Loading...
2003/01/28 City Council Resolution (3)RESOLUTION NO. 2003- 18 APPROVAL OF WINZLER & KELLY SCOPE OF WORK AND ESTIMATED FEE FOR THE ENGINEERING ANALYSIS OF THE WASTEWATER POND RELOCATION PROJECT WHEREAS, at the December 19, 2002 meeting, the City Council had approved the selection of Winzler & Kelly to perform the engineering analysis as a result of receiving and reviewing Statement of Qualifications from two firms for the work; and WHEREAS, Winzler & Kelly provided a detailed scope of work, estimated fee and project schedule in a letter proposal dated January 9, 2003 and said scope, fee and schedule was reviewed and accepted by the Public Works Manager. NOW, THEREFORE, the scope of work, and estimated fee and schedule are approved and Winzler & Kelly is authorized to proceed with the work as described in the January 9, 2003 letter proposal. DULY AND REGULARLY ADOPTED this 28th day of January, 2003. ATTEST: CITY OF ROHNERT PARK �..•°— e Mayor MW FLORES: AYE MACKENZIE: AYE NORDIN: AYE SPRADLIN: AYE VIDAK- MARTINEZ: AYE AYES: (5) NOES: (0) ABSENT: (0) ABSTAIN: (0) Attachment A WINZLER(STKELLY C 0 N S U L T I N -G - E N G I N E E R. S Ref: PP- 2200 -01004 January 9, 2003 Mr. Steve Donley Acting City Manager 6750 Commerce Blvd Rohnert Park, CA 94928 -2486 Re: Wastewater Pond Relocation Project — Proposed Scope of Work and Fee Estimate Dear Stever Thank you for selecting Winzler & Kelly Engineers to perform this work. The purpose of this letter is to provide you with a scope of work, a fee estimate and a project schedule for the work. Our approach consists of four (4) major.tasks as listed below: Project Management Pond Closure Pump Station and Discharge Pipeline Capacity Analysis • Letter Report A detailed description of each task covered under this proposal is provided below: In order to keep costs to a minimum, we have prepared a scope of work that involves City key decisions that can be made along the way to provide a more focused study. SCOPE OF WORK Task A — Project Management and Coordination Project management and coordination tasks consist of the following': • Kickoff meeting with City staff, Develop project work plan, • As- needed progress meetings with City staff (up to 6) and one in -house workshop, • Prepare monthly project status reports, • Overall coordination of the QA / QC effort. In addition to the normal project administrative duties, the project manager will provide technical oversight of the analysis and planning efforts. This ensures the final product is consistent with the City's goals and objectives, while meeting budget and schedule commitments. Creative Solutions for Over 50 Years 495 Tesconi Circle, Santa Rosa, CA 95401.4696 tel 707.523.1010 fax 707.527.8679 www.w- and -k.com ZLERsZ.I<1F_LLY C O N S U l T 1 N G E N G 1 N E E R S Mr. Steve Donley January 9, 2003 Page 2 Deliverables: Monthly Project Status Reports (6) Task B - Pond Closure Analysis The primary goal of this project is to develop the land that is currently used for the City's wastewater ponds. The ponds are expected to contain significant amounts of residual biosolids that must be characterized prior to disposal. Once this is done, alternatives for disposal can be determined along with the associated costs. Thus, the pond closure analysis essentially consists of the work necessary to: • Estimate the volume and general characteristics of the existing biosolids and underlying soils; • Evaluate sludge disposal alternatives; and Prepare a pond closure plan. A detailed description of each subtask is provided below. Subtask B.l — Sample Collection and Data Analysis The volume of accumulated biosolids in both ponds will be estimated by taking representative samples from the pond bottoms. Because the ponds are unlined, we expect some biosolids and /or other contaminants will have leached or otherwise commingled into the underlying native soils. . To quantify this, we will take samples from both the biosolids layer and the subgrade soils. Based on our review of the pond geometry, we plan to take a total of thirty-two (32) biosolids samples (16 each pond), and eight (8) subgrade samples (4 each pond). The subgrade samples will be taken at a depth of approximately eighteen (18) inches below the apparent pond bottom. Sample collection will be coordinated with a laboratory selected by the City. After the samples are collected, they will be composited and prepared for constituent analysis. Laboratory analysis will test for fuels, solvents, metals, fecal coliform, pH, conductivity, organic content, percent dry solids, and nutrients. These tests should be sufficient to determine the feasibility of various disposal options. Deliverables: Lab test results - one (1) copy City- Provided Services: • City will contract separately with the laboratory of their choice for purposes of analyzing the biosolids and soil samples collected by Winzler & Kelly. �' WINZLER�ZK�I -LY G O. N S U L T -I N G E N G I N E E R S Mr. Steve Donley January 9, 2003 Page 3 Task B.2 —Pond Closure Alternative Analysis Up to four (4) alternatives for closing each of the ponds will be evaluated. This proposal assumes that those alternatives will be: No disposal or treatment other than blending biosolids with native subgrade soils present at the site; Relocating biosolids and contaminated soils from one pond to the other without further treatment; Treating biosolids and contaminated soils to meet EPA's standard for Class -A biosolids (exceptional quality suitable for unrestricted use) and leaving in place; and Removing biosolids and contaminated soils for treatment and disposal via the Laguna Subregional Composting Facility. Engineering requirements, relative benefits, and budgetary cost estimates for each alternative will be developed and compared. Winzler & Kelly will then meet with City staff to present our findings and recommendations. Once the City has selected their preferred alternative, Winzler & Kelly will meet with representatives of the Regional Water Quality Control Board to obtain approval of the proposed pond closure method. Deliverable: Technical Memorandum No. 1— Pond Closure Analysis Task C — Pump Station and Discharge Pipeline Capacity Analysis Winzler & Kelly will compare the existing pump station capacity with the design capacity necessary to accommodate planned growth and closure of one or both ponds. The existing trunk sewer may not be compatible with a significant increase in design capacity due to the increased pressures. Therefore, up to three pipeline /lift station alternatives will be evaluated. They are: Use existing trunk sewer if compatible; Slipline existing trunk sewer with compatible pipe; and Construct new parallel trunk line. Engineering requirements, relative benefits, and budgetary cost estimates for each pipeline /lift station alternative will be developed and compared. Winzler &Kelly will then meet with City staff to present our findings and recommendations. Once the City has selected their preferred alternative, Winzler & Kelly will prepare a technical memorandum that summarizes each option. WINZLER<S _I<Z Y -C O N S U L T I N G E N G I N E E R S Mr. Steve Donley January 9, 2003 Page 4 Meetings: • Design Workshop — present project alternatives to .City staff — select preferred alternatives. Deliverables: • Technical Memorandum No. 2 — Pump Station and Pipeline Capacity Analysis • Meeting minutes City- Provided Data: • Record drawings, O &M manuals, and specifications of existing utility infrastructure • Historical influent hydrograph (flow vs. time) data • General Plan and all other pertinent studies and flow projections • Current discharge agreement with the sub - regional partners Task D — Letter Report The technical memoranda will be compiled and edited to form a final feasibility report. In addition, the report will include an executive summary and appendices of calculations and lab results. Deliverables: • Final Letter Report — Pond Closure Feasibility Study Schedule We have prepared a workplan that allows us to complete the feasibility report over a six -month period. This timetable includes up to four (4) weeks of City review time. The attached bar chart illustrates our proposed work plan with estimated due dates for each deliverable. To achieve the greatest accuracy, sampling work will be scheduled to occur when the ponds are drained and accessible by foot. Based on our discussions with City staff, we expect that the ponds will be ready for sampling some time in March 2003, weather depending. Using this schedule, and assuming the City issues a notice to proceed by January 17, 2003, Winzler & Kelly would issue the final report by July 9, 2003. Budget Winzler & Kelly proposes to perform Tasks A through D described above for a fee of $19,950, billed monthly based on the time and materials expended at our standard labor rates. Reimbursable expenses will be billed in accordance with the Winzler & Kelly's standard rate schedule. A detailed labor estimate for each task is summarized in the attached table. .� WINZLERSZ,I�ELLY C O N S U .L T I N G E N G I N E- E R 5 Mr. Steve Donley January 9, 2003 Page 5 Please feel free to contact me at your earliest convenience to discuss any aspect of this proposal. We look forward to working with you and your staff. Sincerely, WINZLER & KELLY Toni Bertolero, P.E. kj Attachments: Labor Estimate /Fee Budget Bar Chart Schedule / Work plan c: Bill Stephens, Public Works Manager Rod Houser, Winzler & Kelly Elizabeth. Cargay, Winzler & Kelly Marc Solomon, Winzler & Kelly 1/15/2003 Rohnen Perk Pond Closure Budget.rds Pre Bred : Rod Houser roved Toni BedoI.. J#: P2- 224303004 CITY OF ROHNERT PARK Labor Rates dace: irM3 POND CLOSURE PROJECT Ver:1 Staff Designe, ! PIC $ 1d0 OA/QC 5 135 Pro M r $ 120 Sr Geola ist $ 105 StaffE r S 95 Scientist S 75 CAD S 80 VIP S 50 Task HOUrs Labor Cost Reimbemibles Subconwltents ns- Task COSt 2,720 - 20 2 - 22 $ 2,610 $ 110 $ - $ - P Task A - Project Management - 2 2 4 4 $ 450 $ 480 $ 20 $ 20 $ $ $ $ $ 470 $ 500 kickoff meeting refine workplan 6 6 $ 720 $ 30 $ $ $ 750 monthly progress re l? (6) 6 2 W74 6 2 $ 720 $ 240 $ 30 $ 10 $ $ $ $ $ 750 $ 250 update project staffing QA/QC 2 24 4 14 118 $ 9 360 $ 590 $ - $ - $ 9,950 Task B -Pond Closure Analysis - 2 - 6 18 32 4 4 30 46 $ 2,450 $ 3, 650 $ 150 $ 230 $ $ $ $ $ 2,600 $ 3, 880 8. i - sample collection and data analysis B.2 - and closure analysis 10 8 24 4 6 42 $ 3,260 $ 210 $ $ technical memo no. i 2 12 39 4 2 59 $ 5,835 $ 295 $ Task C - Capacity Analysis 2 1 8 4 3 10 5 4 $ 1 000 $ 500 $ 405 $ 50 $ 25 $ 20 $ $ $ $ $ $ 525 $ 425 data collection /review establish design hydrographs calc redd design flow for each ono closure alternative 1 14 $ 1,380 $ develop pump station and pipetine alternatives 2 2 4 2 2 - 12 4 8 8 4 2 8 18 $ .860 $ F 690 $ T design workshop technical memo no. 2 Task D - Letter Report 2 g 2 12 $ compile and edit final letter re ort 4 34 26 47 74 8 18 211 $ 18 905 $ 1 049 $ $ $ 19 954 totals _ 1/15/2003 Rohnen Perk Pond Closure Budget.rds ID @ Task Name Duration Start 4th Quarter 1st Quarter 2nd Quarter 3rd Quarter Sep Oct I Nov I Dec Jan I Feb Mar I Apr May Jun Jul Au 0 Rohnert Park Pond Closure 119 days Fri 1/24/03 Rohnert Park Pond Closure. 719 Task A - kickoff meetinj Task B - pond clbsure analysis 6/6 Task 8.1 - sampling & data analysis ^ 4111 sample collection 3/21 lab analysis 4/4 I vol me calculations 4/11 Task B.2 - alt rnative analysis 6/6 closure alt no. 1 4/18 closure alt no. 2 4/25 closure alt no. N45/9 closure alt no12 sub it draft Tech Memo 16 meeting w/ Ci5123 issue final TM No. 1 5130 meeting w/ RWQC 6/6 p station and pipeline capacity analysis etermine required pump station capacity 2/6 pipeline / lift station altno. 1 2/13 pipeline / lift station 41t no. 2 2/20 pipeline / lift station: alt no. 3 2/27 submit draft Tech Memo No. 2 3/6 meeting w/ City staff 3/13 issui final TM No. 2 3/20 Task D - feasibility repo 719 compile TMs into single document 6/10: executive summary 6/17 appendicies 6118 submit draft report 6/18 city review 712 submit final report 7/9 1 Task A - kickoff meeting 1 wk Fri 1/24/03 2 Task B - pond closure analysis 60 days Mon 3/17/03 3 Task B.1 - sampling & data 20 days Mon 3/17/03 4 rx:. sample collection 1 wk Mon 3/17/03 5 lab analysis 2 wks Mon 3/24/03 6 volume calculations 1 wk Mon 4/7103 7 Task B.2 - alternative analy! 40 days Mon 4/14/03 8 closure alt no. 1 1 wk Mon 4/14/03 9 closure alt no. 2 1 wk Mon 4/21/03 10 closure alt no. 3 1 wk Mon 4/28/03 11 closure alt no. 4 1 wk Mon 5/5/03 submit draft Tech Memo 1 wk Mon 5/12/03 13 meeting w/ City staff 1 wk Mon 5/19/03 14 issue final TM No. 1 1 wk Mon 5/26/03 15 meeting w/ RWQCB 1 wk Mon 6/2/03 16 Task C - pump station and pipeli 35 days Fri 1131103 17 determine required pump stati, 1 wk Fri 1/31/03 18 pipeline / lift station all no. 1 1 wk Fri 2/7/03 19 pipeline / lift station aft no. 2 1 wk Fri 2/14/03 20 pipeline / lift station all no. 3 1 wk Fri 2/21 /03 21 submit draft Tech Memo No. 1 wk Fri 2/28/03 22 meeting w/ City staff 1 wk Fri 3/7/03 23 issue final TM No. 2 1 wk Fri 3/14/03 24 Task D - feasibility report 23 days Mon 6/9/03 25 compile TMs into single docur 2 days Mon 6/9/03 26 executive summary 1 wk Wed 6/11/03 27 appendicies 1 day Wed 6/18/03 28 submit draft report 0 days Wed 6/18/03 29 city review 2 wks Thu 6/19/03 30 submit final report 1 wk Thu 7/3103 Project: Rohnert Park Pond Closure 1 Date: Wed 1/15/03 Task ' �'�' Milestone External Tasks^ - --- !` p External Milestone Slit Summary wa "i,t i„ Progress Project Summary Deadline �J Page 1 �.r :���� STN ZLER�KELLY C 'gip N'S U L T I N G E. N G I N E E R S December 12, 2002 Mr. Joe Netter; City Manager City of Rohnert Park 6750 Commerce Blvd. Rohnert Park, CA 94928 t t a c h 7m7:e:n f B Ref: P2- 220000 -004 nt e: ;Oter Proposal to Provide City Engineering Services Dear Mr. Netter: A 'Winzler & Keily_is pleased to submit this letter proposal to provide the City with city engineering services on an as- needed basis. Currently both the City and Winzler & Kelly are working towards a formal agreement including a scope and estimate of costs for services, which include capital improvement engineering, development review, and general city engineering services. Until that agreement is finalized, the City desires a temporary arrangement to ensure that the role of City Engineer is provided without delay and that there is coverage for ongoing projects that require the immediate review and oversight of the City Engineer. Toni Bertolero will be assigned as the Interim City Engineer and will report to Bill Stephens, the City's Public Works Manager. We acknowledge that the City wishes to maximize the use of the City's Engineering and Public Works staff and Toni will do so. At times, she may need to use Winzler & Kelly technical staff for support services not available to her in the Engineering and Public Works departments, and as approved by the Public Works Manager. It is estimated that Toni will spend approximately one to two mornings (or afternoons) per week at the Rohnert Park City Hall office and will be available to answer calls from the City at our Santa Rosa office. The specific times will be coordinated with the Public Works Manager, depending on the workload and staff needs. Winzler & Kelly is ready to commence with this arrangement, effective immediately, and upon your approval. Attached is a copy of Winzler & Kelly's standard labor charges. Toni's standard hourly rate is $125 per hour, however, for the City engineering services, her hourly rate will be $95 per hour. We acknowledge that this hourly rate is open to negotiation of the engineering services agreement that is ongoing. Creative Solutions for Over 50 Years 495 Tesconi Circle, Santa Rosa, CA 95401.4696 tel 707.523.1010 fax 707.527.8679 www.w- and -k.com 5l �3UI3�TZLERSZ��LLY C O. N: 8 U 'L T I N G E N G I N E E R 5 Mr. Joe Netter December 12, 2002 Page 2 Thank you for selecting Winzler & Kelly for this assignment. We look forward to working with the City. in this key role. If you have any questions regarding this letter, feel free to call me or Toni at 523 -1010. Sincerely, WINZLER & KELLY M c Solomon egion Manager as Attachment'...