Loading...
2022/09/13 City Council Resolution 2022-095 RESOLUTION NO. 2022-095 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ROHNERT PARK ADOPTING UPDATES TO THE MANUAL OF STANDARDS, DETAILS AND SPECIFICATIONS FOR WATER, SEWER,AND BICYCLE PARKING WHEREAS, the City Council of the City of Rohnert Park adopted the "Manual of Standards, Details and Specifications" (the "Standards") on January 10, 2006, by Resolution No. 2006-19; and WHEREAS,the City Council of the City of Rohnert Park adopted updates to the Standards in 2009, 2010, and 2014; and WHEREAS,materials and methods for construction continue to approve and updated to the building codes have also triggered changes in certain materials and installation methods; and WHEREAS, ongoing development requires that the Manual of Standards be kept up to date in order to ensure that the design and review process incorporates current best practice; and WHEREAS, staff is proposing to update the Standards and has reviewed the proposed modifications with stakeholders in the engineering design and development community; and WHEREAS, updating and improving the Standards will ensure that new construction is of the highest quality, thereby minimizing maintenance costs. NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Rohnert Park that it does hereby adopt the revised and additional sheets from the Manual of Standards, Details and Specifications in substantially similar form as attached hereto and incorporated herein as Exhibits A, B, C and D; 1. Title Page and Notice to Users (Exhibit Al) 2. Volume 1 Design Standards: a. Table of Contents (Exhibit A2) b. Section 8—Bicycle Parking Standards (Exhibit A3) 3. Volume 2 Detail Drawings a. Table of Contents (Exhibit B 1) 4. Volume 2 Chapter 1 Water Detail Drawings: a. Title Page and Drawing Table of Contents (Exhibit B2) b. Engineer's List of Approved Items (Exhibit B3) c. Updated STD 863A (Exhibit B4) d. Updated STD 863B (Exhibit B5) e. Updated STD 883 (Exhibit B6) 5. Volume 2 Chapter 2, Sewer Detail Drawings: a. Title Page and Drawing Table of Contents (Exhibit C I) JH-S:05-d b. Engineer's List of Approved Items (Exhibit C2) c. Updated STD 500 (Exhibit C3) d. New STD 511 (Exhibit C4) 6. Volume 2 Chapter 8, Bicycle Detail Drawings: a. Title Page and Table of Contents (Exhibit D 1) b. Engineer's List of Approved Items (Exhibit D2) c. New STD 301 (Exhibit D3) BE IT FURTHER RESOLVED that except as otherwise specified herein, the Manual of Standards, Details and Specifications shall remain unchanged and in full effect. BE IT FURTHER RESOLVED that adoption of these revised Standards is exempt from the application of the California Environmental Quality Act because it can been seen with certainty that there is no possibility that this action will have a significant effect on the environment(See CEQA Guidelines, Section 15061(b)(3)). DULY AND REGULARLY ADOPTED this 13th day of September 2022. CITY OF ROHNERT PARK l a kie Elwa , ayor ATTEST: Sylvia Lopez Cueva , y Clerk `� Attachments: Exhibits A, B, C and D -•—.--c/ GIUDICE:AL HOLLINGSWORTH-ADAMS STAFFORD: 1 RODRIGUEZ ►T ELWARD: ,� AYES: ( it ) NOES: ( 9) ABSENT: (I ABSTAIN: ( Resolution 2022-095 2 CITY OF ROHNERT PARK 2022 MANUAL OF STANDARDS, DETAILS AND SPECIFICATIONS (Volumes 1, 2 and 3) Manual of Standards, Details and Specifications Please read the following Notice to Users and refer to the City of Rohnert Park, City Council Resolutions listed below. NOTICE TO USERS of the City of Rohnert Park Manual of Standards, Details & Specifications This Notice to Users is made a part of the Manual of Standards, Details & Specifications (hereinafter referred to as Standards). Users of these Standards are cautioned that laws, codes, and regulations are ever-changing and it is the sole responsibility of the User preparing documents for permitting and/or construction to comply with current State and Federal Laws, Codes, and Regulations in the preparation of engineering documents. 1.0 Purpose The purpose of this Manual of Standards, Details & Specifications (Standards) is to provide minimum standards and requirements to be applied to improvements and private works to be dedicated to the public and accepted by the City for maintenance or operations, as well as improvements to be installed within existing right-of-way and easements. This is necessary in order to provide for the orderly and coordinated development of required facilities to be used by and for the public. These Standards shall apply to and regulate the design and preparation of plans for construction of streets, alleys, drainage, sewerage, street lighting, water supply facilities and other related public improvements. 1.1 Responsibilities The responsibilities of the City, Applicant, Applicant's Engineer and/or other User, and Contractor with respect to administrative implementation of an applicant-initiated or other project are defined in the following subsections. The City, the preparer of this document, and the City’s Agents shall be held harmless from any suit, litigation, or action arising out of compliance by the Applicant, Applicant's Engineer and/or other User, and Contractor with all applicable State and Federal Laws, Codes, and Regulations, or application of these standards, details and specifications. 1.2 City Responsibilities The City will be responsible for the review and approval of Improvement Plans and the inspection of all public improvements. 1.3 Applicant Responsibilities The Applicant, as applicable, shall have ultimate responsibility for compliance with requirements specified in these Standards. The Applicant shall be directly responsible for administrative requirements including application, submittal of the required Improvement Plans, bonds and insurance, agreements, and payment of fees. The Applicant shall also be responsible for performance of the Applicant's Engineer in meeting design standards and requirements and for the performance of the Contractor in meeting construction-related requirements. 1.4 Applicant Engineer's or other Users (User) Responsibilities These Standards presented herein provide requirements for the design and construction of public improvements and are intended to be the minimum standards. These Standards are not intended to be a substitute for engineering knowledge, judgment, or experience and shall be applied by the User as appropriate. Proposed deviations to these Standards shall be submitted, in writing, to the City Engineer. All engineering plans, specifications, reports, or other documents (engineering documents) shall be prepared by or under the direction of a State of California registered civil engineer and shall be signed and stamped with the registered engineers seal in accordance with State regulations. An approval signature by the City Engineer on the engineering documents does not in any way relieve the User of the responsibility to use professional engineering practices and to meet all requirements of the City. Proposed revisions to the approved engineering documents are subject to the City Engineers review and approval. It is the responsibility of the User to determine the applicability of each standard. These Standards constitute a minimum requirement for general conditions and may not apply to specific site conditions. 1.5 Contractor Responsibilities The Contractor shall be directly responsible for the means, methods, techniques, sequences, and procedures of construction not otherwise required by these Standards and the Improvement Plans. At all times, the Contractor shall be responsible for compliance with all governing federal, state, and local laws, ordinances, codes, orders, and regulations that in any manner affect those engaged or employed on the jobsite, the materials used in the Work, and the safe conduct of the Work. The Contractor shall also be directly responsible for the compliance of all finished work with these Standards and the Improvement Plans. 1.6 CEQA In conformance with the California Environmental Quality Act (CEQA), all actions by the City in reviewing, approving, issuing, and inspecting Improvement Plans, construction permits, and public improvements for applicant-initiated projects shall be deemed ministerial. It shall be the Applicant's responsibility to comply with the requirements of CEQA and the requirements of the lead agency, which has approved a development project or entitlement, including all mitigation measures that may relate to public improvements under City approval and inspection. The City, the preparer of this document and the City’s Agents shall be held harmless from any suit or action arising out of compliance or non-compliance by the Applicant with CEQA, or performance or lack of performance by the Applicant of any mitigation measure adopted or required by any local government. 1.7 Interpretation of Specifications and Details These Standards are intended to serve as one document. This means that the Specifications and Details contained herein are complementary, and what is called for in one shall be as binding as what is called for in both. In the event of discrepancies, errors, or omissions found in these Standards, or should it appear that there is not sufficient detail to perform the Work, then the User shall promptly submit in writing to the City Engineer a request for clarification or interpretation. 1.8 Deviations A request for a deviation from a City standard contained herein must be submitted in writing to the City Engineer by the User. Such requests shall identify the specific requirement at issue and state the proposed deviation with supporting technical information. Deviations shall be prepared by or under the direction of a State of California registered civil engineer and shall be signed and stamped with the registered engineers seal in accordance with State regulations. Approved by: Darrin Jenkins, P.E. Date: February 9, 2006 City Engineer Standards originally Compiled by: Winzler and Kelly Consulting Engineers William Silva, P.E. Date: 02/10/06 Marc Solomon, P.E. Date: 02/10/06 List of Revisions (Title) Date Approved: Resolution No. Revision Description 01/10/2006 2006-19 Adopted 2006 Manual of Standards 11/28/2006 2006-275 Adopted Bicycle Parking Standards 01/26/2010 2010-08 Revised Sewer Standards 03/22/2011 2011-27 Revised Streets & Roadways Standards Revised Water Standards 07/08/2014 2014-081 Revised Storm Drain Standards Revised Street and Roadway Standards Revised Traffic Standards Revised Street Lighting Standards 09/13/2022 2022-XX Revised Water Standards Revised Sewer Standards Revised Bicycle Parking Standards Design Standards Volume 1 for Public Improvements Revised September 2022 City of Rohnert Park Manual of Standards, Details and Specifications Volume 1 Design Standards 1. Water 2. Sewer 3. Storm Drain 4. Streets and Roadway 5. Traffic 6. Street Lighting 7. Parks and Landscaping 8. Bicycle Parking Volume 2 Detail Drawings Volume 3 Construction Specifications Design Standards Volume 1 for Public Improvements Revised September 2022 Design Standards Volume 1 for Public Improvements Revised September 2022 City of Rohnert Park Bicycle Parking Standards Design Standards BP-i Volume 1 for Public Improvements Revised September 2022 BICYCLE PARKING STANDARDS TABLE OF CONTENTS Volume 1 Design Standards Purpose ....................................................................................................................BP-1 Design Criteria .......................................................................................................BP-1 Layout of Bicycle Racks .........................................................................................BP-2 Design Standards BP-1 Volume 1 for Public Improvements Revised September 2022 BICYCLE PARKING DESIGN STANDARDS I. PURPOSE To provide for the installation of safe, convenient and secure bicycle parking facilities. II. DESIGN CRITERIA A. Unless otherwise approved by the City Engineer bicycle racks shall be inverted-U style bicycle racks with a height of 32 to 36 inches and wide of 18 to 24 inches. B. Racks shall be of one piece construction and include a single continuous bend with an internal radius of 10 inches. Racks shall be constructed of Scheduled 40, nominal size 1-1/2 inch steel pipe conforming to ASTM A53. C. Racks shall be fabricated with two 6-inch diameter anchor flanges flush mount welded to the base of each leg. Each anchor flange shall be 3/16” in thickness and shall have three mounting holes that are 7/16” in diameter and located 1” from the outer edge of the flange to allow the rack to affixed to a concrete surface with anchor bolts. D. Racks shall be hot-dipped galvanized after fabrication and handfiled to remove galvanizing flash. Rack coating shall be electrostatically applied polyester (TGIC) powder coat paint (6-8mils thickness) or PVC coating (15 mils thickness). E. Rails for multi-U racks shall be 4” wide and of sufficient length to allow for 30” spacing between inverted-Us. III. LAYOUT OF BICYCLE RACKS A. Side-by-side rack placement: Racks, which hold two bikes each, must be 30” apart from one another, and end racks must have 24” clearance to the sides from walls or other objects. In addition to space for bikes, the design shall include aisle that allows bikes to independently access the area. B. Angle layout (as in car parking stall): If a car parking stall is used for bike parking, it must be as close as possible to the store entrance. Bollards or other guarding shall be used to protect bikes from cars. C. End-to-end (as along a sidewalk or wall): If racks are placed end to-end along a wall, an access aisle is needed, and racks should be placed 7.5 feet (90 inches) apart. If along a sidewalk, allow at least 5 feet between racks; racks on the sidewalk should be set back an additional foot (3 feet total) from the curb, away from car doors. Design Standards Volume 2 for Public Improvements Revised September 2022 City of Rohnert Park Manual of Standards, Details and Specifications Volume 1 Design Standards Volume 2 Detail Drawings 1. Water 2. Sewer 3. Storm Drain 4. Streets and Roadway 5. Traffic 6. Street Lighting 7. Parks and Landscaping 8. Bicycle Parking Volume 3 Construction Specifications Detail Drawings Volume 2 for Public Improvements Revised September 2022 City of Rohnert Park Water Detail Drawings Detail Drawings W-1 Volume 2 for Public Improvements Revised September 2022 WATER DETAIL DRAWINGS Standard Number Title Date Approved 800 Series 850 Reserved 851 Typical Harness Installation for Flange Fittings 2011 852 Typical Harness Installation 2006 853 Concrete Anchor Blocks for Vertical Bends 2006 854 Concrete Thrust Blocking for Horizontal Bends 2011 855 Reserved 856 Typical Water Main Installation Over Structure 2011 857 Fire Hydrant Installation, 2 Sheets 2011 858 Reserved 859 Typical Temporary Blow-off and/Or Metered Connection Mains Under Construction 2006 860 Typical Temporary Metered Connection Fire Flow Required 2011 861 Blow-off With Harness 2011 862 Full-Size Blow-off 2011 863A Water Service with Fire System Supply 1-inch and 1-1/2-inch Disc Meters 2017 863B Water Service 5/8-inch x 3/4-inch and 1-inch x 1-1/2-inch Disc Meters 2017 864A Dual Water Service with Fire System Supply 1-inch and 1-1/2-inch Disc Meters 2017 864B Dual Water Service 5/8-inch x 3/4-inch and 1-inch Disc Meters 2017 865A Water Service 2-inch Disc Meter 2011 865B 2-inch Commercial Water Service 2011 866 3-inch Commercial Water Service 2011 867 4-inch Commercial Water Service 2011 868 6-inch Commercial Water Service 2011 869 Typical Water Connection Detail 2011 870 Reserved 871 Typical Locations of Water Mains and Mainline Valves 2006 872 Dirt Stop and Water Main Encasement 2011 873 Reserved 874 Double Check Valve Backflow Assembly 2006 875 Reserved 876 Reduced-Pressure Backflow Assembly 2011 877 Gate Valve 2011 878 Butterfly Valve and Tapping Valve 2011 879 Underground Fire Line Single Detector Check Installation, 3 Sheets 2011 880 Double Check-Detector Check Fire Line Backflow Assembly 2011 881 Pressure Reducing Valves 2011 882 Surge Anticipator Valve Or Pressure Relief Valve 2011 883 Air and Vacuum and Air Release Valve 2017 Detail Drawings W-1 Volume 2 for Public Improvements Revised September 2022 Standard Number Title Date Approved 884 Water Meter Installation for Private Nonresidential Systems 2006 885 Water Meter for Private Process and Evaporative Water Lines 2006 886 Water Sampling Station 2011 887 4-inch Ductile Iron Multi-Service Manifold 2011 888 Water Service Obstructions 2011 891A Drinking Fountain Cover Detail 2011 891B Drinking Fountain Cover Detail 2011 891C Drinking Fountain Cover Detail 2011 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-1 Volume 2 for Public Improvements Revised September 2022 Effective: ______________________ Standard 857 –Fire Hydrant and Lateral Hydrants Residential (All 2-2-1/2” and 1-4-1/2” outlet) Clow 960 Commercial (All 2-2-1/2” and 1-4-1/2” outlet) Clow 960 Hydrant Break-Off Check Valve Assembly Clow #40 Long Beach LB400 Hydrant Paint Coatings - Safety Blue and Aluminum Rust-Oleum Kelly Moore Paints Aluminum – 3415 Aluminum – 5880-530 Safety Blue – 5225 Safety Blue – 5780-564 Standard 858 – Typical Pumper Connection Details Low Profile Hydrant (1-2-1/2” and 1-4-1/2” outlet) Clow F-94 Hydrant Break-Off Check Valve Assembly (see St. 857) Clow #40 Long Beach LB400 Standard 861 – Blow-Off with Harness 2” Brass Ball Valve (FIP X FIP) Ford B11-777W Jones J-1900W McDonald 6101W Mueller B-20200 3” Brass Ball Valve Watts Series B-6000 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-2 Volume 2 for Public Improvements Revised September 2022 Boxes and Covers Size Location Box Number Cover Number 2” and 3” Traffic Christy B1324 Christy B1324-61JH 2” and 3” Non-traffic Christy B30 Quazite PG1324BA12 Christy FL30D Quazite PG1324WA50 Standard 862 – 8” Blow-Off Brass Ball Valve (FIP X FIP) Ford B11-777W Jones J-1900W McDonald 6101W Mueller B-20200 3” Brass Ball Valve Watts Series B-6000 Boxes and Covers Size Location Box Number Cover Number 8” Traffic Christy B2436 Quazite PG2436BA18 Christy B2436-62JH Quazite PG2436WAP250 8” Non-traffic Christy B40 Quazite PG2436BA18 Christy B40M Quazite PG2436WAP250 STANDARD 863A: Water Service W/ Fire System Supply 1” & 1-1/2” Disc Meters Angle Meter Ball Valve - Street Side (Comp. x MSN) or (Comp. x MSN) Ford 5/8” x 3/4” BA43-342W-Q 1” BA43-444W-Q 1-1/2” BFA43-666W-Q Jones 5/8” x 3/4” J-1963WSG – 1” x 3/4” 1” J-1963WSG – 1” 1-1/2” J-1975WSG – 1-1/2” McDonald 5/8” x 3/4” 4602BQ – 1” x 3/4” x 3/4” 1” 4602BQ – 1” 1-1/2” 4602BQ – 1-1/2” Mueller 5/8” x 3/4” B-24258 – 5/8” x 3/4” x 1” 1” B-24258 – 1” 1-1/2” B-24276 – 1-1/2” Angle Meter Ball Valve - Property Side (MSN x FIP) or (MF x FIP) Ford 1” BA11-444W with HB-34S * 1-1/2” BA11-666W with HB-67S* (No Ell Required) Jones 1” J-1970W – 1” * ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-3 Volume 2 for Public Improvements Revised September 2022 1-1/2” J-1900W – 1-1/2” * McDonald 1” 4604BF – 1” * 1-1/2” 6101W – 1-1/2” * Mueller 1” B-24287 with B-20298-99000 – 1” 1-1/2” B-24286 – 1-1/2” * with B-20298-99000 1-1/2" Valves require a brass street ell. * Requires a brass close nipple. Straight Meter Coupling - (MSN x MIP) Ford C38-44-1.5 Meter Flange - (MF x MIP) Ford CF 38-66-2 Jones J-129-M McDonald 610M Check Valve Watts CVY Red-White 236T Nibco T-413 Saddle - (AWWA CC Threaded Outlet) PVC C-900 Pipe Ford 202B Jones J-979 Mueller BR2B Series Ductile Iron Pipe Ford 202B Jones J-979 McDonald 3825 Mueller BR2B Series Corp Stop - (AWWA CC Thread x Comp.) Ford FB1000-4-Q FB1000-6-Q Jones J-3401SG – 1” J-1959SG – 1-1/2” McDonald 4701BQ Mueller B-25008 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-4 Volume 2 for Public Improvements Revised September 2022 Meter - (Read in gallons) 1” Badger Model 70 bronze disc meter w/bronze bottom, HRE 8 dial encoder, US Gal, torx, 5’ Itron ILC w/Itron ERT 100W+, 3 port with leak detector by Badger Meter. , 1-1/2” Badger Model 120 bronze disc meter w/test plug, 2 bolt elliptical flanges,HRE 8 dial encoder, US Gal, torx, 5’ Itron ILC w/Itron ERT 100W+, 3 port with leak detector by Badger Meter. ERT Bracket 1” Utilize register bracket or fiberglass rod 1-1/2” Utilize register bracket or fiberglass rod (Meter and Brackets can be obtained from Badger Meter or Pace Supply Corp) Meter Box and Cover 1” - Non-traffic Loading Box Cover Christy B30 FL30D BES C30 1” - Traffic Loading Box Cover Christy B1324 B1324-61GH BES C1324 C1324GH 1-1/2” - Non-traffic Loading Box Cover Christy B36 FL36D BES C36 1-1/2” - Traffic Loading Box Cover Christy B2436 B2436-61GH BES C2436 C2436GH STANDARD 863B: Water Service 5/8” x 3/4”, 1” & 1-1/2” Disc Meters Angle Meter Ball Valve - Street Side (Comp. x MSN) (For 1" and 1-1/2" meters see list for Standard 863A) Ford 5/8” x 3/4” BA43-342W-Q ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-5 Volume 2 for Public Improvements Revised September 2022 Jones 5/8” x 3/4” J-1963WSG – 1” x 3/4” McDonald 5/8” x 3/4” 4602BQ – 1” x 3/4” x 3/4” Mueller 5/8” x 3/4” B-24258 – 5/8” x 3/4” x 1” Angle Meter Ball Valve - Property Side (MSN x FIP) Ford 5/8” x 3/4” BA13-332W-HB-34S 1” BA13-444W-HB-34S 1-1/2” BFA13-666W-HB-67S Mueller 5/8” x 3/4” B-24265 with B-20298-99000 – 5/8” x 3/4” x 3/4” 1” B-24265 with B-20298-99000 – 1” 1-1/2” B-24286 – 1-1/2” Saddle See list for Standard 863A Corp Stop See list for Standard 863A Meter - (Read in gallons) 5/8” x 3/4” Badger Recordall Model 25 w/ RTR and 3-foot Register cable for use with a 5 foot in-line connector and Model 100WP+ with 3 ports and Leak Sensor + ITRON ERT w/6-inch Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com For 1" and 1-1/2" meters see Standard 863A ERT Bracket 5/8” x 3/4” Bracket to hang on cover support shoulder For 1" and 1-1/2" meters see Standard 863A Meter Box and Cover 5/8” x 3/4” - Non-traffic Loading Box Cover Christy B12 FL12D BES C12W 5/8” x 3/4” - Traffic Loading ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-6 Volume 2 for Public Improvements Revised September 2022 Box Cover Christy B1324 B1324-61GH BES C1324 C1324GH 1” and 1-1/2” - Non-traffic Loading Box Cover Christy B30 FL30D BES C30 1” and 1-1/2” - Traffic Loading Box Cover Christy B1324 B1324-61GH BES C1324 C1324GH STANDARD 864A: Dual Water Service w/ Fire Supply for 1” and 1-1/2” Disc Meters for Residential Meters Refer to STD 863A for specified parts STANDARD 864B: Dual Water Service for 5/8” x 3/4” & 1” Disc Meters (only with approval of City Engineer) For any part not listed here, see Standard 863A U-Branch Assembly Ford 5/8” x 3/4” U48-43-7.5Q 1” U48-64-9 Jones 5/8” x 3/4” J-2613SG 1” N/A McDonald 5/8” x 3/4” 08UQM – 1” x 3/4” x 7.5” 1” 08UTM – 1 1/2” x 1” x 9” Mueller 5/8” x 3/4” H-15363 - 1” x 3/4” x 7-1/2” 1” N/A Angle Meter Ball Valve – (FIP x MSN) Street side Ford 5/8” x 3/4” BA13-332W 1” BA13-444W Jones 5/8” x 3/4” J-1966W – 3/4” 1” J1966W – 1” McDonald 5/8” x 3/4” 4604B – 3/4” 1” 4604B – 1” Mueller 5/8” x 3/4” B-24265 – 5/8” x 3/4” x 3/4” 1” B-24265 – 1” ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-7 Volume 2 for Public Improvements Revised September 2022 Meter Box and Cover Non-traffic Loading Box Cover Christy B24 B24E BES C24 C24E Traffic Loading (Requires two separate boxes. Refer to Standard 863B for box and cover.) STANDARD 865A: Water Service - 2” Disc Meter Saddle See list for Standard 863A Corp Stop – (AWWA CC Thread x Comp.) Ford FB1000-7-Q Jones J-1959SG McDonald 4701BQ Mueller B-25008 2" Brass Adapter – (MIP x comp.) Ford C84-77-Q Jones J-2605-SG McDonald 4779Q Mueller H-15428 Brass Elbow – (Comp. x FIP) Ford L14-77-Q Jones J-2621-SG McDonald 4753Q Mueller H-15533 Ball Angle Meter Valve – (FIP x MF) Ford BA11-777W Jones J-1900W McDonald 4604B Mueller B-24286 Meter - (Read in gallons) ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-8 Volume 2 for Public Improvements Revised September 2022 2” Badger Recordall Model 170 ELL, TP w/ RTR and 3-foot Register cable for use with a 5 foot in-line connector and Model 100WP+ with 3 ports and Leak Sensor + ITRON ERT w/6-inch Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B36 FL36D BES C36 Traffic Loading Box Cover Christy B1730 B1730-61GH BES C1730 C1730GH STANDARD 865B: 2” Commercial Water Service Saddle See list for Standard 863A Gate Valve See City Standard 877 2" Brass Adapter – (MIP x comp.) See list for Standard 865A Brass Elbow – (Comp. x FIP) See list for Standard 865A Strainer 2" Badger, Bronze, Dual Elliptical Flange Plate Strainer Meter - (Read in gallons) ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-9 Volume 2 for Public Improvements Revised September 2022 2"EL Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B40 B40-61G B40M (Sidewalks) BES C40 C40-61G C40M (Sidewalks) Traffic Loading Box Cover Christy B2436 B2436-62JH BES C2436 C2436GH Ball Valve with Lockwing and Stops – (FIP) Ford B11-444W Jones J-1900W McDonald 6101W Mueller B-20200 Flexible Meter Coupling with SS Bolts and Nuts Smith Blair 926 Two Bolt Dresser with SS Bolts and Nuts Smith Blair 411 Romac 511 Power Seal 3501 STANDARD 866: 3” Commercial Water Service Tapping Sleeve with SS Flange ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-10 Volume 2 for Public Improvements Revised September 2022 Romac STS420 Ford FTSS Mueller H-304SS Smith Blair 665 Gate Valve See City Standard 877 Strainer 3" Badger, Bronze, Dual Round Flange Plate Strainer Meter - (Read in gallons) 3"Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B40 B40-61G B40M (Sidewalks) BES C40 C40-61G C40M (Sidewalks) Traffic Loading Box Cover Christy B2436 B2436-61JH BES C2436 C2436GH Ball Valve with Stops and 2" Operating Nut – (FIP) Ford B11-777W Jones J-1900W McDonald 6101W Mueller B-20200 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-11 Volume 2 for Public Improvements Revised September 2022 FCA with SS Nuts and Bolts Smith Blair 912 Romac 501 Two Bolt Dresser See list for Standard 865B STANDARD 867: 4” Commercial Water Service Tapping Sleeve with SS Flange See list for Standard 866 Gate Valve See City Standard 877 Strainer 4" Badger, Bronze, Dual Round Flange Plate Strainer Meter - (Read in gallons) 4"Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B48 B48-62G B48M2 (Sidewalks) BES C48 C48-62G C48M2 (Sidewalks) Traffic Loading Box Cover ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-12 Volume 2 for Public Improvements Revised September 2022 Christy B3048 B3048-63JH BES C1324 C1324GH FCA with SS Nuts and Bolts See list for Standard 866 STANDARD 868: 6” Commercial Water Service Tapping Sleeve with SS Flange See list for Standard 866 Gate Valve See City Standard 877 Strainer 6" Badger, Bronze, Dual Round Flange Plate Strainer Meter 6"Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box/ Cover/ Extensions Non-traffic Loading Box Cover Extensions Christy B52 B52-62G B52x10 B52M3 (Sidewalks) BES C52 C52-62G C52x10 C48M2 w/ C52L (Sidewalks) FCA with SS Nuts and Bolts See list for Standard 866 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-13 Volume 2 for Public Improvements Revised September 2022 Standard 872 – Dirt Stop and Water Main Encasement Casing Spacers Calpico Inc. The Model M Series Cascade Model CCS Standard 874 –Double Check Valve Backflow Device Refer to current Approved Backflow Prevention Assembly list from University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC Foundation). Standard 876 – Reduced Pressure Backflow Assembly Refer to current Approved Backflow Prevention Assembly list from University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC Foundation). Standard 877 – Gate Valve Valve Box Bes M2 Brooks 4TT Christy G5 D & L M-9009 South Bay B21 Gate Valves Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient seated gate valves. (For example: Clow, US Pipe, American Flow Control). Standard 878 – Butterfly Valve & Tapping Valve Tapping Sleeves (Stainless Steel) – 4” and larger Size on size up to an including 8” on 8” (examples: 4” on 4”, 6” on 6”) and any combinations (examples: 4” on 8”, 6” on 8”) DIP, CIP, PVC and existing ACP: (Sleeve must be compatible with pipe type) Dresser Style 630 Ford FTSS JMC 415 JCM 432 Mueller H-304 Powerseal 3490 Romac SST111 Smith-Blair 664-665 For taps smaller than 4”, see appropriate standard. ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-14 Volume 2 for Public Improvements Revised September 2022 Standard 879 – Single Check Detector in Vault Detector Check Valve Ames 1000DCV Hersey EDC III Hersey EDC IV Precast Vault Cover Utility Vault Co. 44-SRW (4’ x 4’) 4848SRW Utility Vault Co. 555-SRW (5’ x 5’) 4848SRW (Pedestrian walkways must have Algrip surface) Standard 880 – Double Check Detector Fire Line Backflow Assembly Refer to current Approved Backflow Prevention Assembly list from University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC Foundation). Standard 881 – Pressure Reducing Valves Pressure Reducing Valves CLA-VAL 90-01 Singer 206-PRC Watts PV-10-01 Precast Vault and Cover Refer to Approved List for Standard 879. Standard 882 – Surge Anticipator Valve or Pressure Relief Valve Tapping Sleeves Refer to Approved List for Standard 878. Utility Box and Cover (Non-Traffic Loading) Boxes and Covers Box Number Cover Number Christy B48 Christy B48M2 Quazite PG3048BA18 Quazite LG3048WAQ150 Standard 883 – Air & Vacuum & Air Release Valve Tapping Service Saddle Refer to Approved List for Standard 863. ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-15 Volume 2 for Public Improvements Revised September 2022 1” Ball Valve Curb Stop (FIP x FIP) Ford B11-444W Jones J-1900 McDonald 6101W Mueller B-20200 1” Corporation Stop (AWWA/CC Taper Thread Inlet x MIP or FIP) Ford FB 400-4 Ford FB1600-4 Jones J-45 Jones J-51 McDonald 3128B McDonald 3148B Mueller B-20045 Mueller B-2996 1” 90º Elbow (MIP x Compression) Ford L84-44-Q Jones J-2619SG McDonald 4779MQ Mueller H-15531 1” 90º Brass Elbow (FIP x Compression) Ford L14-44-Q Jones J-2621SG McDonald 4779Q Mueller H-15533 Combination Valves APCO 143C Crispin UL10 Valmatic VM-201C Closure Boxes and Covers Location Box Number Cover Number Traffic Christy B36 Christy B36-61D Non-Traffic Christy B36 Christy FL36D Standard 884 – Water Meter for Private Non-Residential Systems 5/8” Resetter Ford VV32-12W 1” Resetter ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-16 Volume 2 for Public Improvements Revised September 2022 Ford VV34-15W Meter Boxes and Covers Size Location Box Number Cover Number 5/8” x 3/4” Traffic Christy B12 Christy B12C Non-Traffic Christy B12 Christy B12C 1” Traffic Christy B1324 Christy B1324-61GH Non-Traffic Christy B30 Christy FL30D Standard 885 – Water Meter for Private Process and Evaporative Water Lines 5/8” x 3/4" Resetter Ford Resetter-52 McDonald 40-2 Mueller H-1412 1” Resetter Ford Resetter-52 McDonald 40-2 Mueller H-1412 Standard 886 – Water Sampling Station Aluminum Cast Cabinet Kupferle Model 88WC Eclipse Standard 887 – 4” Ductile Iron Multi-Service Manifold MIP x Compression Coupler 3/4”, 1”, and 2” Ford C84-33-Q Ford C84-44-Q Ford C84-77-Q Jones J-2605SG McDonald 4753A Mueller H-15428 Tapping Service Saddles for Individual Services Refer to approved list for appropriate service lateral standard. Tapping Sleeves Refer to approved list for Standard 878. ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-17 Volume 2 for Public Improvements Revised September 2022 APPROVED: Vanessa Garrett City Engineer BRASS STREET ELL CHECK VALVE -------\------+-.,---BRASS CLOSE NIPPLE NOTES .... '!I "A" .. • 4.. .... ""ERT -UNIT SHALL BE SUPPORTED IN AN APPROVED BRACKET IN THE METER BOX. TOP OF THE ERT SHALL BE WITHIN 3-1/4" OF THE TOP OF BOX.----�-STAMP 4" "W" ON FACE OF CURB CONNECT TRACER WIRE TO TRACER WIRE ON MAIN. IN THE ABSENSE OF A MAIN TRACER WIRE WRAP TRACER WIRE AROUND MAIN. 4 .. ;., POLYETHYLENE TUBING, TRACER WIRE: BLUE #12 SOLID COPPER CLASS 200, SDR 9 (CTS) (NO COUPLINGS) ,._ ___ CORPORATION STOP ....._ ___ WATER MAIN ...._ ___ SERVICE SADDLE z 0:: - w ::; > • 0 �u 1. THIS STANDARD APPLIES TO COMMERCIAL AND RESIDENTIAL SERVICES WHICH WHICH REQUIRE OR PROVIDE FIRE SPRINKLER SERVICE . 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF THE METER BOX WITH PERMANENT MARKER BEFORE CITY WILL ACTIVATE SERVICE. 3. NEW METER AND ERT SHALL BE FURNISHED AND INSTALLED BY PUBLIC WORKS DEPARTMENT.OLD METER SHALL BE REMOVED ONLY BY PUBLIC WORKS DEPARTMENT. 4. SERVICE LATERAL AND BUILDING SUPPLY LINES SHALL BE INSTALLED UNDER BOX, KNOCKOUTS SHALL NOT BE USED AND BE GROUTED. 5. WATER SERVICE TO BE LOCATED IN MIDDLE THIRD OF LOT AND OUTSIDE OF DRIVEWAY APPROACH UNLESS OTHERWISE NOTED ON PLANS. 6. SERVICE LATERAL BEDDING (PEA GRAVEL) SHALL BE PLACED PRIOR TO INSTALLATION OF POLYETHYLENE TUBING. 7. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEERS LIST OF APPROVED MATERIALS. 8. HYDRAULIC CALCULATIONS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13D. HYDRANT FLOW DATA SHALL BE BASED ON ACTUAL HYDRANT FLOW TEST DATA AS PROVIDED BY THE CITY FIRE DEPARTMENT. CALCULATIONS ARE SUBJECT TO FIRE SERVICES DIVISION APPROVAL. 9. SERVICE LATERALS OF 1-1/2" (MINIMUM) SIZE SHALL BE REQUIRED FOR DUAL METER INSTALLATIONS. 10. ALL COMPRESSION FITTINGS SHALL HAVE STAINLESS STEEL INSERTS. 11. NO FENCING SHALL BE INSTALL BETWEEN STREET AND METER BOX. FIRE SUPPLY (1" MIN.) DOMESTIC SUPPLY (3/4" MIN.) ANGLE BALL VALVE THREADED BRASS TEE ....._--CITY INSTALLED DISC METER CITY INSTALLED CABLE AND TAG. TAG SHALL READ "DO NOT SHUT OFF". II CONCRETE METER BOX WI COMPOSITE COVER 1 rDOMESTIC SUPPLY ,,, , ........ '-============ 1DOM'8TIC S"P,CY U"AND FIRE SUPPLY LINE SHALL MEET BUILDING DEPARTMENT AND FIRE DEPARTMENT REQUIREMENTS AS APPLICABLE, AND SHALL EXTEND MIN. OF 12" BEYOND BOX AND SIDEWALK . CITY MAINTAINED PRIVATE OWNER MAINTAINED 12. THE METER SHALL BE INSTALLED WITH PROPER LENGTHS OF PIPE BOTH UPSTREAM AND DOWN STREAM OF THE METER SEE MANUFACTURERS SPECIFICATIONS FOR DETERMINING PIPE LENGTH($). 13. A UTILITY BILLING ACCOUNT SHALL BE OPENED WITH CITY PRIOR TO FLOWING WATER THROUGH METER 14. PARKWAY STRIPS ARE PREFERABLE FOR METER BOX PLACEMENT, IF LOCATION NOT AVAILABLE, METER MUST BE WITHIN PUBLIC RIGHT-OF­WAY OR PUBLIC UTILITY EASEMENT AND OUT OF SIDEWALK RETROFIT NOTES 1. PROVIDE HYDRAULIC CALCULATIONS VERIFYING AVAILABLE PRESSURE AND FLOW PRIOR TO MODIFICATIONS FOR FIRE SERVICE RETROFITS. 2. A SEPARATE FIRE SERVICE SHALL BE INSTALLED (PER OTHER CITY STANDARDS) WHEN CALCULA T/ONS SHOW FIRE CITY OF ROHNERT PARK WATER SERVICE W/ FIRE SYSTEM SUPPLY-1" & 1-1/2" DISC METERS SCALE: NONE DATE: SEPTEMBER 2022 Approved: STD. -863A STAMP 4" 'W' ON FACE OF CURB -----CORPORATION STOP .... 'VAL... '----WATER MAIN ....._ ___ SERVICE SADDLE NOTES 1. THIS STANDARD APPLIES TO COMMERCIAL OR RESIDENTIAL SERVICES WHICH HAVE A SEPARATE FIRE SPRINKLER SYSTEM. 2. SET METER BOX COVER FLUSH WITH FINISHED SURFACE. THE ADDRESS MUST BE CLEARLY MARKED ON TOP OF METER BOX WITH PERMANENT MARKER BEFORE CITY WILL ACTIVATE SERVICE. 3. NEW METER AND ERT SHALL BE FURNISHED AND INSTALLED BY PUBLIC WORKS DEPARTMENT.OLD METER SHALL BE REMOVED ONLY BY PUBLIC WORKS DEPARTMENT. 4. SERVICE LATERAL AND BUILDING SUPPLY LINES SHALL BE INSTALLED UNDER BOX; KNOCKOUTS SHALL NOT BE USED. KNOCKOUTS SHALL BE GROUTED 5. WATER SERVICE TO BE LOCATED IN MIDDLE THIRD OF LOT AND OUTSIDE OF DRIVEWAY APPROACH UNLESS OTHERWISE NOTED ON PLANS. 6. SERVICE LATERAL BEDDING (PEA GRAVEL) SHALL BE PLACED PRIOR TO INSTALLATION OF POLYETHYLENE TUBING. 7. REFER TO CITY WATER STANDARDS FOR CONSTRUCTION STANDARDS, SPECIFICATIONS AND ENGINEER'S LIST OF APPROVED MATERIALS. 8. SERVICE LATERALS SHALL BE AT LEAST ONE SIZE LARGER THAN THE LARGEST METER BEING INSTALLED FOR DUAL SERVICE INSTALLATIONS. 9. ALL COMPRESSION FITTINGS SHALL HAVE STAINLESS STEEL INSERTS. 10. CONNECT SERVICE TRACER WIRE TO THE TRACER WIRE ON THE MAIN, IN ABSENCE OF TRACER WIRE ON THE MAIN WRAP TRACER WIRE AROUND MAIN. 12"-14" ERT -UNIT SHALL BE SUPPORTED IN AN APPROVED BRACKET HUNG IN THE METER BOX. TOP OF THE ERT SHALL BE WITHIN 3-1/4" OF THE TOP OF BOX. IN-LINE CONNECTOR WITH SECURITY SEAL CONCRETE METER BOX WITH COMPOSITE COVER 10" \ ��:���:2����;== BUILDING TO MEET BUILDING DEPARTMENT REQUIREMENTS ANGLE BALL METER VALVE 3/4" DRAIN ROCK (4" MIN.) PUBLIC PRIVATE (INCLUDING MAINTENANCE RESPONSIBILITY) 11. NO FENCING SHALL BE INSTALLED BETWEEN STREET AND METER BOX. 12. THE METER SHALL BE INSTALLED WITH PROPER LENGTHS OF PIPE BOTH UPSTREAM AND DOWN STREAM OF THE METER SEE MANUFACTURERS SPECIFICATIONS FOR DETERMINING PIPE LENGTH($). 13. A UTILITY BILLING ACCOUNT SHALL BE OPENED WITH CITY PRIOR TO FLOWING WATER THROUGH METER. CITY OF ROHNERT PARK WATER SERVICE 5/8" X 3/4", 1" & 1-1/2" DISC METERS SCALE: NONE DATE: SEPTEMBER 2022 Approved: STD. -8638 SEPTEMBER 2022 Detail Drawings Volume 2 for Public Improvements Revised September 2022 City of Rohnert Park Sewer Detail Drawings Detail Drawings S-1 Volume 2 for Public Improvements Revised September 2022 SEWER DETAIL DRAWINGS Standard Number Title Date Approved 500 Series 500 Standard Precast Concrete Manhole For Sanitary Sewer August 2022 501 Reserved July 2009 502 Shallow Manhole/Junction Structures for Multiple Laterals July 2009 503 Inside Drop in Sanitary Sewer Manhole July 2009 504 Reserved July 2009 505 Rodding Inlet July 2009 506 Temporary Mainline Cleanout July 2009 507 Abandoned Pipe Plug Detail July 2009 508 Abandoned Manhole Detail July 2009 509 Reserved July 2009 510 Reserved July 2009 511 Sanitary Sewer Manhole Frame and Cover August 2022 512 Standard Manhole Frame and Cover July 2009 512A Manhole Cover Placement July 2009 513 4” and 6” Sewer Service Lateral and Cleanout July 2009 514 Sewer Service Obstructions July 2009 515 Discharge For Private Force Main July 2009 516 (Sewer-Water Main) Crossing Details July 2009 517 Miscellaneous Pipe Installation Details July 2009 518 PVC Sewer Pipe Deflection Mandrel July 2009 520 (Three-Stage) Sand and Grease Interceptor July 2009 521 Sampling Manhole Exterior Use July 2009 522 Sampling Box Building Interior July 2009 523 (Three-Stage) Grease Interceptor July 2009 524 Control Sampling Manhole July 2009 525 Recreational Vehicle Disposal Facility July 2009 526 Food Facility Enclosure July 2009 530 General Sewer System Testing July 2009 530A General Sewer System Testing July 2009 530B Sewer Manhole Testing July 2009 531 Low-Pressure Air Test Table July 2009 532 PVC Sanitary Sewer July 2009 533 Pipe/Structure Penetration Detail July 2009 534 4” Combination Air Valve for Sewer Force Mains July 2009 ENGINEER’S LIST OF APPROVED ITEMS for use with Sewer Design Standards Approved:____________________ Detail Drawings S-2 Volume 2 for Public Improvements Revised September 2022 Effective: ______________________ Standard 500 - Standard Precast Concrete Manhole for Sanitary Sewer Precast Base &Barrels Connectors Cook Concrete Products, Inc. Cast in PVC Coupler Central Precast Concrete, Inc. “A LOK” or “A LOK X-CEL” KriStar Enterprises, Inc. “A LOK” flexible, Rubber “boot”, or PVC coupler Note: City will require shop drawings submitted for approval. Manhole Interior Patch Material All Crete 20 All Patch 5 All Patch 20 Rapid Set Mortar Mix Rapid Set Cement All SikaSet Mortar Speed Crete Red Speed Crete Blue Xypex Patch and Plug Cast in Place Base Water Stops Press-Seal Gasket Corp. WS Series Water Stop HDPE Grade Rings Ladtech Construction Foam Seal Guard XSeal Corrosion Tape Scotchrap 6” All-weather Tape (or approved equivilant) Standard 505 - Rodding Inlet Rim and Cover D&L Supply HG 531 South Bay Foundry SBF 1249 Standard 506 - Temporary Mainline Cleanout ENGINEER’S LIST OF APPROVED ITEMS for use with Sewer Design Standards Approved:____________________ Detail Drawings S-3 Volume 2 for Public Improvements Revised September 2022 Rim and Cover Famcon Pipe & Supply, Inc Pamrex 24 Standard 511 – Sanitary Sewer Manhole Frame and Cover* Manhole Frame and Cover EJ series 26” Assembly 2600 Series 32” Assembly 3200 Series *For sanitary sewer & storm sewer manholes only; must be equipped with twistlift lock option Standard 512 – Manhole Frame and Cover** Manhole Frame and Cover Famcon Pipe & Supply, Inc Pamrex 24 **For grease interceptors only Standard 513 – 4” & 6” Sewer Service Lateral & Cleanout Cleanout Box 4” D & L Supply M-8030 Geneco CC4 w/Lid marked sewer South Bay Foundry B5230 Cleanout Box 6” Geneco CC6 w/Lid marked sewer Flush Mount “T” Cone Plug ETCO CO-402 Flush Plug (MPT) 4” & 6” Multi Fittings 040492 (283440) – 4” 040958 (283060) – 6” Female Adapter (HxFPT) 4” & 6” Multi Fittings 040949 (282541) – 4” 040952 (282560) – 6” Saddle or Taps Geneco Sealtite Tap-tite Romac Style “CB” Sewer Saddle Couplings ENGINEER’S LIST OF APPROVED ITEMS for use with Sewer Design Standards Approved:____________________ Detail Drawings S-4 Volume 2 for Public Improvements Revised September 2022 Joints, Inc. Calder Couplings Fernco 1051-44, 1056-44, 1002-44 Indiana Seal 156-44 Mission Band-Seal Couplings Mission Flex-Seal Couplings Standard 516, 517 - Sewer-Water Main Crossing Details - Miscellaneous Pipe Installation Details Couplings APAC 300 Series Dresser Style 253 Fernco 1000 Series Joints, Inc. Calder Couplings Maxifit MaxiDaptor Mission Band-Seal Couplings Mission Flex-Seal Couplings Powerseal 3500 Series Romac 501 Series Smith-Blair 441 Series Tyler Pipe 5-144L U.S. Pipe U-584 Standard 520 - Three Stage Sand and Grease Interceptor Pre-manufactured Tanks Central Precast Company (SRCAST) McNothingham Selvage Concrete Products Standard 521 - Sampling Manhole Exterior Use Precast Base Aluminum Floor Hatch FHA-H20 Load Angle Frame Johnson Products Nystrom Standard 522 - Sampling Box Building Interior Precast Box Aluminum Floor Hatch ENGINEER’S LIST OF APPROVED ITEMS for use with Sewer Design Standards Approved:____________________ Detail Drawings S-5 Volume 2 for Public Improvements Revised September 2022 FHA-H20 Load Angle Frame Johnson Products Nystrom Standard 523 - Three Stage Grease Interceptor Tanks Central Precast Company (SRCAST) Johnson Products McNothingham Selvage Concrete Products Standard 524 - Control Sampling Manhole Precast Box Aluminum Floor Hatch Standard 525 - Recreational Vehicle Disposal Facility Cleanout Box & Cover See City Standard 513 Standard 533 – Pipe Penetration Detail Modular Seals Pipeline Seal & Insulation, Inc. Link-Seal Modular Seals Standard 534 – 4" Combination Air Valve for Sewer Force Mains Vento-O-Mat Series RGX APPROVED: __________________________ Vanessa Garrett City Engineer Manhole frame and cover labeled "SEWER" (See std. 511 & 512) � I tZZZTcr77z221 I Level with 1 :3 UNIMPROVED SURFACE I IMPROVED SURFACE HDPE slope ring __ _ 1• min. (See 6" Min. if poured in place 3" I 24• !Min. 48"!11 or 60"!11 I.D. Larger ell barrels may be req'd. under special circumstances. ' . Trowel smooth Slope 2"/ft. See note 7} Finished grade Tape & foam (See note 11) HDPE grade rings, typ. (See note 12) Note 3) ---+--+--�, ·. J+;:.--;:; ._, ._:,;;'�:I !�..,�t-----,i--------,t--✓ NOTES: 1 . When manholes are installed in unimproved areas, the top of the cover shall be a min. of 1 foot above grade. 2. 3. 4. 5. 6. 7. Min. of one 3• grade adjustment ring. Max. height of !l[ade adjustment rings = 20 • Set all barrel sections & taper sections in plastic gasket, Ram-nek or approved alternate. Typical joint use (1)3/4"x 2-1/2" Ram-nek seal,(2 seals in high water table areas}. Cone section (taper} must be concentric for 48"!11 manhole or eccentric for 60"!11 manhole unless otherwise specified and approved by City Engineer. After lower ring section is set, break out top half of pipe flush with inside face of M.H. wall and construct shelf and u-shaped channel. Make elevation changes gradually and directionalchanges with smooth curves. Slopeand size of channels shall match upstream and downstream pipes. Manhole channelswith a horizontal change in direction of 30' or more shall have a minimumdrop of 0.1' across the manhole orshall match the slope of the pipe, whichever is greater. Poured-in-place base shall be poured full thickness as shown on the detail on undisturbed soil. Precast base to be from City En.,9ineer's approved list and placed on 6 minimum of 3/4" drain rock installed against undisturbed earth and shall extend a minimum 6" beyond edge of base. Class "A" cone. collar shall be brought up to grade. Allow 7 days for concrete to cure prior to traffic loading. Use lamp black Class "A" cone. base (see note 6). -I For manholes over 1 O' deep include I �1r min. 8 3 max. (Sae note 1 O) to match surrounding asphalt. Standard manhole barrel section per ASTM C478. #4 bars O 1' O.C. each way. Install elastomeric waterstop with 316 stainless steel clamp for poured in place bases, in accordance with manufacturer's instructions as shown. (typical) (See note 10) Eccentric manhole taper, cover & grade rings to be located over downstream pipe. r-------------------------7 I I I �---I I I I I I I I I I _________ J L __ (See note 10) --7 I r------- 9. 10. 11. 12. 13. 48"!11 I.D. M.H. to be used for sewer mains less than 18"!11. 60"!11 I.D. M.H. to be used for all trunk and collector sewers 18"!11 to 48"!11 or where drop fittings are used. Romac couplings with a shear band are to be used for new connection that require an existing manhole retrofit or new manhole addition only. Install construction foam between hdpe ring and concrete and between HDPE ring and frame; wrap all HDPE rings with 60 mil 6" corrosion prevention tape. Trim bottom of first HDPE grade ring to sit flush on top of concrete barrel. To make cone flush and avoid point loading, mortar can be used (As needed). Install external joint seal at all barrel sections. Install 60 mil 5• corrosion prevention tape. I I I 1(See I 1 I I I I I I CITY OF ROHNERT PARK I L __________ _ ___________ _J MANHOLE BASE CHANNELIZATION PLAN AND LOCATION OF ECCENTRIC MANHOLE COVER STANDARD PRECAST CONCRETE MANHOLE for SANITARY SEWER SCALE: NONE DATE: SEPTEMBER 2022 Approved: STD. -500 3.79" 0.67" Lock Option TwislLIFT ® Exhibit A Locking Mechanism 0.67" (2) Quarter Turn locks w/ security bolt (Exhibit A); 1 to be a surcharge paddle 1.75" 18.27"_) B.C. ,__ __ 26.06" DIA. -----< 2" Dia. Sprue Hole Witness Mark 1.25" Stainless Steel Pick Bar (2) Quarter Turn locks w/ security bolt (Exhibit A); 1 to be a surcharge paddle 32 00" � 360" ¢ 1.75" -I 1 50" . .,r::==========*�· I) 24 42" 0.67" .J I f------BC. -I ,d==-32 --07''---=�,w 1.30" 4.25" 24"DIA. CLEAR OPENING NOTES: 1----25.50" DIA. --""°">------37" DIA. ---------< Section A-A: 26" I 30.00" I CLEAR OPENING Section A-A: 32" 1.Provide with 2-quarter turn paddle locking mechanisms, one to be surcharge type paddle. Locate surcharge paddle lock at downstream side of manhole. Use Twistlift Lock option. 2.Covers shall be one-man operable using standard tools. 3.Specify utility for labeling of cover when ordering. APPROVED MANHOLE FRAME & COVER See Engineer's Approved List CITY OF ROHNERT PARK SCALE: Approved: SANITARY SEWER MANHOLE COVER NONE DATE: SEPTEMBER 2023 STD. -511 Design Standards Volume 2 for Public Improvements Revised 2022 City of Rohnert Park Bicycle Parking Standards Design Standards BP-1 Volume 1 for Public Improvements Revised September 2022 BICYCLE PARKING DETAIL DRAWINGS Standard Number Title Date Approved 300 Series 300 Bicycle Parking Notes September 2022 301 Layout and Space Requirements for Bicycle Parking September 2022 Guidelines for Bicycle Parking 1.BIKE RACK SUPPORTS FRAME A bike rack should support the bicycle frame in two places, since most bikes aren't freestanding. lnverted-U racks work well (see box). Avoid outdated bike racks that only support the bicycle at the wheel, as these can damage wheels, and are not suitable for secure locking. The popular ribbon or wave-type rack, when used as designed, only supports a bicycle in one place, leaving bikes susceptible to falling down or being knocked over. 2.SPACES OF ADEQUATE WIDTH Most manufacturers still sell outdated bike racks that do not accommodate the very common mountain-style handlebars (typical width 24"). They often overstate the capacity their bike racks provide. Plan for at least 2 feet wide by 6 feet long per bike parking space, reflecting bikes' actual size. Multiple side-to-side bike racks should be spaced at least 30 inches apart. End-to-end racks, as along a sidewalk, should be at least 5 feet apart. Sec page 5 for layout requirements. 3.ACCOMMODATES VARIOUS LOCKS A bike rack should be able to accommodate U-locks, cable locks, and chains, and allow both the bicycle frame and wheels to be secured to the bike rack. The geometry of the bike rack should make it easy to lock to. Also, pipe used to make bike racks shouldn't be too thick (outer diameter of 2 inches max), so a lock can easily get around both the rack and the bike. U-lock and cable lock. 4.SIMPLE AND DURABLE A bike rack should have no moving parts. It should be designed to be simple to use with any style or size of bike. It should also be sturdy and able to be solidly affixed to the pavement. The surface coating should be maintenance-free, as well as corrosion-and impact-resistant, and non-damaging to bikes' finish. See page 5 for complete bike rack specifications. SPECS FOR INVERTED-U RACK Height: 36" (range 32-36"); Width: 24" (range 18-24") Shape: Single continuous bend (internal radius 1 O"); one piece construction with straight parallel legs. Pipe size: 1.9" outer diam., 1.5" inner diam. (ASTM A53 Sched. 40 nominal size 1 -1/2" steel pipe, 0.145" wall thickness); total length of about 86". Anchor Flanges: Two 6" diam. circles (3/16" thickness) with three holes (7/16" diam., 1" from outer edge, set at 120-degree angles), flush-mount welded to base of each leg. Bolts: Secure anchor bolts for affixing to concrete. Surface: Hot-dipped galvanized after fabrication; hand filed to remove galvanizing flash. Coating: Electrostatically applied polyester (TGIC) powder coat paint (6-8 mils), or PVC coating (15 mils). Rails for multi-U-racks: 4" wide, sufficient length to allow 30" between inverted U's CITY OF ROHNERT PARK BICYCLE PARKING NOTES SCALE: NONE I DATE:SEPTEMBER 2022 Approved: STD. -300 30" "" -----------� L ________________________ "--------------------------------------- Angle layout (as in car parking stall): If a car parking stall is to be used for bike parking, it must be as close as possible to the store entrance. Bollards or other guarding is needed to 36,, __________ 1 ____ � ______ 1 pro tect bik es fro m cars. j 1 I I I I I I I I I I I !30" L-----�----------------------,----------r----======================-===========, 1---- I I I I I I I I 24 11 24 11 ---- : 3011 1----------1----------' : 3011 1----------1----------' : 3011 I I 3011 End-to-end (as along a sidewalk or wall): If racks are placed end-to-end along a wall, an access aisle is needed, and racks should be placed 7.5 feet (90 inches) apart. If along a sidewalk, allow at least 5 feet between racks; racks on the sidewalk should be set back an additional foot (3 feet total) from the curb, away from car doors. 3011 3011 ,---------- --------------------------------------, 6011 Side-by-side rack placement: Racks, which hold two bikes each, must be 30" apart from one another, and end racks must have 24" clearance to the sides from walls or : l other objects. In addition to space _for: bikes, an aisle is needed so that bikes I : can independently access the area. : This layout is 9 x 12 feet. I ----------------------L __________ ------ ------- CITY OF ROHNERT PARK LAYOUT AND SPACE REQUIREMENTS FOR BICYCLE PARKING SCALE: NONE Approved: DATE: SEPTEMBER 2022 STD. -301