Loading...
2021/09/09 Planning Commission Resolution (2) PLANNING COMMISSION RESOLUTION NO. 2021-17 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK, CALIFORNIA, APPROVING SITE PLAN AND ARCHITECTURAL REVIEW FOR EXTERIOR REMODEL OF BURGER KING AT 5020 REDWOOD DRIVE (APN 045-081-013) WHEREAS, the applicant, Sunny Ghai, filed Planning Application No. PLSR21-0003 for Site Plan and Architectural Review for an exterior remodel of an existing Burger King commercial building, in accordance with the City of Rohnert Park Municipal Code; WHEREAS, Planning Applications No. PLSR21-0003 was processed in the time and manner prescribed by State and local law; WHEREAS, on September 9, 2021, the Planning Commission reviewed Planning Application No. PLSR21-0003 at which time interested persons had an opportunity to testify either in support of or opposition to the project; and WHEREAS, at the September 9, 2021, Planning Commission meeting, upon considering all testimony and arguments, if any, of all persons desiring to be heard, the Commission considered all the facts relating to Planning Application No. PLSR21-0003. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK DOES RESOLVE, DETERMINE AND ORDER AS FOLLOWS: Section 1. That the above recitations are true and correct. Section 2. Factors Considered. The Planning Commission, in approving Planning Application No. PLSR21-0003, makes the following factors, to wit: A. That the developments general appearance is compatible with existing development and enhances the surrounding neighborhood. Criteria Satisfied. The applicant has proposed architecture consistent with the City adopted Design Guidelines which identifies a modern architectural style as one that consists of a variety of materials and textures that would be used to achieve visual interest. Exterior wall cladding materials may include metal siding, fiber cement siding, stone or terra-cotta cladding, wood siding, stucco or concrete. The use of natural materials is also encouraged; materials should accentuate natural colors and textures. The proposed project architecture boasts two different façade treatments, new vintage wood panels on the storefront system and metal canopies at all window locations throughout. B. That the development incorporates a variation from adjacent on-site and off-site structures in height, bulk, and area; arrangement on the parcel; openings or breaks in the façade facing the street; and/or the line and pitch of the roof. Criteria Satisfied. The existing sign tower will be removed to accommodate the updated look and feel of the new modern façade and to achieve architectural detailing proportioned to the building. Façade articulation elements were selected according to the design theme associated with the architectural style of the building. Ground floor articulation includes entry doors and windows, accented with metal awnings and the spacing of elements such as windows, doors, awnings have a consistent rhythm throughout. C. That the development will be located and oriented in such a manner so as to provide pedestrian, bicycle and vehicular connections with adjacent properties, as appropriate, and avoids indiscriminate location and orientation' Criteria Satisfied. The project proposes to remodel the exterior faqade with new signage una fugua. urchitectural elements. The project involves exterior modifications to an existing building and therefore there are no changes to the building orientation, setbacks, landscape ur.ur, o, parking on the site. The exterior modifications to the existing commeicial building *o.rld not alter the pedestrian, bicycle and vehicular connections with adjacent properties. The site as currently designed is consistent with this criteria. Section 3. Environmental Clearance. The project has been analyzed for compliance with the requirements of tn" Califomia Environmental Quality Act (CEQA) and found to be categoiically exempt as a Class 1 Exemption under Section 15301: Existing Facility. No further action is required pertaining to environmental review. NOW THEREFORE BE IT RESOLVED, that the Planning Commission does hereby approve planning ApplicationNo. PLSR21-0003 subject to the Applicant Design Package attached as Exhibit A and Conditions of Approval attached as Exhibit B' BE IT FURTHER RESOLVED that said action shall not be deemed final until the appeal period has expired and that the appeal period shall be ten (10) working days from the date of said action. No building permits shall be issued until the appeal period has expired, providing there are no appeals. DULY AND REGULARLY ADOPTED on this 9th day of Septembet,2l2| by the City of Rohnert Park Planning Commission by the following vote: AYES: -{- NOES: 0 ABSENT: I ABSTATN: O AUSTTN-DILLON Fl( BLAN nlorn A1r- STR|PLEN 0\c Marc Chairperson,Planning Commission Attest: Jennifer Secretary Attachments: Exhi A - Applicant Design Package Exhibit B - Conditions of ApProval 2 Reso 2021-17 PLOT PLAN OWNER: QUIKSERVE 25 E. AIRWAY BLVD., LIVERMORE, CA OWNER'S PHONE: 714-856-1105 OWNER'S EMAIL: MJCDESIGN1@YAHOO.COM ZONING: C-2 PARCEL AREA: 20,068 SQ. FT. PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT NORTH ELEVATIONWEST ELEVATION (street side)LEGEND:EXISTING BUILDINGDEMO SOUTH ELEVATIONLEGEND:EXISTING BUILDINGDEMO NORTH ELEVATIONWEST ELEVATION (street side)S-1MC-3GEF-9G1'-0"SIGNAGE FOR REFERENCE ONLYUNDER SEPARATE PERMIT6"MP-3GMP-3GMP-3G2'-0"MP-3GS-3S-1MC-3GEF-9G1'-0"SIGNAGE FOR REFERENCE ONLYUNDER SEPARATE PERMITECT-1GMP-3GMP-3G3'-0" SOUTH ELEVATIONMP-3GEF-9GMC-3G1'-0"S-1MP-3GMP-3G2'-0"MP-3GS-3EB-1GEB-1GEB-1GEB-1GEF-1GEF-1GEF-1GEF-1GMC-2GLIGHT BANDMC-1GMC-2GLIGHT BANDMC-1G2'-0" KEYNOTES: REFER TO A-6 FOR FINISH SCHEDULES1 REFER TO A-4 FOR WALL FINISH AND CEILING PLAN2 REFER TO A-5 FOR FLOORING PLAN3 INSTALL NEW LOCKING LATCH ON DOOR4 REPLACE SEATING AND FINISHES WITH NEW IN DINING5 DEMO EXISTING DINING FINISHES AND SEATING; PATCH AND6 OCCUPANCY LOAD SIGN PER 2016 SFS, SECTION 1004.3. LOAD 687 ONE TOILET AND LAV FOR EACH GENDER NEUTRAL RESTROOM 8 OKAY BASED ON OCCUPANCY LOAD. PORTABLE FIRE EXTINGUISHER SHALL BE PROVIDED PERCODE9 NOT USED10 REPLACE OLD WALL FINISH IN KITCHEN, WITHIN VIEW OF REPLACE 2X4 CEILING TILES WITH NEW; REPLACE (E) 2X4 LIGHTS CUSTOMERS, WITH NEW FRP11 12 A PLACARD SHALL BE PLACED NEAR THIS EXTINGUISHER THAT 13 STATES THAT THE FIRE PRTECTION SYSTEM SHALL BE ACTIVATED PRIOR TO USING THE PORTABLE FIRE EXTINGUISHER ILLUMINATED EMERGENCY POWER IS PROVIDED; SEE ELECTRICAL14 ALL DOORS IN RESTAURANT SHALL BE EQUIPED WITH CITY 15 G.C. SHALL VERIFY ALL EXISTING CONDITIONS ON-SITE PRIOR TO BID SUBMISSION & THE START OF ANY WORK. G.C. SHALL NOTIFY ARCHITECT & OWNER'S PROJECT MANAGER IMMEDIATELY IF ANY CONFLICTS, INCONSISTENCIES IN SCOPE ON PLANS VS. EXISTING FIELD CONFLICTS, OR IF OTHER WORK BY OTHER VENDORS N.I.C. MAY CAUSE ALTERATIONS TO WORK OR SCOPE PRIOR TO BID SUBMISSION. G.C. TO VERIFY ALL DIMENSIONS PRIOR TO BEGINNING DEMOLITION/CONSTRUCTION. NOTE TO GENERAL CONTRACTOR: NEW WALL, CLG. AND FLOORING FINISH SEE A-4, A-5,16 REPLACE ONLY BROKEN OR MISSING TILES17 REPLACE (E) LIGHTING TO LED18 REPLACE OR RELAMINATE EXISTING DOORS19 TACTILE RESTROOM SIGNS PER 1/ AD-4 AND 10/AD-220 TACTILE EXIT SIGNS/EXIT ROUTE SIGN PER 6/AD-121 A-6 AND DECOR PLANS W/ LED PLANS APPROVED PANIC HARDWARE ILLUMINATED EMERGENCY POWER PER 2016 CFC, SECTION 1008.322 PROVIDED; SEE ELECTRICAL PLANS REPAIR FLOOR, CEILING, WALLS AS NEEDED LEGEND: NEW 2X STUD WALL EXISTING WALL KITCHEN DINING ROOM STANDING TOTAL 930 S.F./200 826*S.F./30 83 S.F./5 5 28 17 50 KITCHEN DINING ROOM STANDING TOTAL 930 S.F./200 83 S.F./5 5 17 75 FIXED SEATING LOOSE SEATING 40 184 SF/15 13 OCCUPANCY LOAD FOR PLUMBING FIXTURE COUNT: OCCUPANCY LOAD: 75 BLDG DEPT. NOTES: REQUIRED EGRESS DOORS - CHAPTER 10: (1) EXIT DOOR REQUIRED PER CODE BUT TWO EXIT DOORS PROVIDED ACCESSIBLE PATH OF TRAVEL ACCESSIBLE SEATING NOTES: -MINIMUM OF 5% OF THE TOTAL SEATING IN DINING AREA IS ACCESSIBLE REQUIED NUMBER OF ACCESSIBLE SEATS: 68 SEATS X .05 = 3.75 PROVIDED ACCESSIBLE SEATS: 4 REFER TO INTERIOR ELEVATIONS RESTROOM FIXTURE NOTES: MODIFY PLUMBING FIXTURES AS SHOWN CAP OLD UN-USED PLUMBING LINES. PATCH AND REPAIR WALLS AND FLOORS AS NEEDED.26"CABINET44"CABINETFREE.COKE231818 2 A-3 4 A-3 1 A-3 4 456 7 8 8 9 11 12 13 14 15 15 15 16 17 18 19 19 19 19 2021 22 PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT REMODEL OF EXISTING BURGER KING RESTAURANT *Only a depiction of color and material and may not be exact building layout CERAMIC TILE NACHIHA PANELS EXTERIOR WAINSCOT "TAUPE TONE"LIGHT BAND "RED NATURAL""VINTAGE WOOD" PAINT PGP "MONTEREY "EP-2G""RED" "ECT-1G""EF-9G" CLIFFS "EP-4G" 800-423-4283 Los Angeles • Knoxville www.SignResource.com BK # 7766 5020 REDWOOD DRIVE, ROHNERT PARK, CA 94928 BK ROHNERT PARK, CA_B082321_JD/BS PAGE 1 OF 11 SITE PLAN SITE PLAN PAGE 2 OF 11 SCOPE OF WORK DESCRIPTION PART #PAGE #QUANTITY BKBZW60X55S01 BKBLTR13FGS1954S01 SR SIGN SR SIGN SR SIGN SR SIGN SR SIGN SR SIGN BKBS98DTUNIV-KIT BKBSCB9FT-KIT SR SIGN SR SIGN 5’-0” X 4’-7” LED IL LOGO WALL SIGN 13” FGS1954 CHANNEL LETTERS FGS CLOSED CANOPY KIT (22’-4”) 7'-6"L x 4'D CLOSED IL CANOPY 10'-0"L x 4'D CLOSED IL CANOPY 4'-6"L x 2'D CLOSED IL CANOPY 9'-0"L x 2'D CLOSED IL CANOPY 10'-0"L x 2'D CLOSED IL CANOPY DRIVE THRU OCU UNIT DRIVE THRU CLEARANCE BAR MONUMENT REPLACEMENT FACE 4’-0” X 3’-8” LED IL LOGO WALL SIGN 3 1 1 1 1 1 4 1 1 1 2 1 B C D F H J K E G I A 5 6 7 7 7 7 7 7 8 9 10 11 CANOPY SIZES ARE ESTIMATED AND MUST BE VERIFIED PRIOR TO RELEASING ORDER G G G G H F E A A A L C I J K B D L ELEVATION PAGE 3 OF 11 22'-4" G G F 22.78 SQFT A B C 22.02 SQFT H G 38'-0" NORTH ELEVATION SCALE 1:96 86'-6" WEST ELEVATION SCALE 1:96 44.80 TOTAL SQ.FT. 22.78 TOTAL SQ.F T. 10'-1"9'-1" 9'-1"9'-1"4'-7" 22.78 SQFT A SCOPE OF WORK DESCRIPTION PART #PAGE #QUANTITY BKBZW60X55S01 BKBLTR13FGS1954S01 SR SIGN SR SIGN SR SIGN SR SIGN SR SIGN SR SIGN BKBS98DTUNIV-KIT BKBSCB9FT-KIT SR SIGN SR SIGN 5’-0” X 4’-7” LED IL LOGO WALL SIGN 13” FGS1954 CHANNEL LETTERS FGS CLOSED CANOPY KIT (22’-4”) 7'-6"L x 4'D CLOSED IL CANOPY 10'-0"L x 4'D CLOSED IL CANOPY 4'-6"L x 2'D CLOSED IL CANOPY 9'-0"L x 2'D CLOSED IL CANOPY 10'-0"L x 2'D CLOSED IL CANOPY DRIVE THRU OCU UNIT DRIVE THRU CLEARANCE BAR MONUMENT REPLACEMENT FACE 4’-0” X 3’-8” LED IL LOGO WALL SIGN 3 1 1 1 1 1 4 1 1 1 2 1 B C D F H J K E G I A 5 6 7 7 7 7 7 7 8 9 10 11 CANOPY SIZES ARE ESTIMATED AND MUST BE VERIFIED PRIOR TO RELEASING ORDER L ELEVATION PAGE 4 OF 11 22.78 SQFT A D E 86'-7" 7'-5" 9'-10"9'-1" G 14.58 SQFT L 41'-6" EAST ELEVATION SCALE 1:96 SOUTH ELEVATION SCALE 1:96 22.78 TOTAL SQ.F T. 22.78 TOTAL SQ.FT. SCOPE OF WORK DESCRIPTION PART #PAGE #QUANTITY BKBZW60X55S01 BKBLTR13FGS1954S01 SR SIGN SR SIGN SR SIGN SR SIGN SR SIGN SR SIGN BKBS98DTUNIV-KIT BKBSCB9FT-KIT SR SIGN SR SIGN 5’-0” X 4’-7” LED IL LOGO WALL SIGN 13” FGS1954 CHANNEL LETTERS FGS CLOSED CANOPY KIT (22’-4”) 7'-6"L x 4'D CLOSED IL CANOPY 10'-0"L x 4'D CLOSED IL CANOPY 4'-6"L x 2'D CLOSED IL CANOPY 9'-0"L x 2'D CLOSED IL CANOPY 10'-0"L x 2'D CLOSED IL CANOPY DRIVE THRU OCU UNIT DRIVE THRU CLEARANCE BAR MONUMENT REPLACEMENT FACE 4’-0” X 3’-8” LED IL LOGO WALL SIGN 3 1 1 1 1 1 4 1 1 1 2 1 B C D F H J K E G I A 5 6 7 7 7 7 7 7 8 9 10 11 CANOPY SIZES ARE ESTIMATED AND MUST BE VERIFIED PRIOR TO RELEASING ORDER L SHOP DRAWING PAGE 5 OF 11 BKBZW60X55S0122.78 SQ. FT. A ILLUMINATION VIEW FRONT VIEW SIDE VIEW 3 1/2" 54 11/16” CABINET 60” CABINET 58” V.O. 57” FORMING AREA 52 11/16” V.O. 51 5/8” FORMING AREA DISCONNECT SWITCH DETAIL A DETAIL A 7/8”1/2” 1” SHOP DRAWING BKBLTR13FGS1954S0122.02 SQ. F T. B PAGE 6 OF 11 FRONT VIEW NIGHT VIEW ILLUMINATION 13" 244" (20'-4") SIDE VIEW 3” SHOP DRAWING TBD TBD TBD 22’-4” LIGHT FIXTURE AND AMOUNTS VARY ARCON DEPTH VARIES TBD “FL AME GRILLING SINCE 1954” CANOPY “FGS1954” CANOPY LEFT CANOPY TBD TBD RIGHT CANOPY L D DIM TBD TBD 22’-4” LED LIGHT FIXTURE SRSIGN TOTAL L DIM LIGHTING PART # 2’D CLOSED CANOPIES (NO TIE RODS) LENGTH PART #LIGHTING BKCC0246 BKCC029 BKCC0210 4'-6" 9'-0" 10'-0" LED TUBE FIXTURE LED TUBE FIXTURE LED TUBE FIXTURE L 24” WINDOW/DOOR AND DRIVE THRU STANDARD CANOPY SIZES F G H C PAGE 7 OF 11 4’D CLOSED CANOPIES LENGTH PART #LIGHTING BKCC0476 BKCC0410 7'-6" 10'-0" LED TUBE FIXTURE LED TUBE FIXTURE L 48” WINDOW/DOOR AND DRIVE THRU STANDARD CANOPY SIZES D E SECTION VIEW AS SEEN WHEN INSTALLED SECTION VIEW AS SEEN WHEN INSTALLED 1’-8 3/8”BOLTS PROVIDED BY OTHERS BOLTS PROVIDED BY OTHERS 8" REFERENCE PART#BKSWP 9 1/8" BKSTR21 46” BOLTS PROVIDED BY OTHERS BOLTS PROVIDED BY OTHERS 8" REFERENCE PART#BKSWP 1 3/4” HOLLOW SPACE .125” WALL THICKNESS BKSTR56 9 1/8” COMPONENTS ITEM PART #DESCRIPTION QTY 1BKBS98DTUNIV-A 1BKBS98DTUNIV-B OCU LED IL CANOPY OCU TOWER 1 1 A A B B 1BKBS98DTUNIV-A 1BKBS98DTUNIV-B SHOP DRAWING BKBS98DTUNIV-KIT I A A B B PAGE 8 OF 11 SHOP DRAWING BKBSCB9F T-KIT J COMPONENTS ITEM PART #DESCRIPTION QTY 1BKBSCB9FT-A 1BKBSCB9FT-B CLEARANCE BAR COLUM CLEARANCE BAR ARM 1 1 A B 1BKBSCB9FT-B 1BKBSCB9FT-A A B A B PAGE 9 OF 11 SHOP DRAWING SR SIGN K PAGE 10 OF 11 NIGHT ILLUMINATION VIEW NOT TO SCALE FRONT VIEW SIDE VIEW TBD TBD 1” 3/4” 1 EXHIBIT B ADOPTED PER PLANNING COMMISSION RESOLUTION NO. 2021- CONDITIONS OF APPROVAL: 5020 REDWOOD DRIVE – BURGER KING SITE PLAN AND ARCHITECTURAL REVIEW The conditions below shall apply to the Burger King commercial building exterior alterations project located at 5020 Redwood Drive (PLSR21-0003). General Conditions 1. The Site Plan and Architectural Review approval shall expire one year from the Planning Commission approval date, unless prior to the expiration a building permit is issued and construction is commenced and diligently pursued toward completion and the use is initiated, or an extension is requested and approved. 2. The facility shall comply with any and all applicable provisions of the Rohnert Park Municipal Code (RPMC) and any state or federal agency. The violation of any condition listed herein shall constitute a nuisance and a violation of the Rohnert Park Municipal Code. In conformity with Chapter 1.16 of the RPMC, a violation of the RPMC may be an infraction or a misdemeanor and shall be punishable as provided by law. In addition to criminal penalties, the City may seek injunctive relief. The Applicant agrees to pay for all attorney’s fees and costs, including, but not limited to, staff time incurred by the City in obtaining injunctive relief against the Applicant as a result of a failure of the Applicant to fully perform and adhere to all of the Conditions of Approval. 3. The Applicant agrees to defend, indemnify, hold harmless and release the City of Rohnert Park, its agents, officers, attorneys and employees from any claim, action or proceedings brought against any of the above, the purpose of which is to attack, set aside, void, or annul the approval of this application or certification of the environmental document which accompanies it. This indemnification obligation shall include but not be limited to, damages, costs, expenses, attorneys’, or expert witness fees that may be asserted by any person or entity, including the Applicant, whether or not there is concurrent passive or active negligence on the part of the City, its agents, officers, attorneys or employees. Planning Division Conditions 4. The project shall replace the existing non-compliant landscaping in accordance with the State’s most current Model Water Efficient Landscaping Ordinance (MWELO), or in accordance with water conservation standards which meet or exceed the requirements of the MWELO.Prior to building permit issuance, the Applicant shall submit a landscaping and irrigation plan that identifies landscape material types and locations, irrigation, water usage calculations, and other information as required for review and approval by the Director of Development Services. Landscaping shall be constructed in accordance with the State’s most current Model Water Efficient Landscaping Ordinance (MWELO), or in accordance with water conservation standards which meet or exceed the requirements of the MWELO. All costs for review of the requirements of the MWELO shall be borne by the Applicant. All landscaping and irrigation subject to the MWELO shall be substantially complete prior to final inspection. Staff shall work with the applicant to 2 maintain as much of the existing landscaping as possible to the maximum extent of state law. 5. Bicycle parking stalls installed as part of the project shall be in compliance with the Rohnert Park Zoning Ordinance Section 17.16.140. The C-R: Regional Commercial zoning designation requires four (4) bicycle parking spaces to be installed for the project. Two city standard “inverted U” bicycle racks will statisfy this requirement. 6. Per Rohnert Park Zoning Ordinance Section 17.27.060, no flags are allowed attached to the building or on any part of the property unless the flags are considered exempt per Section 17.27.040. 7. A sign review permit will be required prior to the issuance of a building permit for the sign installation. Engineering Conditions 8. The trash enclosure shall include a floor drain which is to be plumbed to the sanitary sewer. 9. Full-trash capture screens shall be installed at each of the parking lot storm drain inlets. Screens shall match State requirements for trash capture (5mm, screen, sided to treat 1- year, 1-hour storm. 10. The existing driveways shall be upgraded to current City tandards to be ADA compliant. Public Safety Conditions 11. An automatic fire sprinkler system shall be provided per Ordinance 938. 903.2.22. 12. Address nubers shall not be less than 12 inches high with a minimum stroke of one inch, and shall be illuminated as well as visile from the street. 15. Any fire sprinkler, fire alarm, or hood and duct system modifications require separate Fire Department permits.