimum of 36" inches deep and gate posts a minimum of 48" deep. Concrete foundations shall be no less than three times the diameter of the posts. Offm - - - -- - - - -- - 110-1-INI-Milm, M- - - - - - - - - - - - - - - - - - - - - - - - - - - Construction Specifications 1100 Volume 3 for Public Improvements Revised October 2010 SECTION 80 -5 — REDWOOD FENCE 80 -5.01 Description Redwood fencing shall be constructed in accordance with the details shown on the Plans as specified herein and as directed by the Engineer. 80 -5.02 Materials Fencing materials shall consist of the following: 4 "x4" Posts g 6'0" O.C. 2"x4" Running Rails, Top and Bottom 1 11x6" or 1 "x8" Fence Boards (5') All fencing material shall be standard, rough -sawn redwood. 80 -5.03 Gates The existing gates shall be relocated as shown on the Plans and as directed by the Engineer. Gates shall be rehung from 4 "x4" redwood posts. Construction Specifications 1101 Volume 3 for Public Improvements Revised October 2010 SECTION 81— MONUMENTS 81 -1.01 Description All City monuments shown on the Plans shall be placed in accordance with the requirements of Section 81 of the Standard Specifications and as specified herein. The exact location of the monuments will be established by the Engineer as shown on subdivision map and upon completion, the monuments will be checked and the center point stamped by the Contractor's /Developer's Engineer. Construction Specifications 1102 Volume 3 for Public Improvements Revised October 2010 additional-aflowane&mifl-be-made4herefor-e-. Construction Specifications 1102 Volume 3 for Public Improvements Revised October 2010 SECTION 83 — RAILING AND BARRIERS 83 -1.01 Railin The work shall consist of constructing metal tube bridge railing (Type 116) at the locations and in accordance with the details shown on the Plans, and as specified in Section 83 of the Standard Specifications and as specified herein, and as directed by the Engineer. Metal beam guard railing shall conform to the provisions in Section 83 -1, "Railing," of the Standard Specifications and as specified herein. Line posts and blocks shall be wood. When metal beam guard railing is connected to structures, walls or abutments, the structure, wall or abutment will be considered the end post and the point used for measuring the rail length shall be the midpoint between the 2 bolts attaching the rail element to the structure, wall or abutment. The quantities of return and end sections and the various types of terminal sections will be determined as units from actual count. 83 -1.02D Steel Bridte Railing Metal tube bridge railing, metal beam guard railing, terminal end sections and all hardware shall be ASTM A -588 structural steel (USS Cor -10 or Bethlehem MAYARI or equal). Construction Specifications 1103 Volume 3 for Public Improvements Revised October 2010 SECTION 84 — TRAFFIC STRIPES AND PAVEMENT MARKINGS 84 -1.01 Description Traffic stripes and pavement markings shall conform to the applicable provisions of Section 84 of the Standard Specifications, Part IV of the City Traffic Standards, and as specified herein and shall be done at the locations shown on the Plans. Existing stripes and pavement markings which are damaged by the work shall be replaced. Construction Specifications 1104 Volume 3 for Public Improvements Revised October 2010 SECTION 85 — PAVEMENT MARKERS 85 -1.01 Description Raised pavement markers shall be placed in conformance with the details and at the locations shown on the Plans and in accordance with the applicable provisions of Section 85 of the Standard Specifications, as specified herein and Volume L Part IV of the City Traffic Standards. The exact location and limits of raised pavement markers will be determined in the field by the Engineer. Existing raised pavement markers conflicting with the proposed striping shall be removed immediately prior to placement of new markers. Existing raised pavement markers to remain, which are damaged by the Contractor, shall be replaced. Raised pavement markers shall be installed the following pavement overlay. Construction Specifications 1105 Volume 3 for Public Improvements Revised October 2010 - - - - - - - - - - Construction Specifications 1105 Volume 3 for Public Improvements Revised October 2010 SECTION 86 — TRAFFIC SIGNAL DETECTOR LOOPS AND VIDEO DETECTION SYSTEM 86 -1.01 Description The Contractor shall furnish and install traffic signal detector loops or video detection system shown on the Plans in conformance with the applicable provisions of Section 86, "Signals and Lighting ", of the Standard Specifications and Standard Plans, the City Traffic Standards, as specified herein, and as directed by the Engineer. 86 -2.05 Conduit Conduit shall conform to the Standard Specifications and the City Traffic Standards. Trenching depth shall be per Section 86 -2.01 of the Standard Specifications and as specified herein. 86 -2.06 Pull Boxes Pull boxes shall conform to Part V.G of the City Traffic Standards and as specified herein. All existing pull boxes to receive new conductors and /or conduits shall be cleaned out, all existing grout removed, and the bottoms regrouted with a drain hole or the boxes replaced to meet current City Traffic Standards. 86 -2.08 Conductors All conductors for traffic signal or street lighting systems shall conform to Section 86 of the Standard Specifications, Part V.H of the City Traffic Standards, as shown on the Plans, or as spe- cified herein. 86 -2.09 Wirin Wiring shall conform to the Standard Specifications and Part V.I of the City Traffic Standards. 86 -2.14C Functional Testing The functional test for each traffic signal detector loops or video detection system shall consist of not less than 48 hours of continuous, satisfactory operation. If unsatisfactory performance of the system develops, the conditions shall be corrected and the test shall be repeated until the 48 hours of continuous, satisfactory operation is obtained. Construction Specifications 1106 Volume 3 for Public Improvements Revised October 2010 86 -5 Detectors 86 -5.01A Inductive Loop Detectors Inductive loop detectors shall conform to Sections V -J and V -K of the City Traffic Standards. Detector handholes shall be Type A installed per State Std. ES -5E. Any existing traffic signal detectors shown on the Plans to remain that are damaged shall be replaced at the Contractor's expense within five (5) working days or as directed by the Engineer. Construction Specifications 1107 Volume 3 for Public Improvements Revised October 2010 IN - - - - - - - - - - Construction Specifications 1107 Volume 3 for Public Improvements Revised October 2010 SECTION 90 - PORTLAND CEMENT CONCRETE 90 -1.01 Description Class A concrete shall be truck- mixed, ready -mixed concrete consisting of a mixture of Type II Portland Cement complying with ASTM C150, sand, fine aggregate, coarse aggregate, and water. The proportions of the water, sand, and aggregate shall be regulated so as to produce a plastic, workable, and cohesive mixture. All materials required, and the procedure of mixing, shall conform to the provisions of Section 90 of State Standard Specifications. Class A concrete shall contain 564 pounds (six sacks) of Portland Cement per cubic yard and shall have a 28 -day compressive strength of 4000 pounds per square inch. 90 -1.03 Steel Reinforcement Reinforcing bars, where required, shall be deformed billet steel in conformance with ASTM A615, including supplementary requirements, Grade 60. Wire fabric, where required, shall be welded steel mesh conforming to ASTM A185. 90 -1.04 Mix Designs Reports of concrete mix designs shall be provided for review by the Engineer. 90 -1.05 Placement and Curing Placement, consolidation, and curing of concrete shall conform to the provisions of Section 90 of State Standard Specifications. Construction Specifications 1108 Volume 3 for Public Improvements Revised October 2010 SECTION 98 — HANDICAP RAMP CONSTRUCTION 98 -1.05 Curb, Curb and Gutter, and Sidewalk Removal and Construction Portland cement concrete curb, curb and gutter, and sidewalk shall be removed and constructed in conformance with the details and at the locations shown on the Plans and in accordance with the applicable provisions of Section 73 of the Standard Specifications and as specified herein. All oil, paint, tire marks, and other discoloring shall be removed from the curb and gutter by sandblasting prior to acceptance by the Engineer. Cement mortar will not be an acceptable substitute for sandblasting. All soft or spongy material shall be removed and replaced with suitable material as required by the Engineer. 98 -1.06 Pull Box Relocation Existing pull boxes that are within the area of handicap ramp construction shall be reset to grade as directed by the Engineer. 98 -1.07 Sisn Relocation Street and traffic signs that conflict with the construction and /or use of the handicap ramp shall be relocated as directed by the Engineer. Construction Specifications 1109 Volume 3 for Public Improvements Revised October 2010 > > planejoint > > Construction Specifications 1109 Volume 3 for Public Improvements Revised October 2010 Construction Specifications for Public Improvements 4-110 Volume 3 Revised October 2010 SECTION 99 — WATER MAIN CONSTRUCTION 99 -1.01 Description All water mains and related appurtenances shall be constructed in accordance with the City of Rohnert Park Standard Details and Specifications, the Standard Specifications for Public Works Construction "Greenbook" and the Plans. 99 -1.02 P The pipe, except where otherwise specified on the Plans, can be either ductile cast iron or polyvinyl chloride (PVC), all in accordance with the following: A. Ductile iron pipe shall be cement lined, new pipe conforming to ANSI-A-24-.-51 49-76AWWA C 151 or most recent issue, if any, as sponsored by the American Water Works Association for thickness Class 50 ductile iron pipe. The pipe shall be furnished with either bell and spigot end, "Tyton Joints" or mechanical joints except where otherwise specified on the Plans. B. Polyvinyl chloride (PVC) pipe shall be new pipe, minimum Class 150, or as shown on the Plans and conforming to the requirements of AWWA C900 "Standard for Polyvinyl Chloride Pressure Pipe, 4 inch through 12 inch for Water" and shall be furnished with either bell ends or couplings designed to effect an elastomeric pressure seal. C. Each and every length of pipe and coupling shall be marked with the manufacturer's name, lot number, and the date the pipe was tested. The pipe shall be tested in accordance with the most recent American Water Works Standard Specifications and amendments thereto for the pipe furnished. The testing shall be performed in a State licensed materials testing laboratory where the testing standards meet or exceed State of California testing standards. Accompanying or preceding each load of pipe delivered, a certificate shall be furnished to the City certifying that the pipe which is (to be) delivered has been tested and meets the requirements of the American Water Works Association Standard Specifications. The certificate shall identify the pipe by manufacturer's name, lot number, and date tested by a State certified materials testing laboratory. 99 -1.03 Polyethylene Water Service Tubing All polyethylene water service tubing shall conform to the latest AWWA Standards as described in ANSI /AWWA of the latest revision for 3/4 -inch and 1 -inch tubing. 99 -1.04 Fittin s All fittings shall be new gray iron or ductile iron fittings conforming to ANSI /AWWA C 110 /C 153 of latest revision and shall have the proper type of ends to match the type of pipe used. Gray iron fittings shall be coated inside and outside with a petroleum asphaltic coating conforming to AWWA C 110 and shall meet or exceed the pressure rating of the pipe to be installed. Ductile iron fittings shall be cement mortar lined in accordance with AWWA C 104 of latest revision and shall have a petroleum asphaltic coating conforming to AWWA C 110. Ductile iron fittings shall have a minimum pressure rating of 250 psi and shall otherwise meet or exceed the pressure rating of the pipe to be installed and shall have a minimum Class 53 thickness rating. 99 -1.05 Gate Valves Gate valves shall conform to AWWA Standard C509 of latest revision and shall be the resilient seat type with non - rising stem opening counter - clockwise with O -ring stem seal and suitable ends for connections to type of pipe or fitting used. The working pressure rating of gate valves shall meet or exceed the pressure rating of the pipe specified on the Plans. External bolts and nuts shall be 304 stainless andor poly wrapped per standard. 99 -1.06 Butterfly Valves Butterfly valves shall conform to AWWA Standard C504 of latest revision and shall be of the rubber seat type. Valve discs shall rotate 90 degrees from the full open position to the tight shut position. The valve seat shall provide a tight shutoff at a pressure differential of 150 psi upstream and 0 psi downstream in either direction. The valve operator shall be the traveling nut type. Valve shall open with a counter - clockwise rotation of the operating nut. 99 -1.06A Cut -in Tee and Valve Assembly The Contractor shall cut -in tee and valve assemblies at the location(s) shown on the Plans per City Std. 854 and Std. 877, as directed by the Engineer, as specified herein. 99 -1.06B Air Relief Valve Assembly 99 -1.07 Valve Boxes Each gate valve shall be covered by a precast 8 -inch valve box set flush with street surface with cast iron ring and cover marked "WATER ". The valve boxes are to be Christy G 5, G 8, or approved equal. 99 -1.08 Locating and Adi ustins! Water Valve Boxes After a street has been paved, mark the location of all water valve boxes in white paint before the close of that workday. Within 48 hours of paving, adjust all water valve boxes up to grade. 99 -1.09 Fire Hydrant and Lateral Assembly At the location(s) shown on the Plans, the Contractor shall provide and install a fire hydrant and lateral assembly per City Std. 857. No bends will be allowed in fire hydrant laterals without approval of the r;t T T t l;t;ea Engineering Department. Fire hydrants shall conform to the list of approved fire hydrants shown on City Std. 857. Residential fire hydrants will have one 2-1/2-inch outlet and one 4-1/2-inch outlet. Commercial fire hydrants will have two 2-1/2-inch outlets and one 4-1/2-inch outlet. All hydrants shall be painted in accordance with the specifications shown on City Std. 857. Before a fire hydrant maybe placed in service, a high velocity flushing of the hydrant lateral shall be witnessed and approved by Barrels of existing fire hydrants to be abandoned shall be removed carefully and delivered to the City Corporation Yard at 600 Enterprise Drive per Section 15 -2.04, "Salvage" of the Standard Specifications. 99 -1.10 Asbestos Cement Pipe The installation of asbestos cement pipe is prohibited. All cutting, handling and disposal of asbestos cement pipe shall be done in compliance with the Contractor's State Licensing Law and all applicable laws and regulations. 99 -1.11 Trench Excavation, Backfill, and Resurfacing Excavation, backfill, and resurfacing of the water main trench under this contract shall conform to City Std. 215, as specified on the Plans and as specified herein. Construction Specifications 1113 Volume 3 for Public Improvements Revised October 2010 Excess material from excavation shall become the property of the Contractor and shall be disposed of to the satisfaction of the engineer. Prior to disposal of any materials or operation of any equipment on sites provided by the Contractor for disposal of excess trench excavation owned by him/her, the Contractor shall submit to the engineer written authorization for such disposal of materials and entry permission signed by the owners of the disposal site and the required permits. Attention is directed to Section 7 -1.08, "Public Convenience" of the Standard Specifications. Caution shall be exercised when trenching through signalized intersections. Location(s) of traffic detector loops, as shown on the Plans, is schematic only. If trenching or other construction operations cause damage to any traffic detector loops, the Contractor shall notify the Engineer immediately. Five (5) days prior to cutting any traffic detector loop, the Contractor shall contact the Public Works Department at (707) 588 -3300. The Contractor shall replace the traffic detector loops per City t . 72 2 an City Traffic Standards V.J and V.K, and as directed by the Engineer. Replacement shall be accomplished within two (2) working days of damage, as determined by the Engineer, minimizing interruption of full operation of the traffic signal. Blasting will not be permitted. All raised pavement markers, street striping, chatter bars or any other traffic markings disturbed during this contract work shall be replaced in kind by the Contractor to the satisfaction of the Engineer. 99 -1.11A Trench Bracing and Shoring - Water All bracing and shoring shall conform to Section 5- 1.02A, "Trench Excavation Safety Plans" and Section 7-1.01E, "Trench Safety" of the Standard Specifications and the Division of Industrial Safety Construction Safety Orders which are currently in use. The Contractor shall take all necessary measures to protect the workmen and adjacent areas and structures from the hazards of the trenching or excavation operations. 99 -1.12 Laying and Handling Pipe Materials Proper implements, tools, and facilities satisfactory to the engineer shall be provided and used by the Contractor for safe, convenient and workmanlike prosecution of the work. All pipe fittings and valves shall be carefully lowered into the trench in such a manner as to prevent damage to pipe coatings. Under no circumstances shall pipe or accessories be dropped or dumped into the trench. Before lowering and while suspended, the pipe shall be inspected for defects and the cast iron pipe rung with a light hammer to detect cracks. Any defective, damaged or unsound pipe Construction Specifications 1114 Volume 3 for Public Improvements Revised October 2010 shall be re.ected and sound material furnished. Curing of pipe for inserting valves, fittings, or closure pieces shall be done in a neat and workmanlike manner without damage to pipe. All pipe stockpiled on the job shall be stored with the ends covered to prevent the entrance of foreign matter. Whenever it is necessary either in vertical or horizontal plane, to avoid obstructions or when long radius curves are permitted, the amount of deflection shall not exceed the maximum recommended by the pipe manufacturer or that required for satisfactory jointing. Each length of pipe shall be free of any visible evidence of contamination, dire, and foreign material before it is lowered into its position in the trench, and it shall be kept clean by approved means during and after laying. At times when pipe laying is not in progress, the open ends of any pipe which have been laid shall be closed by approved means to prevent the entrance of small animals or foreign material. Trench water shall not be permitted to enter the pipe. Pipe shall be laid in accordance with the Plans, and as specified herein. All pipe stockpiled on the job shall be stored with the ends covered to prevent the entrance of foreign matter. At times when pipe laying is not in progress, the open ends of any pipe which have been laid shall be closed by mechanical plug or other means approved by the Engineer. Excavations shall begin by exposing end(s) of existing main(s) to determine individual lines and grades. New mains shall begin eight (8) feet from and on the same line as the existing main. Minimum depth of cover from finished grade shall be 36 inches for 8 -inch mains, 44 inches for 12 -inch mains and 48 inches for 16 -inch and larger mains or as shown on the Plans. 99 -1.13 Laying PVC Pipe Individual pieces of pipe, valves, and fittings shall be joined by placing the rubber rings on the machined ends of the pipe and pulling the couplings, valves, or fittings in accordance with the manufacturer's recommendations. The rings shall be checked to be sure they are in the proper position after the coupling is in place. Care shall be taken to insure proper seating of the rings, and adapters shall be utilized for connections as required by the manufacturer. Fittings for PVC pipe shall be either the mechanical joint type or push -on type. PVC pipe shall be as specified in and installed per AWWA C900 of latest revision and in accordance with the manufacturer's recommendations. 99 -1.14 Laying Ductile Iron Pipe The flame cutting of pipe by means of oxyacetylene touch shall not be allowed. Ductile iron pipe shall be as specified in and installed per AWWA C600 of latest revision and in accordance with the manufacturer's recommendations. Construction Specifications 1115 Volume 3 for Public Improvements Revised October 2010 99 -1.15 Service Laterals Service laterals other than those shown or noted on the Plans shall not be installed prior to obtaining City approval. Service laterals encountered in construction that will not be used shall be abandoned. 99 -1.6A Thrust Backing All tees, bends, and plugs shall be provided with thrust backing and /or harness as shown on the Plans or in accordance with City Stds. 851 and 852 and as specified herein. 99 -1.16B Thrust Blocking and /or Restrained Joints Thrust blocking and /or restrained joints shall conform to City Stds. 853 and 854 and as specified herein. 99 -1.17 Abandoning Water System Components For all abandoned water services up to and including 2 -inch, remove the valve and saddle and install a full circle clamp on main under Public Works Department inspection. For flanged or mechanical joint tees, remove the valve and install a blind flange or mechanical joint plug under Public Works Department inspection. For push -on tees, the tee, valve and concrete thrust block must be removed and the main repaired with approved pipe and suitable couplings. 99 -1.18 Hydrostatic Test Construction Specifications 1116 Volume 3 for Public Improvements Revised October 2010 Suitable means shall be provided by the Contractor for determining the quantity of water leakage under the test pressure. No pipe installation will be accepted until or unless this leakage is less than 40 U.S. gallons per 24 hours, per mile of pipe, per inch nominal diameter of pipe. Should any test of combined sections of pipe laid disclose leakage per mile of pipe greater than that water specified, or if individual sections show leakage greater than the specified limit, the Contractor shall, at his /her own expense, locate the cause and repair the defect until the leakage is within the specified allowance. Leakage is defined as the quantity of water to be supplied into the newly laid pipe, or any valved section of it, necessary to maintain the specified leakage test pressure after the pipe has been filled with water and the air expelled. The engineer shall designate the time at which the tests shall be made. The Contractor shall repair any obvious leaks even though the hydrostatic test results are within the prescribed limits above. 99 -1.18A Permanent Blow -Offs Permanent blow - offs) shown on the Plans shall be installed per City Std. 861 and 862, as directed by the Engineer, and as specified herein. Blow -off ball valve and plug shall be installed a minimum of two (2) inches and a maximum of six (6) inches below meter box lid. 99 -1.18B Temporary Blow -Offs Temporary blow - off(s) shown on the Plans shall be installed per City Std. 859, with thrust blocking and harness when required, as directed by the Engineer, and as specified herein. 99 -1.19 Chlorination of Water Main Chlorine may be applied by any of the AWWA standard methods, subject to the approval of the Engineer. The point of application of the chlorination agent shall be at the beginning of the pipe extension, or any valved section of it, and through a corporation stop inserted in the newly laid pipe. Water from the existing distribution system shall be controlled to flow very slowly in the newly laid pipe during the application of chlorine. Precautions shall be taken to prevent back-pressure causing a reversal of flow into the pipe being treated. In the process of chlorinating, all valves and other appurtenances on the new pipe shall be operated in such a way as to provide that the chlorine mixture shall be fully distributed to all parts of the new water system. Valves on existing pipes in service shall be operated only by City forces. The rate of chlorine feed shall be in such proportion to the rate of water entering the pipe that the chlorine dose applied to the water entering the newly laid pipe shall be at least 100 ppm. The chlorine mixture shall be retained in the pipe for a period of twenty -four hours. After the chlorine Construction Specifications 1117 Volume 3 for Public Improvements Revised October 2010 mixture has been retained for the required time, the chlorine residual at the pipe extremities and at representative points shall be at least 5 ppm. There shall be a 24 -hour waiting period after blowing off the main prior to taking bacteria samples. The initial bacteria tests shall be of the 72 -hour duration type. If the initial bacteria test fails, two consecutive passing bacteria tests must be obtained prior to making the tie -in. The first of these two subsequent tests shall be of the 24 -hour duration type, and the second shall be of the 72 -hour duration type. Bacteria tests are valid for only 30 days. If there is more than a 30 -day lapse between a passing bacteria test and the applicable tie -in, the bacteria test must be repeated prior to water main tie -in. Chlorinated water used to disinfect the pipe is the property of the Contractor and its disposal is the responsibility of the Contractor. Chlorinated water used to disinfect the pipe shall be disposed of in accordance with all laws and regulations. The following criteria must be met prior to disposal of chlorinated water to storm sewers or other inland waterways: (1) Water to be disposed of must contain no chlorine residual. (2) pH must be between 6.5 and 7.5. (3) North Coast Regional Water Quality Control Board, at 576 -2220, must be notified of discharge. Discharges not meeting the above criteria may be allowed to be disposed of into the sanitary sewer system, but must first meet the following requirements: (1) The Contractor shall obtain permission from the City of Rohnert Park Public Works Department at (707) 588 -3300 prior to the discharge being disposed of in the sanitary sewer system. The payment of any fees required will be the responsibility of the Contractor. (2) The pH of the water shall be between 6.0 and 9.5. (3) The discharge rate shall be sufficiently slow to keep from surchar ing to sewer collection system at an point. Construction Specifications 1118 Volume 3 for Public Improvements Revised October 2010 Should the initial treatment, in the opinion of the Engineer, prove ineffective, the chlorination procedure shall be repeated until confirmed tests show that the water sampled from the newly laid pipe conforms to the above requirements. The initial bacteria samples will be taken and tests made by the City of Rohnert Park. There shall be a 24 -hour waiting period after blowing off the pipe prior to taking bacteria samples. If the initial bacteria test fails, two consecutive passing bacteria tests must be obtained prior to making the tie -in. The Contractor will pay for additional individual bacteria sample tests. If additional testing is required, it will be necessary for the Contractor to arrange for and to pay for the tests at a State of California certified laboratory. In extreme cases, at the discretion of the Engineer it may be necessary to require, at the Contractor's expense, a complete Title 22 potable water test prior to tie -in. Bacteria tests are valid for 30 days. If there is more than a 30 -day lapse between a bacteria test and the applicable tie -in, the bacteria test must be repeated prior to performing the tie -in. 99 -1.20 Water Main Connection Work The Contractor shall notify the City inspector 48 hours prior to individual mainline shutdowns required to facilitate his tie -in operations. The Contractor shall schedule tie -in work with the Public Works Inspector at (707) 588 -2237. Tie -ins will not be scheduled until a written passing bacteria test has been received by Public Works. All shutdowns and valve turning operations shall be performed by City Water Utility personnel only. A Public Works Department Inspector must be present during all tie -in operations. All shutdowns and valve turning operations shall be performed by City Water Utility personnel only. No tie -ins shall be performed without prior authorization of the Engineer. Pipe and fittings furnished for tie -ins shall be no smaller than the existing water main to which each tie -in is made. Contractors or parties who fail to keep field appointments shall be billed for scheduled Utilities Crew waiting or standby time which was used and the Contractor shall bear the costs incurred by the Utility for re- notification of its customer. As a general rule, customer service shall not be terminated or interrupted on Monday. Interruption of service to commercial customers shall, as much as practical, be coordinated with the customer's needs. The City will contact the customers, consider the customer's interests and inform the Contractor accordingly. After hours work or weekend work is to be avoided whenever possible and any overtime costs shall be borne by the Contractor requesting such nft r-ho ursafterhours work. Normal working hours are Monday through Fridays, 8:00 a.m. to 5:00 .p.m. Construction Specifications 1119 Volume 3 for Public Improvements Revised October 2010 Contractors or parties requiring work of any kind by the City forces shall request such services a minimum of 48 hours in advance of the time such services are desired. Work requests, which will involve City forces for more than 8 hours or an extensive number of City supplied parts, shall be requested a minimum of 7 calendar days in advance. If it is necessary to terminate service to any customer, the Contractor shall make the request for such work an additional 72 hours (three additional working days for a total of five working days advance notice) in advance of the time such services are desired to allow the customers affected to have a minimum of 72 -hour notice. During the work, the Contractor shall exercise all necessary precautions to prevent the entrance of trench water or any other foreign material into the water main and shall conduct all operations in accordance with the most stringent sanitation practices. The interior of all appurtenances being installed shall be thoroughly swabbed with a strong HTH solution prior to installation. Upon completion of construction, final connection will be made by the Contractor under inspection by City Public Works Inspector, unless otherwise specified on the Plans. The Contractor shall notify the City inspector 48 hours prior to individual mainline shutdowns required to facilitate atie -in. The Contractor shall schedule tie -in work with the Public Works Inspector at (707) 588 -2237. Tie -ins will not be scheduled until a written passing bacteria test has been received by Public Works. All shutdowns and valve turning operations shall be performed by City Utilities personnel only. A Public Works Department Inspector must be present during all tie -in operations. No tie -ins shall be performed without prior authorization of the Engineer. Contractors or parties who fail to keep field appointments shall be billed for scheduled City Crew waiting or standby time which was used and the Contractor shall bear the costs incurred by the City for notification of its customers for the subsequent appointment. When installing a cut -in -tee that is larger than the existing pipe, the new assembly must be installed at the depth sufficient to allow the valve to remain below the subgrade of the street which may necessitate lowering the existing pipe. When a connection is required to an existing water pipe, the Contractor shall provide all excavation, shoring, backfill and trench resurfacing per City Std. 215. Where the connection is to be a "hot tap ", the Contractor shall provide and install the tapping valve and sleeve, and any other hardware required and City forces will make the tap at the developer's expense. When any joint on an existing water pipe is disturbed, that joint and any proposed hot tap 4 inch and larger shall be replaced with a "cut -in" tee. When a "cut -in" tee and valve(s) assembly is required on the Plans, the Contractor shall provide and install the entire assembly (including valves), and any other hardware necessary under City Public Works Department inspection, and shall provide all other work and materials necessary to complete the installation to City Standards. During the work, the Contractor shall exercise all necessary precautions to prevent the entrance of trench water or any other foreign material into the water main and shall conduct all operations Construction Specifications 1120 Volume 3 for Public Improvements Revised October 2010 in accordance with the most stringent sanitation practices. The interior of all appurtenances being installed shall be thoroughly swabbed with a strong HTH solution prior to installation. Tie -in or cut -in tee connections to cast iron, PVC, or ductile iron pipes shall be made with mechanical joint solid sleeves. Flexible connections shall only be used when connecting to asbestos cement pipe. Pipe and fittings furnished for tie -ins shall be no smaller than the existing water main to which each tie -in is made. Fire hydrant tie -in shall be considered as a water main tie -in, including the gate valve. Fire service tie -in shall be considered as a water main tie -in, including the gate valve. 99 -1.21 Water Main Component Reporting. The Contractor shall submit the material type, manufacturer, and model number of all water system components to the City inspector prior to final testing. A water system materials form will be provided to the Contractor for this reporting. 99 -1.22 Construction Water Construction water shall be obtained from the City water system only at the point(s) designated by the Engineer. The Contractor must obtain permission from the City Public Works Utilities-SerAcesrpgpartment for each metered construction water connection. A deposit for each meter /hydrant will be required which is refundable upon removal of the meter by City forces, less any charges for water used. A non - refundable set -up /removal fee will be charged. Hydrant meters are obtained through the City Finance Department. Contractors are prohibited from operating gate valves or fire hydrants on the City system. Acquisition of water through appropriation at unmetered fire hydrants or other facilities is a violation of City ordinance and State law. Use of construction water from sources other than the City Water System must be approved by the Engineer. The Contractor shall obtain water as specified herein. 99 -1.23 Water Services The Contractor shall install new polyethylene service laterals at the location(s) shown on the Plans, including service saddles, ball valve corporation stop, spacer, inlet and outlet meter valves, meter box(es), traffic loading lids when required, and removal and disposal of old meter Construction Specifications 1121 Volume 3 for Public Improvements Revised October 2010 box(es) when required. Typically new service laterals shall be as close as possible to existing laterals and as directed by the Engineer in the field. New service laterals shall be installed with a minimum horizontal clearance of five (5) feet from sewer laterals. Upon completion and successful testing of new water system, the Contractor shall transfer the existing meter and tie -in the new service to the new meter box under City Public Works Inspector. The Contractor shall coordinate this work to provide minimum customer out -of- service time and inconvenience. Contractor shall notify customers before transferring meter. The Contractor shall turn off house valve and blow off the new service before meter transfer. After transfer, the Contractor shall open hose bib to flush out air and sediment and then turn on house valve. 99 -1.24 Fire Service Lateral Assembly Fire service lateral assembly with appropriately sized tee, pipe, gate valve, and other appurtenances shall be installed at the location(s) shown on the Plans in conformance with City Std. 854, Std. 877, with reference to Std. 879, as directed by the Engineer, and as specified herein. 99 -1.25 Remove and Relocate Existing Fire Hydrant At the location(s) shown on the Plans, the Contractor shall install a hydrant lateral, including tapping sleeve or tee, gate valve, pipe, bury and riser per City Std. 857 with a blind flange for testing, as directed by the Engineer, and as specified herein. Upon satisfactory completion of the new water system, including tie -ins and testing, the Contractor shall remove the blind flange and relocate the existing hydrant barrel to the new lateral. Relocated hydrants shall be out of service no longer than 24 hours. The riser on the old hydrant shall be removed and salvaged per Section 15 -2.04, "Salvage" as specified herein. 99-1.27-26 Valve Removal 111 1111, 11111 MEMO -1 1111 The Contractor shall remove the existing valve, riser, valve box, cover, plug or cap the tee or water main and replace structural section and asphalt surfacing as required at the location(s) shown on the Plans, as directed by the Engineer, and per Section 15 -2.04, "Salvage" as specified herein. Construction Specifications 1122 Volume 3 for Public Improvements Revised October 2010 99-1.2S-27 Valve Box Removal The Contractor shall remove existing valve boxes, (including boxes for blow -offs when required) risers, and covers and replace structural section and asphalt surfacing at the location(s) shown on the Plans, as directed by the Engineer and per Section 6 -1.04, "Salvage" as specified herein. 99-1.2-9-28 Meter Box Removal The Contractor shall remove existing abandoned meter boxes, remove and replace sidewalk per City Std. 235 at the locations shown on the Plans, as directed by the Engineer, and as specified herein. 99-1.3-0--29 Backflow Assembly (Typical Backflow Preventer) The Contractor shall install a double -check valve assembly per City Std. 874 and /or 876 at the location shown on the Plans, as directed by the Engineer, and as specified herein. 99-1.3-130 Cleaning and Flushing New Water Mains The Contractor shall clean and flush water mains in the following manner: The Contractor shall insert a flexible polyurethane foam "swab" (density: 2# per cu. ft.) complete with polyurethane drive seal, into the beginning section of pipe. The "swab" shall remain there until the remainder of the pipeline is completed. Cleaning and flushing shall be accomplished by propelling the "swab" down the pipeline to the exit point with potable water. Flushing shall continue until the water is completely clear. If the cleaning and flushing exit point is through a fire hydrant (8 inch line or smaller) the Contractor shall remove the hydrant internal valve assembly to allow passage of the "swab" After swabbing, proper disinfectant procedures shall be used per Section 99 -1.19 of the City Specifications. Construction Specifications 1123 Volume 3 for Public Improvements Revised October 2010 > > iE Construction Specifications 1123 Volume 3 for Public Improvements Revised October 2010 > > > � nr�� In n i�r�n� n����zrnr�no �zr��� �o w►n�o ��- ►oro��ro > � . . . . . . . . . . n����zrnr�no �zr��� �o > w�►n � . > � � .. . . . . . . . . � � . . . . . . . . . . . . . . . . . . . . . > > > nr�� In n i�r�n� n����zrnr�no �zr��� �o w►n�o ��- ►oro��ro > > n����zrnr�no �zr��� �o > w�►n � . > w ll e-mail h roforo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Construction Specifications for Public Improvements 4-126 Volume 3 Revised October 2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Construction Specifications for Public Improvements 4-126 Volume 3 Revised October 2010 of work and no additional allowance will be made therefore. Construction Specifications for Public Improvements 4-127 Volume 3 Revised October 2010 . . . . . . . . . . . . . . . . . . . . . . . . . of work and no additional allowance will be made therefore. Construction Specifications for Public Improvements 4-127 Volume 3 Revised October 2010 Construction Specifications 128 Volume 3 for Public Improvements Revised October 2010 Construction Specifications 129 Volume 3 for Public Improvements Revised October 2010 Construction Specifications 130 Volume 3 for Public Improvements Revised October 2010 completed and the asphalt concrete has been placed around the manhole. Prior to the become the property of the Contractor and if undamaged and thoroughly cleaned of Construction Specifications 132 Volume 3 for Public Improvements Revised October 2010 SECTION 100 -2 — ADJUST VALVE COVERS, CLEANOUTS AND MONUMENTS TO GRADE Existing valve covers, cleanouts, and monuments located within the street section shall be adjusted to conform to finished pavement grades. Contractor shall accurately locate and record the location of existing valve covers cleanouts, and monuments to be raised to grade and shall furnish the Engineer a copy of said record prior to starting construction. All sections of valve covers, cleanouts, monuments, and grade rings shall be set in cement mortar the same day that the grade rings are placed. Asphalt concrete paving over cement mortar shall be installed by the end of the following work day. All silt and debris shall be removed from valve boxes and monument vaults. This shall include all existing silt and debris plus material caused by the Contractor's operation. Construction Specifications 133 Volume 3 for Public Improvements Revised October 2010 - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - Construction Specifications 133 Volume 3 for Public Improvements Revised October 2010 SECTION 100 -7 — SACKED CONCRETE RIPRAP Sacked concrete riprap shall be constructed at the location and in accordance with the details shown on the Plans and as directed by the Engineer. Sacked concrete riprap shall conform to the applicable provisions of Section 72 -4 of the Standard Specs cations; - - - - - - - - - - MUM - -- - - - - - - - - -- - - - - Construction Specifications 134 Volume 3 for Public Improvements Revised October 2010 SECTION 100 -8 — REINFORCED CONCRETE HEADWALL A reinforced concrete headwall shall be constructed with the details and at the location shown on the Plans. Bar reinforcing steel shall conform to and be placed in accordance with the applicable provisions of Section 52 of the Standard Specifications, with the following modifications. In lieu of the sampling of reinforcing steel as provided under Article (d) of Section 52 -1.04 of the Standard Specifications, the Contractor shall furnish the Engineer with a certificate from the supplier of the reinforcing steel stating that the steel delivered complies with the requirements of Section 52 -1.02 of the Standard Specifications. Concrete for the headwall shall be Class "A" Portland Cement Concrete conforming to the requirements of Section 90 of the Standard Specifications. Construction Specifications 135 Volume 3 for Public Improvements Revised October 2010 and as specif ed herein. 10 . . Construction Specifications 136 Volume 3 for Public Improvements Revised October 2010 SECTION 100 -10 — REMOVE AND RESET MAILBOX Existing mailboxes shall be removed and reset in accordance with the Plans and as specified herein. Existing posts that are not suitable shall be replaced with temporary timber posts of good, sound material suitable for the purpose intended. Concrete for the pedestals shall be produced from commercial quality aggregates and cement shall contain not less than 5 sacks of cement per cubic yard. Redwood posts and planks shall be constructed of construction clear redwood, free of heart center, rough. Existing mailboxes shall be removed and reset on portable mounts consisting of concrete pedestals formed in 5- gallon cans or buckets during construction. Newspaper boxes attached to existing mailbox posts shall be removed and fastened to the new mailbox posts .,na „ ,.., *° r °m* .,,;" b° niaa° *h°,. °f ,. During the construction operations, the mailboxes shall be moved as necessary to clear the way for the Contractor's operations, but at all times shall be accessible for rural delivery. When construction is complete, the posts and pedestals shall be removed and disposed of as provided in Section 15 -2 of the Standard Specifications and the mailboxes shall be installed in final position on new redwood posts and planks. -- - - - - - - - - - - - - - - - - - - - - - - - Construction Specifications 137 Volume 3 for Public Improvements Revised October 2010