Loading...
2021/07/08 Planning Commission Agenda Packet City of Rohnert Park Planning Commission NOTICE IS HEREBY GIVEN THAT A MEETING will be held on Thursday July 8, 2021 6:00 P.M. * COVID-19 NOTICE * Consistent with Executive Orders No. Order No. N-08-21 from the Executive Department of the State of California, the Meeting will not be physically open to the public and Commissioners/Committee Members will be teleconferencing into the meeting via Zoom Video Communications software. How to observe the Meeting: To maximize public safety while still maintaining transparency and public access, members of the public can observe the meeting on Cable Channel 26 or by visiting meeting central on our website https://www.rpcity.org/city_hall/city_council/meeting_central How to submit Public Comment: Members of the public may provide public comment by sending comments to the Recording Secretary by email at planning@rpcity.org. Comments are requested by 3:00 p.m. on the day of the meeting, but can be emailed until the close of the Agenda Item for which the comment is submitted. Email comments must identify the Agenda Item Number in the subject line of the email and should be a maximum of 350 words, which corresponds to approximately 3 minutes of speaking time. The comments will be read for the record, with a maximum allowance of 30 minutes of total public comments, subject to the Chair’s discretion. If a comment is received after the agenda item is heard but before the close of the meeting, the comment will still be included as a part of the record of the meeting but will not be read for the record or considered in connection with the agenda item. 1. CALL TO ORDER 2. PLEDGE OF ALLEGIANCE 3. ROLL CALL (Austin-Dillon_____ Blanquie____ Lam____ Orloff____ Striplen____) 4. PUBLIC COMMENT – Persons who wish to speak to the Commission regarding an item that is not on the agenda may do so at this time. Please see above for details on how to submit public comments. 5. CONSENT CALENDAR - ADOPTION OF MINUTES 5.1 Approval of the Draft Minutes of the Planning Commission Meeting of May 27, 2021 Commissioner Motion/Roll Call Vote: (Austin-Dillon_____ Blanquie____ Striplen____ Lam_____Orloff_____) 6. AGENDA ITEMS 6.1 PUBLIC HEARING: Renewal of Site Plan and Architectural Review for the Adega II at Rohnert Park Apartment Homes CEQA: This project does not necessitate further environmental review of the Project under CEQA, per the provisions of CEQA 15162, Subsequent EIRs and Negative Declarations. Commissioner Motion/Roll Call Vote: (Austin-Dillon_____ Blanquie____ Striplen____ Lam_____Orloff_____) 6.2 PUBLIC HEARING: Renewal of Site Plan and Architectural Review for the Green Acre Nursery and Supply Addition and Remodel CEQA: This project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA), under the CEQA guidelines as both a Class 1, Section 15301 modification of an existing facility. Commissioner Motion/Roll Call Vote: (Austin-Dillon_____ Blanquie____ Striplen____ Lam_____Orloff_____) 6.3 Discussion: In-person Planning Commission Meetings 7. ITEMS FROM THE PLANNING COMMISSION 8. ITEMS FROM THE DEVELOPMENT SERVICES STAFF 9. ADJOURNMENT NOTE: If you challenge the nature of the proposed action in court, you may be limited to raising only those issues you or someone else raised at public hearing(s) described in this agenda, or in written correspondence delivered to the City of Rohnert Park at, or prior to the public hearing(s). AMERICAN DISABILITY ACT ACCOMMODATIONS: In compliance with the Americans with Disabilities Act, if you need special assistance to participate in this meeting please call (707) 588-2231. Notification 72 hours in advance of the meeting will enable the City to make reasonable arrangements to ensure accessibility to the meeting (28 CFR 35.102.35.104 AD Title III). Appeals of any decisions made tonight must be received by the Planning Division within 10 days and no later than 5:00 p.m. on July 19, 2021. CERTIFICATION OF POSTING OF AGENDA I, Jennifer Sedna, Community Development Technician, for the City of Rohnert Park, declare that the foregoing notice and agenda for the July 8 , 2021 Planning Commission Meeting of the City of Rohnert Park was posted and available for review on July 2, 2021 at Rohnert Park City Hall, 130 Avram Avenue, Rohnert Park, California 94928. The agenda is available on the City of Rohnert Park’s website at www.rpcity.org. Signed this 2nd day of July, 2021 at Rohnert Park, California. Jennifer Sedna Minutes of the Planning Commission Meeting of the City of Rohnert Park Thursday, May 27, 2021 6:00 P.M. 130 Avram Avenue, Rohnert Park 1. CALL TO ORDER Chairperson Orloff called the regular meeting to order at 6:00 p.m. 2. PLEDGE OF ALLEGIANCE Led by Chairperson Orloff. 3. ROLL CALL Present: Tramaine Austin-Dillon, Commissioner Daniel A. Blanquie, Commissioner Fanny Lam, Vice Chairperson Marc Orloff, Chairperson Charles Striplen, Commissioner Absent: None. Staff attending via Zoom Video Communications: Planning Manager, Jeff Beiswenger, Planning Consultant, Emmanuel Ursu, and Recording Secretary, Jennifer Sedna. Staff present: IS Analyst, Mike Son. 4. PUBLIC COMMENT None. 5. CONSENT CALENDAR - ADOPTION OF MINUTES 5.1 Approval of the Draft Minutes of the Planning Commission Meeting of April 22, 2021. ACTION: Moved/seconded (Striplen/ Austin-Dillon) to adopt Minutes of the Planning Commission Meeting of April 22, 2021. Motion carried by the following unanimous (5-0-0) roll call vote: AYES: Austin-Dillon, Blanquie, Striplen, Lam and Orloff; NOES: None; ABSTAIN: None; ABSENT: None. 6. AGENDA ITEMS 6.1 PUBLIC HEARING: DEVELOPMENT AREA PLAN – File No. PLDP20- 0004 – Richmond American Homes – Consideration of Resolution 2021-08 recommending City Council approval of development area plan (DAP II) for 52 single-family homes and landscaping on property located south of Keiser Ave, north of Hinebaugh Creek and east of Griffin’s Grove Park on Lot Nos. 27 through 86 of the Vast Oak North Phase 3A – Alder (Seasons) subdivision. Planning Manager, Jeff Beiswenger, and Consultant Emmanuel Ursu, introduced the item and answered questions from the Commission, including: inclusion of solar options; a five bedroom maximum that staff recommends; water-use efficiency elements of the project; supporting a native, drought adaptive plan palette; developments in the K-section that were approved with six bedrooms; and, the need for multi-generational homes. Public Comment opened. Applicants Alicia Hintzen and John Peterson from Richmond American Homes answered questions from the Commission, including: pricing of the homes; limiting the number of bedrooms in the plans; and concerns about conditions of the resolution as currently written. No public comments. Public Comment closed. 1. ACTION: Moved/seconded (Blanquie/Lam) to adopt Resolution 2021-08 recommending City Council approval of development area plan (DAP II) for 52 single-family homes and landscaping on property located south of Keiser Ave, north of Hinebaugh Creek and east of Griffin’s Grove Park on Lot Nos. 27 through 86 of the Vast Oak North Phase 3A – Alder (Seasons) subdivision. Motion carried by the following unanimous (5-0-0) roll call vote: AYES: Austin-Dillon, Blanquie, Striplen, Lam and Orloff; NOES: None; ABSTAIN: None; ABSENT: None. 7. ITEMS FROM THE PLANNING COMMISSION Commissioner Striplen continues to search for a presenter for the requested wetland study session. 9. ITEMS FROM THE DEVELOPMENT SERVICE STAFF Staffperson Beiswenger stated the there will likely be meetings for the upcoming scheduled meetings. 10. ADJOURNMENT Chairperson Orloff adjourned the regular meeting at 6:43 p.m. ____________________________________ ___________________________________ Marc Orloff, Chairperson Jennifer Sedna, Secretary Page 1 City of Rohnert Park Planning Commission Report MEETING DATE: July 8, 2021 ITEM NO: 6.1 PREPARED BY: Suzie Azevedo, Assistant Planner AGENDA TITLE: PLTX21-0001 – Renewal of Site Plan and Architectural Review for the Adega II at Rohnert Park Apartment Homes LOCATION: Northwest Corner of Dowdell Avenue and Martin Avenue (143-040-139) OWNER/ APPLICANT: Milo Terzich/USA Multifamily Development, Inc. RECOMMENDED ACTION: Staff recommends that the Planning Commission adopt a Resolution approving a one year extension of Site Plan and Architectural Review (SPAR) for the Adega II at Rohnert Park (known as Terracina) Apartment Homes known as Lot 4 of the Five Creek Subdivision at the northwest corner of Dowdell Avenue and Martin Avenue. (Figure 1) Figure 1 – Project Location Page 2 BACKGROUND: The subject property is a 3.3 acre parcel known as Lot 4 of the Five Creek Subdivision at the northwest corner of Dowdell and Martin Avenue Extension or the southeast corner of the Five Creek Project Area. On February 25, 2020, the Five Creek development received City Council approval for a General Plan Amendment and a Stadium Area Master Plan (SAMP) Amendment to allow development of the proposed high density residential (Phase II) project in lieu of the previously contemplated retail development. On June 25, 2020, the applicant, USA Properties Fund, Inc, received Planning Commission approval for Site Plan and Architectural Review for a 73 unit fully self contained affordable apartment community. The approval included six new apartment buildings measuring three stories in height, a tot-lot community area consisting of BBQ units, picnic tables and a tot-lot structure as well as a club room/community center offering an activity area, full kitchen, computer lab, community flex space, and restrooms. The SPAR approval expires one year from the Planning Commission approval date, unless prior to the expiration a building permit is issued and construction is commenced and diligently pursued toward completion OR an extension is requested and approved. The applicant applied for a one-year time extension of the Site Plan and Architectural Review on June 2, 2021. The application was received prior to the expiration date of June 25, 2021 and the matter is being brought before the Planning Commission for consideration. ANALYSIS: Pursuant to Zoning Ordinance Section 17.25.035, Lapse of Approval/Renewal for Site Plan and Architectural Review approvals, the following shall apply: A. A Site Plan and Architectural Review approval shall lapse one year after the date of final approval or at an alternative date specific at the time of approval, unless 1. A building permit has been issued and construction has diligently commenced; or 2. A Certificate of Occupancy has been issued; or 3. The use is established; or 4. The Site Plan and Architectural Review approval is renewed in accordance with subsection B below. B. A Site Plan and Architectural Review approval may be renewed for an additional period of one year provided that prior to the expiration date, an application for renewal is filed with the Planning Commission. The Commission shall not deny the renewal request without first holding a Public Hearing and making findings supporting the reason for denial. If the Planning Commission denies the renewal request, the applicant shall have ten calendar days to appeal the decision to the City Council as set forth in Chapter 17.25 Article XII. As previously noted, the applicant has filed the necessary application pursuant to this provision. USA Properties is requesting an extension to allow for the finalization of construction drawings for building permit submittal early October, 2021. In conjunction with the extension application, Page 3 an Administrative Use Permit application was also filed for minor modifications to the SPAR approval as follows: • Replacing the affordable leasing office with a 2-BR apartment and amending the project from a 73 unit fully self-contained affordable apartment community to a 74 unit phase II of the Adega at Rohnert Park apartment community with ten percent of the new 74 units deed restricted to incomes at or below 120% AMI. • Opening vehicular and pedestrian connections to the existing Adega so residents have direct access to the community facilities and amenities, as well as a more direct route to access the City Park. • Embellishing the outdoor amenity area to improve furnishings and add seating areas, another BBQ, and a fire pit. These modifications are minor in nature and are being reviewed at staff level under the Administrative Use Permit filed. The site plan, building configuration, elevations, colors, and exterior finishes are unchanged from the June 25, 2020 SPAR approval. The affordability component of the project is in line with the adopted Development Agreement (DA), amended in 2020 under Ordinance 946, that requires the applicant to include ten percent of the units as affordable housing, which would be seven affordable units within the Phase II project, and that are restricted to tenants at the moderate income level. The project will remain subject to all other conditions as outlined in Resolution 2020-18, attached. ENVIRONMENTAL DETERMINATION: An Environmental Impact Report (EIR) was prepared for the original Stadium Area Master Plan. Previous changes to the General Plan and SAMP in 2017 triggered additional environmental review consisting of a Mitigated Negative Declaration. There were new mitigation measures largely limited to air quality and greenhouse gas emissions. The Phase II proposed Five Creek project was analyzed under CEQA Section 15162 and it was determined that the conclusions of the previous MND will not change regarding traffic and the mitigation measures beyond what were already required as part of the approved MMRP. As per the provisions of CEQA Section 15162, no further environmental review is required for the Five Creek project Phase II development. PUBLIC NOTIFICATION: A public hearing notice denoting the time, date and location of the proposal’s hearing was published in the Community Voice. Property owners within 300 feet of the project site were mailed notices, and the notice was posted pursuant to State Planning Law. RESPONSE TO NOTIFICATION: No public comments have been received on this item. _____________________________________________________________________________ Planning Manager Approval Date: 6/30/21 Attachments (list in packet assembly order): A. Planning Commission Resolution 2021-09  Exhibit 1 – Resolution No. 2020-018, adopted June 25, 2020 PLANNING COMMISSION RESOLUTION NO. 2021-09 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK APPROVING A ONE-YEAR EXTENSION OF THE APPROVAL OF SITE PLAN AND ARCHITECTURAL REVIEW FOR THE ADEGA II (TERRACINA) AT ROHNERT PARK APARTMENT HOMES WITHIN THE STADIUM AREA MASTER PLAN APN 143-040-139 WHEREAS, the City processed an application for Site Plan and Architectural Review (Planning Application No. PLSR20-0004) for the Adega II at Rohnert Park (Terracina) Apartment Homes (Project) located within the Stadium Area Master Plan in the time and manner prescribed by State and local law; and WHEREAS, on June 25, 2020, the Planning Commission of the City of Rohnert Park approved the Site Plan and Architectural Review of the Adega II at Rohnert Park (Terracina) Apartment Homes Project within the Stadium Area Master Plan; and WHEREAS, the applicant, Milo Terzich, USA Multifamily Devlopment, Inc. has submitted an application for a one-year time extension of the approval for Site Plan and Architectural Review pursuant to Section 17.25.035B. Lapse of Approval/Renewal, of the Rohnert Park Municipal Code; and WHEREAS, public hearing notices were mailed to all property owners within a 300 foot radius of the subject property and to all agencies and interested parties as required by California State Planning Law, and a public hearing was published for a minimum of 10 days prior to the public hearing in the Community Voice; WHEREAS, on July 8, 2021, the Planning Commission held a public meeting at which time interested persons had an opportunity to testify either in support or opposition to the proposed time extension for the Site Plan and Architectural Review; and WHEREAS, the Planning Commission, using their independent judgment, reviewed the time extension request and all evidence in the record related to the proposed project including the staff report, public testimony, and all evidence presented both orally and in writing. NOW, THEREFORE, BE IT RESOLVED that the Planning Commission of the City of Rohnert Park, California, hereby makes the following findings: A. The Planning Commission, at a public hearing on July 8, 2021 reviewed the applicant’s request for a one-year extension of the approval of Site Plan and Architectural Review for the Project, and all evidence in the record related to the Project including the staff report, public testimony, and all evidence presented both orally and in writing. B. The Planning Commission finds that a one-year extension of the approval of the Site Plan and Architectural Review for the Project is consistent with the approved plans and with the Rohnert Park Municipal Code Section 17.25.035.B. 2 Reso 2021-09 C. The Planning Commission finds that a one-year extension of the approval of the Site Plan and Architectural Review does not necessitate further environmental review of the Project under CEQA, per the provisions of CEQA 15162, Subsequent EIRs and Negative Declarations. NOW THEREFORE BE IT FURTHER RESOLVED, that the Planning Commission does hereby approve the applicant’s request for a one-year extension of the approval of Site Plan and Architectural Review for the Adega II at Rohnert Park (Terracina) Apartment Homes within the Stadium Area Master Plan subject to the following conditions: 1. The applicant shall comply with all applicable sections of the City of Rohnert Park Municipal Code. 2. The Project remains subject to the conditions as outlined in Resolution 2020-018, adopted by the Planning Commission on June 25, 2020 and attached hereto as Exhibit 1. 3. The applicant shall secure all necessary permits and clearances from the Rohnert Park Building and Engineering Departments prior to commencement of construction. DULY AND REGULARLY ADOPTED on this 8th day of July, 2021 by the City of Rohnert Park Planning Commission by the following vote: AYES: _____ NOES:_____ ABSENT:_____ ABSTAIN:_____ AUSTIN-DILLON_____ BLANQUIE____ LAM____ ORLOFF____ STRIPLEN____ Mark Orloff, Chairperson, City of Rohnert Park Planning Commission Attest: ________________________________ Jennifer Sedna , Recording Secretary Exhibit 1: Planning Commission Resolution 2020-018 PLANNING COMMISSION RESOLUTION NO. 2020-018 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK APPROVING SITE PLAN AND ARCHITECTURAL REVIEW FOR THE TERRACINA AT ROHNERT PARK APARTMENT HOMES, A 73 UNIT APARTMENT COMPLEX WITHIN THE STADIUM AREA MASTER PLAN (APN 143-040-139) WHEREAS, the applicant, Milo Terzich, USA Properties Fund, filed Planning Application No. PLSR20-0004 for Site Plan Architectural for a 73 unit apartment complex within the Stadium Area Master Plan in accordance with the City of Rohnert Park Municipal Code; and WHEREAS, Planning Applications No. PLSR20-0004 was processed in the time and manner prescribed by State and local law; and WHEREAS, the project is located within the Stadium Area Master Plan (SAMP), a Planned Development and so designated in the Rohnert Park Zoning Map; and WHEREAS, the project is consistent with the Final Development Plan for Residences at Five Creek approved by the City Council on February 25, 2020; and WHEREAS, the project is consistent with the Development Agreement for Residences at Five Creek that was approved by the City Council on February 25, 2020; and WHEREAS, a Conditional Use Permit is required for any phase of development in the Residences at Five Creek Planned Development district and a Conditional Use Permit was approved by the City Council on February 25, 2020, and a minor amendment to the CUP; and WHEREAS, on June 25, 2020, the Planning Commission reviewed Planning Application No. PLSR20-0004 for Site Plan and Architectural Review at which time interested persons had an opportunity to testify either in support of or opposition to the project; and WHEREAS, at the June 25, 2020, Planning Commission meeting, upon considering all testimony and arguments, if any, of all persons desiring to be heard, the Commission considered all the facts relating to Planning Application No. PLSR20-0004. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK DOES RESOLVE, DETERMINE AND ORDER AS FOLLOWS: Section 1. That the above recitations are true and correct. Section 2. Factors Considered. The Planning Commission, in approving Planning Application No. PLSR20-0004, makes the following factors, to wit: Exhibit 1 to Resolution 2 Reso 2020-018 A.That the developments general appearance is compatible with existing development and enhances the surrounding neighborhood. Criteria Satisfied The proposed apartment complex will fulfill Phase II of the apartment portion of the Final Development Plan for the Residence at Five Creek project. The appearance of the apartment is commensurate with the Fiori Estates apartment development and The Reserve apartment project as well as the Phase I, the Adega Apartment Complex in the Five Creek development. The apartment complex will be an attractive addition to the surrounding area. Special care has been taken to ensure that all buildings within the SAMP have a consistent architectural character. Architecture and site design components give the apartment complex and the entire SAMP neighborhood a consistent look and feel. B.That the development incorporates a variation from adjacent on-site and off-site structures in height, bulk, and area; arrangement on the parcel; openings or breaks in the façade facing the street; and/or the line and pitch of the roof. Criteria Satisfied. The new building has a very attractive appearance with a variety of materials including stucco, fiber cement siding, metal balcony railings, stone veneer and cement tile roof. There is articulation in the building walls and variations in the roof height. The unifying element in the development is a contemporary rustic architecture that brings forward elements of traditional styling combined with modern materials to ensure a timeless architectural character. Low pitched roofs finished with concrete tile and color variation on the stucco walls creates visual movement in the elevation while a mix of materials reinforces the contemporary rustic design and softens the massing of the three-story buildings. Details, including the decorative metal railings and roof brackets, projected window trim, horizontal siding and stone veneer, animate the architecture on all four sides and enhance the overall design. The building design will be consistent with other structures in the SAMP. C.That the development will be located and oriented in such a manner so as to provide pedestrian, bicycle and vehicular connections with adjacent properties, as appropriate, and avoids indiscriminate location and orientation. Criteria Satisfied. Vehicular access to the property is from Martin Avenue, a new private street connecting Dowdell Avenue with Labath Avenue. There is vehicular access to Rohnert Park Expressway and Highway 101. There are bike lanes on Dowdell Avenue and access to the Hinebaugh Creek trail. There is bicycle access to the site from a trail in Hinebaugh Creek and from Rohnert Park Expressway via Redwood Drive. Pedestrian sidewalks will connect all buildings within the Five Creek area and to adjacent properties in the SAMP and the public sidewalk system. Bicycle parking will be provided. Section 3. An Environmental Impact Report (EIR) was prepared for the original Stadium Area Master Plan. Previous changes to the General Plan and SAMP in 2017 triggered additional environmental review consisting of a Mitigated Negative Declaration. There were new mitigation measures largely limited to air quality and greenhouse gas emissions. The current proposed Five Creek project was analyzed under CEQA Section 15162 and it was determined that the conclusions of the previous MN D w ill not change regarding tra ffic and the mitigation measur es beyond w hat w ere already required as part of the appro ved MMRP . As per the pro visions of CEQ A Section 15162, no fur ther environm ental review is required for the Five Creek project Phase II developm ent. NOW THERE FORE BE IT RE SOLVED, that the Planning Commission does hereby appro ve Planning Application N o. PLSR20-0004 subject to the project submittal attached as Exhibit A and the conditions attached hereto as Exhibit B. BE IT FURTHER RE SOLVED that said action shall not be deemed final until the appeal period has expired and that the appeal period shall be ten (10) working days from the date of said action. N o building perm its shall be issued until the appeal period has expired, pro viding there are no appeals. DULY AND REGULARLY ADOPTED on this 25th day of June 2020 by the City of Rohnert Park Planning Com m ission by the fo llow ing vote: AYES: _Ij___ N O ES: _Q_ ABSEN T: _O__A BSTAIN: Q_ BL AN Q U IE ~BO RBA ~ GIUD ICE ¥H AYD ON ~RLOFF-4- Jennife r Sedn Attachm ents: Exhibit A - A pplicant subm ittal package Exhibit B - Conditions of Appro val ,., _) Reso 2020-018 Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 2020A0.1COVER SHEETSHEET INDEXARCHITECTUREA0.1 COVER SHEETA1.0 SITE PLANA2.0 BUILDING ELEVATIONS - BUILDING AA2.1 BUILDING ELEVATIONS - BUILDING AA2.2 BUILDING ELEVATIONS - BUILDING BA2.3 BUILDING ELEVATIONS - BUILDING BA2.4 BUILDING ELEVATIONS - BUILDING CA2.5 BUILDING ELEVATIONS - BUILDING CA3.1 BUILDING PLANS - BUILDING AA3.2 BUILDING PLANS - BUILDING BA3.3 BUILDING PLANS - BUILDING CA3.4 BUILDING PLANS - BUILDING CA5.0 UNIT PLANSA7.0 MATERIAL BOARDA7.1 LIGHT FIXTURE PALETTECIVILC1 NEIGHBORHOOD CONTEXT MAPC2 DIMENSIONED SITE PLANC3 GRADING PLANC4 UTILITY PLANLANDSCAPELA1 PRELIMINARY LANDSCAPE CONCEPTExhibit A to Resolution 26.0'Typ.32.0' xxxxxxxxxxxxxx xxTrans.Trans.21.2'55.9'8.2' 13.2'18.3' 8.2'32.5'32.5'27 .7 '15.0'15.0'17.2'9.5'26.0'Typ.51.5'Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNJUNE 17TH, 202005010025A1.0SITE PLANSHEET INFORMATIONMartin Ave.Trash3 Story Building withtuck-under parking, TypicalTrashPoolTrashDowdell Ave. Labath Ave.Carlson CourtSite AccessBuilding CBuilding CBuilding CBuilding CBuilding BBuilding B-altBuilding ARESIDENTIALPHASE I SITETrashTrash1C2A5A-Alt16A-Alt24A3BCarport, TypicalSite Summary - PHASE II (CURRENT)2.88 Net Acres3.33 Gross Acres73 Units (25.4 du/acre)KEYBuilding No. Building TypeBuilding No. 1 (Type C)Building No. 2 (Type A)Building No. 3 (Type B)Building No. 4 (Type A)Building No. 5 (Type A-Alt1)Building No. 6 (Type A-Alt2)Building Summary1Bd/1Bath2Bd/2Bath3Bd/2Bath Total100505 20050203 10060206 14050203 10050202 09050302 10361621 73Unit SummaryUnit Type Net AreaGross AreaTotalUnit Plan 11 805 SF 890 SF 12 units 16.4%Unit Plan 12 783 SF 864 SF 24 units 32.9%Unit Plan 21 1155 SF 1255 SF 02 units 02.7%Unit Plan 22 1251 SF 1358 SF 14 units 19.2%Unit Plan 31 1310 SF1418 SF21 units 28.7%Total73 unitsParking SummaryResidential Parking Required:1 Bedroom 1 space/ unit 36 spaces2 Bedroom 2 space/ unit 32 spaces3 Bedroom 2 space/ unit 42 spacesGuest 25 spacesTotal 135 spacesParking Provided*:Garage Parking50 spacesCarport Parking24 spacesOpen Parking48 spacesMartin Avenue Parking19 spacesTotal 141 spaces*10% of each on-site parking facility proposed as EVCS capable per CalGreen1AHOTEL PHASESITELeasing Office and Club Room atGrade with Residential AboveMaintenance RoomMail KioskGated EVAEVEVEVEVEVEVEVEVEVEVEVEVEVEVEV - Electric VehicleCharging Station Capable FRONT ELEVATIONLEFT ELEVATIONLEFT - ALT1BUILDING NO. 5LEFT - ALT2BUILDING NO. 6FRONT - ALT1BUILDING NO. 5Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A2.0BUILDING PLANSBUILDING AMATERIAL LEGEND1. Stucco2. Cement Tile Roof3. Fiber Cement Siding4. Stone Veneer5. Vinyl Window6. Metal Rail7. Painted Door8. Fiber Cement Trim42531253816KEY PLAN N.T.S.54714443 REAR ELEVATIONRIGHT ELEVATIONREAR - ALT1BUILDING NO. 5Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A2.1BUILDING PLANSBUILDING AMATERIAL LEGEND1. Stucco2. Cement Tile Roof3. Fiber Cement Siding4. Stone Veneer5. Vinyl Window6. Metal Rail7. Painted Door8. Fiber Cement Trim4215561342KEY PLAN N.T.S.5148 FRONT ELEVATIONLEFT ELEVATIONArchitecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A2.2BUILDING PLANSBUILDING BMATERIAL LEGEND1. Stucco2. Cement Tile Roof3. Fiber Cement Siding4. Stone Veneer5. Vinyl Window6. Metal Rail7. Painted Door8. Fiber Cement Trim7214152534KEY PLAN N.T.S.4411367 REAR ELEVATIONRIGHT ELEVATIONArchitecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A2.3BUILDING PLANSBUILDING BMATERIAL LEGEND1. Stucco2. Cement Tile Roof3. Fiber Cement Siding4. Stone Veneer5. Vinyl Window6. Metal Rail7. Painted Door8. Fiber Cement Trim32845718662KEY PLAN N.T.S.34313681 FRONT ELEVATIONLEFT ELEVATIONArchitecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A2.4BUILDING PLANSBUILDING CMATERIAL LEGEND1. Stucco2. Cement Tile Roof3. Fiber Cement Siding4. Stone Veneer5. Vinyl Window6. Metal Rail7. Painted Door8. Fiber Cement Trim21415142KEY PLAN N.T.S.336871667 REAR ELEVATIONRIGHT ELEVATIONArchitecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A2.5BUILDING PLANSBUILDING CMATERIAL LEGEND1. Stucco2. Cement Tile Roof3. Fiber Cement Siding4. Stone Veneer5. Vinyl Window6. Metal Rail7. Painted Door8. Fiber Cement Trim65132KEY PLAN N.T.S.7213151418 LEVEL 2 & 361'-8"91'-4 1/2"P11P22P12P31ROOF PLANLEVEL 159'-8"P12P3193'-1 1/2"BUILDING NO. 5 - LEVEL 1BUILDING TYPE A-ALT1LobbyClubroomOfficeTech RoomFlex RoomMen'sWomen'sBUILDING NO. 6 - LEVEL 1BUILDING TYPE A-ALT2P21Utility RoomArchitecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A3.1BUILDING PLANSBUILDING A AND ALTERNATES LEVEL 165'-0"128'-9 1/2"P31P12P12P31ROOF PLAN65'-0"123'-11 1/2"LEVEL 2 & 3P31P12P12P31P22Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A3.2BUILDING PLANSBUILDING B LEVEL 159'-8"P12P31P21LEVEL 261'-8"182'-11"189'-4"P11P11P22P12P22UtilitiesP12P31P31P12Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A3.3BUILDING PLANSBUILDING C LEVEL 361'-8"182'-11"ROOF PLANP11P11P22P22P12P31P31P12Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 4 816A3.4BUILDING PLANSBUILDING C Plan 111 Bedroom / 1 Bathroom805 NSF890 GSFLiving/Dining12'-8" x 18'-5"Kitchen12-8" x 9'-2"Master Bedroom11'-0" x 14'-7"Deck7'-10" x 11'-0"79 SQ. FT.BathWICW/DLinLinPlan 121 Bedroom / 1 Bathroom783 NSF864 GSFLiving Room13'-10" x 14'-3"Bedroom 212'-6" x 14'-2"W/DBathWICDining/Kitchen14'-10" x 12'-10"Deck11'-10" x 6'-2"67 SQ. FT.LinBathPlan 212 Bedroom / 2 Bathroom1155 NSF1255 gSFBedroom 211'-0" x 12'-5"M. Bedroom14'-9" x 13'-10"WICLiving/Dining14'-10" x 18'-8"Kitchen17'-6" x 12'-0"LinDeck10'-0" x 6'-8"78 SQ. FT.BathW/DKitchenLiving14'-0" x 17'-0"BathWICPlan 222 Bedroom / 2 Bathroom1251 NSF1358 GSFMaster Bedroom13'-6" x 14'-0"DiningDeck10'-0" x 10'-10"94 SQ. FT. Bedroom 213'-8" x 12'-4"BathLinW/DBedroom 311'-0" x 12'-5"Bedroom 211'-6" x 11'-2"M. Bedroom14'-9" x 11'-10"BathWICLiving/Dining14'-10" x 18'-8"Kitchen17'-6" x 12'-0"Plan 313 Bedroom / 2 Bathroom1310 NSF1418 GSFLinBathDeck10'-0" x 6'-8"78 SQ. FT.27'-1"33'-2"32'-5"27'-4"32'-5"48'-4"29'-1"53'-5"32'-5"48'-4"Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 20200 2 48A5.0ENLARGED BUILDING PLANSUNIT PLANS Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 2020A7.0MATERIAL BOARD Architecture + Planning888.456.5849ktgy.comUSA Properties Fund, Inc.3200 Douglas Blvd., Suite 200Roseville, CA 95661TERRACINA AT ROHNERT PARKROHNERT PARK, CA # 2020-0427CONCEPTUAL DESIGNMAY 22, 2020A7.1LIGHT FIXTURE PALETTETypical Wall SconceTypical Light PostTypical Light BollardDecorative Light WellNote: Proposed site lighting design is to be consistent orsimilar to Phase I. Location and Wattage of proposedlight fixtures to be determined by photometric plan.Decorative Light PostDecorative Light PostTypical Wall Pack TREESBOTANICAL NAMECOMMON NAMEAcer rubrum `Autumn Blaze`Autumn Blaze MapleArbutus x `Marina`Arbutus StandardBrachychiton PopulenusBottle TreeCercis canadensis `Forest Pansy` TM Forest Pansy RedbudCupressus sempervirensItalian CypressGeijera parvifloraAustralian WillowLagerstroemia indica `Muskogee`Muskogee Crape MyrtleOlea europaea `Majestic Beauty` TM Majestic Beauty Fruitless Olive - StndOlea europaea `Wilsonii`Wilson Olive - Multi-TrunkPistacia chinensisChinese PistachePrunus carolinianaCarolina Laurel CherryPyrus calleryana `Chanticleer`Chanticleer PearQuercus agrifoliaCoast Live OakRhaphiolepis indica `Majestic Beauty` TM Indian Hawthorne StandardSequoia sempervirens `Aptos Blue` Aptos Blue RedwoodWashingtonia robustaMexican Fan PalmZelkova serrata `Village Green`Sawleaf ZelkovaPLANT SCHEDULETREESBOTANICAL NAMECOMMON NAMEAcer rubrum `Autumn Blaze`Autumn Blaze MapleArbutus x `Marina`Arbutus StandardBrachychiton PopulenusBottle TreeCercis canadensis `Forest Pansy` TM Forest Pansy RedbudCupressus sempervirensItalian CypressGeijera parvifloraAustralian WillowLagerstroemia indica `Muskogee`Muskogee Crape MyrtleOlea europaea `Majestic Beauty` TM Majestic Beauty Fruitless Olive - StndOlea europaea `Wilsonii`Wilson Olive - Multi-TrunkPistacia chinensisChinese PistachePrunus carolinianaCarolina Laurel CherryPyrus calleryana `Chanticleer`Chanticleer PearQuercus agrifoliaCoast Live OakRhaphiolepis indica `Majestic Beauty` TM Indian Hawthorne StandardSequoia sempervirens `Aptos Blue` Aptos Blue RedwoodWashingtonia robustaMexican Fan PalmZelkova serrata `Village Green`Sawleaf ZelkovaPLANT SCHEDULEInterior InteriorInteriorInterior Interior InteriorInteriorInteriorTrans.Trans.SHRUBSBOTANICAL NAMECONTAbelia x grandiflora `Kaleidoscope`5 galAgapanthus orientalis `BLUE`5 galBerberis thunbergii `Atropurpurea Nana` 5 galBerberis thunbergii `Rose Glow`5 galCallistemon viminalis `Little John`5 galCeanothus maritimus `Valley Violet` 5 galDietes bicolor5 galDodonaea viscosa `Purpurea`5 galFestuca mairei1 galGaura lindheimeri `Passion Blush`1 galJuncus patens `Elk Blue`5 galJuniperus scopulorum `Skyrocket`15 galLoropetalum chinense `Purple Pixie` 1 galMyoporum x `White`1 galNandina domestica `Compacta`5 galNandina domestica `Moon Bay` TM5 galPhormium tenax `Jack Spratt`1 galPhormium tenax `Pink Stripe`5 galPrunus caroliniana `Compacta`5 galRhamnus californica `Eve Case`5 galRhaphiolepis indica `Clara`5 galRosa x `Flower Carpet Coral`2 galSalvia greggii `Lipstick`5 galTeucrium fruticans `Compactum`5 galXylosma congestum `Compacta`5 galGARDEN HERBSBOTANICAL NAMECONTMentha spicata1-QuartOriganum vulgare1-QuartRosmarinus officinalis `Huntington Carpet` 5 galThymus x citriodorus1-QuartSTRAP LEAF PLANTS AND GRASSESBOTANICAL NAMECONTHesperaloe parviflora5 galPhormium tenax `Purpurea`5 galTulbaghia violacea `Silver Lace`1 galGROUND COVERSCODEBOTANICAL NAMECONTSPACINGFES EL2Festuca glauca `Elijah Blue`1 gal 18" o.c.LIR SU2Liriope muscari `Silvery Sunproof` 1 gal 12" o.c.TRA AS2Trachelospermum asiaticum `Asiatic` 1 gal 24" o.c.TRA JASTrachelospermum jasminoides 1 gal 24" o.c.VER ROCVerbena tenuisecta `Purple`1 gal 18" o.c.INERT COVERCODEBOTANICAL NAMECONTSPACINGCMCOBBLE ROCK MULCHSFDGDG TAN GRANITESFGTGRAVEL MULCHSFBMWOOD MULCHSFSOD GRASSESCODEBOTANICAL NAMECONTSPACINGSOD BSSod x `Bio-Swale Mix`SodSOD NBSod x `Native Bentgrass`SodSHRUB AND GROUND COVER SCHEDULE MULTI-FAMILYLandscape Architecture Design By GHD:Scott Robertson, Landscape Architect CA LLA 42710SCALE: feet25'50'75'1" = 25'NORTHPreliminary Landscape Concept (SPAR Review)Rohnert Park, CaliforniaMay 18, 2020 2126UPL006.dwgLA1Developed By: USA Properties FundTERRACINA at Rohnert ParkDESIGN INTENT NOTE:The intent of this exhibit is to generally illustrate the landscape areas. It is not a representation of the final layout oftrees, plant materials, or amenities. The Plant Palette is reflective of the immediately adjacent Apartments .CALGreen+Tier 1 ChecklistThe design of the landscape / irrigation systemis intended to meet the CALGreen+Tier 1Checklist associated with landscape elements.Toward this end the project will include thefollowing best practices:1. Lawn grass area, limited to not more than50% of the landscape, shall be irrigated by a lowvolume pop-up rotary sprinkler system.2. Hydrozone irrigation techniques will beincorporated.3. The plant palette will utilize at least 75%native California or drought tolerant plantmaterials appropriate to the climate zone region.Note: Plant list illustrated is tentative and mayexpand or contract as the final design isprepared.4. The use of potable water will be reduced to aquantity that does not exceed 65% of ETo timesthe landscape area.5. Common area and perimeter area landscapeirrigation will consist of a combination of waterconserving low volume rotary sprinklers (whereappropriate in large ground cover areas),traditional drip irrigation, and an in-line dripirrigation system.6. All irrigation valves shall be connected to anautomatic control system.7. All irrigation systems shall be designed tomeet the most current water conservationpolicies and available equipment.8. WELO Calculations to be provided at finaldesign submittal for improvement plans.Plant Container Sizing·Trees to be planted from minimum15-gallon size containers·Shrubs to be planted from 5-gallon and1-gallon containers·Ground Covers to be planted from1-gallon containers·Lawn areas to be planted from sodDESIGN NOTEThe Plant List is tentative and may expand orcontract as the final planting design is prepared.PROPOSED STREETDOWDELL AVENUECITY PROPERTY1TREE SCHEDULECARPORTCARPORTHOTEL SITEADJACENT APARTMENT SITETRASHTRASHADJACENT APARTMENT SITEMAIL CARPORTCARPORTWATER QUALITYBASINS OF SWALES,TYPSIGN MONUMENTEXISTING FENCE TO REMAINEXISTING FENCE TO REMAINPROPOSED E.V.A. GATEPROPOSEDFENCEPROPOSEDFENCE23456SIGN MONUMENT CONCEPTFENCING BETWEEN HOTEL AND PROJECTmin.TOT-LOT AREA PROGRAM·BBQ (Propane)·Picnic Table·Tot-lot Structure for ages 2-12 yearsTRASH ENCLOSURE WITH ROOFFLAG POLELOCATION Exhibit B to Resolution Terracina SPAR COAs 1 Conditions of Approval Site Plan and Architectural Review Terracina at Rohnert Park The conditions below shall apply to Terracina at Rohnert Park located within the Stadium Area Master Plan and subject to the requirements of the Residences at Five Creek Final Development Plan on Dowdell Avenue and Martin Avenue (PLSR20-0004). General Conditions 1. The Site Plan and Architectural Review approval shall expire one year from the Planning Commission approval date, unless prior to the expiration a building permit is issued and construction is commenced and diligently pursued toward completion and the use is initiated, or an extension is requested and approved. 2. All applicable provisions of the City of Rohnert Park Municipal Code, and as subject to the Residences at Five Creek Development Agreement (DA) approved by Ordinance No. 903 as amended, are made a part of these conditions of approval in their entirety, as if fully contained herein. 3. The violation of any condition listed herein shall constitute a nuisance and a violation of the RPMC. In conformity with Chapter 1.16 of the RPMC, a violation of the RPMC may be an infraction or a misdemeanor and shall be punishable as provided by law. In addition to criminal penalties, the City may seek injunctive relief. The Applicant agrees to pay for all attorney’s fees and costs, including, but not limited to, staff time incurred by the City in obtaining injunctive relief against the Applicant as a result of a failure of the Applicant to fully perform and adhere to all of the Conditions of Approval. 4. The Applicant agrees to defend, indemnify, hold harmless and release the City of Rohnert Park, its agents, officers, attorneys and employees from any claim, action or proceedings brought against any of the above, the purpose of which is to attack, set aside, void, or annul the approval of this application or certification of the environmental document which accompanies it. This indemnification obligation shall include but not be limited to, damages, costs, expenses, attorneys’, or expert witness fees that may be asserted by any person or entity, including the Applicant, whether or not there is concurrent passive or active negligence on the part of the City, its agents, officers, attorneys or employees. 5. Place Conditions of Approval on general notes on plan sheets. Project Design Conditions 6. The project shall be designed, approved and installed to be consistent with the overall buildout of the Residences at Five Creek Final Development Plan, the Stadium Lands P- D Zoning District, the RPMC and the City of Rohnert Park General Plan and shall comply with all applicable mitigation measures established in the Mitigation Monitoring Program adopted for the Project. Costs of implementing and monitoring the mitigation measures shall be borne by the Applicant and any successors-in-interest. 7. The project applicant shall incorporate the following GHG reduction measures into the project design: Exhibit B to Resolution Terracina SPAR COAs 2 • Compliance with the applicable Title 24 energy efficiency standards at the time of development. At a minimum, compliance with the 2016 Title 24 standards • Compliance with state and/or local green building standards. At a minimum, implementation of CALGreen Tier 1 standards • Installation of high efficiency LED lights in outdoor areas • Participation in a Transportation Demand Management Program • Improvement the pedestrian network and implementation traffic calming measures throughout the project • Diversion of solid waste diversion consistent with AB 341 • Inclusion of shade canopies over parking lots, where appropriate and feasible • Provision of information regarding transit availability to residents and employees • Provision of carpool and/or car sharing parking spaces (not applicable to residential portion of the project) • Provision of electric vehicle parking • Compliance with the City bicycle master. 8. Landscaping shall be constructed in accordance with the State’s Model Water Efficient Landscaping Ordinance (MWELO), or in accordance with water conservation standards which meet or exceed the requirements of the MWELO. The Applicant shall submit a landscaping and irrigation plan that identifies landscape material types and locations, irrigation, water usage calculations, and other information as required. The plan shall be submitted and reviewed by the Development Services Department with each phase of the project. All costs for review of the requirements of the MWELO shall be borne by the Applicant. All landscaping and irrigation subject to the MWELO shall be substantially complete prior to the issuance of a Certificate of Occupancy. 9. The applicant shall submit and receive approval according the Municipal Code prior to installation of any signs. 10. All exterior lighting shall be LED including wall lights on the building. 11. Any new trees within five (5) feet of the public right-of-way or within five (5) feet of any paved areas within the project shall have root barriers that are approved by the City Engineer. 12. The applicant shall file an Administrative Use Permit in accordance with Municipal Code Section 17.07.020, H. Density Bonus for Affordable Housing, for the reduction of the front yard setback. PUBLIC SAFETY CONDITIONS Exhibit B to Resolution Terracina SPAR COAs 3 13. Fire sprinklers will be required per NFPA 13 and local ordinance. 14. A fire alarm system is required per NFPA 72 and local ordinance. Communications path for monitoring should be either IP or radio. The system meet the requirements of NFPA 72, Section 26.3 and local ordinance for maintenance and operation. 15. Separate Fire Department permits will be required for EVA gate, fire sprinklers and alarm system. 16. Provide a key box for emergency responders’ use. Boxes may be purchased from the Fire Prevention Division by calling (707)584-2641. One box is required for each building. 17. Address shall be illuminated and visible from the street per local ordinance. 18. Provide signage, which identifies all fire service equipment location. 19. Provide signage on gate which reads “FIRE LANE – NO PARKING” on both sides of the gate with a 4” red stripe on the pavement. 20. If the trash enclosures are non-combustible construction, fire sprinklers will not be required in them. 21. Show fire truck turning radii on improvement plans. 22. The layout of the fire service appears acceptable. Final layout and main sizes will be determined and reviewed under the improvement plans review. 23. A fire hydrant flow test should be performed to establish the existing water availability. Please contact the fire Prevention Division to arrange for a hydrant flow test. (707)584- 2641. 24. Additional conditions may be applied as the project develops. Grading and Improvement Plan Requirements 25. All improvements shall be designed in conformance with: the City of Rohnert Park, Manual of Standards, Details and Specifications in effect at the time of development; the Residences at Five Creeks Final Development Plan; and the conditionally approved tentative map for the Residences at Five Creeks. 26. The Project benchmark shall be based on a City approved USGS benchmark. 27. Mailbox plans and locations shall be approved by the Rohnert Park Postmaster prior to improvement plan approval. The applicant shall provide a letter and exhibit showing mailbox locations from the Rohnert Park Postmaster approving mailbox locations. Exhibit B to Resolution Terracina SPAR COAs 4 28. The applicant shall submit a geotechnical study conducted by an engineer licensed in the State of California and qualified to perform soils work, or a California Certified Geologist and acceptable to the City. Recommendations shall be provided, as necessary, to prevent damage to Project facilities and compliance with these recommendations shall be required as a condition of development at the Project site. The grading and improvement plans shall incorporate the recommendations of the approved geotechnical study. This geotechnical study shall at a minimum evaluate the following: a. The liquefaction potential at the Project site. b. The location and extent of expansive soils at the Project site, including recommendations regarding the treatment and/or remedy of on-site soils, and the structural design of foundations and underground utilities. c. Seismic safety including recommendations regarding the structural design of foundations and underground utilities. 29. The plans shall be prepared by a Registered Civil Engineer, licensed in the State of California and shall be submitted for review and approval by the City Engineer. 30. The plans shall clearly show all existing survey monuments and property corners and shall state that they shall be protected and preserved. 31. The improvement plans shall illustrate public street frontage improvements, grading, paving, utilities, and drainage structures to be built, lighting and trash collection. The improvements plans shall include parking lots, street and utility information including all concrete curb and gutter, sidewalk, street lights, striping and signing, paving, water lines, storm drain lines and sewer lines as necessary, erosion control and any necessary transitions. 32. Improvements plans shall include an erosion control (winterization) plan. The plan must include an order of work and staging/scheduling component indicating when facilities must be installed and when they may be removed. A separate Rain Event Action Plan (REAP) shall be required and prepared as part of the Storm Water Pollution Prevention Plan (SWPPP). A copy of the REAP shall be kept on-site throughout the duration of construction activities. 33. The Improvement Plans shall include the following required notes: a. "Any excess materials shall be considered the property of the contractor and shall be disposed of away from the job side in accordance with applicable local, state and federal regulations." b. "During construction, the Contractor shall be responsible for controlling noise, odors, dust and debris to minimize impacts on surrounding properties and roadways. Contractor shall be responsible that all construction equipment is equipped with manufacturers approved muffler's baffles. Failure to do so may result in the issuance of an order to stop work." c. "If at any time during earth disturbing activities a concentration of artifacts or a cultural deposit is encountered, work shall stop in the immediate area Exhibit B to Resolution Terracina SPAR COAs 5 and the construction manager shall contact the City and a qualified archeologist.” d. “If human remains are encountered anywhere on the project site, all work shall stop in the immediate area and the construction manager shall contact the City, the County Coroner and a qualified archeologist.” e. “If paleontological resources or unique geologic features are encountered during construction, all work shall stop in the immediate area and the construction manager shall contact the City and a qualified paleontologist.” f. "Construction work hours shall be consistent with the Rohnert Park Municipal Code, Noise Ordinance. g. "All existing overhead utilities (of 26,000 volts or less) and proposed utilities, both on-site and along project frontages, shall be placed underground. This does not include surface mounted transformers, pedestal mounted terminal boxes and meter cabinets." h. "If hazardous materials are encountered during construction, the contractor will halt construction immediately, notify the City of Rohnert Park, and implement remediation (as directed by the City or its agent) in accordance with any requirements of the North Coast Regional Water Quality Control Board." i. "The contractor(s) shall be required to maintain traffic flow on affected roadways during non-working hours, and to minimize traffic restriction during construction. The contractor shall be required to follow traffic safety measures in accordance with the Cal Trans "Manual of Traffic Safety Controls for Construction and Maintenance Work Zones." The City of Rohnert Park emergency service providers shall be notified of proposed construction scheduled by the contractor(s) in writing and at least 24 hours in advance of its proposed schedule of work." 34. Sidewalk warps shall be provided to allow a clear five foot walkway at all locations, including areas where mailboxes, streetlights, street signs and fire hydrants are to be installed. 35. One-inch chases shall be installed to all parkway strips from adjacent parcels to allow for the installation of irrigation lines in the future. 36. The improvement plans shall illustrate handicap ramps and parking as required by State of California Title 24. 37. Driveway entrances shall be designed to meet the requirements of the City Standards and the City Engineer. All driveways shall be per City standards for commercial developments. 38. Street lighting shall be designed in accordance with City of Rohnert Park and PG&E requirements. Street light design, spacing, and locations shall be approved by the City Exhibit B to Resolution Terracina SPAR COAs 6 Engineer. Electrical service points shall be shown on the plans based on PG&E provided locations. 39. Landscape plans shall be submitted with the civil improvement plans. Sidewalk alignment shall be shown on both the civil and landscape plans. 40. The existing rock-lined bio-swales in the public right-of-way along the Dowdell Avenue frontage shall be landscaped. Any trees planted in or near the bio-swale area may not interfere with the storm drain pipes located in the swales. 41. Site design shall include pedestrian pathways and crossings connecting onsite activity centers. 42. The improvement plans shall show bicycle racks on-site in accordance with City Standards, which require individually mounted inverted-U-shaped racks. The number of bicycled parking spaces shall be consistent with the MND. 43. The site design shall include adequate fire lanes and other emergency facilities as determined by Department of Public Safety including any NO PARKING lanes, turnarounds, or other features as required by the Rohnert Park Department of Public Safety. Hydrology, Storm Water and Storm Drain 44. The applicant shall submit to the City of Rohnert Park for review and approval, drainage plans, hydrologic, and hydraulic calculations pipe sizing and storm drain plans prepared by a Registered Civil Engineer licensed in the State of California. The drainage plans and calculations shall indicate the following conditions before and after development: a. A site-specific hydrology and drainage study acceptable to the City showing the increase in storm water runoff that would result from development of the Project site. b. Quantities of water, water flow rates, drainage areas and patterns and drainage courses. c. Hydrology shall be per current Sonoma County Water Agency Standards. 45. The improvement plans shall reflect the results of the hydraulic study. The storm drain system shall be designed to meet the requirements of the Sonoma County Water Agency Flood Control Design Criteria (latest revision), specific to the Project and these conditions. 46. The improvement plans shall incorporate features and design such that there shall be no net change in the storm water peak in the 85% - 24 hour storm event. 47. The applicant shall prepare and implement a site specific storm water pollution prevention plan acceptable to the City that identifies best management practices for effectively reducing discharges of storm water containing sediment and construction wastes resulting from site construction activities. The applicant shall comply with all other requirements set forth in City’s stormwater permit. Exhibit B to Resolution Terracina SPAR COAs 7 48. The improvement plans shall be in conformance with the City of Santa Rosa and Sonoma County Storm Water Low Impact Development Technical Design Manual (latest edition). The plans shall be in general conformance with the Preliminary Storm Water Mitigation Plan for The Residences at Five Creek, prepared by Civil Design Consultants, Inc., July 2016. The final improvement plans shall include a tributary area map showing how each portion of the site is directed to a treatment measure. 49. Discharge of runoff onto pavement should be avoided. 50. The improvement plans shall include storm drainage improvements to remove oil and grease from discharges from parking lots, including directing runoff to vegetated swales or areas, consistent with best management practices (BMPs). 51. The site plans shall show all private storm drains serving adjacent property (ies) and those storm drains shall be contained within private storm drain easements in favor of adjacent property (ies). 52. All project related flooding impacts shall be mitigated by the project applicant. Drainage improvements shall be designed by a Civil Engineer registered in the State of California in accordance with the Sonoma County Water Agency's Flood Control Design Criteria. Public and private drainage improvements shall be shown on the improvement plans and shall be approved by the Sonoma County Water Agency (SCWA) prior to approval by the City Engineer. 53. No lot to lot drainage is allowed. No concentrated drainage may discharge across sidewalks. All site drains must be connected to the public storm drain system, or discharged through the face of curb or to an established waterway. A minimum of two curb drains will be required to drain residential lots. 54. Plans and certifications shall demonstrate compliance of all improvements, including building pads and finished floor elevations, with the City's Flood Plain Ordinance, to the satisfaction of the Building Official and City Engineer. Pad elevations shall be constructed at a minimum of 1 foot above the 100-year Floodplain as determined by the City and certified by the project engineer. 55. Site drainage design must include facilities for the containment of recycled water runoff due to over irrigation, system leakage or control failure. Water System Requirements 56. The water system improvement plans shall be accompanied by a hydraulic model run, or alternative form of calculation, demonstrating that the fire flows and pressures required for the project, including the hotel element, can be achieved with the proposed water system improvements. These calculations are subject to the approval of the City Engineer and Fire Marshall. 57. The improvement plans shall show backflow prevention devices in accordance with the requirements of the City of Rohnert Park's Backflow Prevention Ordinance. 58. The applicant shall indicate in writing to the City of Rohnert Park the disposition of any water well(s) and any other water that may exist within the site. All wells shall be Exhibit B to Resolution Terracina SPAR COAs 8 abandoned, properly sealed, and destroyed in accord with State of California Health Department Requirements. 59. Each individual multifamily unit shall be sub-metered off a master City water meter. 60. The improvement plans shall show water services to the building. All water meters shall be located within the right-of-way unless otherwise approved by the Development Services Department. The improvement plans shall show fire protection in accordance with the requirements of Rohnert Park Fire Department. 61. The improvement plans shall show hydrants placed per the direction of the Rohnert Park Fire Division. 62. The improvement plans shall include a note that states "All hydrants shall be covered with bags indicating that the hydrant is not active until flow tests are completed by the City and the hydrants are approved." Sewer System Requirements 63. The improvement plans shall show any existing septic systems on the property and state they shall be abandoned in accordance with the requirements of the Sonoma County Public Health Service. 64. The improvement plans shall illustrate any grease traps required for commercial kitchen facilities in accordance with the requirements of the Santa Rosa Subregional System and the City of Rohnert Park Design Standards. 65. Sanitary sewer connections shall be provided to the floor sump in all trash dumpster enclosures. 66. A sanitary sewer application shall be submitted to the Development Services for review and approval. Application shall indicate the type of discharge proposed. 67. The improvement plans shall show that all manholes shall be provided with a gasket. 68. Sewer grades must be designed such that ultimate finished floors are a minimum of 12" above upstream manhole or clean-out rim elevations Recycled Water System Requirements 69. The improvement plans shall show recycled water use for irrigation. 70. The recycled water system improvements shall be designed in accordance with the City of Santa Rosa’s Recycled Water Users Guide, the City of Santa Rosa and City of Rohnert Park standards, Title 22 of the California Code of Regulations and the requirements of the North Coast Regional Water Quality Control Board. 71. All recycled water mains, service laterals, plumbing, valves, pipes, appurtenances, irrigation parts, vaults and boxes must be purple. Recycled water notification signs shall be installed as directed by the City Engineer. Recycled water spray, mists and ponding must not be present in any designated eating area. All drinking fountains must be positioned or shielded to eliminate any exposure to recycled water sprays or mists. Exhibit B to Resolution Terracina SPAR COAs 9 72. Recycled water/potable water dual plumbing design and layout, construction-installation and final inspection review for individual lots or grouping of lots must be performed by an AWWA certified Cross Connection Specialist and all deficiencies must be corrected at the applicant’s expense. Written reports of the Cross Connection Specialist's finding must be submitted to and approved by the City. Dry Utility System Requirements 73. Utility plans within existing or proposed public right-of-way for electric, gas, telephone, cable and fiber optic (joint trench) shall be submitted to the City Engineer for review. All above-ground structures shall be specifically approved by the Director of Development Services. 74. Improvement plans shall show that all utility distribution facilities, including any existing overhead utilities (of 26,000 volts or less) along the project frontage, shall be placed underground or removed, except surface-mounted transformers, pedestal mounted terminal boxes, meter cabinets, fire hydrants and street lights. Appropriate easements shall be provided to facilitate these installations. Prior to the Issuance of Grading Permits 75. No construction activity may commence until the applicant has demonstrated to the City that it has filed a Notice of Intent to comply with the Terms of General Permit to Discharge Storm Water Associated with Construction Activity (NOI) with the State of California Water Resources Control Board. 76. The applicant shall secure an encroachment permit from the City prior to performing any work within the City right of way or constructing a City facility within a City easement. 77. If the site will require import or export of dirt, the applicant shall submit in writing the proposed haul routes for the trucks and equipment. The haul routes must be approved by the City prior to import/export work commencing. 78. For a grading permit, the applicant shall secure an approval of a grading plan prepared by a Registered Civil Engineer licensed in the State of California, pay all required fees and post sufficient surety guaranteeing completion. Prior to the Issuance of the First Building Permit 79. A lot line adjustment application shall be submitted and approved by the City to amend the parcel line between the hotel and the residential parcel. The adjustment should move the hotel parcel line to the east so that all required hotel parking is contained on the hotel parcel. The applicant shall coordinate with hotel parcel owner and provide City with verification that all parking and drainage modifications and revisions to the hotel’s Master Maintenance Agreement have been completed to support the lot line adjustment. 80. An executed and Recorded Emergency Vehicle Access (EVA) agreement from the owner of the northerly apartment complex shall be submitted to the City. The applicant shall coordinate with northerly apartment complex owner and provide City with verification that all site plan modifications and revisions to the apartment’s Master Maintenance Agreement have been completed to support the EVA. Exhibit B to Resolution Terracina SPAR COAs 10 81. The applicant shall provide pad certifications for the site on which the building permit is requested. 82. The applicant shall pay all applicable inspection and development impact fees. 83. The applicant shall provide proof of payment of any impact fees required by the school district that serves the property. 84. The applicant shall demonstrate adequate fire flows for the project to protect combustible construction in accordance with the Municipal Code and to the satisfaction of the City’s Fire Marshall. 85. The applicant shall implement the following CALGreen requirements: a. Review page 4 Residential and Commercial Summary Table and identify the location of the features listed on page 18 figure 17. b. For the residential project provide electric vehicle and bicycle parking (A4.106.8 Electric vehicle (EV) charging and A4.106.9 Bicycle parking). c. Provide addition CalGreen implementation as required by the project MMRP. During Construction 86. All construction shall conform to the City's most current Manual of Standards, Details, and Specifications latest edition, all City Ordinances and State Map Act and the approved plans. 87. The applicant shall complete all water and wastewater improvements, including pressure and bacterial testing and raising manholes and cleanouts to grade prior to connection of any improvements to the City water or wastewater systems. 88. If any hazardous waste is encountered during the construction of this project, all work shall be immediately stopped and the Sonoma County Environmental Health Department, the Fire Department, the Police Department, and the Development Services Inspector shall be notified immediately. Work shall not proceed until clearance has been issued by all of these agencies. 89. Prior to final preparation of the sub-grade and placement of base materials, all underground utilities shall be installed and service connections stubbed out behind the sidewalk. Public utilities, Cable TV, sanitary sewers, and water lines, shall be installed in a manner which will not disturb the street pavement, curb, gutter and sidewalk, when future service connections or extensions are made. 90. Prior to placing the final lift of asphalt, all public sanitary sewer lines shall be video inspected at the expense of the contractor/applicant. All video disks shall be submitted to the City. If any inadequacies are found, they shall be repaired prior to the placement of the final lift of asphalt. 91. The applicant shall be responsible to provide erosion and pollution control in accordance with the approved plans and permits. Exhibit B to Resolution Terracina SPAR COAs 11 92. The applicant shall keep adjoining public streets free and clean of project dirt, mud, materials, and debris during the construction period. 93. If grading is to take place between October 15 and April 15, both temporary and permanent erosion control measures, conforming to the project erosion control plans shall be in place before October 1st. Erosion control measures shall be monitored and maintained continuously throughout the storm season. 94. The following minimum Best Management Practices (BMPs) shall be required during construction: a. Construction crews shall be instructed in preventing and minimizing pollution on the job. b. Construction entrances/exits shall be stabilized to prevent tracking onto roadway. c. Exposed slopes shall be protected from erosion through preventative measures. d. Use brooms and shovels when possible to maintain a clean site e. Designate a concrete washout area. Maintain washout area and dispose of concrete waste on a regular basis. f. Establish a vehicle storage, maintenance, and refueling area. g. Protect drain inlets from receiving polluted storm water through the use of filters such as fabrics, gravel bags or straw wattles. h. Have necessary materials onsite before the rainy season. i. Inspect all BMPs before and after each storm event. Maintain BMPs on a regular basis and replace as necessary, through the entire course of construction. j. All construction implementation measures as outlined in the MMRP. 95. Where soil or geologic conditions encountered in grading operations are different from that anticipated in the soil and/or geologic investigation report, or where such conditions warrant changes to the recommendations contained in the original soil investigation, a revised soil or geologic report shall be submitted for approval by the City Engineer. It shall be accompanied by an engineering and geological opinion as to the safety of the site from hazards of land slippage, erosion, settlement, and seismic activity. 96. The Project shall comply with the City's Municipal Code, including hours of construction. All construction equipment shall be adequately muffled and properly tuned in accordance with manufacturer's specifications. All equipment shall be checked by a certified mechanic and determined to be running in proper condition prior to operation. 97. Hours of work shall be limited to between 8 a.m. to 6 p.m. Monday through Friday. Work on Saturday or Sunday will only be permitted with written permission from the City. Requests for extended hours must be submitted 72 hours in advance. Exhibit B to Resolution Terracina SPAR COAs 12 98. Throughout the construction of the project, dust control shall be maintained to the satisfaction of the City, including all measures in the MMRP and the contractor shall be responsible to implement reasonable measure to cure any problems that may occur. At a minimum the dust control measures will include: • Cover all trucks hauling construction and demolition debris from the site. • Water on a continuous as-needed basis all earth surfaces during clearing, grading, earthmoving, and other site preparation activities. • Use watering to control dust generation during demolition of structures or break- up of pavement. • Pave, apply water three times daily, or apply (non-toxic) soil stabilizers on all unpaved parking areas and staging areas. • Sweep daily (with water sweepers) all paved areas and staging areas. • Provide daily clean-up of mud and dirt carried onto paved streets from the site. • Renovation, demolition activities, removal or disturbance of any materials that contain asbestos, lead paint or other hazardous pollutants will be conducted in accordance with BAAQMD rules and regulations. • Properly maintain all construction equipment. • For construction sites near sensitive receptors (or if residential development occurs prior to commencement of commercial development): • Install wheel washers for all existing trucks, or wash off the tires or tracks of trucks and equipment leaving the site. • Suspend dust-producing activities during periods when instantaneous gusts exceed 25 mph when dust control measures are unable to avoid visible dust plumes. • Limit the area subject to excavation, grading and other construction or demolition activity at any one time. • For sites greater than four acres: • Apply soil stabilizers to previously graded portions of the site inactive for more than ten days or cover or seed these areas. • Water or cover stockpiles of debris, soil, sand, or other materials that can be blown by the wind. • Limit traffic speeds on unpaved roads to 15 mph. • Replant vegetation in disturbed areas as soon as possible. 99. Idling times shall be minimized either by shutting equipment off when not in use or reducing the maximum idling time to five minutes (as required by the California airborne toxics control measure Title 13, Section 2485 of California Code of Regulations). Clear Exhibit B to Resolution Terracina SPAR COAs 13 signage regarding idling restrictions shall be provided for construction workers at all access points. 100. The prime construction contractor shall post a publicly visible sign with the telephone number and person to contact at the construction site and at the City of Rohnert Park regarding dust complaints. The prime construction contractor shall respond and take corrective action within 48 hours. The Air district's phone number shall also be visible to ensure compliance with applicable regulations. 101. Construction firms shall be required to post signs of possible health risk during construction. The developer is responsible for compliance with the BAAQMD rule regarding cutback and emulsified asphalt paving materials. In addition, the construction contractors will implement a plan to use newer construction equipment that meets the NO x emissions standard of 6.9 grams per brake-horsepower hour for work constructed within 200 feet of residences. 102. The project applicant shall ensure that construction contract specifications include a requirement that all off-road diesel-powered construction equipment used for project development with engines greater than 50 horsepower be equipped with a Level 3 Verified Diesel Emissions Control (VDEC). 103. If the existing city streets are damaged during construction, the contractor/applicant shall be responsible for repair at no cost to the City. 104. If, during construction, the contractor damages any existing facilities on the neighboring properties (i.e. fences, gates, landscaping, walls, etc.) contractor shall be responsible to replace all damaged facilities. Prior to Occupancy 105. All improvements shown on the Improvement Plans shall be completed. 106. The applicant shall have entered into the City’s standard Master Maintenance Agreement with the City to address long term maintenance of, among other things, the stormwater BMPs. 107. The applicant shall have entered into the City’s standard Recycled Water Agreement, designate site supervisor(s) and undertake any other activities necessary. 108. The applicant shall have completed the formation of a community facilities district or other maintenance and services funding district to discharge the annual residential maintenance payment outlined in the Development Agreement. 109. The applicant shall provide a written statement signed by his or her engineer verifying that the grading and/or drainage improvements are completed in accordance with the plans approved by the Sonoma County Water Agency, the City Engineer, and the Building Official. 110. Approved Record Drawings shall be provided to the City in hard copy and as geo- referenced in Autocad DWG and & PDF File formats. Page 1 City of Rohnert Park Planning Commission Report MEETING DATE: July 8, 2021 ITEM NO: 6.2 PREPARED BY: Suzie Azevedo, Assistant Planner AGENDA TITLE: PLTX21-0002 – Renewal of Site Plan and Architectural Review for the Green Acre Nursery and Supply Addition and Remodel LOCATION: 4601 Redwood Drive, APN 045-055-023 OWNER/ APPLICANT: Mike Deutsch/Green Acre Nursery and Supply RECOMMENDED ACTION: Staff recommends that the Planning Commission adopt a Resolution approving a one-year extension of Site Plan and Architectural Review (SPAR) for the Green Acre Nursery and Supply Addition and Remodel located within the C-R/Regional Commercial district at 4601 Redwood Drive, APN 045-055-023. (Figure 1) Figure 1 – Project Location Page 2 BACKGROUND: The subject property is a 4.5 acre parcel located on the west side of Redwood Drive, south of and contiguous to Millbrae Avenue and north of and contiguous to Wal-Mart. The property is currently developed with a single story, 42,000+ sq. ft. commercial building previously occupied by Driven Raceway. On June 25, 2020, the applicant, Green Acre Nursery and Supply, received Planning Commission approval for Site Plan and Architectural Review for an exterior remodel and addition of an outdoor display area. The SPAR approval expires one year from the Planning Commission approval date, unless prior to the expiration a building permit is issued and construction is commenced and diligently pursued toward completion OR an extension is requested and approved. The applicant applied for a one-year time extension for the Site Plan and Architectural Review on June 3, 2021. The application was received prior to the expiration date of June 25, 2021 and the matter is being brought before the Planning Commission for its consideration. ANALYSIS: Pursuant to Zoning Ordinance Section 17.25.035, Lapse of Approval/Renewal for Site Plan and Architectural Review approvals, the following shall apply: A. A Site Plan and Architectural Review approval shall lapse one year after the date of final approval or at an alternative date specific at the time of approval, unless 1. A building permit has been issued and construction has diligently commenced; or 2. A Certificate of Occupancy has been issued; or 3. The use is established; or 4. The Site Plan and Architectural Review approval is renewed in accordance with subsection B below. B. A Site Plan and Architectural Review approval may be renewed for an additional period of one year provided that prior to the expiration date, an application for renewal is filed with the Planning Commission. The Commission shall not deny the renewal request without first holding a Public Hearing and making findings supporting the reason for denial. If the Planning Commission denies the renewal request, the applicant shall have ten calendar days to appeal the decision to the City Council as set forth in Chapter 17.25 Article XII. As previously noted, the applicant has filed the necessary application pursuant to this provision. The applicant has indicated that they are working through Covenants, Conditions & Restrictions (CC&R’s) matters with the property owner and Walmart, which has delayed the filing of permits and start of construction. The applicant has been asked to provide an up to date status and project timeline at the July 8, 2021 meeting. Staff would like to note that there have been no changes to the approved plans or surrounding area and the project will remain subject to the conditions as outlined in Resolution 2020-017, adopted by the Planning Commission on June 25, 2020. Page 3 ENVIRONMENTAL DETERMINATION: This project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA), under the CEQA guidelines as both a Class 1, Section 15301 modification of an existing facility. PUBLIC NOTIFICATION: A public hearing notice denoting the time, date and location of the proposal’s hearing was published in the Community Voice. Property owners within 300 feet of the project site were mailed notices, and the notice was posted pursuant to State Planning Law. RESPONSE TO NOTIFICATION: No public comments have been received on this item. _____________________________________________________________________________ Planning Manager Approval Date: 6/30/21 Attachments (list in packet assembly order): A. Planning Commission Resolution 2021-10  Exhibit 1 – Resolution No. 2020-017, adopted June 25, 2020 PLANNING COMMISSION RESOLUTION NO. 2021-10 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK APPROVING A ONE-YEAR EXTENSION OF THE APPROVAL OF SITE PLAN AND ARCHITECTURAL REVIEW FOR THE GREEN ACRES NURSERY ADDITION AND REMODEL LOCATED AT 4601 REDWOOD DRIVE (APN 045-055-023) WHEREAS, the City processed an application for Site Plan and Architectural Review (Planning Application No. PLSR20-0003) for the Green Acres Nursery Addition and Remodel Project located at 4601 Redwood Drive (“Project”) in the time and manner prescribed by State and local law; and WHEREAS, on June 25, 2020, the Planning Commission of the City of Rohnert Park approved the Site Plan and Architectural Review of the Green Acres Nursery Project; and WHEREAS, the applicant, Mike Deutsch, Green Acre Nursery has submitted an application for a one-year time extension of the approval for Site Plan and Architectural Review pursuant to Section 17.25.035B. Lapse of Approval/Renewal of the Rohnert Park Municipal Code; and WHEREAS, public hearing notices were mailed to all property owners within a 300 foot radius of the subject property and to all agencies and interested parties as required by California State Planning Law, and a public hearing was published for a minimum of 10 days prior to the first public hearing in the Community Voice; WHEREAS, on July 8, 2021, the Planning Commission held a public meeting at which time interested persons had an opportunity to testify either in support or opposition to the proposed time extension for the Site Plan and Architectural Review; and WHEREAS, the Planning Commission, using their independent judgment, reviewed the time extension request and all evidence in the record related to the proposed project including the staff report, public testimony, and all evidence presented both orally and in writing. NOW, THEREFORE, BE IT RESOLVED that the Planning Commission of the City of Rohnert Park, California, hereby makes the following findings: A. The Planning Commission, at a public hearing on July 8, 2021 reviewed the applicant’s request for a one-year extension of the approval of Site Plan and Architectural Review for the Project, and all evidence in the record related to the Project including the staff report, public testimony, and all evidence presented both orally and in writing. B. The Planning Commission finds that a one-year extension of the approval of the Site Plan and Architectural Review for the Project is consistent with the approved plans and with the Rohnert Park Municipal Code Section 17.25.035.B. 2 Reso 2021-10 C. The Planning Commission finds that a one-year extension of the approval of the Site Plan and Architectural Review does not necessitate further environmental review of the Project under CEQA, because the project is exempt under CEQA Section 15301 modification of an existing facility. NOW THEREFORE BE IT FURTHER RESOLVED, that the Planning Commission does hereby approve the applicant’s request for a one-year extension of the approval of Site Plan and Architectural Review for the Green Acres Nursery Project located at 4601 Redwood Drive subject to the following conditions: 1. The applicant shall comply with all applicable sections of the City of Rohnert Park Municipal Code. 2. The Project remains subject to the conditions as outlined in Resolution 2020-017, adopted by the Planning Commission on June 25, 2020 and attached hereto as Exhibit 1. 3. The applicant shall secure all necessary permits and clearances from the Rohnert Park Building and Engineering Departments prior to commencement of construction. DULY AND REGULARLY ADOPTED on this 8th day of July, 2021 by the City of Rohnert Park Planning Commission by the following vote: AYES: _____ NOES:_____ ABSENT:_____ ABSTAIN:_____ AUSTIN-DILLON_____ BLANQUIE____ LAM____ ORLOFF____ STRIPLEN____ Mark Orloff, Chairperson, City of Rohnert Park Planning Commission Attest: ________________________________ Jennifer Sedna , Recording Secretary Exhibit 1 – Planning Commission Resolution 2020-017 PLANNING COMMMISSION RESOLUTION NO. 2020-017 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK APPROVING SITE PLAN AND ARCHITECTURAL REVIEW FOR THE GREEN ACRE NURSERY AND SUPPLY ADDITION AND REMODEL LOCATED AT 4601 REDWOOD DRIVE (APN 045-055-023) WHEREAS, the applicant, Mike Deutsch, filed Planning Application No. PLSR20-0003 for Site Plan and Architectural Review for an exterior remodel and addition of an outdoor display area to an existing commercial building, in accordance with the City of Rohnert Park Municipal Code; WHEREAS, Planning Applications No. PLSR20-0003 was processed in the time and manner prescribed by State and local law; WHEREAS, on June 25, 2020, the Planning Commission reviewed Planning Application No. PLSR20-00035 at which time interested persons had an opportunity to testify either in support of or opposition to the project; and, WHEREAS, at the June 25, 2020, Planning Commission meeting, upon considering all testimony and arguments, if any, of all persons desiring to be heard, the Commission considered all the facts relating to Planning Application No. PLSR20-0003. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK DOES RESOLVE, DETERMINE AND ORDER AS FOLLOWS: Section 1. That the above recitations are true and correct. Section 2. Factors Considered. The Planning Commission, in approving Planning Application No. PLSR20-0003, makes the following factors, to wit: A.That the developments general appearance is compatible with existing development and enhances the surrounding neighborhood. Criteria Satisfied. The applicant has proposed architecture consistent with the City adopted Design Guidelines which identifies a modern architectural style as one that consists of a variety of materials and textures that would be used to achieve visual interest. Exterior wall cladding materials may include metal siding, fiber cement siding, stone or terra-cotta cladding, wood siding, stucco or concrete. The use of natural materials is also encouraged; materials should accentuate natural colors and textures. The proposed project architecture boasts two different façade treatments, new metal wall panels over the existing entry and new cedar siding and trim throughout. B.That the development incorporates a variation from adjacent on-site and off-site structures in height, bulk, and area; arrangement on the parcel; openings or breaks in the façade facing the street; and/or the line and pitch of the roof. Exhibit 1 to Resolution 2 Reso 2020-017 Criteria Satisfied. The project proposes to remodel the exterior façade with new signage and façade architectural elements as well as an addition of an outdoor display area. The new unenclosed shade structure for the outdoor display area as proposed is proportioned to the existing building and provides a consistent storefront bay repetition. The project as proposed provides continuity in design and materials on all elevations. C.That the development will be located and oriented in such a manner so as to provide pedestrian, bicycle and vehicular connections with adjacent properties, as appropriate, and avoids indiscriminate location and orientation. Criteria Satisfied. The project proposes to remodel the exterior façade with new signage and façade architectural elements. The exterior modifications to the existing commercial building would not alter the pedestrian, bicycle and vehicular connections with adjacent properties. Section 3. Environmental Clearance. The project has been analyzed for compliance with the requirements of the California Environmental Quality Act (CEQA) and found to be categorically exempt as a Class 1 Exemption under Section 15301: Existing Facility and Class 32 “Infill” Categorical Exemption (CEQA Guideline Section 15332). No further action is required pertaining to environmental review. NOW THEREFORE BE IT RESOLVED, that the Planning Commission does hereby approve Planning Application No. PLSR20-0003 subject to the Site Plan and Architectural Review submittal attached as Exhibit A and Conditions of Approval in the attached Exhibit B. BE IT FURTHER RESOLVED that said action shall not be deemed final until the appeal period has expired and that the appeal period shall be ten (10) working days from the date of said action. No building permits shall be issued until the appeal period has expired, providing there are no appeals. Exhibit A to Resolution EXISTING ONE STORY BUILDING NEW GREEN HOUSE AREA REDWOOD DR IVEDOWDEL AVENUEMILLBRAE AVENUE EXISTING OUTBACK STEAKHOUSE T NEW SECURED OUTDOOR DISPLAY AREA USE PERMIT PLAN604 Sutter Street, Ste 350 Folsom, CA 95630MIKE DEUTSCHMAY 1, 20204601 REDWOOD DRIVEAPN: 045-055-023EXISTING AND PROPOSED UTILITY PLANSHEET OF C1 C3Always Engineering, Inc.Civil Engineering & Topographic Surveying131 Stony Circle, Suite 1000Santa Rosa, CA 95401(707) 542-8795Fax (707) 542-8798www.alwayseng.com JasonH@alwayseng.comSHEET INDEX Prepared for:Prepared on:T REDWOOD DR IVEDOWDEL AVENUEMILLBRAE AVENUE EXISTING OUTBACK STEAKHOUSE EXISTING ONE STORY BUILDING USE PERMIT PLAN604 Sutter Street, Ste 350 Folsom, CA 95630MIKE DEUTSCHMAY 1, 20204601 REDWOOD DRIVEAPN: 045-055-023EXISTING HYDROLOGY PLANSHEET OF C2 C3Always Engineering, Inc.Civil Engineering & Topographic Surveying131 Stony Circle, Suite 1000Santa Rosa, CA 95401(707) 542-8795Fax (707) 542-8798www.alwayseng.com JasonH@alwayseng.comPrepared for:Prepared on: EXISTING ONE STORY BUILDING NEW GREEN HOUSE AREA REDWOOD DR IVEDOWDEL AVENUEMILLBRAE AVENUE EXISTING OUTBACK STEAKHOUSE T NEW SECURED OUTDOOR DISPLAY AREA USE PERMIT PLAN604 Sutter Street, Ste 350 Folsom, CA 95630MIKE DEUTSCHMAY 1, 20204601 REDWOOD DRIVEAPN: 045-055-023PROPOSED HYDROLOGY PLANSHEET OF C3 C3Always Engineering, Inc.Civil Engineering & Topographic Surveying131 Stony Circle, Suite 1000Santa Rosa, CA 95401(707) 542-8795Fax (707) 542-8798www.alwayseng.com JasonH@alwayseng.comPrepared for:Prepared on: Green Acres COAs 1 EXHIBIT B ADOPTED PER PLANNING COMMISSION RESOLUTION NO. 2020-017 CONDITIONS OF APPROVAL: SITE PLAN AND ARCHITECTURAL REVIEW GREEN ACRE NURSERY AND SUPPLY ADDITION AND REMODEL LOCATED AT 4601 REDWOOD DRIVE General Conditions 1.The facility shall comply with any and all applicable provisions of the Rohnert Park Municipal Code (RPMC) and any state or federal agency. The violation of any condition listed herein shall constitute a nuisance and a violation of the Rohnert Park Municipal Code. In conformity with Chapter 1.16 of the RPMC, a violation of the RPMC may be an infraction or a misdemeanor and shall be punishable as provided by law. In addition to criminal penalties, the City may seek injunctive relief. The Applicant agrees to pay for all attorney’s fees and costs, including, but not limited to, staff time incurred by the City in obtaining injunctive relief against the Applicant as a result of a failure of the Applicant to fully perform and adhere to all of the Conditions of Approval. 2. The Applicant agrees to defend, indemnify, hold harmless and release the City of Rohnert Park, its agents, officers, attorneys and employees from any claim, action or proceedings brought against any of the above, the purpose of which is to attack, set aside, void, or annul the approval of this application or certification of the environmental document which accompanies it. This indemnification obligation shall include but not be limited to, damages, costs, expenses, attorneys’, or expert witness fees that may be asserted by any person or entity, including the Applicant, whether or not there is concurrent passive or active negligence on the part of the City, its agents, officers, attorneys or employees. 3.The Site Plan and Architectural Review approval shall expire one year from the Planning Commission approval date, unless prior to the expiration a building permit is issued and construction is commenced and diligently pursued toward completion and the use is initiated, or an extension is requested and approved. Planning Conditions 4.A sign review permit will be required prior to the issuance of a building permit for the sign installation. 5. The use of the city parcel by the applicant shall not commence until all terms have been agreed upon and executed through a lease agreement approved in form and content by the City of Rohnert Park. 6. Staff will work with the applicant to ensure landscaping is constructed in accordance with the State’s Model Water Efficient Landscaping Ordinance (MWELO), or in accordance with water conservation standards which meet or exceed the requirements of the MWELO. The Applicant shall submit a landscaping and irrigation plan that identifies landscape material types and locations, irrigation, water usage calculations, and other information as Green Acres COAs 2 required. The plan shall be submitted to the Planning Division and reviewed and approved by the Development Services Department prior to construction. All costs for review of the requirements of the MWELO shall be borne by the Applicant. All landscaping and irrigation subject to the MWELO shall be substantially complete prior to final inspection. Public Safety Conditions 7. Fire sprinklers will be required per NFPA 13 and local ordinance. A fire hydrant flow test should be performed to establish the existing water availability. 8.A fire alarm system is required per NFPA 72 and local ordinance. Communications path for monitoring should be either IP or radio. 9.Separate Fire Department permits will be required for fire sprinklers, alarm and gate system. 10.Provide a key box for emergency responders’ use at the rear gate. A box may be purchased from the Fire Prevention Bureau by calling (707) 584-2641. 11.Address shall be illuminated and visible from the street per local ordinance. 12. Fire lanes shall be identified by red curbs per Information Bulletin 003-2019. 13. Due to the exposure from a running wildfire, non-combustible fencing is advised. 14. Additional conditions may be applied as the project develops. Engineering Conditions 15.On the Dowdell Avenue frontage, clarify how the loading dock driveway will be separated from the public at the southerly end of the outdoor display area to the north of the loading dock. 15.Clarify the proposed surface treatment for the truck turnaround area to the west of the existing loading dock (the existing surface appears to be dirt). 16.Provide a civil plan package for site improvements. This should include a grading/ drainage plan for the outdoor display area (area where existing pavement is being removed). 17.Provide a detailed map of the existing water system, including the onsite looped fire system. Provide detector checks/ backflow preventers to isolate the onsite system from the City system, OR provide an easement for the portions of the system to be publicly maintained. Green Acres COAs 3 18. Design the trash enclosure floor to drain to the sanitary sewer. If this is not practical, design the floor to drain to non-contact landscaping, OR provide a trash capture screen at the drain inlet immediately downstream of the enclosure.