2018/08/14 City Council Resolution 2018-112RESOLUTION NO. 2018-112
A RESOLUTION OF THE CITY COUNCIL OF THE
CITY OF ROHNERT PARK, CALIFORNIA, APPROVING A TENTATIVE
SUBDIVISION MAP AND DEVELOPMENT AREA PLAN TO ALLOW THE
SUBDIVISION AND DEVELOPMENT OF PROPERTY (COMMONLY KNOWN AS
THE GEE PROPERTY) LOCATED SOUTH OF KEISER AVENUE AND WITHIN THE
UNIVERSITY DISTRICT SPECIFIC PLAN AREA, CONSISTING OF 42 -SINGLE-
FAMILY RESIDENTIAL LOTS
WHEREAS, the applicant, Stephen Miller, on behalf of Signature Homes, filed Planning
Applications proposing a Tentative Subdivision Map and Development Area Plan to allow the
subdivision and development of property (commonly known as the Gee property) located south
of Keiser Avenue and within the University District Specific Plan Area —APN 045-253-009 thru
-012 (the "Project"), in accordance with the City of Rohnert Park Municipal Code ("RPMC");
and
WHEREAS, pursuant to California State Law and the RPMC, public hearing notices
were mailed to all property owners within a three hundred foot radius of the subject property and
a public hearing was published for a minimum of 10 days prior to the first public hearing in the
Community Voice; and
WHEREAS, on May 23, 2006, the City Council of the City of Rohnert Park certified the
Final Environmental Impact Report (EIR) for University District Specific Plan Area, which
includes the project site and, on April 8, 2014, approved an EIR Addendum; and
WHEREAS, an Environmental Consistency Analysis was prepared for this project,
which concluded that the proposed Tentative Subdivision Map and Development Area Plan are
consistent with the analysis in the EIR and EIR Addendum and would not result in additional
environmental effects, and that, therefore, no additional environmental review is necessary; and
WHEREAS, on December 13, 2017, the Park and Recreation Commission held a public
meeting on the proposed Tentative Subdivision Map and Development Area Plan; and
WHEREAS, the Park and Recreation Commission reviewed and considered the
information contained in the proposed Tentative Subdivision Map and Development Area Plan
and recommended that, in accordance with the provisions of the Rohnert Park Municipal Code
for subdivisions under fifty (50) parcels, an in -lieu fee for parks was appropriate; and
WHEREAS, on June 14, 2018, the Planning Commission held a public hearing at which
time interested persons had an opportunity to testify either in support or opposition to the
proposed Tentative Subdivision Map and Development Area Plan; and
WHEREAS, the Planning Commission reviewed and considered the information
contained in the proposed Tentative Subdivision Map and Development Area Plan; and
WHEREAS, the Planning Commission voted to recommend approval of the proposed
Tentative Subdivision Map and Development Area Plan; and
WHEREAS, on August 14, 2018, the City Council held a public hearing at which time
interested persons had an opportunity to testify either in support or opposition to the proposed
Tentative Subdivision Map and Development Area Plan; and
2018-112
WHEREAS, the City Council has reviewed and considered the information contained in
proposed Tentative Subdivision Map and Development Area Plan; and
NOW, THEREFORE, BE IT RESOLVED that the City Council of the City of Rohnert
Park makes the following findings, determinations and recommendations with respect to the
proposed Tentative Subdivision Map and Development Area Plan:
Section 1. The above recitations are true and correct.
Section 2. CEQA Finding. On May 23, 2006, the City of Rohnert Park certified the
Final EIR for the UDSP project, including adoption of associated CEQA Findings, Statement of
Overriding Considerations, and the Mitigation Monitoring and Reporting Program. On April 8,
2014, the City approved an Addendum to the Final EIR, as described in City Council Resolution
No. 2014-032. An Environmental Consistency Analysis was prepared for this project, which
concluded that the proposed Tentative Subdivision Map and Development Area Plan are
consistent with the analysis in the EIR and Addendum and would not result in additional
environmental effects. Therefore, no additional environmental review is necessary. Pursuant to
CEQA Guidelines Sections 15162 and based on the entire record, the City Council finds that no
new environmental effects could occur and no new mitigation measures are required as a result
of the proposed Tentative Subdivision Map and Development Area Plan. Therefore, no
additional environmental review is required.
Section 3. Findings Regarding Tentative Subdivision Map and Alternative
Equivalent. The City Council, in consideration of Planning Application file number PLDP 17-
0004 for a Tentative Map and Development Area Plan, hereby makes the following findings
concerning the Tentative Subdivision Map pursuant to RPMC Section 16.10.090(E) and
approval of an alternative equivalent to the on-site construction of inclusionary housing pursuant
to RPMC 17.07.020.N:
The proposed map, and its design and improvements, are consistent with the general
plan and any applicable specific plan, anypolicy orguideline implementing the general
plan (including the city's design guidelines), or other applicable provisions of this
code.
Criteria Satisfied. The proposed Tentative Subdivision Map is consistent with the
General Plan designations for the area, as well as the specific plan that applies to the
property. The proposed Tentative Map will implement the General Plan in that it would
increase the City's existing housing stock. The Tentative Map will comply with the
goals and policies of the City's Housing Element by complying with the City's
inclusionary housing ordinance through payment of in -lieu fees.
The proposed Tentative Map is consistent with the revised University District Specific
Plan as it proposes to subdivide the property according to its requirements related to
number of residential units, density, housing type, housing location, public
improvements, open space and related amenities. The Tentative Map depicts the
specific residential lots consistent with the Specific Plan.
The proposed Tentative Map has been designed to meet City standards which provide
satisfactory pedestrian and vehicular circulation, including emergency vehicle access
and on site improvements, such as streets, utilities, and drainage facilities have been
designed and are conditioned to be constructed in conformance with City standards.
2
2018-112
2. The site is physically suitable for the type of development.
Criteria Satisfied. The Tentative Map reflects the specific plan for this site, which is
physically suitable for the proposed development. No major geologic hazards have
been reported on the site or other limited conditions that would render it unsuitable for
residential development.
3. The site is physically suitable for the proposed density of development.
Criteria Satisfied. The site is of sufficient size and shape and appropriately shown in
the Specific Plan to allow the proposed density of development. The subdivision has
been designed to accommodate the development of 42 residential units, taking into
consideration the shape and topography of the site. This development is consistent with
the density ranges provided for in the Specific Plan.
4. The design of the subdivision or the proposed improvements will not cause substantial
environmental damage or substantially and avoidably injure fish or wildlife or their
habitat, absent a statement of overriding conditions.
Criteria Satisfied. An Environmental Impact Report (EIR) for the University District
Specific Plan Project (State Clearinghouse number 2003112011) and Addendum to this
EIR has been prepared and approved which shows potential impacts related to the
development of the site with the proposed uses. No significant unavoidable impacts
related to existing habitats were identified. The Final EIR for this Project includes
adoption of associated CEQA Findings, Statement of Overriding Considerations, and
the Mitigation Monitoring and Reporting Program. The contents of the Final EIR are
incorporated herein by this reference. A consistency analysis has been prepared to in
connection with the proposed project which demonstrates the project would not result
in new impacts.
5. The design of the subdivision or the type of improvements will not cause serious public
health problems.
Criteria Satisfied. The design of the project is not expected to have negative impacts
on the health or wellbeing of project residents or occupants of the surrounding land
uses. The design of the Tentative Map is in conformance with the City's General Plan,
Zoning Ordinance, and Subdivision Ordinance. The construction of all units on the site
has been conditioned to comply with all applicable City ordinances, codes, and
standards including, but not limited to, the California Uniform Building Code, the
City's Ordinances relating to stormwater runoff management and controls. In addition,
the design and construction of all improvements for the subdivision has been
conditioned to be in conformance with adopted City street and public works standards.
The City's ordinances, codes, and standards have been created based on currently
accepted standards and practices for the preservation of the public health, safety and
welfare. Finally, the proposed street system throughout the subdivision will improve
emergency vehicular access and in the immediate neighborhood.
6. The design of the subdivision or the type of improvements will not conflict with
easements, acquired by the public at large, for access through or use of property with
the proposed subdivision, absent alternative, equivalent easements.
2018-112
Criteria Satisfied. The project will respect all existing easements, and any new
easements required by the project have been made conditions of the map approval.
7. Any proposed phases and their proposed sequence of construction are identified on the
submitted map.
Criteria Satisfied. The project is a 42 -unit development proposal that will be
constructed in a single phase.
8. The provision of an alternative equivalent to the construction of inclusionary housing
will further affordable housing opportunities in the city to an equal or greater extent
than compliance with the express requirement to construct units and an over
concentration of affordable housing in one area will not occur.
Criteria Satisfied. Payment of an in -lieu fee will further affordable housing
opportunities in the city to an equal or greater extent that constructing units on-site. The
City has recently approved the Development Area Plan for a 218 -unit apartment
complex in the University District Specific Plan Area, less than one mile from the
proposed project. The complex, which will be affordable low and very low income
residents, provides enough housing to satisfy the City's current Regional Housing
Needs Allocation for these income categories. The City's development agreement with
the University District ensures that construction will begin on the new complex no later
than next spring and guarantees completion of construction. As such, payment of the
fee will provide the City with revenue, to use alone or in combination with other City
housing funds and/or other funding sources, in order to diversify its investment in
affordable housing. Specifically, investing in the preservation of existing affordable
housing, is a high priority in order to satisfy the City's Housing Element and its
Regional Housing Needs Allocation. Payment of the fee will allows for investments
outside of the University District Specific Plan Area, where substantial investment is
being made, and will avoid an over concentration of affordable housing in one area.
Section 4. Findings for Approval of Development Area Plans. The City Council, in
consideration of Planning Application file number PLDP17-0004 for a Tentative Map and
Development Area Plan, hereby makes the following findings concerning the Development Area
Plan findings in accordance with Rohnert Park Municipal Code Section 17.06.400:
1. The proposed development conforms to the applicable specific plan.
Criteria Satisfied. The Bristol Development Area Plan (DAP) submittal is consistent
with the Specific Plan and provides additional details on the project including
residential floor plans and elevations by housing type, and landscaping details and
specifications. The proposed DAP is consistent with the Specific Plan because it
conform to the requirements in the Specific Plan related to density, housing type,
housing location, public improvements, landscaping, and related amenities. The DAP
is designed to have adequate infrastructure and be integrated with existing City
roadways, streets, bicycle paths, and walkways. All streets and thoroughfares will meet
the standards of the City as is required by the Specific Plan. The recommended
conditions of approval for the DAP ensure that implementation of the Development
Area Plan will remain consistent with the Specific Plan, Tentative Map, and mitigation
measures.
4
2018-112
2. Public infrastructure and services can be provided concurrently with the development.
Criteria Satisfied. The developer will be required to participate in the Public Facilities
Financing Plan, which will provide for necessary off-site public facilities, and shall be
responsible for on-site facilities to meet the project's needs. The Conditions of
Approval for the project sets forth the timing of the necessary facilities as they relate
to the physical development of the site.
Section 5. A duly noticed public hearing on the proposed Tentative Subdivision Map
and Development Area Plan was held on August 14, 2018.
Section 6. Based on the findings set forth in this Resolution and the evidence in the staff
report, the City Council hereby approves the Tentative Map, with payment of an housing in -lieu
fee and a park in -lieu fee, and Development Area Plan, as set forth at Exhibit A, in its entirety,
and subject to the recommended conditions of approval as amended in their entirety in Exhibit B.
Except as modified herein with respect to the Bristol Neighborhood, the Vast Oak East
Development Area Plan I1 remains in full force and effect.
DULY AND REGULARLY ADOPTED on this 14th day of August, 2018.
CITY OF ROHNERT PARK
Pam Stafford, Mayor
ATTEST:
?JZne M. Buergler, City Clerk
Attachment: Exhibit A and Exhibit B
AHANOTU: A_JC BELFORTE: A*�e MACKENZIE: a� e CALLINAN: S�-SSTAFFORD:
AYES: ( u ) NOES: ( 0 ) ABSENT: ( ) ) ABSTAIN: ( O )
5
2018-112
Exhibit A to Resolution
GENERALNOTES
1. OWNER:
MILTON T. GEE TRUST
917 WRIGHT STREET
SANTA ROSA CA 95404
2. AGENT/ SUBDIVIDER:
SIGNATURE HOMES
4670 WILLOW ROAD, SUITE 200
PLEASANTON CA 94588
CONTACT: STEPHEN MILLER 925-463-1122
3. PLANNING/ ENGINEER/ SURVEYOR:
MACKAY & SOMPS CIVIL ENGINEERS
5142 FRANKLIN DRIVE SUITE B
PLEASANTON, CA 94588
CONTACT: JIM TEMPLETON / ABEL GOMEZ (925) 225-0690
4. GEOTECHNICAL ENGINEER:
ENGEO INC.
2010 CROW CANYON PI #250
SAN RAMON, CA 94583
5. ARCHITECT:
WOODLEY ARCHITECTURAL GROUP
2943 PULLMAN STREET, SUITE A
SANTA ANA, CA 92705
6. BASIS OF ELEVATIONS - BENCHMARK:
ON SNYDER LANE, 1000 FEET NORTH OF KEISER AVENUE
IN WEST HEADWALL OF CONCRETE CULVERT; STANDARD
TABLET STAMPED "6 GWM 1943 116" (RESET 1981)
ELEV. 119.925 (NGVD 29)
W
H
VESTING TENTATIVE MAP
I
A PROPOSED RESIDENTIAL COMMUNITY
0
U�
ROHNERT PARK, CALIFORNIA
7. BASIS OF BEARINGS:
THE BEARING OF N 00°01'44" W AS SHOWN BETWEEN FOUND MONUMENTS ON THE RECORD OF SURVEY
FILED IN BOOK 525 OF MAPS AT PAGES 37-39, SONOMA COUNTY RECORDS, PET#5 TO PET#1 C/L OF
PETALUMA HILL ROAD.
8. ASSESSOR'S PARCEL NUMBERS: 045-253-012-000, 045-253-011-000, 045-253-010-000, 045-253-009-000
9. PROPERTY ACREAGE: 6.21 ACRES
10. EXISTING LAND USES INCLUDE THE APPROVED 2006 UNIVERSITY DISTRICT SPECIFIC PLAN AMENDED 2014. PROPOSED LAND USES WILL BE BASED ON THE
PROPOSED UNIVERSITY DISTRICT SPECIFIC PLAN AMENDMENT.
11. INDIVIDUAL LOT AND PARCEL SIZES ARE SHOWN ON TENTATIVE MAP SHEET 2. THE AGENT RESERVES THE RIGHT TO ADJUST LOT WIDTHS UP TO 2 FEET (SO
LONG AS THEY MEET THE REQUIRED SETBACKS) AND ARE STILL IN CONFORMANCE WITH THE APPROVED MAP. FOR REFERENCE THE SMALLEST AND
LARGEST FOR SALE LOTS ARE:
• SMALLEST - 52'X 81'= 4,160 SF (LOT 22)
• LARGEST - 70' X 100' = 6,974 SF (LOT 16)
12. EXISTING PROPERTY USE: DRY FARMED AGRICULTURAL LAND
13. AREAS SUBJECT TO INUNDATION: NONE PER FIRM PANEL 881 OF 1150 AS DEFINED BY FEMA.
14. PERMANENT AND CONSTRUCTION ACCESS FOR THIS PROJECT SHALL BE FROM KEISER AVENUE. AGENT RESERVES THE RIGHT FOR FUTURE ACCESS TO
THIS STREET.
15. THE APPLICANT RESERVES THE RIGHT TO FILE MULTIPLE FINAL OR PARCEL MAPS ON THE PROPERTY AS LONG AS THEY ARE IN GENERAL CONFORMANCE
WITH THE APPROVED TENTATIVE MAP.
16. UNLESS OTHERWISE SPECIFICALLY STATED IN THE CONDITIONS OF APPROVAL, LOCAL AGENCY APPROVAL OF THIS MAP SHALL CONSTITUTE AN EXPRESS
FINDING THAT THE PROPOSED SUBDIVISION AND DEVELOPMENT OF THE SUBJECT PROPERTY WILL NOT UNREASONABLY INTERFERE WITH THE FREE AND
COMPLETE EXERCISE OF RIGHTS DESCRIBED IN GOVERNMENT CODE SECTION 66436(a)(3)(A)(i).
17, FACE OF CURB RADII ARE 25' (MIN) AT INTERSECTION/ CURB RETURNS.
18. LANDSCAPE AND FENCING DETAILS FOR THE RESIDENTIAL AREA AS WELL AS THE PRIVATE HOA PARCELS WILL BE CONCEPTUALLY DETAILED WITH THE
DEVELOPMENT AREA PLANS (DAP). ADDITIONALLY, THE DAP WILL PROVIDE DETAIL ON UNIT MIX, SETBACKS AND PARKING REQUIREMENTS.
19. LANDSCAPE PLANTING AND FENCING DETAILS FOR THE WATER QUALITY / DETENTION BASIN WILL BE CONCEPTUALLY DETAILED WITH THE DEVELOPMENT
AREA PLANS (DAP).
20. ON SHEETS 3 AND 4 THE PRELIMINARY GRADES AND UTILITY ROUTING ARE SUBJECT TO CHANGE BASED ON FINAL DESIGN.
21. DOMESTIC WATER SERVICE TO BE PROVIDED BY CITY OF ROHNERT PARK. WHEN INSTALLED IT SHALL CONFORM WITH CITY OF ROHNERT PARK
STANDARDS. LOCATION OF FIRE HYDRANTS TO BE COORDINATED WITH CITY'S PUBLIC SAFETY DIVISION PRIOR TO FINAL DESIGN.
22. SEWAGE SERVICE TO BE PROVIDED BY CITY OF ROHNERT PARK. WHEN INSTALLED IT SHALL CONFORM WITH CITY OF ROHNERT PARK STANDARDS.
23. ELECTRIC AND GAS SERVICE TO BE PROVIDED BY PACIFIC GAS & ELECTRIC. WHEN INSTALLED IT SHALL BE IN CONFORMANCE WITH CITY OF ROHNERT
PARK AND PG&E STANDARDS.
24. TELEPHONE SERVICE TO BE PROVIDED BY AT&T (FORMERLY SBC) AND SHALL ADHERE TO THEIR STANDARDS WHEN INSTALLED.
25. SCHOOL DISTRICT: BRISTOL WILL BE SERVICED BY THE COTATI-ROHNERT PARK UNIFIED SCHOOL DISTRICT.
26. PARKWAY STRIPS WITHIN PUBLIC STREETS AND WITHIN OPEN SPACE PARCELS AS SHOWN ON THIS MAP WILL BE MAINTAINED BY THE HOMEOWNERS
ASSOCIATION (HOA).
27. FOR ALL LOTS INCLUDING COURTYARD PRODUCTS, ON LOT DRAINAGE SHALL FLOW TO THE FRONT OF EACH LOT. THE DRAINAGE PATTERNS WILL BE
BETTER REFINED WITH THE DAP PROCESS.
28. LIGHTING WITHIN PUBLIC STREETS SHALL MEET CITY STANDARDS. LIGHTING WITHIN THE PRIVATE ALLEY MOTOR COURTS SHALL MEET THE CRITERIA
ESTABLISHED IN THE SPECIFIC PLAN AMENDMENT.
29. UPON APPROVAL OF THIS MAP, APPLICANT ACKNOWLEDGES THAT ADDITIONAL STUDIES MAYBE REQUIRED WITH FINAL DESIGN TO IMPLEMENT CONCEPTS
SHOWN ON THIS TENTATIVE MAP APPLICATION. ADDITIONAL EASEMENTS, DEED RESTRICTIONS AND OR MAINTENANCE AGREEMENTS MAY BE NEEDED AS
DETERMINED DURING THE FINAL DESIGN. PLANS FOR ALL ONSITE/OFFSITE IMPROVEMENTS WILL BE PREPARED AND SUBMITTED TO THE APPROPRIATE
AGENCIES FOR APPROVAL PRIOR TO COMMENCEMENT OF CONSTRUCTION.
30. PARCEL A (WATER QUALITY BASIN) WILL NOT BE DEDICATED TO THE CITY BUT WILL BE MAINTAINED BY THE HOA.
31. PARCEL B (ACCESS TO SCHOOL SITE) WILL BE DEDICATED TO THE CITY BUT MAINTAINED BY THE HOA.
32. PARCEL C (6' LANDSCAPE AREA) WILL BE DEDICATED TO THE CITY BUT MAINTAINED BY THE HOA.
05-01-2018 9:47am Abel Gomez P:\19907\PLN\TM\IM-0I-COVER SHEET.DWG
MAY 2018
1")Mrl lr!%T C%ITr
VICINITY MAP / JURISDICTION LIMITS
NTS
INDEX OF SHEETS
SHEET NO.
DESCRIPTION
1
COVER SHEET
2
TENTATIVE MAP - PROPOSED LOTTING PLAN
3
UTILITY PLAN
4
GRADING PLAN
5
STORMWATER MANAGEMENT PLAN
6
FIRE AND GARBAGE PLAN
0
z
C) Uj
C14Q
0
az
m o 0
LL
w � v
Q Q n w
Q 0 11� W =
o Un o o v
�o
�N
E� ao
LEGEND
y
PROPOSED DESCRIPTION EXISTING
a
�U w
--•--•- PROPERTY BOUNDARY -------
W =
zz ��
420 CONTOUR
Q�
Q NQ
a o=
PARCEL LINE/LOT LINE -----------
J
�w
o =_
RIGHT-OF-WAY - -
�■ z
No
Y
z 't
------ EASEMENT------
�Q
Q
- - VALLEY GUTTER
wm
E �o
z
w� �o
FENCE
PEDESTRIAN RAMP (AT ALL CORNERS)
o
PER SONOMA COUNTY STD. DWG 224A
... .... - RECYCLED WATER LINE (SIZE INDICATED) -- -- -
0
0
CITY LIMIT LINE
��
+� - RECYCLED WATER GATE VALVE -- �- -
v
ER �
SANITARY SEWER & MANHOLE - - -0- - -
JR
-••••- STORM DRAIN & MANHOLE----�----
o
d
-•• ••- STORM DRAIN CATCH BASIN ----D
v
c
o
LIMITS OF COTATI -
"- WATER LINE & VALVE
=
W
- -0 WATER LINE & METER - -fl
O''d
P
ROHNERT PARK
v
FIRE HYDRANT WITH VALVE
UNIFIED SCHOOL
SLOPE ------K�
N
DISTRICT
- BLOW -OFF VALVE ASSEMBLY ------a
a
Uj
CLEANOUT - - - - -
z
STREET LIGHT ��
a
Q
Z
af
O
w
J
Q
U
0.
Q
ABBREVIATIONS
AB - AGGREGATE BASE MAX - MAXIMUM
W
AD - AREA DRAIN MIN - MINIMUM
APN - ASSESSORS PARCEL NUMBER N - NORTH
\
BO - BLOW -OFF P - PAD GRADE
BNDY - BOUNDARY PAE - PUBLIC ACCESS EASEMENT
W
C&G - CURB & GUTTER PCC - PORTLAND CONCRETE CEMENT
Q J
W
CB - CATCH BASIN P/L - PROPERTY LINE
O
OC
C/L - CENTERLINE PS - PROTECTIVE SLOPE
' S2CO
- CLEANOUT PVC - POLYVINYL CHLORIDE
L mLU
D/W - DRIVEWAY PUE - PUBLIC UTILITY EASEMENT
Y.1
DWG - DRAWING R - RADIUS
O
V
E - EAST R/W - RIGHT OF WAY
EL - ELEVATION S - SOUTH
EP - EDGE OF PAVEMENT SD - STORM DRAIN
ESMT - EASEMENT SDCB - STORM DRAIN CATCH BASIN
a
EVAE - EMERGENCY VEHICLE ACCESS EASEMENT SDMH - STORM DRAIN MANHOLE
EX - EXISTING SF - SQUARE FEET
'^
w
FC - FACE OF CURB SS - SANITARY SEWER
�I,
r
FG - FINISH GRADE SSCO - SANITARY SEWER CLEANOUT
W
0
FH - FIRE HYDRANT SSMH - SANITARY SEWER MANHOLE
>
FI - FIELD INLET STLT - STREET LIGHT
w
O
FL - FLOW LINE STD- STANDARD
r
FUT -FUTURE S/W - SIDEWALK
U
GB - GRADE BREAK TC - TOP OF CURB
HP - HIGH POINT TRC - TOP OF ROLLED CURB
-'
INV - INVERT TCB - TOP OF BAND CURB
19907
-OC
IRR - IRRIGATION TYP - TYPICAL
L/S - LANDSCAPE W - WATER
LF - LINEAR FEET WM - WATER METER
SHT
LP - LOW POINT WQ - WATER QUALITY FEATURE
LTSG - LIME TREATED SUBGRADE
OF 6
x119.4 x1197 120 1 x120.2 x120.5 I x120.7 i 122.2x
22`.2x122.5 1
x 121.6 I I I 123.6
x
1 I x119.1 I x119.5 x119.5 I 119.5 I 120.4 120.7 I 122.8
119.6 x x x x
3.2 x118.7 x I I I r I r r
JOHN NUIN S TRUST J0H11 11J1�1rS 7RJ� RAII�/1OIND -?c CI/\1Pr HAIL rY 1/10HA���IJ��lr\O r
JOHN \l V \ \ r� c -
r o w x 119.7 126 APA J, OTTER Jr L L 1CL ES INC. ROBERT DENNISrS �/1G1L TRUST
I r r I ��ilr\PrIY J.��iIAPf<NA��iI c I SCHLr l'H ET AL I C�J�NINIr ASSADI I X I I I 123.6
1 APIN 045-252-011 API�I 045-252-01 � w APIA 045-252-026 APINI 045-252-025 APIA 045-252-015
x ------- 118.6 APN 0��5-252-011 Y API�I 0415-252-024 API�I 0415-252-023 �,
x 121.4 x 122.6
1 x x 118.7 x 119.1 119.9 120.8 - - - - - x �, �' - - I-
x �.
---- ------ ----- ----- ------ - ---- ---y- ------ ----- ----- -- --- ------ ----- ------ ---- ---- ----- ---- ------ ----- ------ ------ ----- ----- ----- --- ---- - ----- 1-- ------ ----- ------ -
----------------------
119.1
---------------------119.3 _ _x119.4 _ 119.61 20.5 0 "120.1 x120.5 _ X0.8_ _ _ x121.2 _ _ X KEISER AVENUE'21.s _ --_ - - X2.4_ _ - x123.0 - _x123.4 -x 123.6 - - _124.6E -
x 118.6y - N89°24' 36"E 891 .4BNDY
KEISER AVENUE DEDICATION PARCEL C 614' KEISER AVENUE DEDICATION
670'
A
70' j62'-�90' 90' 90' 90' 90' 90' 74' 16' j6'�0L A
Q I col39 - 38 - 33 - 32 - 27 - 26 - 21 I 204680± SF � 1 4680± SF LO 4680± SF r � - 4680± SF LO 4680± SF r � 4680± SF � 4135± SF -I i 4862± SF
W I I I I I I `$ c_.)
1
I I
x - - P 962E SF _ gp' I I 90' 90' I I 90' 90' I I 90' 80' 1 L J I 82
� I NC) CD I I I I I I I uj I
0LO
I I I I I I I I
1 46'LO
N 40 I _ I 37 _ 34 I _ I 31 _ 28 I _ I 25 _ 22 N W - I
PAE/PUE/EVAE LO4680± SF I I 4680± SF �' 4680± SF I I 4680± SF 4680± SF I I 4680± SF 4160± SF "' r cm n 44939 SF
I
-,5 I I I I I I I
TI
LQ �� I I 90 I I 90 I I 90 I PAE/ UE/EVAE I 81
z� 92' 90' 24' 90' 24' 90' 24' 80' 1 I
-J; � ml I I I I I I I 1 I 'z
PSE/PUE PSE/PUE PSE/PUE - - Ica
- � LO
°'d co EVAE I I EVAE I I EVAE I I M �'LO
U C?11 I 42 L, 41 36 LO 35 I 4950 SF LO 49509 SF I � I 49504 SF 43143 SF I I 18 1
ti I 4996± SF 'n 4950± SF I L I 4950± SF LO 4950± SF I + "' + LO + LO + r�
I (\ `---- 4379± SF 123.0M
�' N x
90'-- 90'--- - -90- -90---- ----90----- .60----72'---- ----- -- 90-- --
Iw
A673' 76 1
LO
�rI1 M I/I
i1N _ =DW r IoO
LLJw STREET 6 �`����� ��z
CL
I 17 I 1�
1 6272± SF x
727' 9' i 24'
8'---54' ---52' -- ---52'-- ---52'--- ---52'-- ---52--- ---52'--- ---52'-- -- 52'-- --52--- --52------52- ----52 ------48" PSE/PUE Ix
3' 5 _ EVAE I I
1
=> N I 100'
CD
co
116.4 rn I x 122.9
x 1 - - - - - - - CD �x
643± SF 4429± SF w 4240 SF 4275 SF 431 4 SF 4346± SF � 438 2 SF � 4417± SF � 445 8 SF 4489 SF 45240 SF 45601 SF 45952 SF 46313 SF 46664 SF 46105 SF
PARCEL B
co 16 0'
(.0 6974± SF I
1 1
8' 55' 52'
52 X52 52' 52' 52' � 52' 52' lix
100' x
52 5252' 52 52' 52'S89°50'14"E 891.40' BNDY � "- " -x
120 / � � � �X � 120.7 x 121.2 x
1�8.0 X - - ,��� 122.1 x 122.2
iX x
X 122.8
CO TA TI-ROHNIr RT PARK UNIFIED SCHOOL DISTRICT
APIA 0 5-250-01 �x
RW
56' ULTIMATE ROW
RW
6'
CITY
FUTURE BY I IMPROVEMENTS BY
OTHERS BRISTOL
C/L
4"PC
C/L
2% 1.5%
AB
4"PCi
C/L
1.5% 2%no_ I no. 2% 1.5%
R/W
Q
6'
1 10'
1
1.5%
2%2°
J
a
U
I
2%
1.5%
10'
10'
1 6'
Z
WH
PARKING
20
O O
I
�-
f-
co
0
EP
_
M1.5%
PAD 4"PCC /4"A
PARKINGI
DRIVE LANE
I
DRIVE LANE
I PARKI
4"PCC/4"AB
3' PUE
5'
5'
---- _-4�_ OO--------
CURB
5'
5'
3' PUE
~0
3' PUE
51
51
32' CURB TO
CURB
tZ
S/W
L/S
L/S
S/W
R/W 1'
PARKING
DRIVE LANE
DRIVE LANE
PARKING
R/W
FC 52' RIGHT OF WAY FC
RESIDENTIAL
RESIDENTIAL
3' PUE
5'
4'
B
32' CURB TO PROPERTY LINE
C
5'
N.T.S.
2„X12„
REDWOOD
S/W
L/S
L/ S
S/W
HEADER
RESIDENTIAL
FC
52' RIGHT OF WAY
FC
RESIDENTIAL
KEISER AVE
STREET
A (EXCLUDING FUTURE
PORTION
N.T.S.
N.T.S.
4"PC
C/L
2% 1.5%
AB
4"PCi
C/L
1.5% 2%no_ I no. 2% 1.5%
R/W
Q
6'
1 10'
1
10'
1 6'
J
a
U
R/W
R/W
6'
10'
10'
1 6'
Z
WH
PARKING
I DRIVE LANE
I
DRIVE LANE
I PARKING
co
0
�(L
O
Z
M
PARKINGI
DRIVE LANE
I
DRIVE LANE
I PARKI
a
a
3' PUE
5'
5'
32' CURB TO
CURB
5'
5'
3' PUE
~0
3' PUE
51
51
32' CURB TO
CURB
tZ
S/W
L/S
L/S
S/W
S/W
L/S
RESIDENTIAL
FC 52' RIGHT OF WAY FC
RESIDENTIAL
RESIDENTIAL
FC 52' RIGHT OF WAY
STREET
B
STREET
C
N.T.S.
N.T.S.
05-01-2018 9:47am Abel Gomez P:\19907\PLN\TM\TM-02-TENTATIVE MAP.DWG
AB
R/W
5' 5' 3' PUE
L/S S/W
FC RESIDENTIAL
-N-
0 20 40 80
SCALE: 1 "=40'
IN
TYPICAL KNUCKLE DETAIL
N.T.S.
NOTES:
1. BOUNDARY IS BASED ON RECORD INFORMATION.
2. FUTURE ROADWAY IMPROVEMENTS ALONG KEISER AVENUE TO
BE CONSTRUCTED BY THE CITY OF ROHNERT PARK.
TCB
2.0'--_I
PUE
I
CONCRETE BAND -\I
20' PRIVATE LANE
ROLLED CURB AND GUTTER
(SEE DETAIL LEFT)
C/L
2%
TYPICAL ALLEY
N.T.S.
TRC
I
12.0'
PUE
I
I
I
3"AC/10"AB
01 Z
PROJECT NO.
19907-00
SHT
2
0 F 6
Q
Z
O
L__
J
a
U
a.
Q
a
c�
Z
WH
>
o
W
Q
co
0
�(L
O
Z
M
W
ma
1
a
a
Z
>Q
a
Z
�/��/�
yr
w
W Z
~0
`W
LL.
O
tZ
U
PROJECT NO.
19907-00
SHT
2
0 F 6
118.4 ^ I I SCALE: 1 =40'
x
x 121.6 I I I 123.6
x
i I
1 I 119.6 x119.1 I x119.. x119.5 I x1 19.5 I 120.4 120.7 122.8
x x x x
118.2 118.7
x \ NUNES TRUST x \ \l \rte TRUST �- I
RAYMOND & I C-1 /VRE HAILrY M011JA1�/MAD � I � OTTER � I r l rc \r I ROBERT �- � � � TRUST
JOHN NUKES JJH11 Nui Es TRUST x 119.7 120 ADA J. Ol ER ° JrLLICL ES I11C, ROB RI' DENIMS VIGIL 1236
18.0 AFN 045-252-011 I APN 045-252-010 I \11ARC1E J,M11\RSHANI I SCHI ETH ET AI I CONNIE ASSA�1 x AP1I1 0415-252-026 I � � APIN 045-252-025 APIA 0415-252-015
x ---------(,x
8.6 AP1\1 045-252-017119.1 AFN OY15-252-�02i1 APIN O415-252-_;,:,-_'- ! x 122.6
121.4
x 118.7 x � 119.9 - - - - - - - 120.8 � - - - - - X �
X_ CONNECT YTO FUTURE x v CONNECT TO FUTURE
S1 FUTURE KEISER
WATER SYSTEM -- -- ------ -�= -_- --- -----. -- ----- --- - --WATER SYSTEM
CONNECT TO FUTURE SD UTILITIES BY OTHERS ---- ------ ----- ------ ------ -- ---- ----- ---- -- ---
i i y. 1 4 120 120.5 20. c 121.2 121.4 121.8 122.4 123 0 1234 1
- - -x - -- - - --- -UT_N; - -mac- x
-------------------------------N -�___ -_-_ -- --CAUTION EXISTING ----12x4------____ -- - - ------------ -_--------------___ ___---------------- __--______ FUTURE KEISER CURB AND -__- ----- ---- --__- __--------------------------�- ..->23.6-----------------------
-� ----- --- SSMH- -- --- ---- --- --- - ---- - ------ -- - --- -- --- ----- --
_...__... _.1. __..._ __.POWER POLE(TYP.) .__...__..."IT_Ry-y�..__... _.._...__...__...__...__...__...__..._ __...__...__.. KEISER_AVENUE __......__ GUTTER BY OTHERS - ---- ---
�- ----- - --- - --- --- - -- -- - ------ --- - -- --- - --- --- - --- --- - --- --- - --- - ---- --- - --- --- - -- --- - --- --- - --- -- ---- --- - --- --- - --- --- - -�-- --- - --- --- - -- --
FT
-- - - --- � ---_ _=U SS --- - --- � -_ __ -_-- __ -_- __ -_- - � -_-- -_ _ -- � -_- __--_- --- � -_- __ -_- _ --- � --
------------------/ -------------- ------------------------------------------------------------------------------------------- - ---
-_z_r=-------=-=----------====;FUT SDS--=-- :z-==--= =---------------------__ -- -- -
. a
----- N89°24'R�'F RA1.44' BNDY
-------- PARCEL C
8.2 } SDCB 1 FH
o�
m 1 0
Q I ro
PARCEL A 39 38 33 32 27 26 21 I SSMH
rn (WATER QUALITY / I I
I I
x 117.8 c� W DETENTION BASIN)-
~ I
1CORY S. CR&I\TH TRUST & \' � - - - - �
I
�i�111�1U' `t L, CF��\TN TRJ57 -w �'
AFN 045-253-007 0
117.6 N� N 3 N -- - -- - -- - 1 -
o 40 1 1 37 34 1 1 31 28 1 1 25 22 1 N 3 I 19 I
-X-C:) IN IN I'n I I
x 117.5 I I c
I I I I I I
SDCB SD SDCB 1 �-
_1 1 - _1 1 - _1 1 _ _ - W: I 'z
DIVERSION In N U, I W' 1 m
I STRUCTURE N N N
42 41 36 35 30 29 1 c:)
Ln o I I 1 I 1 I I 24 23 1 H
N I I I I I U) : 1 18 ,-
I I FH
iIMS
--- - ------SDCB---------SDCB r
- - - - - - - -
FH- - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - - - - - - - - �w
BO FOR FUTURE } SDMH SD SDCB SD SDCB SD SDCB
DEVELOPMENT
SS STUB SSMH STREET B S� SSMH /I �:Z
ss ss ss ss I 17 I
SDCB - - - - - -
-FH-
FH DCB / 1 -
-
---- - - ---- - ---- ---- - - ---- ---- - - ---- ---- - - - - -- - - - -
-- ----------------- - - - - -- -- 1 x
PARCEL B
I� 1 2 3 4 5 6 i 8 9 10 11 12 13 14 15 �x
16 '
I
- --- �- - -- -_ _ _
---+�- -- - � x12
-- -- �---- -- S89050'14"E 891.40' NDY-
120.7 x 121.2 x
COTATI-ROHIN RT PARK UNIFIED SCHOOL DISTRICT
IA 045-25-1-0111 122.1 \ i� 122.8 \
�\ x
AP122.2 x \\
APPROXIMATE LOCATION
OF GOOD NEIGHBOR
FENCING REFER TO
DEVELOPMENT AREA PLAN
-x x x----r_x x x x x----F-x x x�---
w I x
M>< W W W X W,�
H J J J
NOTES:
1. FUTURE ROADWAY IMPROVEMENTS ALONG KEISER AVENUE
TO BE CONSTRUCTED BY THE CITY OF ROHNERT PARK.
2. SIZING OF MAINS TO BE DONE WITH FINAL DESIGN
BASED ON CITY STANDARDS.
R/W
FC
05-01-2018 9:47am Abel Gomez P:\19907\PLN\TM\TM-03-UTILITY PLAN.DIN
UTILITY/TREE LAYOUT - FRONT LOADED PRODUCT
N.T.S.
32' CURB TO CURB
---------------------
16'
TYPICAL 6 -PACK MOTOR COURT
OW SD
7.25'
TYPICAL UTILITY LOCATIONS
N.T.S.
0.75'
N.T.S.
0' Z
=NSION
C -D C.D I.-
N
RWISE
.ANS
m m
W
M o0
z w
z w
w J <U�
W
W
Q U � z
0 U7 0 0 U
Inn
a
QJ
o� o�
Z
O
�� wJ�N
Z
W
Q
O
-N-
�
U
1'
Z
�z oWJo
Q
H
o
0
Y
'^
N ,Z
ERr
W
Ew�
Z
w� �o
>
,L.
O
Z
U
Q
0
1
>
p r
o
0
w
�'�d'
br
P
FC
0 20
40
80
SD
38
fiL
118.4 ^ I I SCALE: 1 =40'
x
x 121.6 I I I 123.6
x
i I
1 I 119.6 x119.1 I x119.. x119.5 I x1 19.5 I 120.4 120.7 122.8
x x x x
118.2 118.7
x \ NUNES TRUST x \ \l \rte TRUST �- I
RAYMOND & I C-1 /VRE HAILrY M011JA1�/MAD � I � OTTER � I r l rc \r I ROBERT �- � � � TRUST
JOHN NUKES JJH11 Nui Es TRUST x 119.7 120 ADA J. Ol ER ° JrLLICL ES I11C, ROB RI' DENIMS VIGIL 1236
18.0 AFN 045-252-011 I APN 045-252-010 I \11ARC1E J,M11\RSHANI I SCHI ETH ET AI I CONNIE ASSA�1 x AP1I1 0415-252-026 I � � APIN 045-252-025 APIA 0415-252-015
x ---------(,x
8.6 AP1\1 045-252-017119.1 AFN OY15-252-�02i1 APIN O415-252-_;,:,-_'- ! x 122.6
121.4
x 118.7 x � 119.9 - - - - - - - 120.8 � - - - - - X �
X_ CONNECT YTO FUTURE x v CONNECT TO FUTURE
S1 FUTURE KEISER
WATER SYSTEM -- -- ------ -�= -_- --- -----. -- ----- --- - --WATER SYSTEM
CONNECT TO FUTURE SD UTILITIES BY OTHERS ---- ------ ----- ------ ------ -- ---- ----- ---- -- ---
i i y. 1 4 120 120.5 20. c 121.2 121.4 121.8 122.4 123 0 1234 1
- - -x - -- - - --- -UT_N; - -mac- x
-------------------------------N -�___ -_-_ -- --CAUTION EXISTING ----12x4------____ -- - - ------------ -_--------------___ ___---------------- __--______ FUTURE KEISER CURB AND -__- ----- ---- --__- __--------------------------�- ..->23.6-----------------------
-� ----- --- SSMH- -- --- ---- --- --- - ---- - ------ -- - --- -- --- ----- --
_...__... _.1. __..._ __.POWER POLE(TYP.) .__...__..."IT_Ry-y�..__... _.._...__...__...__...__...__...__..._ __...__...__.. KEISER_AVENUE __......__ GUTTER BY OTHERS - ---- ---
�- ----- - --- - --- --- - -- -- - ------ --- - -- --- - --- --- - --- --- - --- --- - --- - ---- --- - --- --- - -- --- - --- --- - --- -- ---- --- - --- --- - --- --- - -�-- --- - --- --- - -- --
FT
-- - - --- � ---_ _=U SS --- - --- � -_ __ -_-- __ -_- __ -_- - � -_-- -_ _ -- � -_- __--_- --- � -_- __ -_- _ --- � --
------------------/ -------------- ------------------------------------------------------------------------------------------- - ---
-_z_r=-------=-=----------====;FUT SDS--=-- :z-==--= =---------------------__ -- -- -
. a
----- N89°24'R�'F RA1.44' BNDY
-------- PARCEL C
8.2 } SDCB 1 FH
o�
m 1 0
Q I ro
PARCEL A 39 38 33 32 27 26 21 I SSMH
rn (WATER QUALITY / I I
I I
x 117.8 c� W DETENTION BASIN)-
~ I
1CORY S. CR&I\TH TRUST & \' � - - - - �
I
�i�111�1U' `t L, CF��\TN TRJ57 -w �'
AFN 045-253-007 0
117.6 N� N 3 N -- - -- - -- - 1 -
o 40 1 1 37 34 1 1 31 28 1 1 25 22 1 N 3 I 19 I
-X-C:) IN IN I'n I I
x 117.5 I I c
I I I I I I
SDCB SD SDCB 1 �-
_1 1 - _1 1 - _1 1 _ _ - W: I 'z
DIVERSION In N U, I W' 1 m
I STRUCTURE N N N
42 41 36 35 30 29 1 c:)
Ln o I I 1 I 1 I I 24 23 1 H
N I I I I I U) : 1 18 ,-
I I FH
iIMS
--- - ------SDCB---------SDCB r
- - - - - - - -
FH- - - - - - - - - - - - - - - - - - - - - - - - - - - - --- - - - - - - - - - �w
BO FOR FUTURE } SDMH SD SDCB SD SDCB SD SDCB
DEVELOPMENT
SS STUB SSMH STREET B S� SSMH /I �:Z
ss ss ss ss I 17 I
SDCB - - - - - -
-FH-
FH DCB / 1 -
-
---- - - ---- - ---- ---- - - ---- ---- - - ---- ---- - - - - -- - - - -
-- ----------------- - - - - -- -- 1 x
PARCEL B
I� 1 2 3 4 5 6 i 8 9 10 11 12 13 14 15 �x
16 '
I
- --- �- - -- -_ _ _
---+�- -- - � x12
-- -- �---- -- S89050'14"E 891.40' NDY-
120.7 x 121.2 x
COTATI-ROHIN RT PARK UNIFIED SCHOOL DISTRICT
IA 045-25-1-0111 122.1 \ i� 122.8 \
�\ x
AP122.2 x \\
APPROXIMATE LOCATION
OF GOOD NEIGHBOR
FENCING REFER TO
DEVELOPMENT AREA PLAN
-x x x----r_x x x x x----F-x x x�---
w I x
M>< W W W X W,�
H J J J
NOTES:
1. FUTURE ROADWAY IMPROVEMENTS ALONG KEISER AVENUE
TO BE CONSTRUCTED BY THE CITY OF ROHNERT PARK.
2. SIZING OF MAINS TO BE DONE WITH FINAL DESIGN
BASED ON CITY STANDARDS.
R/W
FC
05-01-2018 9:47am Abel Gomez P:\19907\PLN\TM\TM-03-UTILITY PLAN.DIN
UTILITY/TREE LAYOUT - FRONT LOADED PRODUCT
N.T.S.
32' CURB TO CURB
---------------------
16'
TYPICAL 6 -PACK MOTOR COURT
OW SD
7.25'
TYPICAL UTILITY LOCATIONS
N.T.S.
0.75'
N.T.S.
0' Z
=NSION
C -D C.D I.-
N
RWISE
.ANS
m m
W
M o0
z w
z w
w J <U�
0
W
Q U � z
0 U7 0 0 U
Inn
a
QJ
o� o�
Z
O
�� wJ�N
Z
W
N o�
y
�
U
1'
Z
�z oWJo
Q
H
o
0
Y
'^
N ,Z
ERr
W
Ew�
Z
w� �o
19907-00
SHT
3
OF 6
Q
W
0
H
a
QJ
�a
Z
O
0 }
Z
W
o
�
U
1'
Z
M
d'
H
'^
N ,Z
ERr
W
o
>
,L.
O
r
U
Q
1
>
p r
o
0
�'�d'
br
P
FC
SD
38
fiL
w
SS
a
N
N
Z
J
a
g
W
Z
O
J
U
19907-00
SHT
3
OF 6
Q
W
H
a
QJ
�a
0 }
Z
W
coJ
m�
0
1'
Z
Q
a
H
'^
N ,Z
w
W
o
>
,L.
O
r
U
19907-00
SHT
3
OF 6
x ,
1 I 119.6 x 119.1 I x 119.5
x
x 118.2 x 118.7
JOHIN NUNES TRUST JOHN INUINES TRUST
118.0 APIN 045-252-011 I APIA 0415-252-013
x ---- ----- 118.6
x x 118.7
-x - x X-
--- ----- ----- ----
- - - - 119.3 - 119.4 - - _ 119.6
----- ------ ------ -----
119.41±
-- �, - -- 120-.1
118.6
--- -- 1181±
\ o\° �� 71 ' �
XMl p p 90'
18.2 `I 1 6 ^ D
�1 N 39
x
??7.5 11 .2 `�' Pli�'�
1178 I a x x
x I _ _
117.5 I III_ -P ARCE_L A 90
7 x 117.5
CORY S, CREATH TRUST ?r z
VVINDY L. CREATH TRUST -m
APN 045-253-007
-
M
M
fl -
CID
N
'w
- - - - - - - - -_ "" N
T
0
RA IM OIN D &/-
M,/\RrIE J.RKHAlIM
APN 045-252-017
x 119.1
,LV.✓ ,LV.V
x
CI1\1RE HAIL EY 119.7
SCHL> fH ET AL
AP1N 04/15-252-024
119.9
x 120.4 x 120.7 �-
imOHA>v/]jmAD &
CONNIE ASSA01
/ APN 045-252-023
121.6
x
j
122.8
x
20 AOA J, OTTER I JELLICLES IMC.
x APIA 0415-252-026 AFIN 045-252-025
x 123.6
ROBERT DEININ1S V1G1L TRUST 123.6
AFN 045-252-015
X
123.4 124.6
- -
122.9± 123.6
- ----- -- - ---F--- ------ ----- ------ --- ----- ------ -�---- ---
122.2±
16 o
12--
x
AD
-I
0 20 40 80
iiiii
SCALE: 1 "=40'
2% MIN
HP TYP �
f; If
I I
I I
I I
�I I�
I I
I I
o' Z
fl If yC'
in
�N
w
I I
y
�n =w
w
I x z I AD z z o
I IQ H I
z
R
a
\o R/W
S/W
� Z U
0
I v z _-
STREET
THROUGH FC SLOPE
CURB DRAIN
TYPICAL LOT DRAINAGE
N.T.S.
Y
Q � No
THROUGH w ��
Ezm Yo
CURB DRAIN
Z�
O
Z �p
- - -
8
- - -54' -
- -52' - - - -52'
- - -52 � -
- -52'
o'
- - -52'- -
aa�
- - -52 �- -
- 52'
- 52'
-
- 52 -- - -
- - - 52 1- - -
- - 52 1- - -
-
- -49 -
_'-
-_
CC 4c
�
`/
Y
m m
Q
a
V ♦
w
Z
0
\W
/
m
o0
LL.
O
ItzU
w
48'
v
o f
I
Qu�oou
I
I
AD
I
I
I
I
TYP
I
I
d
13'
�o
fl If yC'
in
�N
w
I I
y
�n =w
w
I x z I AD z z o
I IQ H I
z
R
a
\o R/W
S/W
� Z U
0
I v z _-
STREET
THROUGH FC SLOPE
CURB DRAIN
TYPICAL LOT DRAINAGE
N.T.S.
Y
Q � No
THROUGH w ��
Ezm Yo
CURB DRAIN
Z�
O
Z �p
- - -
8
- - -54' -
- -52' - - - -52'
- - -52 � -
- -52'
- - -52'- -
- -52'
- - -52 �- -
- 52'
- 52'
-
- 52 -- - -
- - - 52 1- - -
- - 52 1- - -
-
- -49 -
_'-
-_
CC 4c
`/
Y
l
Q
a
V ♦
w
Z
0
\W
/
LL.
O
ItzU
48'
v
o f
I
I I
I
I
I
I
I
I
I
I
I
13'
'
6'co
M
PARCEL B-".,<,
M
101,
MIN.
6
116.4
119.7
x
120.0
120.6
120.7
121,
121. 122.1
Q o Q AV
0 1 -
00
2 - 3 -
N M
-
4„ M
2
5 -
-
6 LO
-
7 LO
8 -
9
10
�
x
11
x
12
x
13
14 -
x
15
x
I
122.9 ��
x o sIDE SLOPE
P117.3 CO
P117.7 00 P118.0 °°
P118.3
P118.6
P119.0
P119.3
P119.6
P119.9
P120.2
CID-
P120.5
cy)-
P120.8
P121.1 1L00
P121.4
P121.7
J^
:I
- -
TYPICAL FINISHED LOT GRADING
N.T.S.
p
CO RT PAR} U1�11E1ED Sl OIDISTRICT 122.1 T:122.2 i�_122.8x �\
API�I 045-250-01 3 FENCE ON P/L�
\ X *VERTICAL DIFFERENCE UP
1' I TO 2.5' MAY BE RETAINED
X x / �51
PAD I� WITH A RETAINING WALL
2.2 �\1 1 \, �7 1 1
UNDER FENCE AT P/L
* PAD
TYPICAL REAR/SIDEYARD DETAIL
N.T.S.
P/L R/W P/L
1' 88'± 1' INSTALL FENCE ON LOT P/L
BIORETENTION 6' 4' PARCEL A LINE (TYP) REFER TO LAWRENCE E.
BASIN SIDEWALK PARKWAY SLOPE VARIES
61
INSTALL FENCE ----';'PROPOSED WATER LANDSCAPE PLAN JONES MIDDLE P/L BRISTOL
2% MIN, ON BNDY (TYP) QUALITY / SCHOOL PROPERTY LANDSCAPE
3' PUE 3:1 MAX DETENTION BASIN PAD HINGE 5, R/W
ELEV - 1' MIN 2% 1.0' MIN
3' 12-6 ABOVE 100' WS f - -'- - - - OVERBUILD SLOPE VARIES
OVERBUILD - - - - - - - -MAX WATER SURFACE- - - - 1 OVERBUILD 2 o MIN,
-------------- �iu=in=iii=i=
FUTURE KEISER � - - PAD
- FENCE 3:1 MAX i
IMPROVEMENTS BY y LINE FUTURE KEISER
SLOPE VARIES g 3� r 2% = PROPosFD
OTHERS EXISTING GROUND VARIES IMPROVEMENTS BY -
q �; STREET
(' 1.0' MAX MAXILL
OTHERS
EXISTING GRADE PAD
SLOPE VARIES SD SECTION B -B TYPICAL SIDEYARD/CORNER LOT DETAIL
2% MIN, SECTION C - C SECTION D - D
SECTION A - A 3:1 MAX N.T.S.
N.T.S.
N.T.S. EARTHEN N.T.S.
N.T.S. SWALE
05-01-2018 9:48am Abel Gomez P:\19907\PLN\TM\TM-04-GRADING PLAN.DWG
a.
a
\W
�
a
J
r
�Z
eo
Z
W
CC 4c
`/
Y
Z
Q
a
V ♦
w
Z
0
\W
/
LL.
O
ItzU
'ROJECT NO.
19907-00
SHT
4
0 F 6
J0HIrl IrlUNE S TRUST I JOHN IrlUINr S TRUST I RAYNIOIND �c I CDIVRr NAlI r Y I IYl0HAD &r I ADA J. OTTER Jr I L 1CI r S IINC, I R0Dr RT Dr ININJ3 VJrlL TRUST
API�I 045-252_0"11 ATI 045-252—OJ3 MARG J,]MARKHAIM SCHL ETH ET AL COINIJJr ASSADJ � �5-252-026 A r-2rr_ r , � Ir_r5r_ r
AP1�1 ��� I ���I�J ���� ��� ��� ATI �-�� ��� �1�
AFN 04'--252-01 1 APN 045-252-0'2 APIN 045-252-023
KEISER AVENUE
__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__...__. S89024'36"W 891.44' BNDY
-----------------------------------------
COTAI'JJROH1NrRT PARK UNSCHOOI �1STR1Cr--"—__--_—_—__--_—_—__--__PROPERTY LINE —
STORM WATER CALCULATIONS APIA 045-253-018
STORMWATER TREATMENT AREA
6" GRATE
p
Q
Z
I VF VI
REQUIRED
z 4" PVC
BASIN
EXE
TOTAL
IMPERVIOUS
TREATMENT
AREA
DMA
AREA
AREA
AREA
PROVIDED
1
270,392
158,485
5,050
5,050
STORMWATER TREATMENT AREA
6" GRATE
p
Q
Z
I VF VI
Q a
z 4" PVC
BASIN
EXE
z
` PERFORATED
GROUND
N
IIIIII
a- SUBDRAIN
�
j
Cdw
�P i I-11J�11_I=
=1 1=1 11=1 I I-_
��
I -I 1=1 11-I
LEGEND 1=111=111=1II `L
J
d
=(1�1=111=111=1I 1=
BIORETENTION BASIN
DRAINAGE SHED BOUNDARY
FLOW DIRECTION ARROW
DMA #1 DRAINAGE MANAGEMENT AREA 1
NOTE:
1. INTRACT STORM DRAIN SYSTEM MAYBE
OVERSIZED TO DETAIL EXCESS FLOODS.
DESIGN TO BE REFINED DURING DESIGN.
05-01-2018 9:48am Abel Gomez P:\19907\PLN\TM\TM-0—STORMWATER MGMT PLAN.DWG
_ •1 WNIRA
SANDY LOAM WITH
NATIVE SOIL INFILTRATION RATE
OVERFLOW—"OF 5 IN/HR MIN
6" PIPE
CLASS 2 PERMEABLE MATERIAL
TYPICAL BIO -RETENTION BASIN DETAIL PER CALTRANS SPECIFICATIONS,
SECTION 68.
N.T.S.
SDCB SD (TREATED)
FI=109.7
1117.1± �^
110.5± 118.1±
A �0�
HIGH FLOW --\\,,, �l
BYPASS _ ________
. MAX PARCEL A \ \
+ WATER QUALITY / +
110.5± DETENTION BASIN 110.3±
ISEE SECTION DETAIL, SHEET 5
SDCB WITH [117.1± 01• +10'5±OW
110.
DIVERSION
STRUCTURE
' S� •• I I
.. " -=X-
116.7± x 116.7±
BASIN GRADING PLAN
N.T.S.
FENCE PER
LANDSCAPE PLAN
- I 15'
6" TALL BERM
2:1
MAX
B
117.9±
M
SECTION A -A
N.T.S.
-N-
0 20 40 80
iiia
SCALE: 1 "=40'
W IQ
Z
0
W
0' Z
N `C-D�' a
a
� m m
m o 0
Lj W
W J W
Q U W W =
c� u7 c� c U
Q
Z
d
� m
om
"ov
aJ
J Q
0
U
Z
�
�
Cdw
�
zz
��
!■■ � z
m Q
J
d
Na
�
Z
coo
Z U
O
N O
Y
�
laxN
O
wm
z
Z
w�
�o
0
Q
Z
0
Z
0
�
aJ
J Q
0
M
U
Z
�
�
ER
�
\W
/
Z
�
Q
m
L
CD
�LLJ >
Z
S2w
W
m�
Z
Z
w
0
br
Z
�'
3w
2Z
w
w
/
N
a
co O
W
M
N
Z
U
71)
a
J
a
19907-00
SHT
5
OF 6
Q
Z
0
aJ
J Q
a"
Q
Z
�
a
\W
/
Z
�
Q
m
Q
J
�
OW
Z
S2w
W
m�
Z
0
Y
Z
3w
2Z
W�_
/
Oaf
~
co O
U
19907-00
SHT
5
OF 6
JOHN \l \ Y S - ,I _,
JJH11 11J11��, >'�__ r l
\ I \E, TRUST
JOHN NJ 1-5 fRJ�7Y
1
RAY1��10\U Rr
I I
Cl/�IRr FHA1LrY
1y1JHal�l�lr\D &�
I
r/ OTTER
\>>
IJII
E rI E \r OBE - DENNIS-' Ti
I �Y I
J���l..��� 111.,. �J��R>' ��1I111J ll�I� � r
ail 1
\045-252-011
r\ 5-25�—( 3
1>Jl J D r� ��- J 1 J
NIARGIr J,lY1ARi<HAM
SCHI r7H ET AL
C01\ll\llr ASSADI
/ r\ 045-252-026
>>J11
/ r 045-252-025 A r\ 045-25 -�
aPN >>'1 J J ,� ��H J 1 _-
APivl 045-252-017 �
_AP1v1 045-252-024 �
Al N 045-252-017 �
—APN 045-252-024
� Al N 045-252-02'
1
KEISER AVENUE
_ T
i
I I r:I I
I -I I
TT
F LU
r-1 rl
II
LUId Cc
1
---I I F— ----o
I
J L c
El:
T ,- I- I II I L- I I I F I I I 1
I
L J L -
I I 1
91, I I
1
P.
1
STREET B
I I
1
I ,
-- ---- --- --- ---- ---------
COTATI-ROH1vLRT PARK UNIFIED
SCHOOL DISTRICT
APN 045-353-018
8.8 ft
21.0 ft
18.5 ft
FIRE TRUCK TURNING
1 8.0 ft 1
Fir
e Truck
(c) 2012, Transoft Soluti—
OFT IOFT 20FT
05-01-2018 9:48am Abel Gomez 19907\PLN\TM\TM-06-FIRE PLAN.DWG
i�l;TITza
6.58 21.00
JOHN NUNS TRUST
FIRE TRUCK
feet
Width
8.00
Track
8.20
Lock to Lock Time
6.0
Steering Angle
40.0
TURNING RADIUS*:
INSIDE RADIUS SHALL BE A MINIMUM OF 20 FEET; OUTSIDE RADIUS SHALL
BE A MINIMUM OF 40 FEET, AND SHALL MEET APPROVAL OF THE FIRE
DEPARTMENT. TURNING RADIUS SHALL BE IDENTIFIED ON SUBMITTED SITE
PLANS FOR FIRE DEPARTMENT REVIEW AND APPROVAL (CFC 503.2.4).
*THE TEMPLATE BELOW IS BASED ON THE MINIMUM OUTSIDE TURNING
RADIUS (40'). WHEN THE OUTSIDE RADIUS IS AT THE 40' MIN THE
INSIDE RADIUS MEASURES 23.3', WHICH IS GREATER THAN THE
SPECIFIED 20' MIN. THEREFORE THE TEMPLATE ADHERES TO THE
STANDARD REQUIREMENTS.
I
JOHN NUKES TRUST
JOHN NUNES
I
JOHN NUNS TRUST
I I
RAYNI01\ID &
I I
CL\1Rr HAII rY
I
1�/IOHANINIAD ADA J. OT]'ER
I
r \r r l
JrL L I. L rS IllC, ROBERT DENNIS VIGIL 7RJS1
I
r �
AtJIAl J4�-����OI1
r
A,'N 04�-���-013
r
1J\R�,l� J.l/l,�Rr<H�\lyl
��>-l��l'rl �f ��
(� err
C
.,J1111J� A��A�1 AP1AlJ4�-H��-Or'=;
r �r r rr� r
!'''
AP1V 0�1�-���-0�� A>'1Al Otl�-���'�Ol�
AP
Steering Angle
:32.7
APivl 045-252-017 �
_AP1v1 045-252-024 �
� AP1v1 045-252-023
Z_
COO
W
W
-N-
0 30 60 120
iiiii
SCALE: 1"=60'
KEISER AVENUE
U J w
UJI
cc
I-
I I I
I I I I I I
I I El: I
STREET B
IN Mwid
I I 7
—
, IE L E L E I M M, I 1_J
LF Li�a� i:�7 -:ii7
----------------------------- -- ---- --- i-
- - - L
MATT-ROHNrRT PARK UNITED
SCHOOL DISTRICT
AP\I 045-253-018
6.5 ft
18.3 ft
GARBAGE TRUCK TURNING
10.5 ft V
hull
8.3 ft
Garbage Truck
[ft]
Copyright (c) 2012, Transoft Solutions
OFT 10FT 20FT
6.50 18.30
Q
GARBAGE TRUCK
Z
feet
Width
: 8.30
Track
: 8.30
Lock to Lock Time
:6.0
Steering Angle
:32.7
I IF I
I I 1
I
1
_L_ I
1
1
I I I
I I 1
I ,
I
1
1
�I
I I 1
I 1
W IQ
Z
O
w
01 Z
19907-00
SHT
6
OF 6
Q
Z
O
J
Q
U
0'
Z
Q
J
a
c�
Z_
W
Z
Y
QV
J
0�
Z
S2 W
W
In
I�
Q
Z
Z<
Qa
F—LUOf
Cl)
w
99 w
WO
IY
LL.
O
r
U
19907-00
SHT
6
OF 6
�-----T-I-7-��-T-F-I 1 1 1 1 1 1 I I I
— L _1_ _L —I— —t — L —I— —1 � � � � � —1 — L —I— — — — L — KE/SERA E
I I
i P60SED DEVELOPMENT
II
II
II
- - - - - - - - - - - - - - - - - - ' I
AFFORDABLE W OASIS P014 K LACE
� U W W i
HOUSING Io
/ r4) K W
APARTMENT SITE o o
I
O RYAN ROAD
[ , r I I I I r I I W
r UQ U w
V I-] S r Jl� l- J�lOR fV Q o [ .71 F
0 r-- — — —
Y O J OWEN PLACE W U
O O O O i
Q Q
'C
Au
-J L- -
Vim] 3 r Jr]
KENSINGTON PLACE
KENTON PLACE
J Tradition in Homebuilding
4
0 100 200 400
iiiii
SCALE: 1 "=200'
05-01-2018 9:14am Carrie Wallace P:\19907\PLN\DAP\19907—DAP—OVERALL NEIGHBORHOOD PLAN.DWG
U
Q
0
� KENWOOD PLACE
K 1Yr S r
KENSINGTON PLACE
KENDRA PLACE
OT CE OWEN PLACE
II
I '
KINCADE PLACE KENDAL PLACE
U �
Q
KEATS PLACE Q J
I
W �
� W
J U Q KASEY PLACE W
a O O O
r1Yl1�l = KITE P CE W z
� I
RJ r K3
w w z
Irl �iJi� Y V,1 -13T 0,14K r -I S r
L Jr1r, JL J� I L I
II
KINGWOOD ROAD i KINGWOOD ROAD •
O-- -- -- --
T
1+1 1 - I I - I
— —
_
— Q — r(e-"77
KARENPLACEU
r.S KAI TL YN PLACE •
ROHNERT PARK EXPRESSWAY
LEGEND:
0 SITE LOCATION
o■■■o DAPBOUNDARY
OVERALL SITE PLAN
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.1
MAY 2018
KINCADE PLACE
KEATS PLACE
O
O
W
O
ti
KARLEIGH PLACE
�
Y
O
Cr
KASSIDY PLACE
Vim] 3 r Jr]
KENSINGTON PLACE
KENTON PLACE
J Tradition in Homebuilding
4
0 100 200 400
iiiii
SCALE: 1 "=200'
05-01-2018 9:14am Carrie Wallace P:\19907\PLN\DAP\19907—DAP—OVERALL NEIGHBORHOOD PLAN.DWG
U
Q
0
� KENWOOD PLACE
K 1Yr S r
KENSINGTON PLACE
KENDRA PLACE
OT CE OWEN PLACE
II
I '
KINCADE PLACE KENDAL PLACE
U �
Q
KEATS PLACE Q J
I
W �
� W
J U Q KASEY PLACE W
a O O O
r1Yl1�l = KITE P CE W z
� I
RJ r K3
w w z
Irl �iJi� Y V,1 -13T 0,14K r -I S r
L Jr1r, JL J� I L I
II
KINGWOOD ROAD i KINGWOOD ROAD •
O-- -- -- --
T
1+1 1 - I I - I
— —
_
— Q — r(e-"77
KARENPLACEU
r.S KAI TL YN PLACE •
ROHNERT PARK EXPRESSWAY
LEGEND:
0 SITE LOCATION
o■■■o DAPBOUNDARY
OVERALL SITE PLAN
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.1
MAY 2018
i
5 -,} F
• �y moi. _ �-�..
n A 1Z T n r r c+ Tr1 C T A\/
IAir7Ti A nines
1�
6L
rf_
------------ r T,
. ;7.9
r Zw
T F -F
y I- -I
A Tradition in Homebuilding
05-01-2018 9:12am Carrie Wallace P:\19907\PLN\DAP\19907—DAP—NATURAL RESOURCES EXHIBIT.DWG
4
0 100 200 400
iiii
SCALE: 1 "=200'
._ .., ���NERTPARKEXP t � ��� ��#±� s�1� ta•.:
H
RESSWAY
M
I°
0
J
I
T
� I
I_ I
LEGEND:
NATURAL RESOURCE LOCATIONS
WITHIN UDSP LIMITS
NATURAL RESOURCES PLAN
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.2
MAY 2018
I
JOHN lel U lel r S TRUID r JOHN 1�l J lel r S TRUST RAYMOND r`�r
J J H
r � r I �� � ��l J !� ��� �� J J �l � I ��ilA R r l r J. ��ilA R 1< HA ��il
API�I 045-20'-'2-011I I APN 045-25-2-017
I
CImo\IRE HA1Lr Y I 1\/10HAN1MAD Ar
SCHLrTH ET AI_ I CONNIE ASSADI
APN 045-252-0241 APIA 0415-252-02-3
KEISER AVE.
ADA J. OTTER I Jr I I ICL r S INC.
APIN 04 5-252-026 j APIjN 045-252-025
ROBERT Dr ININ1S VIGIL TRUST
APIN 045-2:'_52-01 J
FUTURE BY I IMPROVEMENTS
OTHERS BY BRISTOL
1.5% 2%
20
L o
J— 1-111=III-11 ° f—
4"PCC /
4"AB
TC=q+.06
20 1.5%
2% f— r
0
4"PCC/
18" LTSG 4 AB
6' 1 10' 1 10' 1 6'
PARKING I DRIVE LANE I DRIVE LANE I PARKING
3' PUE 5' it 14' 1 32' CURB TO PROPERTY LINE 5' 5' 3' PUE
S/W L/S I L/S S/W
RESIDENTIAL FC 52' RIGHT OF WAY FC RESIDENTIAL
R/W R W
STREET A (EXCLUDING FUTURE PORTION
N.T.S.
41��
0 30 N �6T ~0 120
iiii
A Tradition in Homebuildinz SCALE: 1 "=60'
05-01-2018 9:13om Carrie Wallace P:\19907\PLN\DAP\19907—DAP—NEIGHBORHOODPLAN.DWG
4"PCI
C/L
C07ATIJROHIN RT PARK UNIFIED SCHOOL DISTRICT
APN 045-253-01"
2% 1.5%
R/W 6'
PARKING
3' PUE 5' 5'
S/W L/S
FC
10' 10' 6'
DRIVE LANE DRIVE LANE PARKI
32' CURB TO CURB
52' RIGHT OF WAY
STREET B
N.T.S.
AB
R/W
5' 5' 3' PUE
L/S S/W
FC RESIDENTIAL
NOTES:
SEE SHEET C.4 FOR DIMENSIONED SITE
PLAN.
SEE SHEETS C5.1 & C5.2 FOR BRISTOL
NEIGHBORHOOD MINIMUM LOT SETBACKS.
4"PC
C/L
nn 1.5%
_ no.
R/W 6'
PARK:
3' PUE 5' 5'
S/W L/S
—n—K—T A I FC
LEGEND:
PLAN 1 - 11 UNITS
PLAN 2-14 UNITS
PLAN 3-17 UNITS
10' I 10'
VE LANE �T� DRIVE
32' CURB TO CURB
52' RIGHT OF WAY
STREET C
N.T.S.
AB
6' R/W
iKING
5' 5' 3' PUE
L/S S/W
FC RESIDENTIAL
TCB
2.0'�
PUE
I
CONCRETE BAND --\I
20' PRIVATE LANE
ROLLED CURB AND GUTTER
(SEE DETAIL LEFT)
C/L
2%
0
TYPICAL ALLEY
NEIGHBORHOOD PLAN IN D.A.P.
BRISTOL
University Park Specific Plan
Rohnert Park, California
N.T.S.
TRC
I
2.0'
PUE
I
I
3"AC/10"AB
C.3
MAY 2018
I ,
Ai I I RAYMOND ?r
CLAIRE HA1Lr Y MOHAMMAD ?rOTTER� �A J . J r 1 C rS 1 INC. R O D r Rr D ENINl J VIGIL
TRUST
J O-���JNr� rRJ�7 _2�2JOIJO-N NUNES TRUST R1�l O������J01� \ARr,1E J.\ARI<HrM SC�IIrrH ET AL C01�11�1Ir ASSADI ARN 045-252_026 AFIN �5
� �J��JO�!��—�l�l J-_�5 ��A�l�O�f—��J��
KEISER AVE.
- - - - - 62'- - - - -
PARCEL C (LANDSCAPE)
\ \ I 90 ,� 90' 90' i� 90' 90' 20' 90' ^ 74'
\ V28
r22' 10' 22'10i : m10i CM --' ; z i i -- N D i11' 20' r Q 21' D z z I z , cD� z _ ' D - J N z N Q � � Z12�, � r' -i r 18' 1 N21' 10'---- --' 28' 1 1 28' 32 21' o. 28'1 128' ' -- ----' 10' 21 ' I 18,,20
I C4 39 28' 38 33 27 26 M
1 — — PARCEL A� — - 90' so' 90' un so' I I 82' r,
;n 90 ' u > �n 1 1 `-) i� 1 ;n 1
(BASIN) /� I 1 90 �n Ln I 1 s. I
_1 — — — — — 1 8' I 128' 21' 10' 28 28 1 128 , 1 18' 19 I
I I 2
-� 21' ,---- - I 1 25 N 10 , -- - - - -,
-L-1 un F— i N 40 28 28' 37; -- ----, 34 31 I 21 L
LO
�t. w , i T L M N Z N I I
LO
U L� 1 — Q � 20 1 D N Q I 21f I �, z � z 1 z' 10 21' J w 1 z LO
�r J z, LO J 1 1 N ; J 22p 1 , w j ° 22 ' 18' 1 L.LI 1 , 1
U7 —1 � — - i - I � 1 22' ; i 13 10' i 1Lo
20
1 C� -- I 1 1 I I
Q 1 1 90' I I ' 90' I 1 CL -so' I I 90 sIn o 1 C/) 1 81' o
C_.) 1 ..n 921 In 1 1 90 ' �n 1 1 90 1 U J
-n 1
10' 28' 28' 10' 23 18 N I
10' 41 28' 28' 28' 28' 30^-- ---- 29 , 24 21' '--------- LO 22'
I 1 18' I 42 ,---- -- 1 36 cv 35 CO I I T ; "' I 18 -o �1
1 I I -
M r - 1 I D � ¢ II I - � 1 fr zLO
� z I M �'
1 11' z z 1 121' z 10' 21, J 1 1 z LO 10 21' 20 N i Q >, 12 d i z I
I -- uu ' u N
C'' : 22' ; a I I I -- C1 201, 122' i
22I i i i i 18, 1
0'
CD
// ------- -- --90,1 1
o0'- -----I I -90'---o --------- 60'
g0'- - o '26
n o
76' 9o---
72'------- ------ 90'------- o)
LO
/ N
�Jr1
CN� B STREET '1 ,
- - , , D 110',
- -
_ o o 48'- `R=3 17 GJ
- - - - - - - 52' 52 o -52' ^00CD
54'-- -52'- - 52o- - -52 -52'- - -52' N 40'
8 o0 00 --- F 2400 00
0 0
9' 00 00 00 - aF
I�1
100' Lj�n
- - - - - , , 5' 5'
2 ' 7, ' 7 5 7 ---- 7' S 5 9 I 7' 5' 11 '--, 7 5 13 7 14 5' F-1 CD1
'
4 5 �__, 6 --- 7, g -- 7' 10 7' 12 7 15-- 7 39 I
1 i--- 7' , 7' i '
E- - - - - �_ - - �_ - - - - 16
0 0 - , _ c� c� I _ r� v co co coco co co co rn rn i rn r 1
co r
£ Nb� d G NV d 5 5 l Nb� d co
1
5 Z Nb�d £ Nb�d 5' Z Nb�d £ Wd ! , ---£-NV Id Z Wd---£-NV]d Z NVId Z NV�d £ Nb�d Z N`dld G NV]d z
5 - �. ---- 7 ------ ------ r—�----
N
-- 55- -- 52_ �- -� 52 -- -
— A Tradition in Homebuilding —
05-01-2018 9:06am Carrie Wallace P:\19907\PLN\DAP\19907-DAP-DIMENSIONEDSITEPLAN.DWG
0 30 60
0011111111111
SCALE: 1 "=30'
�r-
N
- 52 - - -�
52 --�
- - � 52' - � - 52'
NOTE:
SEE SHEETS G3.1 & G3.2 FOR
BRISTOL NEIGHBORHOOD MINIMUM
LOT SETBACKS.
Ln
52
i�
N
-52 --�
COTA71-RONNrR7 PARK UNIFIED SCHOOL DISTRICT
ARM 045-25-3-0 1 8
LEGEND:
PLAN 1 - 11 UNITS
PLAN 2-14 UNITS
PLAN 3-17 UNITS
00
N N
52 - - - - 52 - -
- - 52 -
0
-� 52 -��
52'
C')
' 10' 1
� 1
rn -
1
-� -- 100'
DIMENSIONED SITE PLAN
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.4
MAY 2018
J Tradition in Homebuilding
KEISER AVENUE
0 5 10 20
SCALE. 1 "=10'
05-01-2018 9:10am Carrie Wallace P:\19907\PLN\DAP\19907—DAP—MIMIMUMSETBACK.DWG
NOTES:
A. SEE LANDSCAPE PLANS FOR DETAILED LOCATIONS OF DRIVEWAYS, PATHWAYS AND LANDSCAPING AND FENCING.
B. SEE ARCHITECTURE PLANS FOR DETAILED FLOOR PLANS AND ELEVATIONS.
C. GARBAGE CANS WILL BE STORED BEHIND FENCES, OR IN GARAGES UNTIL PICKUP WHERE THEY WILL BE MOVED TO THE STREET FOR PICKUP.
D. *DRIVEWAYS TO BE 18' MINIMUM FROM CURB
MINIMUM SETBACK EXHIBIT
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.5.
MAY 2018
— 4 7 radition in Homebuilding
05-01-2018 9:1 lam Carrie Wallace P:\19907\PLN\DAP\19907—DAP—MIMIMUMSETBACK.DWG
5 10
NOTES:
A. SEE LANDSCAPE PLANS FOR DETAILED LOCATIONS OF DRIVEWAYS, PATHWAYS AND LANDSCAPING AND FENCING.
B. SEE ARCHITECTURE PLANS FOR DETAILED FLOOR PLANS AND ELEVATIONS.
C. GARBAGE CANS WILL BE STORED BEHIND FENCES, OR IN GARAGES UNTIL PICKUP WHERE THEY WILL BE MOVED
TO THE STREET FOR PICKUP.
MINIMUM SETBACK EXHIBIT
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.5.2
MAY 2018
JJHIrl NUNrS TRUST
APN 045-252-011
TRUST I RAY1NIJIrlD r`�r I C1��1Rr HAI r Y NIJi lAININIAD -Ar
JOHN Irl U Irl r S r � � r � r- � C � Irl Irl l r A JJA D l
I INIARGIr J.MARIMHAINI I SCHI rT l r r AI r rr r
APIA 045-252-013
API�I J�i5-252JJ"l7 ARM J%i5-252JJ2�f I API\I J%!� 2��-J�3
KEISER AVE.
I I
I I
A A �r� J Or-rr R
Jr I I ICI r S IINC.
I
I
I RJDr R7
DENNIS VR]IL TRUST
. �� I
I �PN JZr5J25-2-026
APN 045-252-025
APN
045-252-015
05-01-2018 9:15om
A Tradition in Homebuilding
Carrie Wallace P:\19907\PLN\DAP\19907—DAP—PARKINGPLAN.DWG
CJ7A71-RONNrR7 PARK UNIFIED SCHOOL DISTRICT
API11 0415-2 3)-018
PARKING PROVIDED FOR GEE PROPERTY:
RESIDENTIAL PARKING (IN GARAGE) :
RESIDENTIAL VISITOR PARKING (IN DRIVEWAY):
° 30 60 ON STREET VISITOR PARKING:
SCALE: 1"=30' TOTAL PARKING:
84 SPACES
84 SPACES
45 SPACES
213 SPACES
LEGEND:
0 PARKING SPACE (8'x 22')
FH FIRE HYDRANT
PARKING PLAN
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.6
MAY 2018
I I
I I
I I
II JOHN uU er S TRUST II RAYMOND ?r II CLAIRE -AIL r Y
JANeuJlerS TRUST APlel J��SJ 2S —J l3 MARGIr J,MARKHAM SCkIrr-rr AL
APJN 045JX52 011 APN 0-r-252—JI� APJN 045-252-0
2
4
KEISER AVE.
I
I
lelJSIAMMAD ADA J. OTT E R
CJNJNIr ASSADI I APN 045-252J026
APIA 0415 -252 -02 -
Jr I I ICL rS IINC.
APN 045-252-025
ROBERT DENNIS VIC L TRUST
APN 045-252-015
05-01-2018 9:07am
-4 Tradition in Homebuilding
Carrie Wallace P:\19907\PLN\DAP\19907—DAP—GARBAGEPLAN.DWG
CJ Tri H—HU1-1IN h J UNJJ Jr J vDl--JUUL UJv J NJ: -1 WNE • " I 11 1ML-1°il-1111
■ TRASH AND RECYCLING BIN LOCATIONS WITHIN
PUBLIC STREETS FOR PICKUP
GARBAGE PICKUP PLAN
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.7.1
MAY 2018
O.. -,ter..,..,,,., d`ciLEGEND n,..,,,.__...,,,�.,�..............._,..,.,.�,,.,.._,,.., GARBAGE STORAGE LOCATIONS C.7.2
— A Tradition in Homebuilding
05-01-2018 9:08am
Carrie Wallace P:\19907\PLN\DAP\19907—DAP—GARBAGEPLAN.DWG
<V
0 5 10 20
SCALE: 1 "=10'
ON -LOT TRASH & RECYCLING BIN STORAGE LOCATION
BEHIND SIDE YARD FENCE
TRASH AND RECYCLING BIN LOCATIONS WITHIN
PUBLIC STREETS FOR PICKUP
BRISTOL
University Park Specific Plan
Rohnert Park, California
MAY 2018
JOHN NUNrS TRUST
APN 045-252-011
I
I I
RAYMOND r`�r I CIA\lRr HAlI r Y �MOHAMi\/IAD r`�r ADA J. OTTr R
JOHN NUNrS TRUST r Sr r- H r- � CJlellellr ASSADl �045-252-026
r Jr rr – f r
� � �� � – � � � � � . r, J�/lA R r1 r J .1�ilAR 1<HAl�il �,.>-1 I r_ r H r r A I I ., APN lel cif � � � �
APS 1 J f5 �5� J 1
APN 045-252-017 I AP.N 045-252-024 APN 045-252-023
-- - - - - - KEISER AVE.
Jr IICI rS INC.
APN 045-25`2-025
ROBERT DENNIS VIGIL TRUST
APIN 045-252-015
— — — — — — — — — I -- — — — —
05-01-2018 9:09am
14 Tradition in Homebuilding
Carrie Wallace P:\19907\PLN\DAP\19907—DAP—MAILBOXPLAN.DWG
4
0 30 60
SCALE: 1 "=30'
CJTATI–ROHN RT PARK UNIFIED SCHOOL DISTRICT
APN Oji 5– 2530- "10
LEGEND
PRELIMINARY MAILBOX LOCATIONS
(FINAL LOCATIONS SUBJECT TO USPS
APPROVAL)
I I lV V i VL V I %J VVVI l \,A/ Al M%A IVI/ \i LVV/\VV I VI I I I IL
BRISTOL PROPERTY WITHIN THE PROJECT. TO BE
LOCATED IN THE PARKWAY STRIP BETWEEN THE
CURB AND THE SIDEWALK AND FACE OUT ONTO THE
SIDEWALK.
MAILBOX LOCATION PLAN
BRISTOL
University Park Specific Plan
Rohnert Park, California
C.8
MAY 2018
LANDSCAPE PLANS FOR:
1ST LAND DEVELOPMENT PHASE
BRISTOL SUBDIVISION, KEISER AVENUE FRONTAGE
ROHNERT PARK, CALIFORNIA
APRIL 26, 2018
VICINITY MAP
SITE MAP
TABLE OF CONTENTS
COVER SHEET
LANDSCAPE MASTER PLAN
FRONT & SIDE YARD TYPICAL SIX PACK LOT LANDSCAPE PLANS
PEDESTRIAN CONNECTION TO KEISER AVENUE AND
FRONT & SIDE YARD TYPICAL IN-LINE LOT LANDSCAPE PLANS
FRONT & SIDE YARD ATYPICAL IN-LINE LOT LANDSCAPE PLANS
DETENTION BASIN ENLARGEMENT AND WATER USE CALCULATIONS
LANDSCAPE DETAILS
L-1.0
L-1.1
L-1.2
L-1.3
L-1.4
L-1.5
L-1.6
I�NAT vanderToolen • Associates www.vanderToolen.com
Napa Walnut Creek West Sacramento
855 Bordeaux 700 Yguacio Valley 2101 Stone Blvd.
Development Area Plan B R Landscape Cover Sheet ..// W
�I
Way, Suite Walnut
reek, A Suite 11L5
•
4670 Willow Rd Suite 200 R `, ���j��t ����_ -� Napa, 58 Walnut Creek, CA W Sacramento,
��" '7� i„ 94596 CA 95691
Pleasanton, CA 94588 yill��,ti� 1e1: 707.224.2299 tel: 925.274.1305 tel: 916.244.3000
Phone (925) 463-1122 R o h n e rt Park, California LANDSCAPE ARCHITECTS -707.224.682l Scale: Not Applicable APRIL 26, 2018 Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
TUBULAR STEEL GATE.
SEE DETAIL F, SHEET L-1.6.
PRECAST SPLIT RAIL FENCE.
SEE DETAIL E, SHEET L-1.6.
DETENTION BASIN - SEE
ENLARGED PLAN, SHEET L -t5
IGNATUIW,,
4670 Willow Rd Suite 200
Pleasanton, CA 94588
Phone (925) 463-1122
7,kf AM T fm' 1
PEDESTRIAN CONNECTION TO KEISER
AVENUE - SEE ENLARGED PLAN, SHEET L-1.3.
MM1r%Tr%1
0 NTS
EMr%K1T 01MM VA MM 4 1l0I0CM A%ICAII IC
TREE NOTE
DETENTION
BASIN PLANT PALETTE
PLANT
PALETTE
* PLANT MATERIALS PURSUANT TO THE
NCRWQCB
PLANT PALETTE.
TREE LOCATION.
BOTANICAL NAME
COMMON NAME
SPACING
CONTAINER SIZE
BOTANICAL NAME
TREES
WATER USE
—
TREES
HETEROMELES ARBUTIFOLIA
TOYON
15' O.C.
15 GAL
�-
SHRUBS & GROUNDCOVERS
1
1 2
3 L
RHAMNUS CALIFORNICA
COFFEEBERRY WILD
6' O.C.
ROSE POTS
8
ROSA CALIFORNICA
ROSE
6' O.C.
ROSE POTS
PLANTS WILL BE GROUPED ONTO SEPARATE VALVES ACCORDING TO SUN
DESCHAMPSIA CESPITOSA
HAIR GRASS PURPLE
3' O.C.
PLUGS
MARINA STRAWBERRY TREE
NASSELLA PULCHRUM
NEEDLE GRASS
2' O.C.
PLUGS
WESTERN REDBUD
ESCHSCHOLZIA CALIFORNICA
CALIFORNIA POPPY
2' O.C.
PLUGS
PURPLE LEAF PLUM
LEYMUS TRITICOIDES
WILDRYE
3'0.C.
PLUGS
BROMUS CARINATUS
CALIFORNIA BROME
2' O.C.
PLUGS
PURPLE HOPSEED BUSH
SISYRINCHIUM BELLUM
BLUE-EYED GRASS
1' O.C.
PLUGS
PINEAPPLE GUAVA
HORDEUM BRACYANTHERUM
BARLEY
+ +
HYDROSEED
NEW ZEALAND FLAX
LOW
5 GAL
+
100%
CAROLINA CHERRY
SEED MIX OF:
5 GAL
HYDROSEED
CLARA INDIAN HAWTHORN
BROMUS CARINATUS
CALIFORNIA BROME
30%
SHINY XYLOSMA
SISYRINCHIUM BELLUM
BUTTERCUP BLUE-EYED GRASS
30%
CISTUS SPP.
TRIFOLIUM WILDENOVII
TOMCAT CLOVER
5 GAL
30%
COLEONEMA SPP.
VULPIA MICROSTACHYS
THREE-WEEK FESCUE
5 GAL
10%
ESCALONIA FRADESII
FRADESI ESCALONIA
MODERATE
5 GAL
LOROPETALUM 'RAZZLEBERRI'
FRINGE FLOWER
LOW
5 GAL
EMr%K1T 01MM VA MM 4 1l0I0CM A%ICAII IC
Development Area Plan
BRISTOL
Rohnert Park, California
TREE NOTE
1. THE LOCATION AND QUANTITY OF TREES IS SUBJECT TO
PLANT
PALETTE
17
TREE LOCATION.
2. PROVIDE 3' CLEAR AROUND ALL HYDRANTS PER
SYMBOL
BOTANICAL NAME
CALIFORNIA FIRE CODE.
WATER USE
—
TREES
INDEPENDENT TIMING OF INDIVIDUAL IRRIGATION SYSTEMS. THE
STREET TREES
�-
1
1 2
3 L
4
M- F
5 L
6
117
PF
8
9 L
10I
Development Area Plan
BRISTOL
Rohnert Park, California
FRONT, SIDE YARD & PARKWAY TYPICAL LANDSCAPE,
IN-LINE LOTS - SEE ENLARGED PLAN, SHEET L-1.3.
Landscape Master Plan
I
vanderToolen • Associates
i
LANDSCAPE ARCHITECTS
TREE NOTE
1. THE LOCATION AND QUANTITY OF TREES IS SUBJECT TO
PLANT
PALETTE
CHANGE BASED ON UTILITY COMPOSITION AND STREET
TREE LOCATION.
2. PROVIDE 3' CLEAR AROUND ALL HYDRANTS PER
SYMBOL
BOTANICAL NAME
CALIFORNIA FIRE CODE.
WATER USE
FRONT, SIDE YARD & PARKWAY TYPICAL LANDSCAPE,
IN-LINE LOTS - SEE ENLARGED PLAN, SHEET L-1.3.
Landscape Master Plan
I
vanderToolen • Associates
i
LANDSCAPE ARCHITECTS
www.vanderTooIen.com
Napa Walnut Creek West Sacramento
855 Bordeaux 700 Ygnacio Valley 2101 Stone Blvd.
Way, Suite 240 Rd. Suite 100 Suite 115
Napa, CA Walnut Creek, CA W. Sacramento,
94558 94596 CA 95691
tel: 707.224.2299 tel: 925.274.1305 tel: 916.244.3000
rax: 707.224.6821
IRRIGATION CONCEPT
STATEMENT
PLANT
PALETTE
THE IRRIGATION DESIGN FOR THE SITE SHALL COMPLY WITH THE STATE
OF CALIFORNIA MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (TITLE
MIN.
SYMBOL
BOTANICAL NAME
COMMON NAME
WATER USE
SIZE
TREES
INDEPENDENT TIMING OF INDIVIDUAL IRRIGATION SYSTEMS. THE
STREET TREES
CONTROLLER WILL HAVE A 24-HOUR CLOCK TO ALLOW MULTIPLE START
TIMES AND REPEAT CYCLES TO ADJUST FOR SOIL PERCOLATION RATES.
x
LIRIODENDRON TULIPFERA
TULIP TREE
MODERATE
24" BOX
LOW FLOW BUBBLERS FOR TREES AND POINT SOURCE DRIP IRRIGATION
PISTACIA CHINENSIS
CHINESE PISTACHE
LOW
24" BOX
SECONDARY FRONT YARD TREES
PLANTS WILL BE GROUPED ONTO SEPARATE VALVES ACCORDING TO SUN
EXPOSURE AND WATER USE TO ALLOW FOR IRRIGATION APPLICATION BY
ARBUTUS 'MARINA'
MARINA STRAWBERRY TREE
LOW
15 GAL
'
CERCIS OCCIDENTALIS
WESTERN REDBUD
VERY LOW
15 GAL
PRUNUS C. 'KRAUTER VESUVIUS'
PURPLE LEAF PLUM
LOW
15 GAL
FRONT & SIDE
YARD PLANTING
LARGE SHRUBS
DODONAEA VISCOSA
PURPLE HOPSEED BUSH
LOW
5 GAL
FEIJOA SELLOWIANA
PINEAPPLE GUAVA
LOW
5 GAL
+ +
PHORMIUM 'GUARDSMAN'
NEW ZEALAND FLAX
LOW
5 GAL
+
PRUNUS CAROLINIANA
CAROLINA CHERRY
LOW
5 GAL
RHAPHIOLEPIS I. 'CLARA'
CLARA INDIAN HAWTHORN
MODERATE
5 GAL
XYLOSMA CONGESTUM
SHINY XYLOSMA
LOW
5 GAL
MEDIUM SHRUBS
CISTUS SPP.
ROCKROSE
LOW
5 GAL
COLEONEMA SPP.
BREATH OF HEAVEN
MODERATE
5 GAL
O
ESCALONIA FRADESII
FRADESI ESCALONIA
MODERATE
5 GAL
LOROPETALUM 'RAZZLEBERRI'
FRINGE FLOWER
LOW
5 GAL
NANDINA DOMESTICA
HEAVENLY BAMBOO
LOW
5 GAL
PHORMIUM SPP.
NEW ZEALAND FLAX
LOW
5 GAL
PITTOSPORUM SPP.
TOBIRA
LOW
2 GAL
ROSA CALIFORNICA
WILD ROSE
LOW
5 GAL
SALVIA SPP.
ORNAMENTAL SAGE
MODERATE
5 GAL
VIBURNUM SPP.
VIBURNUM
MODERATE
5 GAL
WESTRIGIA FRUTICOSA
COAST ROSEMARY
LOW
5 GAL
SMALL SHRUBS
ANIGOZANTHOS SPP.
KANGAROO PAW
LOW
1 GAL
�'
DIETES BICOLOR
FORTNIGHT LILY
LOW
1 GAL
•
•
HEMEROCALLIS SPP.
EVERGREEN DAYLILY
MODERATE
1 GAL
•�
PENSTEMON SPP.
GARDEN PENSTEMON
MODERATE
1 GAL
PHORMIUM SPP.
NEW ZEALAND FLAX
LOW
1 GAL
SOLLYA HETEROPHYLLA
AUSTRALIAN BLUEBELL
LOW
1 GAL
GRASSES
CALAMAGROSTIS 'KARL FOERSTER'
FEATHER REED GRASS
LOW
1 GAL
FESTUCA MAIREI
HELICTOTRICHON SEMPERVIRENS
ATLAS FESCUE
BLUE OAT GRASS
LOW
LOW
1 GAL
1 GAL
LEYMUS'CANYON PRINCE'
BLUE WILD RYE
VERY LOW
1 GAL
MUHLENBERGIA RIGENS
DEER GRASS
LOW
1 GAL
PENNISETUM ORIENTALE
FOUNTAIN GRASS
LOW
1 GAL
STIPA ARUNDINACEA
PHEASANT GRASS
VERY LOW
1 GAL
GROUNDCOVERS
ARCTOSTAPHYLOS'EMERALD CARPET' MANZANITA
VERY LOW
1 GAL
HELIANTHEMUM NUMMULARIUM
SUNROSE
LOW
1 GAL
C,—D
MYOPORUM PARVIFOLIUM
PROSTRATE MYOPORUM
LOW
1 GAL
ROSMARINUS 'HUNTINGTON CARPET' DWARF ROSEMARY
LOW
1 GAL
SCAEVOLA WAUVE CLUSTERS'
PURPLE SCAEVOLA
LOW
1 GAL
VINES
,,,,,r,,,,,,
PARTHENOCISSUS TRICUSPIDATA
BOSTON IVY
MODERATE
5 GAL
www.vanderTooIen.com
Napa Walnut Creek West Sacramento
855 Bordeaux 700 Ygnacio Valley 2101 Stone Blvd.
Way, Suite 240 Rd. Suite 100 Suite 115
Napa, CA Walnut Creek, CA W. Sacramento,
94558 94596 CA 95691
tel: 707.224.2299 tel: 925.274.1305 tel: 916.244.3000
rax: 707.224.6821
GOOD NEIGHBOR FENCE & GATE (TYP.) -
SEE DETAILS B & C, SHEET L-1.6.
(3) 16 BOX CBU LOCATED IN PARKWAY. MAILBOX
UNITS SHALL BE (3) 4C15D-16P; COLOR: 'BLACK' -
SEE DETAIL I, SHEET L-1.6.
FRONT, SIDE YARD & PARKWAY TYPICAL LANDSCAPE,
ATYPICAL LOTS - SEE ENLARGED PLAN, SHEET L-1.4.
0' 20' 40' 80' 160'
Scale: 1 " = 40'-0"
APRIL 26, 2018 1 NORTH I Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
IRRIGATION CONCEPT
STATEMENT
THE IRRIGATION DESIGN FOR THE SITE SHALL COMPLY WITH THE STATE
OF CALIFORNIA MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (TITLE
23 - DIVISION 2 -CHAPTER 2.7)
THE IRRIGATION SYSTEMS WILL BE AUTOMATICALLY CONTROLLED BY AN
ET IRRIGATION CONTROLLER CAPABLE OF MULTIPLE PROGRAMMING AND
INDEPENDENT TIMING OF INDIVIDUAL IRRIGATION SYSTEMS. THE
CONTROLLER WILL HAVE A 24-HOUR CLOCK TO ALLOW MULTIPLE START
TIMES AND REPEAT CYCLES TO ADJUST FOR SOIL PERCOLATION RATES.
THE IRRIGATION SYSTEMS WILL CONSIST PRIMARILY OF LOW VOLUME,
LOW FLOW BUBBLERS FOR TREES AND POINT SOURCE DRIP IRRIGATION
FOR SHRUBS AND GROUNDCOVERS.
PLANTS WILL BE GROUPED ONTO SEPARATE VALVES ACCORDING TO SUN
EXPOSURE AND WATER USE TO ALLOW FOR IRRIGATION APPLICATION BY
HYDROZONE. THE IRRIGATION SCHEDULING WILL REFLECT THE REGIONAL
EVAPO-TRANSPI RATION RATES. THE ENTIRE SITE WILL BE DESIGNED TO
RUN DURING NIGHTTIME HOURS WHEN IRRIGATION IS MOST EFFICIENT.
IF RECYCLED WATER MAIN IS INSTALLED ALONG KEISER ROAD,
IRRIGATION SYSTEM WILL CONNECT TO IT.
GOOD NEIGHBOR FENCE & GATE (TYP.) -
SEE DETAILS B & C, SHEET L-1.6.
(3) 16 BOX CBU LOCATED IN PARKWAY. MAILBOX
UNITS SHALL BE (3) 4C15D-16P; COLOR: 'BLACK' -
SEE DETAIL I, SHEET L-1.6.
FRONT, SIDE YARD & PARKWAY TYPICAL LANDSCAPE,
ATYPICAL LOTS - SEE ENLARGED PLAN, SHEET L-1.4.
0' 20' 40' 80' 160'
Scale: 1 " = 40'-0"
APRIL 26, 2018 1 NORTH I Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
•X•
El
2
•
IGNATUW,,
4670 Willow Rd Suite 200
Pleasanton, CA 94588
Phone (925) 463-1122
Lot 27 L- -- •
Plan 2
OvvO�
.A
------
J
Lot 28
Plan 1 '
I
I
K1
Lot 29
Plan 3
• l�•1.')( •
Development Area Plan
JUU
v
r
J
0
E:3
1
10
upon
�v.
N
RIVIhm"411,04F
Lot 26
Plan 1
�_
I
L---- ------- I
Lot 25
Plan 3
---. .. Lot 24
Plan 2
• ♦ ♦ ♦— — — — — — —
o ' I
I
BRISTOL
Rohnert Park, California
2
•] • C9X61 • �•Y•l •
MIMIN
Typical Six -Pack Front, Side
Yard & Parkway, Keiser
Avenue Frontage Landscape
vanderToolen • Associates
V)��+l
Napa
Bordeaux
Walnut Creek
700 Valley
West Sacramento
2101 Stone Blvd.
Way, Suite 240
ay,
Rd. Suite
Rd. Suite 100
Suite 115
0WOW
Napa, CA
94555
Walnut Creek, CA
94596
W Sacramento,
CA 95691
tel 707.224.2299
tel: 925.274.1305
tel: 916.244.3000
P_
fax:707.224.6821
-
-
-
-
-
-
---. .. Lot 24
Plan 2
• ♦ ♦ ♦— — — — — — —
o ' I
I
BRISTOL
Rohnert Park, California
2
•] • C9X61 • �•Y•l •
MIMIN
Typical Six -Pack Front, Side
Yard & Parkway, Keiser
Avenue Frontage Landscape
vanderToolen • Associates
www.vanderToolen.com
Napa
Bordeaux
Walnut Creek
700 Valley
West Sacramento
2101 Stone Blvd.
Way, Suite 240
ay,
Rd. Suite
Rd. Suite 100
Suite 115
0WOW
Napa, CA
94555
Walnut Creek, CA
94596
W Sacramento,
CA 95691
tel 707.224.2299
tel: 925.274.1305
tel: 916.244.3000
LANDSCAPE ARCHITECTS
fax:707.224.6821
DESIGN CALLOUTS
O1 PRIVATE ENTRY CONCRETE WALK -SEE DETAIL A, SHEET L-1.6
O2 WOOD GOOD NEIGHBOR FENCE -SEE DETAIL B, SHEET L-1.6
O3 WOOD GOOD NEIGHBOR GATE -SEE DETAIL C, SHEET L-1.6
O4 ACOUSTIC GOOD NEIGHBOR FENCE -SEE DETAIL D, SHEET L-1.6
O5 PRIVATE YARD LANDSCAPING PER HOMEOWNER
O6 FRONT &SIDE YARD PLANTING AREA
O7 PUBLIC SIDEWALK
O8 PRIVATE CONCRETE DRIVEWAY
O9 FRONT YARD ACCENT TREE
10 STREET TREE
11 PARKWAY PLANTING
12 PRECAST CONCRETE FENCE -SEE DETAIL E, SHEET L-1.6
13 GATE AT PRECAST CONCRETE FENCE -SEE DETAIL F, SHEET L-1.6
14 CONCRETE WALK -SEE DETAIL A, SHEET L-1.6.
0' 5' 10' 20' 40'
Scale: 1" = 10'-0" APRIL 26, 2018
j L�l 02
NORTH Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
PEDESTRIAN CONNECTION TO KEISER AVENUE 0
FRONT, SIDE YARD & PARKWAY TYPICAL LANDSCAPE, IN-LINE LOTS \W
DESIGN CALLOUTS
O1 PRIVATE ENTRY CONCRETE WALK -SEE DETAIL A, SHEET L-1.6
O2 WOOD GOOD NEIGHBOR FENCE -SEE DETAIL B, SHEET L-1.6
O3 WOOD GOOD NEIGHBOR GATE -SEE DETAIL C, SHEET L-1.6
O4 ACOUSTIC GOOD NEIGHBOR FENCE -SEE DETAIL D, SHEET L-1.6
O5 PRIVATE YARD LANDSCAPING PER HOMEOWNER
O6 FRONT &SIDE YARD PLANTING AREA
O7 PUBLIC SIDEWALK
O8 PRIVATE CONCRETE DRIVEWAY
O9 FRONT YARD ACCENT TREE
10 STREET TREE
11 PARKWAY PLANTING
12 PRECAST CONCRETE FENCE -SEE DETAIL E, SHEET L-1.6
13 GATE AT PRECAST CONCRETE FENCE -SEE DETAIL F, SHEET L-1.6
14 CONCRETE WALK -SEE DETAIL A, SHEET L-1.6.
I�N� vanderToolen •Associates www.vanderToolen.com o' 5' 10, 20' 40'
NORTH
W,,,
Napa
a a Walnut Creek West Sacramento
NORTH
Front Side Yard 855 Bordeaux 700 Ygoacio Valley 2101 Stone Blvd. SEE PLA
N
6Way, Suite Rd. Suite 100 Suite 115
L�l ■3
U Development Area Plan Napa, CA walnut Creek, CA W. Sacramento,
4670 Willow Rd Suite 200BRISTOL ParkwayLandsca e 94558 94596
CA 95691
Pleasanton, CA 94588tel: 707.224.2299 tel: 925.274.1305 tel: 916.244.3000
Phone (925) 463-1122 R o h n e rt Park, California LANDSCAPE ARCHITECTS la,:707,224,6821 Scale: 1= 10'-0't APRIL 26, 2018 Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
FRONT, SIDE YARD & PARKWAY TYPICAL LANDSCAPE, ATYPICAL LOTS
DESIGN CALLOUTS
PRIVATE ENTRY CONCRETE WALK - SEE DETAIL A, SHEET L-1.6
WOOD GOOD NEIGHBOR FENCE - SEE DETAIL B, SHEET L-1.6
WOOD GOOD NEIGHBOR GATE - SEE DETAIL C, SHEET L-1.6
ACOUSTIC GOOD NEIGHBOR FENCE -SEE DETAIL D, SHEET L-1.6
PRIVATE YARD LANDSCAPING PER HOMEOWNER
O6 FRONT &SIDE YARD PLANTING AREA
O7 PUBLIC SIDEWALK
PRIVATE CONCRETE DRIVEWAY
FRONT YARD ACCENT TREE
10 STREET TREE
11 PARKWAY PLANTING
12 PRECAST CONCRETE FENCE -SEE DETAIL E, SHEET L-1.6
13 GATE AT PRECAST CONCRETE FENCE -SEE DETAIL F, SHEET L-1.6
14 CONCRETE WALK -SEE DETAIL A, SHEET L-1.6.
IGN�W,,, vanderToolen • Associates www.vanderToolen.com 0' 5' 10' 20' 40'
Atypical Lot Front, Side Yard Napa Walnut Creek West Sacramento
ay, Bordeaux 700 Rd. So Valley 2101 Stone Blvd.
4
Development Area Plan BRISTOL�� ���
4670 Willow Rd Suite 200� ����E� _ -._ wav,S"'94i58 Rd. s 94196 A956 1 L�l ■
Napa, CA Walnut Creek, CA W. Sacramento,
& Parkway Landscape � � � � 9496 CA 95691
Pleasanton, CA 94588tel: 707.224.2299 tel: 925.274.1305 tel: 916.244.3000
Phone (925) 463-1122 R o h n e rt Park, California LANDSCAPE ARCHITECTS fax: 707.224.6821 Scale: 1 " = 10'-0" APRIL 26, 2018 NORTH Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
BASIN PERSPECTIVE- DRAWING NOT TO SCALE
IGNATUW,,
4670 Willow Rd Suite 200
Pleasanton, CA 94588
Phone (925) 463-1122
Development Area Plan
BRISTOL
Rohnert Park, California
Use drop down menus or type in values in white cells only. Results appear in Yellow or Red highlighted cells below.
Information
Site Name ->I Bristol
SiteType->J Residential
Annual Eta (inches/yr) 4 1 42
Allowed ETAF:1 0.55
Water Efficient
Landscape Worksheet
Adapted from California Code
of Regulations Title 23,
Division 2, Chapter 2.7. Model
Water Efficient Landscape
Ordinance
Hydrozone or Planting
Napa
855 Bordeaux
Irrigation
Irrigation
Total ETAF x Area
Landscape
DETENTION
BASIN PLANT PALETTE
Average ETAF
plant Factor (PF)
* PLANT MATERIALS PURSUANT TO THE
NCRWQCB
PLANT PALETTE.
26,093
ETAF x Area
BOTANICAL NAME
COMMON NAME
SPACING
CONTAINER SIZE
TREES
Area (sgft.)
0
HETEROMELES ARBUTIFOLIA
TOYON
15' O.C.
15 GAL
Use (gal./yr.)
SHRUBS & GROUNDCOVERS
ORHAMNUS
CALIFORNICA
COFFEEBERRY WILD
6' O.C.
ROSE POTS
Drip
OROSA
CALIFORNICA
ROSE
6' O.C.
ROSE POTS
A-2 - Tree
#
0.4 Mod./Ave.
DESCHAMPSIA CESPITOSA
HAIR GRASS PURPLE
3' O.C.
4" POT
418
10,892
NASSELLA PULCHRUM
NEEDLE GRASS
2' O.C.
4" POT
0.4
O
ESCHSCHOLZIA CALIFORNICA
CALIFORNIA POPPY
2' O.C.
4" POT
LEYMUS TRITICOIDES
WILDRYE
3'0.C.
4" POT
BROMUS CARINATUS
CALIFORNIA BROME
2' O.C.
4" POT
SISYRINCHIUM BELLUM
BLUE-EYED GRASS
1' O.C.
4" POT
T
HORDEUM BRACYANTHERUM
BARLEY
HYDROSEED
100%
SEED MIX OF:
HYDROSEED
BROMUS CARINATUS
CALIFORNIA BROME
30%
SISYRINCHIUM BELLUM
BUTTERCUP BLUE-EYED GRASS
30%
TRIFOLIUM WILDENOVII
TOMCAT CLOVER
30%
VULPIA MICROSTACHYS
THREE-WEEK FESCUE
10%
Water Efficient
Landscape Worksheet
Adapted from California Code
of Regulations Title 23,
Division 2, Chapter 2.7. Model
Water Efficient Landscape
Ordinance
Hydrozone or Planting
Napa
855 Bordeaux
Irrigation
Irrigation
Total ETAF x Area
Landscape
Total Area
*Estimated
Average ETAF
plant Factor (PF)
All Landscape Areas
Efficiency (IE)
ETAF (PF/IE)
26,093
ETAF x Area
Total Water
Description (a)
0.48
Method (b)
Area (sgft.)
(c)
Use (gal./yr.)
Regular Landscape Areas
A -1 -Shrub
0.4 Mod./Ave.
Drip
0.81
0.5
45,828
22,631
589,314
A-2 - Tree
#
0.4 Mod./Ave.
Bubbler
0.81
0.5
847
418
10,892
A-3 - Bio -Retention
0.3 Low
Drip
0.81
0.4
7,609
3,044
79.255
SUBTOTAL
Areas
1 10 0 0
2 1 0 0 0
3 1 0 0 0
SUBTOTAL 4 0 0 0
**Estimated Total Water Use (ETWU) 4 679,461
Maximum Allowed Water Allowance (MAWA) 4 1 777,455
(a) Hydrozone #/Planting Description (b) Irrigation Method
1.) Tree planting Bubbler
2.) Shrub planting Drip
**) MAWA (Annual Gallons Allowed)=
(Eto) x (0.62) x [ (ETAF x LA) + ((1-ETAF) x SLA)]
where 0.62 is a conversion factor that converts acre -inches
per acre per year to gallons per square foot per year, LA is
the total landscape area in square feet, and ETAF is 0.55
for residential areas and 0.45 for non-residential areas.
ETAF Calculations
Napa
855 Bordeaux
Regular Landscape Areas
West Sacramento
2101 Stone Blvd.
Total ETAF x Area
26,093
Total Area
54,284
Average ETAF
0.48
All Landscape Areas
W Sacramento,
CA 95691
Total ETAF x Area
26,093
Total Area
54,284
Sltewide ETAF
0.48
Detention Basin Landscape
(c) Irrigation Efficiency (*) ETWU (Annual Gallons Required)=
0.81 for bubbler Eto x 0.62 x ETAF x Area where
0.81 for drip 0.62 is a conversion factor that converts acre -
inches per acre per year to gallons per square
foot per year
erage ETAF (ET adjustment Factor) for Regular Landscape
=as must be 0.55 or below for residential areas, and 0.45
below for non-residential areas.
Bator developed to meet code effective Dec. 1, 2015
calculator is for estimating purposes only.
vandefToolen - Associates I www.vanderToolen.com
,
Napa
855 Bordeaux
Walnut Creek
700 Ygnacio Valley
West Sacramento
2101 Stone Blvd.
Way, Suite 240
Rd. Suite 100
Suite 115
-�
Napa, CA
94558
walnut Creek, CA
94596
W Sacramento,
CA 95691
tel 707.224.2299
tel: 925.274.1305
tel: 916.244.3000
LANDSCAPE ARCHITECTS
tax:707.224.6821
DESIGN CALLOUTS
O1 PRIVATE ENTRY CONCRETE WALK -SEE DETAIL A, SHEET L-1.6
O2 WOOD GOOD NEIGHBOR FENCE -SEE DETAIL B, SHEET L-1.6
O3 WOOD GOOD NEIGHBOR GATE -SEE DETAIL C, SHEET L-1.6
O4 ACOUSTIC GOOD NEIGHBOR FENCE -SEE DETAIL D, SHEET L-1.6
PRIVATE YARD LANDSCAPING PER HOMEOWNER
O6 FRONT &SIDE YARD PLANTING AREA
O7 PUBLIC SIDEWALK
O8 PRIVATE CONCRETE DRIVEWAY
O9 FRONT YARD ACCENT TREE
10 STREET TREE
11 PARKWAY PLANTING
12 PRECAST CONCRETE FENCE -SEE DETAIL E, SHEET L-1.6
13 GATE AT PRECAST CONCRETE FENCE -SEE DETAIL F, SHEET L-1.6
14 CONCRETE WALK -SEE DETAIL A, SHEET L-1.6.
0' 5' 10' 20' 40'[ 11 1 L�l 05
I I I
Scale: 1" = 10'-0"
APRIL 26, 2018 1 NORTH I Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
1
2
t1
vo J�
�/ 1 "l 1 0l
Al
O1 CONCRETE PAVING.
O2 REINFORCING PER SOIL'S REPORT
RECOMMENDATION.
O3 1/2" TOOLED RADIUS.
CLASS II AGGREGATE BASE,
COMPACTION, & THICKNESS PER SOIL'S
REPORT RECOMMENDATION.
O5 COMPACTED SUBGRADE OR
ENGINEERED FILL.
O6 1/4" WIDE X 3/4" DEEP TOOLED CONTROL
JOINT (SEE PLANS).
O7 3/8" WIDE FIBER FILLED EXPANSION
JOINT W/ POLYSULFIDE SEALANT.
SEALANT COLOR TO MATCH ADJACENT
PAVING. SEE PLAN FOR LOCATION.
O8 FINISH GRADE. 2" BELOW TOP OF
PAVING FOR PLANTING AREA.
99 THICKENED EDGE AT PLANTING AREA
WHERE REQUIRED OR UNDER
PEDESTALS.
CONCRETE PAVING
WWW.vanderTooIen.com
Napa
855 Bordeaux
Walnut Creek West Sacramento
700 Valley 2101 Sone Blvd.
�.
SCALE: 1-1/2" - 11-011
Way, Suite 240
Napa, CA
1 O1
2 X 4 TOP RAIL DADO (8' LENGTH)
94558
1A
3
707.224.2299
tel: 925.274.1305 tel: 916.244.3000
LANDSCAPE ARCHITECTS
ra, 707.224.6821
1A
1/2" EXTERIOR GRADE PLYWOOD INTO DADO @
TOP AND BOTTOM RAILS. CAULK INTO DADO
4
POSTS AND ALL JOINTS.
O2
TOP OF FOOTING AT TOP OF GRADE.
0
Vol)
4 X 4 PTDF POST @ 8' O.C.
5
O4
5/8 X 6 FENCE BOARDS - BUTT TIGHT
TOGETHER.
26
0
2 X 4 BOTTOM RAIL DADO WITH CLEAT TO
PLYWOOD
7
O6
2 X 8 KICKBOARD (PTDF) BACKFILL SOIL TO
=- —
--
SEAL. CAULK ALL JOINTS.
°
°° O7
FINISH GRADE, GRADE TO SLOPE AWAY FROM
�
° °
8 ELEVATION
° III
FENCE.
`y
'° 1
9 O8
CONCRETE FOOTING
°
O9
COMPACTED SUBGRADE OR ENGINEER FILL.
0 0 10 PLAN
10
6" AGG. DRAIN ROCK
FF
7FF1 1" = 1'-0"
NOTE:
1'-6" -ALL WOOD MEMBERS SHALL BE OF CONSTRUCTION GRADE REDWOOD OR CEDAR.
-ALL NAILS SHALL BE HOT DIPPED GALVANIZED.
SECTION -ALL CONNECTIONS W/ BUILDINGS, PILASTERS & POSTS MUST BE SEALED AIR TIGHT WITH FLEXIBLE
OUTDOOR CAULK.
ACOUSTIC GOOD NEIGHBOR FENCE
11
SCALE: 1/2" - V-0
1 TREE.
O4 TREE ROOTBALL SET ON
1 O2 2" DIAMETER LODGE POLE
LIGHTLY TAMPED SOIL. DO
PINE STAKE SET 30" INTO
NOT PENETRATE ROOTBALL
c, C GRADE OR UNDISTURBED
WITH STAKES.
2 SUBGRADE A MINIMUM OF 12" O5 3" DEEP WATERING BASIN.
3 BELOW BOTTOM OF
O FINISH GRADE.
ROOTBALL. PLACE STAKES
U
PARALLEL TO PREVAILING
O AMENDED BACKFILL.
N
WINDS.
® FERTILIZER TABLETS.
5
m
O RUBBER TWIST TIES - KNOT
o
U)
AND ATTACH TO STAKE W/
N
01-1
ROOFING TACK.
IxUoo�lx TWIST TIES
TWICE ROOTBALL WRAPPED IN A FIGURE
DIAMETER 1[811 AROUND TRUNK
1 TREE STAKING
G N.T.S.
IGNATUIW.
4670 Willow Rd Suite 200
Pleasanton, CA 94588
Phone (925) 463-1122
PLAN
Development Area Plan
NOTE:
-SCARIFY SIDES OF PLANTING PIT.
-FERLTILIZED TABS ARE NOT TO BE
USED WITH CALIFORNIA NATIVE PLANTS.
-DO NOT USE AMENDED SOIL FOR
CALIFORNIA NATIVE TREES.
-SET CROWN OF ROOTBALL 1" ABOVE
GRADE.
1'-6" -ALL IVAILJ bMALL bt MU I UWI tU
GALVANIZED.
SECTION
GOOD NEIGHBOR FENCE,
SCALE: 1/2" = 1'-0 "
8'-0" O.C.
1O 2 X 4 TOP RAIL DADO (16' LENGTH)
O2 TOP OF FOOTING AT TOP OF
GRADE.
O3 4 X 4 PTDF POST @ 8' O.C.
O4 5/8 X 6 FENCE BOARDS - BOARD
ONBOARD
O5 2 X 4 BOTTOM RAIL DADO
O6 2 X 8 KICKBOARD (PTDF)
O7 FINISH GRADE, GRADE TO SLOPE
AWAY FROM FENCE.
O8 CONCRETE FOOTING
O9 COMPACTED SUBGRADE OR
ENGINEER FILL.
10 6" AGG. DRAIN ROCK
N
5
4
WOOD GATE
SCALE: 1/2" = 1'-0 "
10'-0" CLR.
O1 2 x 6 PRECAST CONCRETE RAIL.
5 7 6 C
O2 5" SQ. PRECAST CONCRETE POST.
O3 CONCRETE FOOTING PER -------
MANUFACTURER
MANUFACTURER SPECIFICATIONS. 1" 2" CO
cY) O4 1 x 1 x 45° CHAMFER POST TOP.o.
M TYPICAL EACH POST.
NOTE: N
- ALL MEMBERS TO HAVE WOOD GRAIN
1PRECAST CONCRETE FENCE,
'--J SCALE: 1/211 = 1'-0 of
BRISTOL
TWICE ROOTBALL
DIAMETER
SHRUB
N.T.S.
Rohnert Park, California
O1 SHRUB - SET CROWN OF ROOTBALL
2" ABOVE FINISH GRADE.
O2 3" HIGH WATERING BASIN.
FINISH GRADE.
O AMENDED BACKFILL.
O5 SET ROOTBALL ON LIGHTLY
TAMPED SUPPORT.
FERTILIZER TABLETS - SEE
GENERAL PLANTING NOTES FOR
QUANTITY PER SHRUB SIZE.
O 3" DEPTH MULCH.
O8 COMPACTED SUBGRADE OR
ENGINEERED FILL.
NOTE:
1. FERTILIZER TABS ARE NOT TO BE
USED WITH CALIFORNIA NATIVE
SHRUBS.
2. DO NOT USE AMENDED SOIL
FOR CALIFORNIA NATIVE SHRUBS.
Landscape Details
NOTE: (.o
- CONTRACTOR SHALL SUBMIT SHOP N
DRAWINGS TO LANDSCAPE ARCHITECT FOR
APPROVAL PRIOR TO CONSTRUCTION.
- ALL WELDS SHALL BE GROUND SMOOTH.
- METAL SHALL BE POWDER COATED. COLOR
TO MATCH PRECAST SPLIT RAIL FENCE.
O1 GATE LATCH.
O (2) GATE HINGES.
O3 2 X 4 DIAGONAL BRACE.
O 2 X 4 HORIZONTAL BRACE.
O5 5/8 X 6 ALTERNATING BOARDS.
O6 FINISH GRADE.
O7 4 X 4 POST PTDF - SEE FENCE DETAIL,
DETAIL B, THIS SHEET, FOR FOOTING.
O8 ADJACENT FENCE. SEE
DETAIL B, THIS SHEET.
NOTE:
- ALL WOOD MEMBERS SHALL BE
CONSTRUCTION GRADE REDWOOD OR
CEDAR.
- ALL NAILS SHALL BE HOT DIPPED
GALVANIZED.
- GATES WIDER THAN 3'-0" REQUIRE 4" X
6" POST, HINGED SIDE ONLY.
E!
1
O1 2 x 6 PRECAST CONCRETE RAIL.
1
O2 5" SQ. PRECAST CONCRETE POST.
O3 CONCRETE FOOTING.
44 1 x 1 x 45° CHAMFER POST TOP.
TYPICAL EACH POST.
O5 5" SQUARE TUBESTEEL.
O6 (2) 5' WIDE TUBESTEEL GATE.
T, O7 LOCKING LATCH.
O8 HEAVY DUTY HINGES.
GATE6�� PRECAST CONCRETE FENCE,
SCALE: 1/2'1 = 1'-0 of
PLAN VIEW PUBLIC STREET
MAILBOX ENCLOSURE
SCALE: 1/4" = 1'-0"
vandefToolen • Associates
WWW.vanderTooIen.com
Napa
855 Bordeaux
Walnut Creek West Sacramento
700 Valley 2101 Sone Blvd.
�.
��
Way, Suite 240
Napa, CA
Rd Suite 100 Suite 115
Rd. Su
Walnut Creek, CA W_ Sacramento,
■������_ -�
94558
94596 CA 95691
707.224.2299
tel: 925.274.1305 tel: 916.244.3000
LANDSCAPE ARCHITECTS
ra, 707.224.6821
Scale: See Detail
`19:�11011
(3) 16 UNIT CBU MAILBOXES, FRONT LOADING.
REFER TO CALLOUT, SHEET L-1.1 FOR
SPECIFICATIONS.
O2 CONCRETE SIDEWALK PER CIVIL ENGINEER.
O3 PARKWAY. REFER TO CYPRESS PRODUCTION
PLANS PREPARED BY VTA FOR PLANTING.
® STREET.
CONCRETE PAVING. SEE DETAIL A, THIS SHEET
APRIL 26, 2018
L-1.61
Project No. 06117
Copyright 2018 vanderToolen Associates. The drawings or written materials contained herein constitute the original and unpublished work of the landscape architect. Reproduction, use or alteration in any form is strictly prohibited without the written consent of vanderToolen Associates.
08.22.17
C4
H O M E S
LINEN
EDRO M _
10'-10" x 1 '-6"
O
OPTIONAL BEDROOM 5
FIRST FLOOR
SECOND FLOOR
TOTAL LIVING
TARGET
LOT COVERAGE
MAX COVERAGE
1527 SQ. FT.
729 SQ. FT.
2256 SQ. FT.
2200 SQ. FT
2145 SQ. F12 -
2400
T2400 SQ. FT.
O
O
_I
CD
00
X
O
I
CD
O
O
0
CV
Lo
5-0"
PLAN ONE 2256 SQ., FT.
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
CD
O
O
51-011—
I
'-0"—
W
00
LJOO
woodley
architectural
group,Inc
colorado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
california // 2943 pullman St. suite A
Santa ana, ca 92705 / 949 553.8919
CRAFTSMAN
I Composition Roof
2. Stucco
3, Corbels at Gable -End
4. Foam Trim
5- Board & Batten Gable -Er
6. Horizontal Lap Siding
7. Cultured Stone Veneer
MODERN FARMHOUSE
1. Composition Roof
2. Stucco
3. Gable -End Kickers
4. Foam Trim
5. Board & Batten Sidinc
6, Metal Roof
7 Wooden Posts
-4
MODERN PRAIRIE
I. Composition Roof
2. Stucco
3. Foam Trim
4, Horizontal Lap Siding
5. Cultured Stone Veneer
elevationA - CRAFTSMAN :CALE:Li:.Ia
elevationB - MODERN FARMHOUSE '\ scJJA1.-10
elevationC - MODERN PRAIRIE SCALE 1/1 - I
08.22.17 PLAN ONE J FRONT ELEVATIONS
BRISTOL I SIGNATURE HOMES
:•! _ v.__ ..__I_.«.._ __.ROHNERT PARK, CALIFORNIA
reweonN r�IcwrcwlRv uoa�
IIllcion co 6�120/JO]dll l2Jl
cplNanb // ]1n3 p WTaii sL sic A
��inia orvA �a V: NS/9.955]B'nV
------ ------
I I
I
1 y I
1 Es1s I
-------------------
I I
I I
-4
I � r
1
ROOF PLAN
SCALE: I /8" = 1'-6'
REAR ELEVATION
w
RIGHT ELEVATION
SCALE: I /4" = 1'-0"
SCALE:y4"=l'I LEFT ELEVATION
08.22.17 PLAN ONE I ELEVATION 'A' CRAFTSMAN
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOI SQUARE FOOTAGE MAY VARY EASED ON CALCOLATON METHODS
SCALE: I /4" = I'-0'
woodley
architectural
group,inc
colorado // 731 southpark dr. suite B
Littleton, co 80120 / 303 683.7231
calXornia /12943 pullmon St. suite A
Santa ano, co 92705 / 949 553.8919
I r
I
I
I
I
I
I
3
r
�' I
I
j I
3.5:12 I
I
I
I
r--------------------i
1 _
I
4:12 I
ROOF PLAN SCALE: 1/8''=1'-0"
REAR ELEVATION
08.22.17
C4H O
SCALE: 1/4" = l'-0"
RIGHT ELEVATION
LINE OF FENCE
SCALE: 1/4'' = l'-0"
LEFT ELEVATION
PLAN ONE I ENHANCED ELEVATION 'A' CRAFTSMAN
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4'' = l'-0"
odley
hitectural
Iroup,inc
731 southpark dr. suite B
80120 / 303 683.7231
2943 pullman St. suite A
ca 92705 / 949 553.8919
ROOF PLAN
��
��
r�
u
r1
u
REAR ELEVATION
SCALE: I /8" = 1'-6'
w
RIGHT ELEVATION
SCALE: I /4•' = 1'-0"
scALE: t/4"=l-a' LEFT ELEVATION
08.22.17 PLAN ONE ELEVATION 'B' MODERN FARMHOUSE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOI SQUARE FOOTAGE MAY VARY EASED ON CALCULATION METHODS
r I CY JOAN NAC AR� ITE�Dl I$11.1 RON PRCWRAI NNARS ONLY ANNI AN TO IS JI "ANY OINA PURNI IRAN AT PRALPLOUINNY OR FINAL CORTART IN A NOR ARRI VAY NO 1� JODDR Ob AROEI CIA ARAC C C I WCOA �' ARC I JNAC AOA PAR,
SCALE: I /4" = I'-0'
woodley
architectural
group,inc
colorado // 731 southpark dr. suite B
Littleton, co 80120 / 303 683.7231
calXornia // 2943 pullmon St. suite A
Santa ano, co 92705 / 949 553.8919
I
I r
I vs
I
I
I
I
I
I
I
I
=� — a; —vi
I
� I
3.5:12
I
I
I
\ I
r---------------------
I
r--�
I 1
I 1
1 ,
15 712 1 5:12
1
1 I
PLAN SCALE: 1/8"
REAR ELEVATION
08.22.17
C4H O
T.0_FENCE
opo
rn
SCALE: 1/4" = l'-0"
RIGHT ELEVATION
SCALE: 1/4" = l'-0"
LEFT ELEVATION
PLAN ONE ENHANCED ELEVATION 'B' MODERN FARMHOUSE
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND OR ELIMINARY STU DIES 0NLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED 0R DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4'' = l'-0"
•
odley
:hitectural
jroup,inc
731 southpark dr. suite B
80120 / 303 683.7231
2943 pullman St. suite A
ca 92705 / 949 553.8919
I I
I I
I I
1
jz_ W 1
1 <Irz1
{r
I I
o
I
ROOF PLAN
REAR ELEVATION
FLU] IoEIoi
SCALE: 119':= 1'-0"
9
RIGHT ELEVATION
SCALE: 1 /4" = l' -O'
SCALE: u4"=r.a' LEFT ELEVATION
08.22.17 PLAN ONE I ELEVATION 'C' MODERN PRAIRIE
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
SOUARBASED
DME DRAW NV5 ue.mw®w W*N mao... NT AND MUMNMYn M UNLY nw AM NOT Tort um rn
NA ANY Mo MWNOTE: MM1104 EOoinGE W MMNY CWAM oNCU AKHMM N METHODS RON'IC TKW DIAW Gsm v rwrrt uw w DWLCArto v Wore wreas AWm PWwMD 01w MLF IPCHMK RN uwr. M,
SCALE: 1 /4" = l'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
e
2
T.O�IAB�
9
RIGHT ELEVATION
SCALE: 1 /4" = l' -O'
SCALE: u4"=r.a' LEFT ELEVATION
08.22.17 PLAN ONE I ELEVATION 'C' MODERN PRAIRIE
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
SOUARBASED
DME DRAW NV5 ue.mw®w W*N mao... NT AND MUMNMYn M UNLY nw AM NOT Tort um rn
NA ANY Mo MWNOTE: MM1104 EOoinGE W MMNY CWAM oNCU AKHMM N METHODS RON'IC TKW DIAW Gsm v rwrrt uw w DWLCArto v Wore wreas AWm PWwMD 01w MLF IPCHMK RN uwr. M,
SCALE: 1 /4" = l'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
N
m
3� �4
4:12
1.1111 1
3.5:12 N 1
I
M I
n
3.5:12'
1 4:12
4:12
N�v
-------- - - - - -
-
I
I
1 5:12
----------------
ROOF PLAN
SCALE: 1/8" = l'-0"
REAR ELEVATION
08.22.17
C4H O
.40
SCALE: 1/4"= 1'-0"
RIGHT ELEVATION
SCALE: 1/4"=1'-0"
LEFT ELEVATION
PLAN ONE I ENHANCED ELEVATION 'C' MODERN PRAIRIE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4'' = 1'-0"
•
odley
hitectural
jroup,inc
731 southpark dr. suite B
80120 / 303 683.7231
2943 pullman St. suite A
ca 92705 / 949 553.8919
CRAFTSMAN
I Composilion Roof
2. Stucco
3. Corbels at Gable -End
4 Foam Trim
5. Board & Batten Gable -Er
6. Horizontal Lap Siding
7. Cultured Stone Veneer
MODERN FARMHC
1. Composition Ro
2. Stucco
3. Gable -End KicU
4, Foam Trim
5. Board & Batten
6. Melal Roof
7. Wooden Posts
MODERN PRAIRIE _
I. Composition Roof
2. Stucco
3. Foam Trim
4, Horizontal Lap Siding
5. Cultured Slone Veneer
08.22.17
elevationA - CRAFTSMAN
elevationE - MODERN FARMHOUSE
elevationC - MODERN PRAIRIE \_ Z U rlr.l_
PLAN ONE I ENHANCED FRONT ELEVATIONS
BRISTOL I SIGNATURE HOMES
-^ M. ROHNERT PARK, CALIFORNIA^ ._.... .._._
woodley
prcghoup,iinG I
c oX•.e. // ra1 usnrrxata. su: X
�I k ro OQ[1Q�p@�Tn1
colNanb ]i4]on14sA
Y Y •^- jai lii un�, �� 927051905/949553518919
r- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
I I
I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I
I I I I
I I I I
08.22.17
O
O
CD
00
X
0
CD
FIRST FLOOR
1 173
SQ.
FT.
SECOND FLOOR
1316
SQ.
FT.
TOTAL LIVING
2489
SQ.
FT.
TARGET
2400
SQ.
FT
LOT COVERAGE
2077
SQ.
F12-
TMAX
MAXCOVERAGE
2400
SQ.
FT.
PLAN TWO 1 2489 SQ., FT.
IN
40'-0"
BRISTOL I SIGNATURE HOMES
U «e
H O M E S ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
5-0"
O
Lo
O
woodley
architectural
group,lnc
colorado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
california // 2943 pullman st. suite A
santa ana, ca 92705 / 949 553.8919
CRAFTSMAN
I. Composition Roof
2. Stucco
3. Corbek at Gable -End
4. Foam Trim
5. Board & Batten Gable -I
6. Horizontal Lap Siding
7. Cultured Slone Veneer
MODERN FARMHOUSE
I. Composition Roof
2. Stucco
3, Gable -End Kickers
4. Foam Trim
5. Board & Batten Siding
6. Metal Roof
7. Wooden Posts
& Decorative Shutters
MODERN PRAIRIE
I Composition Roof
2, Stucco
3. Foam Trim
4. Horizontal Lap Siding
5. Cultured Stone Venel
elevationA - CRAFTSMAN
elevationBl - MODERN FARMHOUSE - -
elevo#FonC - MODERN PRAIRIE °`
08.22.17 PLAN TWO I FRONT ELEVATIONS
�BRISTOL I SIGNATURE HOMES
_. _. ._ ._..._._ . _.._ ..... ROHNERT PARK, CALIFORNIA.." -- -
woodley
argraup,i c I
�awaen7/;ai wmw v ..+nl r
�gldl // W1391]a] M ]01
caMlaMa//]94] 705/nfl5WIOA
�anla em ca Vl]OS / 919 55]B919
---------------------------------,
I I
I ix I
I I
I I
I I
I �
410
I I 71
� I
ROOF PLAN SCALE.= RIGHT ELEVATION
T. .PL.
T. .WIN.
o w
e
N
T.O. SLAB
T. .WIN.
a
TO. SLAB
REAR ELEVATION SCALE:1/4"=1-0" LEFT ELEVATION
08.22.17 PLAN TWO I ELEVATION 'A' CRAFTSMAN
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE. SQUARE FOOTAGE MAY VARY EASED ON CALCULAPON METHODS
RNAR Qlklll�, I' I IT""' ',,I YI1.1 'III Q VI, ITT I PR;UWTTNkTT NIT ONLY ANLTAK IM TO RE USED "ANY OINEk PURPMR, SONAR AS PNALPLM� OR ANAL SNONAMkING COPYINTOPT I � N�5 QAAWAYT NAY AN Dg AMTR4 �NTNOFRNM� A�ORMP
SCALE: I /4" = 1'-0"
SCALE: I RIC = 1'-0"
a'
woodley
architectural
group,inc
colorado // 731 southpark dr. suite B
Littleton, co 80120 / 303 683.7231
callfornla // 2943 pullmon St. suite A
Santa ano, co 92705 / 949 553.8919
412
7 I I
I I
I I
I I
I I
I I
I I
I
1SoI
I
I I
I I
I I
r I
I
I I
_
_
I
I
I
I
I
I
I
ROOF PLAN SCALE.= RIGHT ELEVATION
T. .PL.
T. .WIN.
o w
e
N
T.O. SLAB
T. .WIN.
a
TO. SLAB
REAR ELEVATION SCALE:1/4"=1-0" LEFT ELEVATION
08.22.17 PLAN TWO I ELEVATION 'A' CRAFTSMAN
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE. SQUARE FOOTAGE MAY VARY EASED ON CALCULAPON METHODS
RNAR Qlklll�, I' I IT""' ',,I YI1.1 'III Q VI, ITT I PR;UWTTNkTT NIT ONLY ANLTAK IM TO RE USED "ANY OINEk PURPMR, SONAR AS PNALPLM� OR ANAL SNONAMkING COPYINTOPT I � N�5 QAAWAYT NAY AN Dg AMTR4 �NTNOFRNM� A�ORMP
SCALE: I /4" = 1'-0"
SCALE: I RIC = 1'-0"
a'
woodley
architectural
group,inc
colorado // 731 southpark dr. suite B
Littleton, co 80120 / 303 683.7231
callfornla // 2943 pullmon St. suite A
Santa ano, co 92705 / 949 553.8919
ROOF PLAN
SCALE: 1/8" = 1'-0"
REAR ELEVATION
08.22.17
C4H O
SCALE: 1/4'' = l'-0"
RIGHT ELEVATION
LEFT ELEVATION
T.Q. FENCE
PLAN TWO I ENHANCED ELEVATION 'A' CRAFTSMAN
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
I
I
I
I
I
III
SCALE: 1/4" = l'-0"
SCALE: 1/4'' = l'-0"
•
odley
:hitectural
jroup,inc
731 southpark dr. suite B
80120 / 303 683.7231
2943 pullman St. suite A
ca 92705 / 949 553.8919
ROOF PLAN
REAR ELEVATION
SCALE: 119':= 1'-0"
T.. PL.,
W
d 0I
i.
T.O.LA
RIGHT ELEVATION
SCALE: 1/4"=r.a' LEFT ELEVATION
08.22.17 PLAN TWO ELEVATION 'BI MODERN FARMHOUSE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
MME o55WixG5AANMa®RNFAFMN m w.wu
IONIMNn.NV n.. VIAM ONLY w. uu wx NOT TOY uIN ANY OMR
NOTECHM"REFOOinaE,nnv MMNOVARY CWFMBASED oNaNEYAKF ON METHODS�URAL GROF1 IC TKW MRAWNU5 my WffM AW OR DWLiC•VD wmNon THE EXAMS AAMN rawk.+ OFIOMLn ARCMMKVURPA MAN' M,
SCALE: 1 /4" = l'-0"
SCALE: 1 /4" = l'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
ROOF PLAN SCALE: 1/8"=1'-0"
REAR ELEVATION
08.22.17
c/ H o /u?e
SCALE: 1/4" = l'-0"
RIGHT ELEVATION
LEFT ELEVATION
PLAN TWO I ENHANCED ELEVATION 'B' MODERN FARMHOUSE
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4" = l'-0"
SCALE: 1/4'' = l'-0"
woodley
architectural
group,inc
colorado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
california // 2943 pullman St. suite A
Santa ana, ca 92705 / 949 553.8919
•
ROOF PLAN
UllMINK
Inalml
REAR ELEVATION
SCALE: 119':= 1'-0"
T.. PL.,
W
d OF
i.
T.O.LA
RIGHT ELEVATION
SCALE: 1/4"=l' -a' LEFT ELEVATION
08.22.17 PLAN TWO ELEVATION 'C' MODERN PRAIRIE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
DME DRAWINGS ANNMa® FOfW*N C RON TAND ..axw•e.s M na. uu we NOT 'ON um NA ANN CANE. w
NOTE: A5 MAL EOOinaE,nnv RINUVARY 9ASEnoAO nEYA Fn URMETHODSAL GRONP HC mW DRAWWS w.v WffN AED OR WPLi[•rto w Wore WDES . PWwMD OF MLF IPCHN&MFu uvu.. M,
SCALE: 1 /4" = l'-0"
SCALE: 1 /4" = l'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
ROOF PLAN
SCALE: 1/8"= l'-0"
REAR ELEVATION
08.22.17
C4H O
RIGHT ELEVATION
SCALE: 1/4"=1'-0'' LEFT ELEVATION
PLAN TWO I ENHANCED ELEVATION 'C' MODERN PRAIRIE
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4" = l'-0"
SCALE: 1/4'' = l'-0"
•
odley
hitectural
jroup,inc
731 southpark dr. suite B
80120 / 303 683.7231
2943 pullman St. suite A
ca 92705 / 949 553.8919
CRAFTSMAN
I- Composition Roof
2. Stucco
3. Corbels at Gable -End
4. Foam Trim
5. Board & Batten Gable-[
6. Horizontal Lap Siding
7. Cultured Stone Veneer
MODERN FARMHOUSE
I. Composition Roof
2. Stucco
3. Gable -End Kickers
4. Foam Trim
5. Board & Batten Siding
6. Metal Roof
7. Wooden Posts
8, Decorative Shulters
MODERN PRAIRIE
I. Composition Roof
2. Stucco
3- Foam Trim
4. Horizontal Lap Siding
5. Cultured Stone Vene
eievaiionA - CRAFTSMAN N_ AlE 111'• b'
elevationB - MODERN FARMHOUSE
elevationC - MODERN PRAIRIE
woodley
08.22.17 PLAN TWO I ENHANCED FRONT ELEVATIONS arc�hoeCtnral
BRISTQL I SIGNATURE HOMES37MI
�o aoim 1303 aas rni
_._ .......� ._....._...._ ROHNERT PARIL. CALIFORNIA�.�°w i°�
1°aw 9Z105 /9.v 55J.A
Supplemental Item
Agenda Item #10
City Council Meeting 8/14/2018
08.22.17
F-
0
O
I
O
00
X
O
I
O
L0
C
r\
5-0"
40'-0''
0
0
5-0"
FIRST FLOOR
1364
SQ.
FT.
o
SECOND FLOOR
1302
SQ.
FT.Q
`"
TOTAL LIVING
2666
SQ.
FT.
TARGET
2600
SQ.
FT
LOT COVERAGE 2110 SQ. FT:
MAX COVERAGE 2400 SQ. FT.
PLAN THREE 2666 SQ. FT.,
BRISTOL I SIGNATURE HOMES
U «e
H O M E S ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
wood ley
architectural
group,inc
colorado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
california // 2943 pullman St. suite A
Santa ana, ca 92705 / 949 553.8919
CRAFTSMAN
1, Composition Roof
2. Stucco
3. Corbels at Gable-
4. Foam Trim
5. Horizontal Lap Sidi
6- Cultured Slone Ve
MODERN FARMHOUSE
l,. Composition Roof
2. Stucco
3, Gable -End Kickers
4. Foam Trim
5. Board & Batten Sidinc
6- Metal Roof
7. Wooden Posts
8. Decorative Shutters
MODERN PRAIRIE
I. Composition Roof
2. Stucco
3. Foam Trim
4. Horizontal Lap Siding
5_ Cultured Stone Venel
6, Metal Posts
elevationB - MODERN FARMHOUSE
elevationC - MODERN PRAIRIE N- sc"`F I/' 1-0
08.22.17 PLAN THREE I FRONT ELEVATIONS
.. BRISTSIGNATURE HOMES ROHN
ROHNERT PARK, CALIFORNIA
woociley
orchlfectural
group,lnc
caomao // rn ,wlr Iwrc � :.,x�• a
Alllaon :u 601:4 / Rl] dd] ]4d1
caMaao // i9d] i:Jr'1�OI1 SI 5� I�• A
• :onto unu ca D:I05/9dv 55]0919
---------------
I_L _L ;
1
I I
1 1
I 1
I I
I I
12 1
l] 1
1
I I
1 I
1 1
1
1
I
I
I
1
1
I
I
I
I
I
4,12
I
I
1
---------------
I_L _L ;
1
I I
1 1
I 1
I I
I I
12 1
l] 1
1
I I
1 I
1 1
1
1
I
1
1
I
1
4,12
I
I
1
T
1
1
{+
ROOF PLAN
SCALE: 119':= 1'-0"
REAR ELEVATION
IN
RIGHT ELEVATION
1=1 all
MMMMMMMMMM
SCALE: 1/4"=r.a' LEFT ELEVATION
08.22.17 PLAN THREE ELEVATION 'A' CRAFTSMAN
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
Nue DRAWNc5.wwna®wW*N m.aaO..n•ND wprv.N•ar moss ONLY .w.x NOT TOYum wo
RA Ornw POE D:H0UnREM FMA QOGi E,nnv MMNUVARY 9ASEe ONCUCUI URMETHODSAL GRQNP HC TKW DRAWWS my MXM AED w DWLi[•rtow Wore MIRES AWNEN rawk.+ o.woomn AACNw�5u CNOUP Nc
SCALE: 1 /4" = l'-0"
SCALE: 1 /4" = 1'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
'=I
1=1 all
MMMMMMMMMM
SCALE: 1/4"=r.a' LEFT ELEVATION
08.22.17 PLAN THREE ELEVATION 'A' CRAFTSMAN
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
Nue DRAWNc5.wwna®wW*N m.aaO..n•ND wprv.N•ar moss ONLY .w.x NOT TOYum wo
RA Ornw POE D:H0UnREM FMA QOGi E,nnv MMNUVARY 9ASEe ONCUCUI URMETHODSAL GRQNP HC TKW DRAWWS my MXM AED w DWLi[•rtow Wore MIRES AWNEN rawk.+ o.woomn AACNw�5u CNOUP Nc
SCALE: 1 /4" = l'-0"
SCALE: 1 /4" = 1'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
I
I
I
I �a
I
I
4:14:12
4:12
ROOF PLAN
REAR ELEVATION
08.22.17
C4H O
SCALE: 1/8"= l'-0"
- - T.O. FENCE
SCALE: 1/4'' = l'-0"
E---------- ---------
I F1El
I
RIGHT ELEVATION
i
--------- T.0_FENCE
------------
LEFT ELEVATION
PLAN THREE I ENHANCED ELEVATION 'A' CRAFTSMAN
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENTAND PRELIMINARY STUDIES ONLYAND ARE NOTTO BE USED FOR ANYOTHER PURPQSE,SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC.THESE DRAWINGS MAY NOT BE USEDOR DUPLICATED WITHOUTTHE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4" = l'-0"
SCALE: 1/4'' = l'-0"
•
woodley
architectural
group,inc
ado // 731 southpark or. suite B
on, co 80120 / 303 683.7231
rnia // 2943 pullman St. suite A
a ana, ca 92705 / 949 553.8919
I
I
I
Q
,
I
I
I
I
SCALE: 1/8"= l'-0"
- - T.O. FENCE
SCALE: 1/4'' = l'-0"
E---------- ---------
I F1El
I
RIGHT ELEVATION
i
--------- T.0_FENCE
------------
LEFT ELEVATION
PLAN THREE I ENHANCED ELEVATION 'A' CRAFTSMAN
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENTAND PRELIMINARY STUDIES ONLYAND ARE NOTTO BE USED FOR ANYOTHER PURPQSE,SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC.THESE DRAWINGS MAY NOT BE USEDOR DUPLICATED WITHOUTTHE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4" = l'-0"
SCALE: 1/4'' = l'-0"
•
woodley
architectural
group,inc
ado // 731 southpark or. suite B
on, co 80120 / 303 683.7231
rnia // 2943 pullman St. suite A
a ana, ca 92705 / 949 553.8919
rr�
REAR ELEVATION
B
SCALE:/44"=I 01 LEFT ELEVATION
D
08.22.17 PLAN THREE ELEVATION 'B' MODERN FARMHOUSE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
Nne DRAWNc5.nMAD wWoN C ROAAMNTAND MRANNAar moss ONLY AND An NOT POMum gAL GRQNP HC
RA wPw POE D:H0UnREM FMA QOGi E,nnv MMNUVARY CWAniBASED ONCUCKI URMEIIIOOS
wnm DRAWWS my Nmn AUD w DWLi[.no w Wore MIRES AWNEN rawk.+ o.woomn AACNw�5u(ROIIP, we
■
SCALE: 1 /4" = l'-0"
SCALE: 1 /4" = l'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
I
I
�
I
I
,
,
I
I
I
I
�
�
�
-_�-
- .-......:
_ L
1
I 1
I
1
I
I
I
I
1
I
I I
I y I
I
I
EI
R
1 I
I 1
I
1 5'.Ix I
I T 1
I
I
I
I
I
I
Oj
I
SCALE: 1/B"=1'-9
RIGHT ELEVATION
ROOF PLAN
rr�
REAR ELEVATION
B
SCALE:/44"=I 01 LEFT ELEVATION
D
08.22.17 PLAN THREE ELEVATION 'B' MODERN FARMHOUSE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
Nne DRAWNc5.nMAD wWoN C ROAAMNTAND MRANNAar moss ONLY AND An NOT POMum gAL GRQNP HC
RA wPw POE D:H0UnREM FMA QOGi E,nnv MMNUVARY CWAniBASED ONCUCKI URMEIIIOOS
wnm DRAWWS my Nmn AUD w DWLi[.no w Wore MIRES AWNEN rawk.+ o.woomn AACNw�5u(ROIIP, we
■
SCALE: 1 /4" = l'-0"
SCALE: 1 /4" = l'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
ROOF PLAN
SCALE: 1/8"=1'-0"
REAR ELEVATION
08.22.17
C4H O
SCALE: 1/4" = l'-0"
I
-- - - ---- - - - - ---- - - - -- T.O.FENCE
I
RIGHT ELEVATION
LEFT ELEVATION
T.O. FENCE
PLAN THREE ENHANCED ELEVATION 'B' MODERN FARMHOUSE
i i
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4" = l'-0"
SCALE: 1/4'' = l'-0"
odley
.hitectural
jroup,inc
731 southpark dr. suite B
80120 / 303 683.7231
2943 pullman St. suite A
ca 92705 / 949 553.8919
I I
I e�rz I
I I
I I
I J I
I I,
_I_L _L -------•
L
412
I
44
I I T
ROOF PLAN
SCALE: 1/8 = I' -U'
REAR ELEVATION
IN
RIGHT ELEVATION
SCALE: 1/4"=r.a' LEFT ELEVATION
08.22.17 PLAN THREE ELEVATION 'C' MODERN PRAIRIE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
SOUARBASED
Nue DRAW NV5 ue.mw®w W*N mao... NT AND MUMNMYn M UNLY nw AM NOT Tort um rn
NA ANY Mo MWNOTE: HMMAL EOoinGE M MINUVARY CWAM ON CAUAKHMM N METHODS RQNPHC TKW DRAW Gsm v rwrrt uw w DWLCArto v Wore wreas AWNEN PWwMD o.woomn AACNNK Rk uwr. M,
SCALE: 1 /4" = 1'-0"
SCALE: 1 /4" = l'-0'
arcnnecxurai
group,inc
colarado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
calMornla // 2943 pullman st. suite A
Santa ana, ca 92705 / 949 553.8919
ROOF PLAN
REAR ELEVATION
08.22.17
C4H O
SCALE: 1/8" = 1'-0"
----1 1111------E----- ILl T.O. FENCE---------I----
SCALE: 1/4'' = l'-0"
RIGHT ELEVATION
LEFT ELEVATION
PLAN THREE I ENHANCED ELEVATION 'C' MODERN PRAIRIE
BRISTOL SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
NOTE: SQUARE FOOTAGE MAY VARY BASED ON CALCULATION METHODS
THESE DRAWINGS ARE INTENDED FOR DESIGN DEVELOPMENT AND PRELIMINARY STUDIES ONLY AND ARE NOT TO BE USED FOR ANY OTHER PURPOSE, SUCH AS FINAL PLOTTING OR FINAL ENGINEERING. COPYRIGHT WOODLEY ARCHITECTURAL GROUP, INC. THESE DRAWINGS MAY NOT BE USED OR DUPLICATED WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODLEY ARCHITECTURAL GROUP, INC.
SCALE: 1/4"= l'-0"
SCALE: 1/4'' = l'-0"
woodley
architectural
group,inc
colorado // 731 southpark dr. suite B
littleton, co 80120 / 303 683.7231
california // 2943 pullman St. suite A
Santa ana, ca 92705 / 949 553.8919
•
CRAFTSMAN
I. Composition Roof
2. Stucco
3, Corbels at Gable-
4. Foam Trim
5. Horizontal Lop Sidi
6. Cultured Stone Ve
MODERN FARMHOUSE
I. Composition Roof
I Stucco
3. Gable -End Kickers
4. Foam Trim
5. Board & Batten Siding
6. Metal Roof
7, Wooden Posts
B. Decorative Shutters
MODERN PRAIRIE
I. Composition Roof
2, Stucco
3. Foam Trim
4. Horizontal Lop Siding
5, Cultured Stone Venee
6. Metal Posts
clevationg - MODERN FARMHOUSE
A
elevationC - MODERN PRAIRIE \ i J ".. %I
N
08.22.17 PLAN THREE I ENHANCED FRONT ELEVATIONS
BRISTOL I SIGNATURE HOMES
ROHNERT PARK, CALIFORNIA
woodley
airchifectural
group.inc
w
=-
Q
00
r -_
CL
Z
o
Z
w
<
w
'
J
W
�I
5O
L
4�
U
L
U
W
N
O
2
V) LO
Z
< O
LL
LU
Z > n
LU LU y
0
0 LU
CC
L
M� LU
U
V)
i
I
c�
Z
L Z N _ L1
Lo 0
LL Q I
w rf
UJ
LU p
Q
LU
w
N
EXHIBIT B
CONDITIONS OF APPROVAL
TENTATIVE MAP AND DEVELOPMENT AREA PLAN
The conditions below shall apply to the Vesting Tentative Map (VTM) and Development Area
Plan (DAP) for the Bristol project within the University District Specific plan. The Bristol
project shall be developed in accordance with the General Plan (GP), University District Specific
Plan (UDSP), Final Development Plan, Mitigation Measures identified in the University District
Specific Plan Amended Final Environmental Impact Report (FEIR), and the Design and
Construction Standards.
The Conditions of Approval as stated herein are the obligation of the applicant/developer and
place no obligation either express or implied on the City. These Conditions of Approval run with
this Vesting Tentative Map and Development Area Plan as approved regardless of ownership at
time of recording.
General On -Going Conditions
1) The applicant shall comply with all documents approved by the City Council and adhere
to all exhibits presented by the applicant at the Planning Commission and\or City Council
meeting for approval of the University District Specific Plan- Gee Property Vesting
Tentative Map unless subsequently revised by the City.
2) The applicant shall comply with the UDSP FEIR. In addition, the applicant shall pay the
cost to monitor the MMs identified in the FEIR for the UDSP (SCH # 2003122014) as
they relate to the Gee property, kept on file in the Development Services Department.
The requirements contained in the Mitigation Monitoring Program (MMP) shall be
incorporated into these conditions and shall be constructed in accordance with the MMP.
3) The applicant agrees to indemnify, hold harmless and defend the City, its officers, agents,
elected and appointed officials, and employees, from any and all liability or claims that
may be brought against the City arising out of its approval of this Tentative Map and
Development Area Plan and associated entitlements pertaining to the University District
Plan save and except that caused by the City's active negligence or willful misconduct.
4) By accepting the benefits conferred under this approval, the applicant acknowledges all
the conditions imposed and accepts this approval subject to those conditions with full
awareness of the provisions of the Final Development Plan (FDP), as may be amended
from time to time, and the RPMC, as applicable.
5) The use of the property by the applicant/grantee for any activity authorized by this
approval shall constitute acceptance of all of the conditions and obligations imposed by
the City on this approval. The applicant/grantee by said acceptance waives any challenge
as to the validity of these conditions.
6) If the City is required to enforce any of the conditions of approval, the applicant shall pay
all City's costs. At the City's sole discretion, the City may require a cash deposit to cover
enforcement costs as a condition of the approval of any final map.
7) All improvements shall be in substantial conformance with the submitted Site Plan,
Exterior Elevations, and Landscape Plan, except as modified herein.
7
2018-112
8) The Maintenance Agreement and Maintenance Management Plan for the stormwater
water quality pond shall include a requirement that any vegetation in the pond be cut or
mowed each May and/or shall otherwise be maintained to eliminate a buildup of
vegetation. (Department of Public Safety -Fire)
9) The City shall have no obligation to maintain private alleys, or police the private
maintenance of the alleys. (Engineering Services)
Prior to the Approval of Improvement Plans/Issuance Grading Permit
10) The design of all entrances to the site shall be subject to Department of Public Safety
approval.
11) Final design and placement of walls and fences shall be in accordance with the standards
in the approved Development Area Plan and shall be approved by planning staff.
12) All trees within five feet of the public right-of-way shall have root barriers that are
approved by the Development Service Director.
13) A permanent automatic sprinkler shall be installed to maintain all landscape materials and
areas.
14) The applicant's engineer shall coordinate with the City Engineer to ensure that recycled
water is used for irrigation of the project's landscaping as feasible.
15) All exterior lighting shall be designed so as to prevent any spillover lighting onto
adjacent properties and rights-of-way. Lighting elements will be required to be recessed
within their fixtures to prevent glare. New lighting levels provided shall be compatible
with general illumination levels in existing areas to avoid a noticeable contrast in light
emissions, consistent with the need to provide for safety and security. Exterior project
lighting shall be reviewed and approved by Development Services Director.
16) The design of any entry monument signage shall be submitted to the Planning Division
for review and approval prior to installation.
17) All double-check valves provided for domestic water and fire sprinkler systems shall be
concealed from public view. Plans shall be submitted to the Development Services
Department and City Engineer for review and approval.
18) Building code provisions shall apply to the construction, alteration, moving, demolition,
repair, maintenance and use of any building or structure within the jurisdiction of the
City, except work located primarily in a public way, public utility towers and poles,
mechanical equipment not specifically regulated by building code provisions, and
hydraulic flood control structures. All projects shall comply with the most current code
recognized by the City at the time of their building permit application. All State and
local ordinances shall be applicable to current projects. (Building Services)
19) Geotechnical investigation reports shall be submitted for all building permit projects
unless waived by the Building Official. When required by the Building Official, the
potential for soil liquefaction and soil strength loss during earthquakes shall be evaluated
during geo-technical investigations. Compaction reports are required for each building
pad site and all compaction reports shall be submitted prior to a foundation inspection
8
2018-112
and in compliance with the soils and geo-technical recommendations. (Building
Services)
20) A completed and approved wet fire hydrants system, or other system approved by the
Building Official and Department of Public Safety (DPS), and all weather roads shall be
in place prior to any flammable or combustible material (such as wood) being brought
onto the site. The applicant may tie to the water system for fire flow only. Fire access
road shall meet the DPS Fire Access Road Standard. These fire access roads shall
continue to be accessible until acceptance of the public streets by the City. (Building
Services)
21) Pursuant to California State Assembly Bill 3158, the applicant shall pay the filing fee to
the Department of Fish and Game. The fee shall be submitted to the Planning Division
upon filing of any required Notice of Determination, along with any filing fee required by
the County Clerk/Recorder. The applicant should be aware that Section 21089(b) of the
Public Resources Code provides that any project approved under CEQA is not operative,
vested or final until the required fee is paid. Proof of fee payment may be required prior
to the issuance of building permits or filing of a final map. (Building Services)
22) All public utilities easements (PUE) and public access easements shall be open and
accessible at all times. (Building Services)
23) All septic tanks, leach fields and related items in the final map area shall be abandoned
and destroyed in a manner approved by the Department of Environmental Health
Services. All water wells shall be abandoned and destroyed in a manner approved by the
Department of Environmental Health Services. (Building Services)
24) The applicant shall submit plans and obtain separate building permits for retaining walls
over four (4) feet in height and for all other walls, fences and signs over six (6) feet in
height. (Building Services)
25) The applicant shall obtain a demolition permit for any structure to be demolished. All
underground structures shall be abated, back-filled, inspected and approved by Sonoma
County Environmental Health Services or the Building Official as applicable. (Building
Services)
26) For any project requiring an on-site inspector to monitor grading, construction and/or
development, the applicant shall deposit funds with the City to cover the full cost of an
inspector prior to any land disturbance. The City Engineer, as appropriate, shall approve
the amount and hire the inspector. (Engineering Services)
27) The developer shall implement a dust control program as part of the measures required by
the FEIR for air quality control and the requirements of PM 10 and the Best Available
Control Measures (BACM). The program shall ensure that, at the City Engineer's
discretion, a water vehicle for dust control operations is kept readily available at all times
during construction. The developer shall provide the City Engineer and Building Official
with the name and telephone number of the person directly responsible for dust control
and operation of the water vehicle. (Building Services)
28) A Tree Preservation and Removal Plan including a separate tree removal and sensitive
area plan shall be submitted to the Development Services Department for review and
approval in accordance with City ordinance. The plan shall show all sensitive areas and
2018-112
stands of trees that are to be protected during grading operations and include, in detail,
the method proposed to protect these areas. (Planning Services)
29) The applicant shall pay all application fees, plan check and inspection fees, recordation
fees, park in -lieu fees, encroachment permit fees, segregation of assessment fees and
other applicable miscellaneous fees in effect at the time the fee is paid as required in the
Fee Schedule or RPMC. The applicant shall receive credit against, or reimbursement of,
its park in -lieu fee for any dedication, or irrevocable offer of dedication, of park property.
(Planning Services)
30) All improvements shall comply with all applicable sections of the City of Rohnert Park
Municipal Code and any other applicable relevant plans of affected agencies, unless
superseded by the Specific Plan for this property. (Planning Services)
31) The improvement plans shall show water services to each building. All water meters shall
be within the public right-of-way unless the Public Works Director specifically approves
exceptions. The City shall not maintain water and sewer system lines beyond existing
main line stub outs or on private property, unless otherwise agreed to by the City. Access
easements shall be given to the City and recorded concurrently with the final map for any
exceptions approved by the City Engineer that require access to private property.
(Planning Services)
32) If applicable, easements of record not shown on the tentative map shall be relinquished or
relocated. Lots affected by proposed easements or easements of record, which cannot be
relinquished or relocated, shall be redesigned. All easements for off-site grading and
drainage shall be acquired prior to approval of construction on these properties.
(Planning Services)
33) The applicant shall provide cable or conduit for each residential lot for cable television
and Internet access. The applicant shall provide cable or conduit for fiber optics or other
smart technologies for each commercial lot for Internet access. The cable or conduit
shall be shown on the joint trench improvement plans and constructed before the final lift
of asphalt is placed on the adjacent street. (Planning Services)
34) Private streets or alleys shall be private facilities and shall have private street
maintenance, street sweeping and streetlights. Private streets shall have a visible
demarcation between the public and private areas and identified with signage that which
differentiates them from public streets. The City Engineer shall approve all signage for
private facilities with the approval of individual improvement plans for the project.
(Planning Services)
35) The declaration of covenants, conditions and restrictions (CC&R's) filed for each
development shall be prominently displayed in the project sales office at all times. The
CC&R's shall apply to both owners and renters. The CC&R's shall be written to require
renters to comply with the regulations of the CC&R's, and a copy of the CC&R's shall be
given to each renter. (Planning Services)
36) The applicant shall provide a master signage program and a "Master Model Home
Signage" program for all residential subdivisions in the Bristol community. The master
signage programs shall be reviewed and approved by the Planning Manager. (Planning
Services)
10
2018-112
37) Design and placement of walls and fences shall be in accordance with the standards in the
FDP and shall be approved by the Planning Manager. Walls and fences may be phased
for each development in the. (Planning Services)
38) All residential dwellings shall display illuminated street numbers in a prominent location
in such a position that the numbers are easily visible to approaching emergency vehicles
from both directions. The numbers shall be of a contrasting color to the background to
which they are attached and four (4) inches minimum in height. Flag lots will have their
address displayed in a prominent position at the driveway intersection with the street.
(Planning Services)
39) Prior to front yard landscaping installation by the applicant, plant species, location,
container size, quality and quantity of all landscaping plants and materials shall be
reviewed and approved by the Planning Manager for consistency with the approved
construction plans. All plant replacements shall be to an equal or better standard than
originally approved. (Planning Services)
40) Fire Hydrant spacing and placement should be consistent with the City of Rohnert Park
Standards, comply with Appendix C of the 2007 California Fire code, and the
amendments to table C 105.1 by RPDPS ordinance #793. Specific locations of Fire
hydrants shall be coordinated with the applicants Civil Engineer based on Fire Engine
response protocols. (Department of Public Safety -Fire)
41) All roadway, private lanes and drives shall comply with the City of Rohnert Park
Standards. Specifically reference Standard #202 "Alley, in regards to:
o Alley lighting shall meet the City's minor street requirements.
0 20 or more units will require a 24' alley width
o Alleys are to be use as secondary access only, with parking provided on primary
access roads. (Department of Public Safety -Fire)
42) Roadway widths should be consistent with the City of Rohnert Park Standards, or as
modified by approved tentative map, comply with Appendix D of the 2007 California
Fire code, and the amendments to RPDPS ordinance #793 Section 15.28.13103.2 —
15.28.13106.1. (Department of Public Safety -Fire)
43) Minimum interior and exterior turning radius for Fire Apparatus Access shall be all 20
feet and 40 feet. (Department of Public Safety -Fire)
44) Copies of the soils and geology reports and shall be reviewed and approved by the
developer's soils engineer and geologist prior to issuance of a grading permit. The
developer's soils engineer shall sign the plans stating that they conform to the soils report
recommendations. (Building Services)
45) All areas to be graded and left undeveloped shall have a revegetation plan as part of the
dust control program. The Development Services Director or his designee shall review
and approve the plan. The applicant shall guarantee the revegetation prior to issuance of
grading permits. (Planning Services)
46) The applicant shall provide adequate vehicle sight distance as specified by the State of
California, Department of Transportation's Highway Design Manual (latest edition) at all
11
2018-112
public and private street intersections. In addition, intersections and driveways shall
comply with City requirements for sight triangles. The design of the streets shall
incorporate public safety concerns, fire protection equipment movements, as well as the
location and pickup of solid waste. (Planning Services)
47) The applicant shall show the proposed structural sections for all private streets on the site
improvement plans and pay the City's plan check and inspection fee for the proposed
private improvements, including the water, recycled water, sewer and storm drainage
facilities in these areas, to assure that the improvements are designed and constructed to
City standards. (Planning Services)
48) Safety lighting at the end and at any curve in any private street, alley, lane or place shall
be provided for residential units that do not front on a public street. The lighting shall
include individual lights on each residential unit and\or streetlights on street light poles.
The City Engineer shall approve the lighting plans that include these facilities. (Planning
Services)
49) The applicant shall contact the solid waste franchised hauler and obtain their written
approval of the proposed solid waste pickup locations on private streets, alleys, lanes or
places. The pickup locations shall not be located in emergency vehicle access easements.
A copy of the written approval from the solid waste franchised hauler shall be submitted
with the street improvement plans for City review and approval. Provisions for paved
areas for trash receptacles on certain parcels shall be identified in the improvement plans
to service alley access residences; the trash receptacle cutouts shall be located on private
parcels fronting public streets and accommodate the receptacles for the respective lots.
(Planning Services)
50) Where required, the landscaping for the detention and/or retention basins shall be
reviewed and approved by the Planning Manager. (Planning Services)
51) The applicant will coordinate with the local bus system authority to facilitate local bus
service in the project and to determine bus stop locations and shelter improvements. The
bus shelter locations shall be shown on the improvement plans and reviewed and
approved by the City Engineer. A copy of the written correspondence with the local bus
system authority approving transit facilities shall be submitted with the first street
improvement plans for each map. (Planning Services)
52) Any above ground utility structures and appurtenances (e.g. cable TV boxes, phone splice
boxes) shall be limited to 36" in height, installed in a public utilities easement within the
applicant's property and within 10 feet behind street face of curbs. These locations shall
be screened with landscaping to the satisfaction of the Planning Manager. The landscape
screen shall not interfere with the utility companies' or DPS's access. (Planning
Services)
53) Electrical and water services shall be provided to all parks, landscape medians, and other
landscape areas in accordance with plans approved by the Public Works Director.
(Planning Services)
54) The improvement plans shall include placement of a fire hydrant at the north terminus of
each of the three motor courts. The hydrants shall be located in a public water line
easement and served by the water main in Keiser Avenue. Final placement of the
12
2018-112
hydrants shall be approved by the Department of Public Safety. The fire hydrants shown
on the Vesting Tentative Map may be adjusted as approved by the Department of Public
Safety. (Department of Public Safety -Fire)
55) As part of the improvement plan/ final map submittal package, an exhibit shall be
submitted delineating improvements to be maintained by the HOA, the CFD, and private
homeowner's. (Engineering Services)
56) Improvement Plans prepared by a Registered Civil Engineer shall be submitted for the
review and approval of the City Engineer showing grading, paving, utilities, drainage,
structures to be built, lighting and trash collection. The improvements plans shall include
parking lots, street and utility information including all concrete curb and gutter,
sidewalk, striping and signing, paving, water lines, storm drain lines and sewer lines as
necessary, erosion control and any necessary transitions. All improvements shall be in
accordance with the City of Rohnert Park Standard Improvement Details. Improvement
Plans shall include a Storm Water Pollution Prevention Plan including winterization and
erosion protection. (Engineering Services)
57) Storm drainage improvements shall be designed in accordance with the Sonoma County
Water Agency criteria. Hydrology calculations, pipe sizing and storm drain plans shall
be submitted for the review and approval of the City Engineer. (Engineering Services)
58) No lot- to- lot drainage is allowed except where easements for drainage are provided. No
drainage may discharge across sidewalks. (Engineering Services)
59) The applicant shall demonstrate for each building pad to the satisfaction of the City of
Rohnert Park as follows:
a) Adequate protection from 100 -year frequency storm; and
b) Feasible access during a 10 -year frequency storm. (Engineering Services)
60) Fire protection shall be in accord with the requirements of Rohnert Park Public Safety
Department. With the submittal of the improvement plans, calculations shall be provided
to the City and the Rohnert Park Public Safety Department to ensure that adequate water
pressures are available to supply hydrant flows and sprinkler flows. (Engineering
Services)
61) The improvement plans shall show a sewer lateral to each building in accord with City
Standards. (Engineering Services)
62) If private sewer lines are shared or if they cross property lines, a 10' private sewer
easement shall be shown in the Final Map / Parcel Map. The maintenance of any private
sewer line shall be included in the maintenance agreement for the overall site(s) which
have an interest in the particular sewer. (Engineering Services)
63) Right-of-way for Keiser Avenue shall be dedicated in fee to the City of Rohnert Park as
shown on the Vesting Tentative Map. Right dedication shall include the existing roadway
easement and an additional 16' of right-of-way to the south. (Engineering Services)
64) Offsite Improvements: Improvements in Keiser Avenue are generally non-existent,
including surface improvements (pavement, curb and gutter, sidewalk, streetlights, and
landscaping), wet utilities (potable water, sanitary sewer, recycled water, and storm
13
2018-112
drains), and dry utilities (electric, gas, phone, and cable). In addition, there is an existing
overhead pole line along the south side of the street that is in conflict with surface
improvements.
Prior to or concurrent with the in -tract improvement construction, the following offsite
improvements shall be completed:
• Extension of a 12" sanitary sewer from Hinebaugh Creek north on Snyder Lane to
Keiser Avenue, and extension of an 8" sanitary sewer from Snyder Lane east on
Keiser Avenue to the project entry street. The sewer improvements are not
currently subject to PFFP reimbursement. The City shall pursue addition of the
12" sewer to the PFFP program to provide for PFFP fee credits — in the event that
the City should not be successful in incorporating the sewer into the PFFP fee
credit program, then the 12" sewer in Snyder Lane shall be eligible for
reimbursement from future development based on the percentage of the number
of units to the total capacity of the sewer.
• Extension of a 10" water main from Snyder Lane east on Keiser Avenue to the
east edge of the property. PFFP fee credits shall be granted for the cost of
construction of the 10" water main. Calculations shall be provided to demonstrate
that fire flow and pressure will be available in the proposed Keiser Avenue water
main extension. Adequate fire flow and pressure may be dependent on connection
of the Keiser Avenue main to the Kerry Road water main extension from
Hinebaugh Creek to Keiser Avenue by Brookfield Homes. Should the
development proceed in advance of the Kerry Road improvements, the Developer
shall demonstrate that adequate fire flow and pressure is available to the
satisfaction of the Department of Public Safety through the dead-end Keiser
Avenue extension, OR the Developer shall complete the Kerry Road connection,
OR the Developer shall complete other improvements needed to provide adequate
fire flow and pressure.
• Extension of storm drain from Snyder Lane to the east boundary of the project.
PFFP fee credits shall be granted for the cost of construction of the storm drain.
• Extension of joint trench facilities from Snyder Lane to the east edge of the
project. Undergrounding of the existing pole line along the project frontage will
be accomplished with the installation of the joint trench facilities.
• Construction of Keiser Avenue surface improvements, including 34' wide
pavement section (face of curb to face of curb), and curb and gutter on the south
side of the street, from Snyder Lane to the east edge of the project. PFFP fee
credits shall be granted for the cost of the Keiser Road surface improvements.
(Engineering Services)
65) Full improvement of the Keiser Avenue project frontage will be required. Improvements
will include sidewalk, street lighting, street trees and landscaping, and any other items not
included in the City's CIP project. (Engineering Services)
66) Extension of a sanitary sewer to the site will be required. The sanitary sewer extension
will consist of two segments: (1) a 12" line in Snyder Lane from the existing College
Trunk Sewer near Hinebaugh Creek north to Keiser Avenue and (2) an 8" line in Keiser
14
2018-112
Avenue extending east from Snyder Lane to the project. The Developer is obligated to
complete both segments of the sewer prior to issuance of the first building permit for the
project and shall have the first right to construct either or both of the sewer segments.
The Developer shall fund the full cost of the sanitary sewer construction, and may enter
into a reimbursement agreement with the City for reimbursement from other properties
tying into the sewer main when those properties develop.
The Developer may request that the City construct the either or both segments of
the sewer line in conjunction with the City's Keiser Avenue/ Snyder Lane Capital
Improvement Project. The City has included the sanitary sewer line in the design
of its project, but has not funded the cost of constructing the sanitary sewer. Upon
written request by the Developer, the City will complete final design for the sewer
line and include the construction of either or both segments of the sewer line
within the City's project. The Developer's written request must be made no later
than 90 days before the City's scheduled date to advertise for bids.
Should the Developer request that either or both segments of the sewer line be
included in the City's project, the Developer shall pay all costs associated with the
design and construction of the sanitary sewer. If the Developer requests that City
construct either or both segments of the sewer, the City will, upon opening bids
for construction of each segment of the improvements, request funding from
Developer in the amount of 1)100% of the sewer costs for that respective
segment included in the lowest responsive bid 2) 10% of the sewer costs for
construction contingencies, 3) the pro -rata share of the City's inspection and
construction management costs associated with that respective segment of sewer
line, and 4) the pro -rate share of the City's design costs associated with the
respective segment of the sewer line (collectively referred to as the "Costs").
Within 10 days of the City's request for funding, the Developer will confirm its
intent to pay the Costs. Within 30 days of City's request for funding, the
Developer shall pay to City the full amount of the Costs. In the event that
Developer fails to pay the Costs or any portion thereof within 30 days, the City
will remove the sewer line from its project and Developer shall have the
obligation to design and construct the sewer line in accordance with all applicable
City standards and policies.
• In the event that the Developer requests and funds the City's construction of
either or both segments of the sewer, and the City's construction contract is
unreasonably delayed, and/or the City terminates its construction contract, the
Developer may pursue permitting, design, construction and installation of either
or both segments of the sanitary sewer, subject to City inspections and
acceptance. In this case and upon Developer's completion and City's acceptance
of improvements, Developer shall be entitled to reimbursement for its actual costs
from the funding previously provided to the City, provided that such
reimbursement will not exceed the amount of provided to but not utilized by the
City. (Engineering Services)
67) Calculations shall be provided to demonstrate that fire flow and pressure will be available
in the proposed Keiser Avenue water main extension, in advance of connection to the Kerry
15
2018-112
Road water main extension to Keiser Avenue, should the development proceed in advance
of the Kerry Road improvements. (Engineering Services)
68) Recycled water shall be utilized for irrigation. WELO calculations shall be provided with
the landscape plans. Irrigation design shall be in conformance with the City of Santa
Rosa Recycled Water User's Guide. (Engineering Services)
69) The City has included the extension of a recycled water main in Keiser Avenue from
Snyder Lane to Kerry Road in its' third phase of the Keiser Avenue CIP project. Prior to
the extension of the recycled water main, the developer shall temporarily use potable
water for irrigation. Developer shall pay the water consumption charges to City for
potable water actually used at the site for irrigation. (Engineering Services)
70) All existing overhead utilities within the subdivision and all proposed utilities shall be
placed underground. In addition, the existing overhead power line along the south side of
the Keiser Avenue frontage shall be placed underground. The City has included the
undergrounding of the Keiser Avenue line and construction of joint trench dry utilities
along Keiser Avenue in its' CIP project. The joint trench design will include utilities
needed to serve the development. In the event that the improvements are not completed
prior to approval of improvement plans, the applicant will be responsible for construction
of the joint trench improvements, from Snyder Lane to the easterly end of the
development. The applicant would be eligible for Public Facilities Fee Program (PFFP)
fee credits for any improvements included in the PFFP. (Engineering Services)
71) The development shall include the design and construction of utilities within existing or
proposed public right-of-way for electric, gas, telephone, communication and cable TV
shall be submitted to the City Engineer and Director of Development Services for review
and approval. Any above -ground utility boxes, cabinets or structures shall be specifically
approved by the City and screened from public view to the satisfaction of the Director of
Development Services and City Engineer. (Engineering Services)
72) A grading permit application shall accompany submittal of the each phase of Subdivision
Improvement Plans. Said application shall include the requirements listed in Sections
15.48 & 15.50 of the Municipal Code. The grading plans shall be in conformance with
the Bay Area Air Quality Management District guidelines for reducing construction
impacts and minimize dust emissions. (Engineering Services)
73) Each phase of development shall submit drainage plans subject to the review and
approval of the Sonoma County Water Agency ("SCWA"), the City of Rohnert Park and
these conditions of approval. Said plans shall meet or exceed SCWA standards and City
standards, whichever is more restrictive. All proposed building finished floor elevations,
including garages, shall be a minimum of 1 foot above the post construction 100 -year
water surface elevations. (Engineering Services)
74) The water quality/detention basin shall be designed to be in compliance with the current
Phase 1 Storm Water Permit issued by the North Coast Regional Water Quality Control
Board for Sonoma County. Improvements shall be in conformance with the City of Santa
Rosa Technical Guidance Manual. The pond shall provide 100% volume capture for the
1 -year, 24-hour storm. In addition, the project shall provide detention that limits runoff to
pre -construction levels for the 10 -year and 100 -year storm. The basin shall be provided
16
2018-112
with a 5 -mm. trash screen in accordance with current State stormwater requirements for
trash capture. The pond shall drain via gravity and no pumps will be allowed. The pond
shall be not be subject to groundwater intrusion. The pond shall be located in a parcel
dedicated to the City. The access gate to the basin shall be relocated from Keiser Avenue
to the internal street. (Engineering Services)
75) The development shall prepare improvement plans and calculations for the proposed
project, shall demonstrate no increase in the 100 -year water surface elevations of adjacent
properties and submit hydrology and hydraulic report(s) for the project demonstrating
that this requirement is met, subject to Sonoma County Water Agency and City of
Rohnert Park review and approval. (Engineering Services)
76) The development shall include the design by the project proponent for Erosion and
Sediment control plans prepared by a professional such as a Civil Engineer or certified
Erosion Control Specialist and shall meet the requirements listed in Section 15.52.030 of
the Municipal Code. The plans shall provide measures to avoid the introduction or
spread of noxious weeds into previously un -infested areas. These plans are subject to
review and approval by the City. Erosion and Sediment control plans shall be in
conformance with Chapter 15.52 of the Municipal Code except that the reference
document for design criteria shall be the City of Santa Rosa Standard Urban Storm Water
Management Plan (SUSMP) or most current City adopted SUSMP. (Engineering
Services)
77) The development shall include design by the project proponent of Street lighting on
public streets as well as private streets/alleys. The design shall be in accordance with City
standards and PG&E requirements. In addition, lighting for private streets and alleys
shall be designed in accordance with the Zoning ordinance and to the Public Safety
Department's satisfaction. (Engineering Services)
78) Each phase of development shall include design by the project proponent for roadways.
The design shall include slurry sealing specifications, subject to review and approval by
the City. All streets shall be slurry sealed prior to issuance of the last certificate of
occupancy or prior to acceptance of the public improvements, whichever occurs first
within each phase of development. (Engineering Services)
79) Each phase of development shall include the design by the project proponent for
installation of moisture barriers at the edges of all pavement sections for purposes of
maintaining constant moisture content of pavement sections, subject to review and
approval by the City. The design shall include moisture protection extending to 6 inches
below the aggregate base layer. The moisture barrier shall be a minimum of 4 inches
wide and consist of Controlled Low Strength Material (CLSM) in a 10 mil visqueen lined
trench or approved alternative method. (Engineering Services)
80) Soils beneath all roadways including alleys shall be lime treated based on site specific
tests and as recommended by a geotechnical engineer. (Engineering Services)
81) Each phase of development shall include design by the project proponent and all public
improvements shall comply with the latest version of the Rohnert Park Manual of
Standards, Details and Specifications. Reference to particular standards shall be made on
the improvement plans. Standards details and specifications shall not physically be
17
2018-112
included on the plans but shall be referenced. (Engineering Services)
82) For each phase of development the project proponent shall design alleys, with utilities
and appurtenances. These shall be private. (Engineering Services)
83) No utilities (sewer, water or storm drains) shall flow from a private utility to a public
utility and back to a private utility. No utilities (sewer, water or storm drains) shall flow
from a public utility to a private utility and back to a public utility. (Engineering
Services)
84) All utilities shall be located within dedicated and accepted public street rights-of-way.
Any exception must receive prior approval from the City Engineer. (Engineering
Services)
85) For each phase of the development the project proponent shall design all utilities in
compliance with City Manual of Standards and the California Department of Public
Health Drinking Water Program including vertical and horizontal separation between
utilities, curbs, gutters and monuments. (Engineering Services)
86) The applicant shall submit a copy of the CCRs and/or maintenance declarations for
private improvements (such as for maintenance of alleys and private utilities) to the City
Engineer and City Attorney for review and approval. Maintenance declaration(s) shall be
submitted prior to recordation of Final Map. (Engineering Services)
87) The applicant shall submit to the City of Rohnert Park for review and approval, evidence
that the CC&R's will include provisions for maintenance of:
a) Private storm drain systems.
b) The private motor courts
c) Utilities within private easements, driveways or alleys, except where
located in a public easement
d) Private landscaping (including side or frontyard landscaping located
outside of home fences).
e) Sidewalks in private areas
f) Mailboxes and associated lighting and waste receptacles. (Engineering
Services)
88) The following Construction Mitigation Measures shall be noted on and/ or incorporated
into the grading and improvement plans:
a. For any project requiring (as part of MMP) an on-site inspector to monitor
grading, housing construction and/or development, the applicant shall deposit
funds with the City to cover the full cost of an inspector prior to any land
disturbance. The City Engineer, as appropriate, shall approve the amount and hire
the inspector.
b. The developer shall comply with construction hours pursuant to Rohnert Park
Municipal Code Section 9.44.120.
c. All construction material waste and other debris shall be recycled to the extent
feasible. The applicant shall present a "clean site everyday" program to City
18
2018-112
building staff for approval. The program shall include on-site signage in English
and Spanish to be posted at construction entrances.
d. No animals shall be brought on site by construction personnel during work hours.
e. All material storage areas shall be fenced with at least a 6 -foot high chain link
fence with at least two separate points of access with sufficient width for
emergency vehicles. The access points shall be shown on the construction fire and
security protection site plan.
L The project shall comply with Biological Assessment prepared by Johnson
Marigot Consulting LLC, dated August 2017. (Engineering Services)
Prior to Approval of Final Map
89) Unless otherwise specified in these conditions, all conditions shall apply prior to
recordation of each final map or large lot final map. A "final map" shall mean a map that
results in buildable parcels of an acre or less in area. A "large lot final map" shall mean a
map that results in parcels larger than one acre in area. (Planning Services)
90) The final map shall be prepared by a licensed surveyor or civil engineer, showing all
parcels, rights-of-way, and easement(s). (Engineering Services)
91) The final map shall be submitted with a completed Land Development Review Submittal
Sheet, Final Map Completeness Checklist and Final Map Submittal Checklist as available
on the City web -site and any and all applicable fees. (Engineering Services)
92) The final map submittal shall include a title report (within last 30 days), supporting
documents, and calculations for City Engineer review. All calculated points within the
map shall be based on one common set of coordinates. All information shown on the map
shall be directly verifiable by information shown on the closure calculation printout. The
point (s) of beginning shall be clearly defined. All lot acreages shall be shown on the map
and shall be verifiable from information shown on the closure calculation printout.
(Engineering Services)
93) The local agency sheet of the final map shall include the following note:
"Prior to the issuance of building permits, all applicable development impact fees
shall be paid to the satisfaction of the Building Official and in accordance with
City and local district ordinances."(Engineering Services)
94) The Owner's Statement and Acknowledgement shall include the following language:
"The undersigned further relinquishes to the City of Rohnert Park all interest in
sub -surface water rights below 300 feet that they may have". (Engineering
Services)
95) The final map shall satisfy Rohnert Park Municipal Code section 16.14.010 D. 2.
regarding dedication of rights-of-way and easements. The final map shall show
dedication of the necessary right-of-way in fee title, sidewalk easements, public utility
easements and other easements for public water, sewer, and storm drain, as shown on the
tentative map or as needed per the final improvement design. (Engineering Services)
19
2018-112
96) Prior to the approval of the final map, the applicant shall provide evidence that its
surveyor has been retained to set all monuments required by the map. (Engineering
Services)
97) The final map shall identify who is responsible to own and maintain all parcels to be
created with the map. (Planning Services)
98) A Community Facilities District or any other funding mechanism allowed by law shall be
formed by the project proponent encompassing the entire tentative map property for the
purposes of funding the long-term maintenance of the public facilities built with the
project. The City shall be named as a third -party beneficiary to the district/association. A
Covenant, Condition and Restriction shall be placed on the formation that requires; that if
the property owners of the district vote to dissolve the district, a homeowner's association
shall be formed for the purposes of maintaining the facilities previously maintained by
the district. The CFD shall be created and the assessments levied prior to filing the final
map. The CFD shall be responsible for providing funds to maintain the following
improvements or services:
a) Street surface improvements (pavement, curb and gutter, sidewalk, and
striping and markings
b) Storm drains located in the public right-of-way or public drainage easements.
c) Street lighting
d) Landscaping located in the public right-of-way or public landscape
maintenance easements.
e) The water quality pond and associated landscaping
f) The walkway connection to the middle school and any associated landscaping
or lighting
g) Police services
h) Fire and Emergency Medical services (Engineering Services)
99) Prior to the approval of any final map the applicant shall provide the Development
Services Director with a copy of the recorded covenants, conditions and restrictions
(CC&R's) on the deeds for all lots within the project site, which inform subsequent
property owners of the nature and extent of existing agricultural activities, operations,
and facilities in the vicinity of the project site. The deed restriction shall also provide
notice of the potential conflicts or effects of typical agricultural activities outside of
project including but not limited to noise, odors, dust, agricultural spraying, livestock and
burning etc.
a. Any covenants, conditions, and restrictions (CC&R's) applicable to the project
property shall be consistent with the terms of these conditions and the City Code. If
there is conflict between the CC&R's and the City Code or these conditions, the City
Code or these conditions shall prevail.
100) The homeowners' association shall be responsible for maintaining all common facilities
pertaining to the Home Owners Association, including but not limited to, the
association's property, common drive aisles, private lighting, private landscaping, and
20
2018-112
private utilities, any security patrol services, if provided, and any other functions of a
homeowners' association. The homeowners' association shall comply with all NPDES
permit Best Management Practices in effect at the time. (Planning Services)
101) The CC&R's shall prohibit the on-site parking of recreational vehicles, including boats.
Parking shall be prohibited along emergency vehicle access easements, private streets and
alleys. The No Parking signs shall be approved by the DPS. A separate signing and
striping plan shall be provided to address on-site stop signs and no parking areas prior to
approval of any final map. (Planning Services)
102) Prior to or concurrent with approval of the final map, the applicant shall enter into an
Public Improvement Agreement to assure construction and completion of the public
improvements shown on the map. Said agreement shall specify and be accompanied by
the financial assurances required to ensure completion of the public improvements.
(Engineering Services)
103) Prior to approval of the final map, the applicant shall identify a direct access point from
the project site to the neighboring school site (Lawrence Jones Middle School). This
access point shall be formalized through an agreement with the School District and
access walkways/gates shall be maintained in perpetuity. The access improvements shall
include a pathway a minimum of 4' in width, contained within a minimum 8'wide public
access easement or separate parcel. The pathway shall extend from the internal public
street to the School District property. Pathway improvements shall continue onto the
School District property as needed to connect to the school walkway system. The
pathway shall be ADA compliant, with landscaping and safety lighting. Graffiti -resistant
screening/ fencing shall be provided along with side of the easement to screen adjoining
residences.
In the event that despite good faith efforts to provide the access to the neighboring school
site the applicant is unsuccessful in obtaining School District approval for the pathway
connection, then the applicant shall provide evidence of action by the school district to
prevent such access. (Planning Services)
104) Prior to the approval of the final map, the applicant shall secure all necessary rights-of-
way and easements for both onsite and offsite road, utility, and drainage facilities. Rights-
of- way and easements shall be dedicated on the map or provided by grant deed. The
developer shall prepare all necessary legal descriptions and deeds. (Engineering
Services)
105) Prior to City Council approval of the final map; the developer shall satisfy Rohnert Park
Municipal Code section 16.14.0 10 D. 2. regarding off-site dedication of rights-of-way
and easements. (Engineering Services)
106) Prior to City Council approval of the final map, the proposed sidewalk and landscaping
along the entire project frontage of Keiser Avenue, as well as the water quality pond
landscaping and the middle school path connection shall be designed by the project
proponent, shown on improvement plans and reviewed and approved by the City
Engineer and included in Subdivision Agreement to be constructed with the first phase of
construction. (Engineering Services)
107) The final map shall have a note on the local agency page stating "All fences, sound walls
21
2018-112
and retaining walls shall be constructed on private property and maintained by the private
property owner, unless specifically dedicated to and accepted by the City". (Engineering
Services)
108) Monumentation shall be provided to allow the re-establishment of all property corners of
lots within the subdivision, to the satisfaction of the City Engineer. (Engineering
Services)
109) Prior to the approval of the first final map including a large lot final map, the applicant
shall be responsible for costs of implementation of ensuring compliance with Mitigation
Measures contained in Mitigation Monitoring Plan (MMP) for the FEIR. The applicant
shall provide funding, in an amount determined by the Planning Manager to hire
consultants or staff to implement compliance monitoring. (Planning Services)
110) Prior to approval of the first final map, the street name and a theme for all street name
signage, including traffic signal signage, street corner signage, directional signs, and
other permanent fixtures depicting street names shall be submitted to the Planning
Manager for review and approval. (Planning Services)
111) Prior to the recordation of the Final Map, the applicant shall pay a park -in -lieu fee in the
amount of $248,816.00. (Planning Services)
112) The applicant shall submit a mailbox plan (locations and sizes) for all lots prior to
approval of any final map. The plan shall be approved by the Rohnert Park Post Office
and included with the first submittal of the improvement plans. The applicant shall
submit to the City a written confirmation from the Rohnert Park Post Office that the
mailbox locations are approved. The City will review and approve the location plan to
ensure adequate site distance and traffic safety measures are incorporated. (Building
Services)
Prior to Construction
113) Applicant must file a Notice of Intent to Comply with the Terms of General Permit to
Discharge Storm Water Associated with Construction Activity (NOI) with the State of
California Water Resources Control Board, and obtain a permit, prior to commencement
of any construction activity. (Engineering Services)
114) No construction shall be initiated for each phase until the Improvement Plans have been
approved by the City, all applicable fees have been paid, an encroachment permit and/or
grading permit has been issued and a project schedule has been submitted to the City
Engineer and a pre -construction conference has been held with the City Engineer or his
designee. (Engineering Services)
115) Developer shall secure an encroachment permit from the City prior to performing any
work within the City right of way, a State Highway or constructing within a City
easement. (Engineering Services)
Prior to the Issuance of Building Permits
116) Unless otherwise specified in these conditions, the conditions of approval shall apply to
each building permit. (Planning Services)
22
2018-112
117) Prior to issuance of a building permit, the applicant shall submit a designed weather
protection cover for the mailboxes for review by the Planning Manager.
118) Prior to issuance of a building permits for any single family residential unit, individual
plot plans shall be prepared by the project proponent, submitted and reviewed and
approved by the City. (Engineering Services)
119) Prior to the issuance of any building permit, irrigation plans shall be submitted to and
approved by Planning Staff and the City Engineer. Such plans shall be in substantial
conformance with the plan submitted as a part of this application. Recycled water shall be
used for irrigation of the project landscaping as feasible (landscaping within individual
lots is excluded from this requirement).
120) Prior to the issuance of a building permit for each residential unit, the applicant shall pay
an Affordable Housing in -lieu fee in the amount established by the City Council at the
time of building permit issuance. This fee shall be based on the project's obligation of 6.3
affordable housing units (per UDSP, page 46). (Planning Services)
121) In each neighborhood, prior to the issuance of the first building permit for each tentative
map phase, the applicant shall install and maintain on-site display signs. The on-site
display signs shall indicate the location for future development of lighted and non -lighted
parks and commercial parcels, cul-de-sac openings, apartments, or higher density
residential areas. These signs shall be located in a manner to be clearly visible to all
potential homebuyers in the Bristol community. The signing plan shall be submitted to
the Planning Manager for review and approval prior to installation of the signs.
(Planning Services)
Prior to the Building Occupancy
122) Prior to the issuance of Certificate of Occupancy, the applicant shall provide a set of
certified escrow instructions reflecting City's demand for payment of the Regional
Transportation Fee for each lot affected by this fee per Mitigation Monitoring Program in
place for the University District.
123) Prior to issuance of the first Certificate of Occupancy, the Developer shall provide a
Phase Occupancy Plan, demonstrating the order in which homes will be occupied and
how access will be provided to occupied homes, and how residents will be separated
from ongoing construction of remaining homes. (Engineering Services)
124) Prior to issuance of the first Certificate of Occupancy, all street, drainage and utility
improvements shall be substantially complete and operational, and all streets, sidewalks,
and other areas open to the public shall be free of construction material or activities, and
shall be fenced from remaining construction. (Engineering Services)
125) The middle school connection shall be completed and opened for use prior to occupancy
of the 21St home, but no late than six months after the occupancy of the first home. This
condition will not apply if the pathway is eliminated per the terms of COA #104.
(Engineering Services)
126) All buildings shall be connected to public water and sewer systems prior to occupancy.
Water and sewer service accounts shall be set up with the City Finance Department for
each structure with a building permit. (Planning Services)
23
2018-112
127) The applicant shall obtain all necessary permits and clearances from the Rohnert Park
Building and Public Safety Departments prior to occupancy of the project. (Planning
Services)
24
2018-112