Loading...
2023/01/26 Planning Commission Agenda Packet City of Rohnert Park Planning Commission NOTICE IS HEREBY GIVEN THAT A MEETING will be held on Thursday, January 26, 2023 6:00 P.M. CITY HALL - COUNCIL CHAMBER 130 Avram Avenue, Rohnert Park, California To any member of the audience desiring to address the Planning Commission: For public comment on items listed or not listed on the agenda, or on agenda items if unable to speak at the scheduled time, you may do so upon recognition from the Chairperson. Please fill out a speaker card prior to speaking. 1. CALL TO ORDER 2. PLEDGE OF ALLEGIANCE 3. ROLL CALL (Austin-Dillon_____ Epstein____ Lam____ Orloff____ Striplen____) 4. PUBLIC COMMENT – Persons who wish to speak to the Commission regarding an item that is not on the agenda may do so at this time. Please see above for details on how to submit public comments. 5. CONSENT CALENDAR - ADOPTION OF MINUTES 5.1 Approval of the Draft Minutes of the Planning Commission Meeting of January 12, 2023 Commissioner Motion/Roll Call Vote: (Austin-Dillon_____ Epstein ____ Lam ____ Orloff _____ Striplen _____) 6. AGENDA ITEMS 6.1 PUBLIC HEARING – CONDITIONAL USE PERMIT/SITE PLAN AND ARCHITECTURAL REVIEW– File No. PLUP21-0006/PLSR21-0006 – Nancy Carreras/Interplan, LLC – Consideration of Resolution No. 2023-03 approving an amendment to a Conditional Use Permit and Site Plan and Architectural Review for modifications to the exiting drive thru operation and addition of other site improvements for the Chick-Fil-A restaurant located at 5080 Redwood Drive (APN 045-083-002) CEQA: This project is exempt under CEQA Section 15301: Existing Facility. No further action is required pertaining to environmental review. Commissioner Motion/Roll Call Vote: (Austin-Dillon_____ Epstein ____ Lam ____ Orloff _____ Striplen _____) 7. YEAR IN REVIEW PRESENTATION 8. ITEMS FROM THE PLANNING COMMISSION 9. ITEMS FROM THE DEVELOPMENT SERVICES STAFF 10. ADJOURNMENT NOTE: If you challenge the nature of the proposed action in court, you may be limited to raising only those issues you or someone else raised at public hearing(s) described in this agenda, or in written correspondence delivered to the City of Rohnert Park at, or prior to the public hearing(s). AMERICAN DISABILITY ACT ACCOMMODATIONS: Any member of the public who needs accommodations should email the ADA Coordinator at jcannon@rpcity.org or by calling 707-588-2221. The ADA Coordinator will use their best efforts to provide reasonable accommodations to provide as much accessibility as possible while also maintaining public safety in accordance with the City procedure for resolving reasonable accommodation requests. Information about reasonable accommodations is available on the City website at https://www.rpcity.org/city_hall/departments/human_resources/a_d_a_and_accessibility_resources CERTIFICATION OF POSTING OF AGENDA I, Clotile Blanks, Community Development Technician, for the City of Rohnert Park, declare that the foregoing notice and agenda for the January 26, 2023 Planning Commission Meeting of the City of Rohnert Park was posted and available for review on January 20, 2023 at Rohnert Park City Hall, 130 Avram Avenue, Rohnert Park, California 94928. The agenda is available on the City of Rohnert Park’s website at www.rpcity.org. Signed this 20th day of January, 2023 at Rohnert Park, California. Clotile Blanks Appeals of any decisions made tonight must be received by the Planning Division within 10 days and no later than 5:00 p.m. on February 6, 2023. Minutes of the Planning Commission Meeting of the City of Rohnert Park Thursday, January 12, 2023 6:00 P.M. 130 Avram Avenue, Rohnert Park 1. CALL TO ORDER Chairperson Lam called the regular meeting to order at 6:00 p.m. 2. PLEDGE OF ALLEGIANCE Led by Chairperson Lam. 3. ROLL CALL Present: Fanny Lam, Chairperson Marc Orloff, Commissioner Tramaine Austin-Dillion,Commissioner Absent: Charles Striplen, Vice Chairperson 4. CEREMONY FOR INSTALLATION OF PLANNING COMMISSIONERS AND SELECTION OF OFFICERS FOR THE YEAR 2022 City Clerk, Sylvia Lopez, joined the meeting to install newly appointed Commissioner, Matthew Epstein and re-appointed Commissioner Marc Orloff. ACTION: Moved/seconded Lam/Orloff) to nominate Commissioner Austin-Dillion as Chairperson. Motion carried by the following unanimous (4-0-1) roll call vote: AYES: Lam, Orloff, Epstein, Austin- Dillion and; NOES: None; ABSTAIN: None; ABSENT: Striplen ACTION: Moved/seconded Lam/Orloff) to nominate Commissioner Matthew Epstein as Vice Chairperson, Motion carried by the following unanimous (4-0-1) roll call vote: AYES: Lam, Orloff, Epstein, Austin- Dillion and; NOES: None; ABSTAIN: None; ABSENT: Striplen 5. PUBLIC COMMENT None. 6. CONSENT CALENDAR - ADOPTION OF MINUTES 6.1 Approval of the Draft Minutes of the Planning Commission Meeting of December 8, 2022. ACTION: Moved/Seconded (Orloff/Lam) to adopt the Minutes of the Planning Commission Meeting of December 8, 2022. Motion carried by the following (3-0-1-1) roll call vote: AYES: Lam, Orloff, Austin-Dillion, and; NOES: None; ABSENT: Striplen; ABSTAIN: Epstein. 7. AGENDA ITEMS 7.1 PUBLIC HEARING – NEGATIVE DECLARATION AND AMENDMENTS TO ROHNERT PARK GENERAL PLAN, HOUSING ELEMENT UPDATE 2023 TO 2031 Consideration and recommendation to the City Council on the adoption of a Negative Declaration (Resolution 2023-01) and amendments to the General Plan (Resolution 2023-02) to adopt Housing Element Update 2023-2031 of the General Plan. The Housing Element Update sets forth the City’s eight-year strategy to preserve and enhance the community’s character, expand housing opportunities for all economic segments of the population, and provide guidance and direction for local government decision-making on all matters related to housing. Jenna Garcia, Housing Manager provided a PowerPoint, supported by 4Leaf contractors Elliott Picket and Jane Riley. Ms. Garcia, highlighted the project in the following areas: background, dtrategy, housing sites, public outreach, housing element goals, overview of programs, balance of housing types, provision of affordable housing, preservation and improvement of the City’s existing housing, and Regional Housing Needs Allocation (RHNA) targets along with recommendation and next steps. The Commission participated in a discussion and offered the following comments: • Rezoning, to meet RHNA and the potential to cause problems with the nearby schools. • Administrative List of Additional Sites, i.e. Roberts Lake, Gold Ridge, School District property, areas near the fire station and Rohnert Park Expressway. • Commissioner Epstein, Questioned the No Net Loss Law, and if the RHNA Targets were by unit or square footage. He also wanted to know the JADU’s and ADU’s fire code requirements. Mary Grace Pawson, Director of Development Services added details about the State of California’s ADU and JADU building and fire code standards. • Chairperson Austin-Dillion thanked Ms. Garcia for reviewing and including public comments from the community on the Housing Element. • Public Comment on the Housing Element was given by Calum Weeks, Policy Director for Generation Housing and Jake Mackenzie former elected official and long-time resident. ACTION: Moved/Seconded (Orloff/Austin-Dillion) to adopt Resolution No. 2023-01 of the Planning Commission of the City of Rohnert Park recommending the City Council adopt a Negative Declaration and make certain findings as required by the California Environmental Quality Act (“CEQA”) in connection with the approval of General Plan Amendment adopting an update of the Housing Element for the period of 2023-203. Motion carried by the following (4-0-1) roll call vote: AYES: Orloff, Lam, Austin-Dillion, Epstein and; NOES: None; ABSENT: Striplen; ABSTAIN: None. ACTION: Moved/Second (Orloff/Lam) to adopt Resolution No. 2023-02 of the Planning Commission of the City of Rohnert Park recommending the City Council adopt a General Plan Amendment to update the Housing Element of the General Plan for the period of 2023-2031 and affirmatively further fair housing, and comply with state Housing Element Law. Motion carried by the following (4-0-1) roll call vote: AYES: Orloff, Lam, Austin-Dillion, Epstein and; NOES: None; ABSENT: Striplen; ABSTAIN: None. 8. ITEMS FROM THE PLANNING COMMISSION No comments from the Planning Commissioners. 9. ITEMS FROM THE DEVELOPMENT SERVICE STAFF Planning Manager, Jeff Beiswenger, welcomed the new Planning Commissioner, Matthew Epstein and the renewal of Planning Commissioner Marc Orloff’s term. Also noted, was the upcoming introduction of a Conditional Use Permit and SPAR from Chick Fil A at the next meeting scheduled for January 26, 2023. 10. ADJOURNMENT Chairperson Austin-Dillion adjourned the regular meeting at 7:45 p.m. ________________________________ ___________________________________ Chairperson Recording Secretary – Clotile Blanks Page 1 City of Rohnert Park Planning Commission Report Meeting Date: January 12, 2023 Item No: 6.1 Prepared by: Suzie Azevedo, Assistant Planner Agenda Title: PROJ21-0004, Conditional Use Permit/Site Plan and Architectural Review – Chick Fil-A Drive Thru Modification Location: 5080 Redwood Drive GP/Zoning: Commercial/C-R: Regional Commercial Applicant/Owner: Nancy Carreras/Interplan, LLC for Michael Mallery/RP Taft 711 LLC RECOMMENDED ACTION: Staff recommends that the Planning Commission adopt Resolution No. 2023-03, approving Conditional Use Permit/Site Plan and Architectural Review for drive-through modifications to the existing Chick-Fil-A restaurant to include a dual lane drive-through operation, site improvements to the parking and landscape areas and addition of “Face to Face” and “Order Meal Delivery” canopies (Figure 1: Location Map). This proposal is consistent with the Regional Commercial land use designation in the General Plan and the associated C-R: Regional Commercial zoning district. Surrounding uses include Krispy Kreme to the south, Oil Stop to the north, and Highway 101 to the east. Figure 1: Location Map BACKGROUND: The project is located on a 1.5-acre parcel (originally built as Fresh Choice restaurant) in the northern portion of the City in an area predominately characterized by existing Page 2 developed parcels with commercial retail and restaurant-style businesses. It is located adjacent to Golf Course Drive interchange with the 101 freeway and is the middle of three parcels developed together, with a car wash/auto service station to the northwest and the current Krispy Kreme (previously El Torito) restaurant to the south. In 2015, a Conditional Use Permit/Site Plan and Architectural Review were approved to convert the existing Fresh Choice restaurant to a Chick- Fil-A restaurant with a single drive-thru. The applicant, Nancy Carreras/Interplan on behalf of RP Taft 711 LLC, proposes to expand the drive-through operation from one lane to two lanes. The proposal also includes the replacement of landscape planter islands, and the addition of a Face to Face (F2F) canopy and Order Meal Delivery (OMD) canopy. The project will also reconfigure parking spaces immediately sur- rounding Chick-Fil-A. This includes implementing angled parking and repositioning parking spaces, which would result in a decrease of 7 parking spaces. Project Details Traffic Circulation and Parking: There are two entrance driveways serving the subject prop- erty and the two adjacent sites, Oil Stop Carwash at the corner of Redwood Drive and Golf Course Drive and Krispy Kreme to the immediate south. The access and parking areas are shared by all three businesses and there are reciprocal easements for joint use of the facilities. The appli- cant has submitted a parking and traffic circulation analysis to address current conditions associ- ated with the drive-through operation and the effects the proposed improvements will have on the subject site and surrounding area with respect to parking and on-site circulation. The analysis submitted is included in Attachment 2 to this report. Two separate striped northbound lanes will be provided upon entry from Redwood Drive to al- low for access to both Krispy Kreme and Chick-Fil-A. Each lane will be marked with directional arrows and striping to direct traffic to the appropriate drive-through. For vehicles that intend on entering the Chick-Fil-A drive-through but are instead in the Krispy Kreme drive-through lane, “One Way’ roadway markings will be provided to lead vehicles around the northside of the Chick-Fil-A to enter the drive-through from the west. “Keep Clear” markings at the exit of the Krispy Kreme drive-through will be updated upon reconfiguration of the drive aisle, which will prevent potential spillback from the Chick-Fil-A drive-through from blocking the Krispy Kreme drive-through exit. The reconfiguration of the drive aisle will also slightly shift two landscape planter areas. (Figure 2: Traffic Circulation) Page 3 Figure 2: Traffic Cirulation The proposed site reconfiguration will construct the double-lane drive-through with two order boards and a single pick-up window, with associates walking orders to vehicles in the outer lane. Associates will be able to access the outer lane via a striped crosswalk on the west side of Chick-Fil-A. The existing drive- through currently allows approximately eleven vehicles, and with the addition of the second drive-through lane, a capacity of approximately 30 vehicles (600 feet) would be accommodated before a queue begins to form outside of the drive-through lanes. Given this configuration, queueing at the Chick-Fil-A should no longer affect circulation for the neighboring Krispy Kreme and Oilstop operations. (Figure 3: Drive- Through Queue Data) Page 4 Figure 3: Drive-Through Queue Data Traffic Management Plan: The applicant has submitted the following Traffic Management Plan. The plan identifies the layout of peak and non-peak service at the drive-through operation location: Peak Time. Peak times are between 12:00 p.m. and 2:00 p.m. or when there are 24 vehicles in the drive- through line and/or drive-through stacking capacity blocks the drive-through bypass lane. During peak time operations ten to eleven team members will be outside to manage the flow of traffic in the drive- through by doing the following: • One traffic controller at the drive-through entrance will direct the drive-through line and encourage cars to move forward as the line moves forward. • Four to five team members to take orders and accept credit card or app payments; • One cash person; • Two food runners outside; and • Two food runners outside to deliver curbside pick-up orders to the designated parking spaces. During the peak time, the pass-by lane will be used as an additional food pick-up lane where cars will not merge but rather move forward and an employee will bring their food. This will allow these cars to exit the property. Non-peak Time. Non-Peak times are when there are 24 cars or less in our drive-through lane. During Non-peak operations there will be a total of seven team members outside to manage the flow of traffic in the drive-through lanes as outlined below: • Three to four team members to take orders and accept credit card and app payments; • One cash person; and • Two food runners. For curbside pick-up, we have one food runner outside to deliver orders to the designated parking spaces. Page 5 Site parking inventory and occupancy surveys were also conducted at the existing parking lot shared by Chick-Fil-A, Krispy Kreme, and Oilstop. The surveys identified an inventory of 154 total parking spaces, including 6 handicap (ADA) spaces. Based on the observed peak parking demand at the Chick-Fil-A parcel, 85 vehicles on the weekday and 98 vehicles on the weekend, the existing parking supply of 154 spaces for the parcel has been found to be adequate to accommodate the existing Chick-Fil-A, Krispy Kreme and Oilstop operations. A more detailed analysis is included in the attached “Chick-Fil-A Rohnert Park Drive-Through Queue, Parking, and Circulation Analysis”, Attachment 2. As mentioned previously, there are reciprocal access and parking agreements already in place. A condition of approval has been added that prior to approval/issuance of any building permit, the updated Joint Use and Maintenance Agreement, outlining the terms and conditions of the access and parking details, be fully executed by all parties and a recorded copy submitted to the Development Services Department, Planning Division. Canopy Addition: The proposal also includes the removal of the existing drive-through canopy and installation of a new Order Meal Delivery (OMD) canopy at the pick up location and a Face to Face (F2F) canopy addition at the order point area of the drive through operation. (Figure 4: Canopy Location) The covered canopy will provide sun and weather protection for customers and crew members providing assistance. During normal operations, customers will merge to a single lane as they proceed through the queue, picking up their order at the drive-through window also protected by sun and weather with a canopy. During periods of higher operation tempo, customers will remain in the two-lane configuration as additional crew members are deployed to deliver food to customers in the outside lane (otherwise used as a by-pass lane as needed to more efficiently move customers through the drive-through canopy. Figure 4: Canopy Location ANALYSIS: The proposed project includes exterior modifications to include reconfiguration of the drive-through operation, new canopy(s) and minor landscape alterations to an existing commercial restaurant site with no changes to setbacks, height or lot coverage. Additionally, the floor area will remain the same with seating on the inside and outside of the restaurant. The project would remain in compliance with the Commercial-R (Regional) General Plan land use designation of the property, which is intended to provide sites for retail areas containing a wide variety of businesses, including: retail stores, eating and drinking establishments, commercial recreation, business and personal services that serve the community and outlying areas within an eight to twenty-mile radius. Section of 17.07, Land Use Footnotes/Special Provisions of the Rohnert Park Municipal Code provides standards for the approval, conditional approval or disapproval of particular uses that typically have Page 6 unusual site development features or operating characteristics requiring the establishment of standards to ensure that the use is designed, located, and operated compatibly with uses on adjoining properties and in the surrounding area. These standards are used to assist the review of these projects, creating quality developments that reflect the character and goals of the city while facilitating a streamlined project approval. Land Use Footnotes/Special Provisions, Subsection I. Drive-Through Window, provides for the following criteria:  Drive-through windows shall have a capacity for queuing a minimum of six vehicles behind the menu board. Queuing area shall not interfere with on or off-site circulation patterns and shall be reviewed and approved prior to approval of a conditional use permit.  A parking and vehicular circulation plan shall be submitted for review and approval prior to approval of a conditional use permit.  Pedestrian walkways should not intersect the drive-through drive aisles, but where they do, they shall have clear visibility, and they must be emphasized by enriched paving or striping. The Chick-Fil-A drive through modifications satisfies this criteria as outlined in this report. The review of the project is also guided by RPMC Section 17.25.014, Findings. The applicant has put forward a design which will “clean up” the existing operation and provide for a more seamless circulation pattern for the surrounding area. Staff has evaluated each of the criteria required in RPMC 17.25.014 and has prepared the appropriate findings recommending approval with conditions in the resolution attached. ENVIRONMENTAL DETERMINATION: The project has been analyzed for compliance with the requirements of the California Environmental Quality Act (CEQA) and found to be categorically exempt as a Class 1 Exemption under Section 15301: Existing Facility. No further action is required pertaining to environmental review. PUBLIC NOTIFICATION: A public hearing notice was published in the Community Voice on January 13, 2023. Notice was sent to property owners within 300 feet, as required by the zoning ordinance. The January 26, 2023 Planning Commission Meeting Agenda was posted as required and the meeting materials have been posted to the web site and have been made available to the public. Planning Manager Approval Date: 1/20/23 Attachments: 1. Planning Commission Resolution 2023-03 A. Exhibit A - Applicant’s Design package 2. Chick-Fil-A Rohnert Park Drive-Through Queue, Parking, and Circulation Analysis 1 Reso 2023-03 PLANNING COMMISSION RESOLUTION NO. 2023-03 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK APPROVING SITE PLAN AND ARCHITECTURAL REVIEW AND CONDITIONAL USE PERMIT FOR THE EXTERIOR MODIFICATIONS TO THE DRIVE-THROUGH OPERATION OF AN EXISTING RESTAURANT BUILDING LOCATED AT 5080 REDWOOD DRIVE (CHICK-FIL-A) (APN 045-083-002) WHEREAS, the applicant, Nancy Carreras, filed Planning Application Nos. PROJ21-0004 for Site Plan and Architectural Review and Conditional Use Permit for exterior modifications to the drive-through operation and the addition of a canopy for an existing restaurant (Chick-Fil-A) located at 5080 Redwood Drive, in accordance with the City of Rohnert Park Municipal Code; WHEREAS, Planning Application No. PROJ21-0004 was processed in the time and manner prescribed by State and local law; WHEREAS, on January 26, 2023, the Planning Commission reviewed Planning Application No. PROJ21-0004 at which time interested persons had an opportunity to testify either in support of or opposition to the project; and WHEREAS, at the January 26, 2023 Planning Commission meeting, upon considering all testimony and arguments, if any, of all persons desiring to be heard, the Commission considered all the facts relating to Planning Application Nos. PROJ21-0004. NOW, THEREFORE, THE PLANNING COMMISSION OF THE CITY OF ROHNERT PARK DOES RESOLVE, DETERMINE AND ORDER AS FOLLOWS: Section 1. That the above recitations are true and correct. Section 2. Factors Considered for Site Plan and Architectural Review. The Planning Commission, in approving Planning Application No. PROJ21-0004 makes the following findings pursuant to Rohnert Park Municipal Code 17.25.033: A. That the developments general appearance is compatible with existing development and enhances the surrounding neighborhood Criteria Satisfied. The modifications to the Chick-Fil-A Restaurant are proposed for a location that provides convenient access from Highway 101 for tourists and other visitors. The applicant has proposed improvements that will provide a higher quality, safer and more effective circulation transition for not only the Chick-Fil-A parcel, but the surrounding businesses, Oilstop Carwash and Krispy Kreme. The upgrade to the restaurant building site will be an attractive addition to the west side of town and the overall site design components give the restaurant site a look and feel that will enhance the surrounding neighborhood. 2 Reso 2023-03 B. That the development incorporates a variation from adjacent on-site and off- site structures in height, bulk, and area; arrangement on the parcel; openings or breaks in the facade facing the street; and/or the line and pitch of the roof Criteria Satisfied. The proposed project includes exterior modifications to include reconfiguration of the drive-through operation, new canopy(s) and minor landscape alterations to an existing commercial restaurant site with no changes to the existing façade, setbacks, height or lot coverage. The addition of a covered canopy will provide sun and weather protection for customers and crew members providing assistance. The existing building incorporates a variation from adjacent on-site and off-site structures in height, bulk, area, and arrangement on the parcel as well as openings and breaks in the facade facing the street and the line and pitch of the roof. C. That the development will be located and oriented in such a manner so as to provide pedestrian, bicycle and vehicular connections with adjacent properties, as appropriate, and avoids indiscriminate location and orientation. Criteria Satisfied. The project proposes to remodel the exterior with circulation enhancements and elements that will provide a cleaner and safer transition throughout the site for pedestrians, bicycle and vehicular connections with adjacent properties. There are no changes to the building orientation, setbacks, or lot coverage on the site. The existing pedestrian access path from the front entrance of Chick-Fil-A to the public sidewalk along Redwood Drive will remain, in compliance with the American with Disabilities Act (ADA). Section 3. Factors Considered for Conditional Use Permit. The Planning Commission approving Planning Application No. PROJ21-0004, makes the following findings pursuant to Rohnert Park Municipal Code 17.16.040 and 17.27.100: A. That the proposed location of the conditional use/sign is in accord with the objectives of the City of Rohnert Park Zoning Ordinance and the purposes of the district in which the site and sign is located. Criteria Satisfied. The project is located within the C-R, Regional Commercial District, which is intended to allow for the operation of activities that provide goods and services that serve the community and outlying areas within an eight to twenty- mile radius. The restaurant provides a visitor-serving function, consistent with the definition of the regional commercial zoning district. The restaurant site and neighboring businesses have functioned okay in the past and the proposed improvements will enhance site circulation and traffic with the addition of pavement delineations and direction. Given the site's close proximity to Interstate 101, the upgraded modifications will aid in the attraction of tourists and other visitors who are important to the economy of the City. B. That the proposed location of the conditional use/sign and the conditions under which it is operated or maintained will not be detrimental to the public health, 3 Reso 2023-03 safety, or welfare, or materially injurious to properties or improvements in the vicinity. Criteria Satisfied. The surrounding properties are all of commercial uses. The proposed dual lane operation and on-site modifications are sited and designed in a manner that achieves a safe built environment. The proposal has been carefully reviewed and conditions will be imposed by the Conditional Use Permit and Site Plan and Architectural Review that should mitigate any concerns related to the facility with regard to building, fire and life safety as well as any nuisance conditions that may arise given the specifics of this type of use. C. That the proposed conditional use/sign will comply with each of the applicable provisions of Title 17 of the City of Rohnert Park Municipal Code. Criteria Satisfied. T he project site is currently consistent with the intent of the zoning district and all the various development standards including height, setbacks, lot coverage and parking. Staff has reviewed the proposal in conjunction with standards set forth in Chapter 17.07. Land Use Footnotes/Special Provisions. A violation of a condition of approval or a provision of Title 17, Zoning, may cause a conditional use permit to be revoked or modified as set forth in Chapter 17.25 of the Rohnert Park Municipal Code. The applicant has duly been notified of this provision. Section 4. Environmental Clearance. The project has been analyzed for compliance with the requirements of the California Environmental Quality Act (CEQA) and found to be categorically exempt as a Class 1 Exemption under Section 15301: Existing Facility. No further action is required pertaining to environmental review. NOW THEREFORE BE IT RESOLVED, that the Planning Commission does hereby approve Planning Application No. PROJ21-0004, subject to the Applicant Design Package, attached as Exhibit A, and the following conditions: 1. The Site Plan and Architectural Review and the Conditional Use Permit approval shall expire one year from the Planning Commission approval date, unless prior to the expiration a building permit is applied for the exterior remodel and any tenant improvements, or an extension is requested and approved. 2. All applicable provisions of the City of Rohnert Park Municipal Code (RPMC), are made a part of these conditions of approval in their entirety, as if fully contained herein. 3. Project shall comply with: 2019 California Building Code, 2019 California Plumbing Code, 2019 California Mechanical Code, 2019 California Electrical Code, City of Rohnert Park Municipal Code Title 15. 4. The Applicant agrees to defend, indemnify, hold harmless and release the City of Rohnert Park, its agents, officers, attorneys and employees from any claim, action or proceedings brought against any of the above, the purpose of which is to attack, set aside, void, or annul the approval of this application or certification of the environmental document which accompanies it. This indemnification obligation shall include but not be limited to, damages, costs, expenses, 4 Reso 2023-03 attorneys', or expert witness fees that may be asserted by any person or entity, including the Applicant, whether or not there is concurrent passive or active negligence on the part of the City, its agents, officers, attorneys or employees. 5. Prior to approval of the building permit, the applicant shall submit a fully executed and recorded copy of the Joint Use and Maintenance Agreement by and between the ownership of the Oilstop Carwash, Chick-Fil-A and Krispy Kreme. 6. The development of the project shall conform in its entirety to plans and specifications submitted herein as Exhibit A. 7. The construction drawings shall include the following: (A) Please add the following to the General Notes: "The Contractor is responsible for the removal of all USA markings created within the project limits, and in relation to the project. Replacement and restoration must meet the approval of the City Engineer." (B) Please add the following to the General Notes: "The contractor shall maintain one clean set of marked plans showing all changes and “as built” information. This set of plans will be submitted to the City engineer upon completion of work.” (C) Please add the following to the General Notes: “All utility covers shall meet final paving elevations. More than 0.25 inch of deviation between the top of the utility cover and the surrounding paving at any location shall be cause for rejection." 8. If the canopy is of combustible construction, a fire sprinkler may be required. BE IT FURTHER RESOLVED that said action shall not be deemed final until the appeal period has expired and that the appeal period shall be ten (10) working days from the date of said action. No building permits shall be issued until the appeal period has expired, providing there are no appeals. DULY AND REGULARLY ADOPTED on this 26th day of January, 2023 by the City of Rohnert Park Planning Commission by the following vote: AYES: _____ NOES:_____ ABSENT:_____ ABSTAIN:_____ AUSTIN-DILLON_____ EPSTEIN _____ LAM ____ORLOFF _____ STRIPLEN ____ ____________________________________________________________ Tramaine Austin-Dillon, Chairperson, Rohnert Park Planning Commission _________________________________ Clotile Blanks, Recording Secretary Attachments: Exhibit A: Applicant Design Package 5 Reso 2023-03 LEGEND A8 = AGCIIEG.IU: BAS£ AC = ASPHALT COHCRfT£ Cf = CURB FACE a. = CENTERI.JNE CO = a..EANOUT FD = FOUND Ff = AMSH[D FlOOR FG = Fl� Gl!ADE FH = flR£ H'tDRAHT Fl = Fl.OW Uh{ FS = Fl�SHED SURFACE GM • GAS METER GI! = TOP OF Gl!AU: CV = GAS VALVE HT = HEJGHT I!' = fi(lj PF£ LS = LIGHT STANDARD L.&T = LEAD & TAG MH = MANHIX.E NG = NATURAL GROUND N&:T .. NAL &: TAG PB = PIJll BDX PCC • COOl(I[ Pl = PROPIRTY UM': SMH = SE\IIR MANIIIX.E SPK = SPlkE SW • SDEWALK TC = TOP llf CURB W = WASHER 1111 = WATER MffiR WV = WATI:R VALVE N, C NORTH S. = SOUTH E = EAST W. = WEST N\.Y • NOOTHEHLY �LY• SOOTHmLY E'LY = EASTERLY WLY = VESTERL Y N /0 = NORTH DF 5/0 = SOOTH llf E/D C EAST OF W/D = iEST OF f = PROPERTY UN[ <I. = CENTERLINE R/W = R�HT OF WAY 6 = 0£1.TA R = RAD�S L = LE/lGTH T = TA/aNT (RAD)= RlaAL !£ARING ('21.ll0)1C=E»s11NGEl£VATI!II -CATV-=CABl£1VLOE --!--•flKlUIR -----•Cl.Ill( . -GB-Gl-= llWIE IIDI( LINE -R-R-=ROO:Ul --S--=S!IIRUl --SD--•Sll;llljil': u,t --T --= 1El£PH!IIE LINE � A flRE HYDRANT 0--0 STREET UG!IT 0'l TRAFflC SGNAL r-llW!XSlCHJLAq,;&m.E ¢ LIGHT STAtflARO ---o=-UTILITY Pill E--GUY VIIRE & ANOIOR ... WAlER METER D "" GAS MffiR D "' WATER VALVE .. A GAS VM.\.£ PS PUll BOX D 8 Gl!ATE INLIT SIGN II VENT ® SE\IIR MANHO!f @ STORM ORAW MANrlOL[ 0 U:LEPHONE MANHO!f @) MANHOLE i SEWER a..EANOUT I!;) HANDCAP PARl<�G STAil. (D LANDSCAPID IJ[). al PLDTABLE EASEMENT ITEM No PER Till£ REPORT / --W--111 lJJII� -(427.0)-EJOST. CONTOUR �i · r7",. ram (sur • �';-..>"'7 SPEOES VARES) � '----' SINGLE STORY STUCC0/81.J(. BUlG. CHIC!<-FL-A RESTAURANT BLDG. M!EA • 5,444 S.F. EXTcRIO R BLDG. DW.ENSJONS MEASURED AT GROUN D LEVEL SHOWN AND USED FOR AREA. ., .. & lU..DNG DErAL SCALE, 1"=20' Jl.7' UTILITY NOTE; OH-SIT£ UTIUTlES ARC SHOWN OH TIIIS SURVEY P£R DESIGN Pl.ANS, ABOVE GROUND EVIDENCE 4110 CONTRACTOR MARK-UPS. RECORD DRAWINGS orOH-SITE UHOC!!GROUNO UTIUTIES WERE NOT AVAILABLE Al THE TIME or'THIS SURVEY. THE ACTUAL l.OC4T10N OF UHOERCROUND UTIUTIES MAY VMft fROll THOSE SHOWN HEREON AHO ADOffiOHAl. LINES MAYBE POSSIBLE. ( . l-1,/2' PIJ// BRASS DISC N oru; (RI) 1--T"" ___ C:..:U:..:R:..:VE ;,. D:..:A:..:TA"---�--� 1-:,,,�,...-+--=0,,.,1"'�"'-.,"'·,-+-..,., ,.,;;.,00�1-..,.,o;:L os=-• � NO. CU R VE D ATA D R 0178 44 4J9.00 10.0S 111 CJ C2 0611 '50 161, 24-2 fD. 2• 1p• PUN BRASS DISC IN IIE!t (RI) 0672 15 261.00 /!I.IIAJ;NA1 #l 1/(:£1l®'(RI (llnDFORR a.,s·n.rmr ,o. "'cN.U.,,. ·11a21"6U'{II 21i21i I.Ill( l"/PW� Nl1%J� '12B' ctr"" �.,.."b :7 �. ' r \ GRAPHIC SCALE i i ( IN FEET ) 1 inch - 20 fl FD. �I/?' l'UN BRASS DISC IN ill1l. {RI) ro. 2" PUN DISC '1/CC ILLEGIBLE i ti"" ........., !'\c\J1.Jv 1/ij� L� 5200 Buffington Rd. Atlonto Georgia, 30349-2998 Revisions: Mork Dote By .& 8£13.::'.15 sos UTILITY UPDAlES AND REVISIONS PER ATTORNEY COMMENTS. Mork Dote By .& 2£23.::'.17 KOL AS-81JlLT SURVEY Mork Date By L Seal _.,. .IJSBfl C. 1RI/XA w .. ASStJJAJa II£ C,W/ CnglnHrs and £end Surw10rs l'S S. ANTA 11111: !illTf It/ t!Wl.tCAIIIU pi�-(11 "5-DIDl(rAJ/} STORE 101 @ GOLF COURSE DRIVE 5080 REDWOOD DRIVE ROHNERT PARK, CALIFORNIA SHEET TITI.£ (AS-BUil T SURVEY) VERSION: ISSUE OAlE: Job No. : Cl'A1S019 Store ·@3688 Dote :04/30/15 Drown By =� Checked By:� gi .. t C-100.2 '-.. � EXHIBIT A x x x x p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360 T1.1.dwg Sheet No: 00-3688-T1.1 - TITLE SHEET Saved by: jonfie - Tuesday, July 12, 2022 3:29 PM Printed by: Jonathan Fiesta - July 12, 2022 3:29 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 01/31/2023 jonfie - 07/12/2022 3:34:21 PM 9'-6"VERIFY W/ CIVIL PLANS2'-0"STRIPING8'-0"18'-0"18'-0"7'-5 1/2" 51'-5 1/2"10'-0" HOLD13'-4"2'-0"HOLD25'-4"2'-0"1'-6"RE: CNPY SHPDWGS7'-5 1/2"18'-0"18'-0"8'-0" 51'-5 1/2"7'-5" MIN. B/O FAN2'-0"13'-4"10'-0" 9'-0" 25'-4"8"8'-0" MIN. B/O HEATER12"MIN.30°0' °p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360 ASP 1.0 - 1.1.dwg Sheet No: 10-3688-ASP1.0-ARCH SITE PLAN-F2F Saved by: jonfie - Monday, June 20, 2022 2:07 PM Printed by: Jonathan Fiesta - July 12, 2022 3:30 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 01/31/2023 jonfie - 07/12/2022 3:34:22 PM 70'-1 1/2" 2'-7 1/2"24'-0"3'-5 1/2"3'-5 1/2"24'-0"29'-5 1/2"29'-5 1/2"17'-0"17'-0"17'-0"12'-6"4'-0"2"2"2'-0"2'-0"STRIPING11'-0"VERIFY W/ CIVIL PLANS9'-0"VERIFY W/ CIVIL PLANS2'-0"STRIPING22'-0"2'-0"2"1'-6"RE: CIVIL & CNPY SHPDWGS7'-5" MIN. B/O FAN9'-0" 2" 4'-0" 70'-1 1/2" 2'-7 1/2"17'-0"17'-0"17'-0"12'-6"8"8'-0" MIN. B/O HEATERp:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360 ASP 1.0 - 1.1.dwg Sheet No: 10-3688-ASP1.1-ARCH SITE PLAN-OMD Saved by: jonfie - Monday, June 20, 2022 2:07 PM Printed by: Jonathan Fiesta - July 12, 2022 3:30 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 01/31/2023 jonfie - 07/12/2022 3:34:22 PM UNDERGROUND ABOVE GROUND LEGEND 2 ORDER CANOPY POWER PLAN SCALE: 1/4" = 1'-0" 3 MEAL DELIVERY CANOPY POWER PLAN SCALE: 1/4" = 1'-0" FIELD VERIFY ALL CONDITIONS NOTE! AS NOTED IN THE SPECIFICATIONS, ALL WIRING LAYOUTS, LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS SHALL BE DETERMINED BY THE CONSTRUCTION AND STRUCTURE OF THE BUILDING AND SHALL BE VERIFIED AND COORDINATED IN THE FIELD. EACH TRADE CONTRACTOR SHALL VERIFY WITH THE GENERAL CONTRACTOR THAT HE HAS THOROUGHLY REVIEWED AND COORDINATED ALL LOCATIONS AND ROUTINGS WITH ALL OTHER TRADES PRIOR TO FABRICATION OF CONDUITS, DUCTS, OR PIPING, AND START OF INSTALLATION OF SAME (INCLUDING SPRINKLER PIPING WHEN PRESENT ON JOB). ANY INSTALLATION OR CONSTRUCTION CONFLICTS WHICH OCCUR IN THE FIELD SHALL BE RESOLVED BY THE TRADE CONTRACTOR TO THE SATISFACTION OF THE OWNER AND ARCHITECT AND AT NO EXPENSE TO THE OWNER, ARCHITECT AND/OR GENERAL CONTRACTOR. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ALTERNATE FOR EXISTING CONDITIONS: IF THE IN-GROUND PULLBOX IS NOT EXISTING OR IS NOT ACCESSIBLE OR USABLE, THEN THE CONTRACTOR MAY PROVIDE THREE 1" UNDERGROUND CONDUIT WITH CONDUCTORS FROM THE EXISTING BUILDING TO THE DESIGNATED CANOPY COLUMN. EACH CONDUIT SHALL TERMINATE AT THE COLUMNS HANDHOLE LOCATION INSIDE THE COLUMN WITH A COUPLING TO TRANSITION FROM THE PVC CONDUIT TO FLEXIBLE "LIQUID-TITE" CONDUIT AND EXTEND TO THE BACKBOXES FOR THE SWITCHES AND OUTLET. 1 EXISTING IN-GROUND QUAZITE PULLBOX FOR MLOP DATA CABLES WITH POWER NEMA 3R JUNCTION BOX MOUNTED INSIDE THE PULLBOX. EXISTING 2" UNDERGROUND SCH40 PVC CONDUIT FOR AUDIO SYSTEM/DETECTOR LOOP CABLES. EXISTING 1" EMPTY UNDERGROUND SCH40 PVC CONDUIT FOR AUDIO SYSTEM/DETECTOR LOOP CABLES. CEILING LIGHT PROVIDED BY CANOPY SUPPLIER AND INSTALLED BY E.C. INFRARED GAS HEATER WITH INTEGRAL ON-OFF SWITCH PROVIDED BY OTHERS. EXISTING MENUBOARD WITH CANOPY. EXISTING 2" UNDERGROUND SCH40 PVC CONDUIT WITH POWER CONDUCTORS, SEE WIRING SCHEMATIC. INSTALL UNDERGROUND 3" SCH40 PVC CONDUIT UP INTO THE CANOPY COLUMN WITH TYPE MC CABLE (GALVANIZED STEEL WITH PVC JACKET) RUN WITHIN FOR THE 120V POWER FOR LIGHTS, 120 VOLT POWER FOR FANS, AND 24 VOLT POWER FOR THE INFRARED GAS HEATERS. EXISTING OPEN/CLOSED LIGHTS ON ORDER CANOPY. AT EXISTING BUILDINGS STUB A 3" CHASE THRU THE EXTERIOR WALL FROM THE CEILING SPACE ABOVE THE KITCHEN TO ABOVE THE CANOPY'S COLUMN FOR THE MC CABLE POWER CIRCUITS TO GO THRU THE COLUMN MOUNTED SWITCHES AND OUTLET. ALL CONDUIT AND BOXES SHALL BE CONCEALED FROM NORMAL VIEW; UNDERGROUND, IN COLUMNS, OR ABOVE THE CANOPY (ON THE ROOF). MC CABLE (GALVANIZED STEEL WITH PVC JACKET) TO BE USED INSIDE THE COLUMNS, BUT MUST CONVERT BACK TO IMC ABOVE THE ROOF. ALL EXPOSED ELECTRICAL BOXES TO BE NEMA 3R CAST-METAL. PROVIDE ONE DUPLEX GFCI (WITH IN-USE WP COVER PLATE) AND TWO 120V SINGLE-POLE SWITCHES (EACH WITH HUBBELL #RW51550 WP COVER PLATE) ,AND ONE DUPLEX SINGLE- POLE SWITCH (WITH HUBBELL #RW51470 WP COVER PLATE) MOUNTED ON THE COLUMN IN FLUSH MOUNTED METAL SINGLE GANG BOXES FOR LOCAL ON-OFF CONTROL OF THE FAN, HEATERS, AND CANOPY LIGHTS. SEE WIRING SCHEMATIC AND CANOPY COLUMN DETAILS FOR FURTHER INFORMATION. ALL SURFACE MOUNTED ITEMS AND COVER PLATES TO BE FIELD PAINTED MATTE BLACK. INSTALL BLANK COVERPLATE WHEN HEATERS ARE NOT INSTALLED AND THE THIRD SWITCH IS NOT REQUIRED. AIR CIRCULATING FAN (WITH INTEGRAL ON-OFF SWITCH) PROVIDED BY OTHERS. PROVIDE A GFCI DUPLEX OUTLET (WITH IN-USE WP COVER PLATE) FLUSH MTD. IN CUT-OUT FOR FAN'S PLUG & CORD. LOCATE CUT-OUT AT TOP OF COLUMN ON DOWNSTREAM SIDE.PROVIDE ONE (1) 20A/1P CIRCUIT FOR LIGHTS AND ONE (1) 20A/1P CIRCUIT FOR FANS. CONNECT TO NEXT AVAILABLE SPARE/SPACE IN LIGHTING PANEL FOR EACH. CONTRACTOR SHALL PROVIDE APPROPRIATE BREAKER SIZE AND LOAD. LIGHTING LOAD ON CIRCUIT NOT TO EXCEED 1.8 KW. FIELD VERIFY NUMBER OF SPARES/SPACES PRIOR TO BID. REPORT ANY DISCREPANCIES TO ENGINEER PRIOR TO CONSTRUCTION. PROVIDE ONE (1) #8 CU EQUIPMENT GROUND TO BE BONDED TO CANOPY STRUCTURE AND GAS PIPING PER MANUFACTURER'S RECOMMENDATIONS. NOTES: FOR ALL CONDUITS: REFER TO PLANS FOR OTHER CONDUITS, REFER TO VENDOR DRAWINGS FOR CONDUIT AND WIRING REQUIREMENTS FOR LOW VOLTAGE SYSTEMS AND CONTROL WIRING. MULTIPLE 1PH CIRCUITS MAY OCCUPY THE SAME CONDUIT IN ACCORDANCE WITH THE NEC, MAXIMUM OF THREE AND OF DIFFERENT PHASES. LOW VOLTAGE AND CONTROL WIRING SHALL BE IN SEPARATE CONDUIT FROM BUILDING TO CANOPY. 11 1 1 1 444 4 4 4 333 3 3 3 13 14 PROVIDE NEW OPEN/CLOSED LIGHTS ON FOR NEW ORDER POINT TO MATCH EXISTING . CONNECT TO SAME CIRCUIT AND CONTROL AS EXISTING LIGHT NEW ORDER POINT WITH CANOPY. 2" UNDERGROUND SCH40 PVC CONDUIT WITH POWER CONDUCTORS, SEE WIRING SCHEMATIC. 1" EMPTY UNDERGROUND SCH40 PVC CONDUIT FOR AUDIO SYSTEM/DETECTOR LOOP CABLES. 12 10 1111 1 1 1 1 3 33 13 11 AIR CIRCULATION FAN ( WITH INTEGRAL ON-OFF SWITCH ) PROVIDED BY OTHERS. AT THIS FAN OUTLET LOCATION, EC SHALL PROVIDE GFCI DUPLEX OUTLET (WITH IN-USE WP COVER PLATE) SURFACE MOUNTED ON CANOPY COLUMN FOR FAN'S PLUG AND CORD TO AVOID HAVING BOTH ELECTRICAL AND GAS PIPING INSIDE THE SAME COLUMN LOCATE OUTLET AT TOP OF COLUMN ON DOWNSTREAM SIDE. 4 PROVIDE (2)2" UNDERGROUND SCH40 PVC CONDUITS FOR MENU BOARD FIBER. PROVIDE PULL STRING. STUB UP INTO ACCESSIBLE CEILING SPACE AT OFFICE 15 16 12 2 5 6 1516 7 9 7 8 19 20 21 21 p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360 E1.1.dwg Sheet No: 50-3688-E1.1 - POWER AND LIGHTING PLAN - DUAL Saved by: maribr - Tuesday, July 12, 2022 2:52 PM Printed by: Jonathan Fiesta - July 12, 2022 2:52 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 09/30/2022 JONLOP - 07/12/2022 4:13:37 PM NOTE: THE SWITCHES AND THE DUPLEX OUTLET ARE TO BE ON THE SIDE OF THE COLUMN FACING THE MENUBOARD (ORDERING POINT) WITH THE LEAST VISIBLITY FOR ONCOMING VEHICLES IN THE DT ORDERING LANES TO SEE THESE ITEMS. CANOPY COLUMN SINGLE-GANG OPENING (BY THE CANOPY COLUMN SUPPLIER) FOR THE CONTRACTOR FURNISHED "RETROFIT" SINGLE-GANG BACKBOX TO FLUSH MOUNT IN THE COLUMN FACE (TOWARDS THE ORDERING STATION) DEEP SINGLE-GANG METAL FLUSH MOUNTED BOX FOR SWITCH OR RECEPTACLE WITH RETROFIT CLIPS AND/OR TABS FOR MOUNTING INTO THE OPENING. SEAL AROUND BOX AFTER INSTALLING ON THE COLUMN (TYP) DEEP SINGLE-GANG METAL FLUSH MOUNTED BOX FOR SWITCH OR RECEPTACLE WITH RETROFIT CLIPS AND/OR TABS FOR MOUNTING INTO THE OPENING. SEAL AROUND BOX AFTER INSTALLING ON THE COLUMN (TYP) FINISH SLAB 0'-0" SIDEWALK 1'-6" GFCI RECEPTACLE 4'-0" SWITCH FOR FANS 4'-8" SWITCH FOR HEATERS 3'-4" SWITCH FOR LIGHTS NOTE: THE CUTOUTS FOR THE SWITCHES AND THE RECEPTACLE OUTLET WILL BE ON THE PICK-UP WINDOW SIDE OF THE COLUMN - SHOWN ON THE SIDE FOR ILLUSTRATION PURPOSES. ACCESS HOLE WITH COVER PLATE PROVIDED BY THE CANOPY SUPPLIER IN THE COLUMN AND BEAMS VERIFY INSPECTION ACCESS CUT-OUT AND PLATE WITH STRUCTURE DRAWINGS FOR NEW BUILDINGS: 3" PVC CONDUIT CHASE WITH GALVANIZED STEEL W/ PVC JACKET MC CABLES TO THE EXISTING ELECTRIC ROOM MC CABLE ELBOW OR STRAIGHT CONNECTOR WITH THREADED THROAT FOR CONNECTION TO THE BACK OF THE BACKBOX (TYP) GALVANIZED STEEL WITH PVC JACKET MC CABLES WITHIN THE CANOPY COLUMN. COORDINATE THE INSTALLATION (AND LOCATION OF HANDHOLES, KNOCKOUTS, ETC) WITH THE CANOPY SUPPLIER AND INSTALLER. NEMA 3R JUNCTION BOX ON THE ROOF SIDE OF THE CANOPY CEILING TO TRANSITION FROM THE MC CABLES IN THE COLUMN TO IMC CONDUIT ON THE ROOF TO THE LIGHTS, FANS, AND HEATERS. SEAL THE BOTTOM OF THE BOX TO THE ROOF DECKING. THE MC CABLE BETWEEN THE RECEPTACLE AND THE SWITCH SHALL ALSO INCLUDE THE PHOTOCELL OVERRIDE CONDUCTORS FINISH SLAB 0'-0" SIDEWALK 1'-6" GFCI RECEPTACLE 4'-0" SWITCH FOR FANS 4'-8" SWITCH FOR HEATERS 3'-4" SWITCH FOR LIGHTS NOTE: THE CUTOUTS FOR THE SWITCHES AND THE RECEPTACLE OUTLET WILL BE ON THE ORDER POINT SIDE OF THE COLUMN - SHOWN ON THE SIDE FOR ILLUSTRATION PURPOSES. ACCESS HOLE WITH COVER PLATE PROVIDED BY THE CANOPY SUPPLIER IN THE COLUMN AND BEAMS VERIFY INSPECTION ACCESS CUT-OUT AND PLATE WITH STRUCTURE DRAWINGS 3" PVC CONDUIT CHASE WITH GALVANIZED STEEL W/ PVC JACKET MC CABLES TO THE EXISTING IN GROUND QUAZITE PULL BOX MC CABLE ELBOW OR STRAIGHT CONNECTOR WITH THREADED THROAT FOR CONNECTION TO THE BACK OF THE BACKBOX (TYP) GALVANIZED STEEL WITH PVC JACKET MC CABLES WITHIN THE CANOPY COLUMN. COORDINATE THE INSTALLATION (AND LOCATION OF HANDHOLES, KNOCKOUTS, ETC) WITH THE CANOPY SUPPLIER AND INSTALLER. NEMA 3R JUNCTION BOX ON THE ROOF SIDE OF THE CANOPY CEILING TO TRANSITION FROM THE MC CABLES IN THE COLUMN TO IMC CONDUIT ON THE ROOF TO THE LIGHTS, FANS, AND HEATERS. SEAL THE BOTTOM OF THE BOX TO THE ROOF DECKING. THE MC CABLE BETWEEN THE RECEPTACLE AND THE SWITCH SHALL ALSO INCLUDE THE PHOTOCELL OVERRIDE CONDUCTORS 4 DUAL LANE ORDER CANOPY POWER WIRING SCHEMATIC SCALE: NTS 3 MEAL DELIVERY CANOPY POWER WIRING SCHEMATIC SCALE: NTS 1 SUNCOAST PANEL WIRING DIAGRAM - INFRARED HEATERS, COOLING FANS SCALE: NTS 2 SECTION - MEAL DELIVERY CANOPY COLUMN SCALE: NTS 5 CANOPY COLUMN ISOMETRIC SCALE: NTS 6 SECTION - ORDER CANOPY COLUMN SCALE: NTS ALTERNATE LOCATION FOR THE 3" CHASE FOR EXISTING BUILDINGS. MC CABLES TO BE ROUTED FROM THE CEILING SPACE, DOWN TO THE SWITCHES AND RECEPTACLE OUTLET, THEN UP TO THE JUNCTION BOX ABOVE THE CANOPY ROOF/CEILING. LABELING: PROVIDE ENGRAVED LABEL AT SWITCHES WITH 12'' HIGH WHITE LETTERS ON BLACK BACKGROUND IDENTIFYING UNIT SERVED. STORE SWITCH IN "STORE OPEN" POSITION A. INFRARED HEATERS ARE ENABLED. B. COOLING FANS ARE ENABLED. C. LIGHTS ARE ENABLED. D. MASTER AUTO/OFF SWITCH FOR IR HEATERS AND COOLING FANS PROVIDE SINGLE POINT OF ON/OFF CONTROL. STORE SWITCH IN "STORE CLOSED" POSITION A. INFRARED HEATERS ARE DISABLED. B. COOLING FANS ARE DISABLED. C. LIGHTS ARE DISABLED. SEQUENCE OF OPERATION TB-1 NEUTRAL 120VAC SYSTEM ON BLDG LIGHTS AUTO BLDG LIGHTS ON LOT LIGHTS AUTO HESS SW NEUTRAL HESS SW 120VAC 1 2 3 4 5 6 H1 H2 HESS RETURN WHT BLK TB-2 N 4a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p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360 E1.2.dwg Sheet No: 50-3688-E1.2 - ELECTRICAL DETAILS - HARD CANOPY Saved by: maribr - Tuesday, July 12, 2022 2:51 PM Printed by: Jonathan Fiesta - July 12, 2022 2:52 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 09/30/2022 JONLOP - 07/12/2022 4:13:31 PM p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360 E1.3 - TITLE 24.dwg Sheet No: 50-3688-E1.3 TITLE 24 Saved by: jonfie - Tuesday, July 12, 2022 3:24 PM Printed by: Jonathan Fiesta - July 12, 2022 3:24 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 09/30/2022 JONLOP - 07/12/2022 4:13:24 PM LEGEND CF#1 CIRCULATING FAN #1 (TYP) GIH#1 GAS INFRARED HEATER #1 (TYP) NEW GAS PIPING ABOVE GRADE NEW GAS PIPING BELOW GRADE B/G BELOW GRADE EC ELECTRICAL CONTRACTOR MC MECHANICAL CONTRACTOR FAN CANOPY COLUMN CANOPY PERIMETER CHANNEL, PAINT PT-1 GAS-FIRED INFRARED HEATER. MC TO ATTACH TO MOUNTING PLATE ON CANOPY. MOUNTING PLATE IS PROVIDED AND INSTALLED BY THE CANOPY MFR. TYPICAL AT ALL IR HEATERS. IR HEATER SS HEAT SHIELD. PURCHASE DIRECTLY FROM TOM BARROW COMPANY. CONTACT SCOTT GEORGE AT 404-351-1010 GENERAL NOTES 1. COORDINATE NEW WORK WITH EXISTING CONDUIT, STRUCTURE, AND PIPING. FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. 2. COORDINATE LOCATION AND RESPONSIBILITIES FOR UNDERGROUND PIPING AND ASSOCIATED TRENCHING WITH GENERAL CONTRACTOR PRIOR TO START OF WORK. 3. EXPOSED GAS PIPING SHALL BE PAINTED BY GENERAL CONTRACTOR. USE ANTI-CORROSIVE PAINT AND COORDINATE WITH CFA CONSTRUCTION MANAGER. 1. SCHWANK INFRARED HEATER PACKAGE - THE MECHANICAL CONTRACTOR IS REQUIRED TO PURCHASE THE HEATER PACKAGE DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. HEATERS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. 2. COOK FAN PACKAGE - THE MECHANICAL CONTRACTOR IS REQUIRED TO PURCHASE THE FAN PACKAGE DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. FANS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. NATIONAL ACCOUNTS NOTE! AS NOTED IN THE SPECIFICATIONS, ALL WIRING LAYOUTS, PIPING LAYOUTS AND DUCT LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS SHALL BE DETERMINED BY THE CONSTRUCTION AND STRUCTURE OF THE BUILDING AND SHALL BE VERIFIED AND COORDINATED IN THE FIELD. EACH TRADE CONTRACTOR SHALL VERIFY WITH THE GENERAL CONTRACTOR THAT HE HAS THOROUGHLY REVIEWED AND COORDINATED ALL LOCATIONS AND ROUTINGS WITH ALL OTHER TRADES PRIOR TO FABRICATION OF CONDUITS, DUCTS, OR PIPING, AND START OF INSTALLATION OF SAME (INCLUDING SPRINKLER PIPING WHEN PRESENT ON JOB). ANY INSTALLATION OR CONSTRUCTION CONFLICTS WHICH OCCUR IN THE FIELD SHALL BE RESOLVED BY THE TRADE CONTRACTOR TO THE SATISFACTION OF THE OWNER AND ARCHITECT AND AT NO EXPENSE TO THE OWNER, ARCHITECT AND/OR GENERAL CONTRACTOR. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. FIELD VERIFY ALL CONDITIONS GIH#3 GIH#6 GIH#2 GIH#5 CF#1 CF#2 CF#6CF#4 3/4 " GAS 1-1/4'' GAS 3/4 " GAS 1 " GAS 1 1/2'' GAS 1 1/2'' GAS B/G ATTACH GAS TRANSITION FITTING, ELSTER 702205 OR EQUAL BY GASTITE, TO GAS PIPE STUB-OUT BELOW GRADE. GAS PIPING INSIDE COLUMN AND STUB-OUTS BY CANOPY MFR (LANE SUPPLY). JOIN UNDERGROUND POLYETHYLENE GAS PIPING TO TRANSITION FITTING WITH ELSTER PERMASERT COUPLING. CANOPY MFR'S EXPOSED STEEL GAS PIPING BELOW GRADE SHALL BE PROTECTED WITH TWO COATS ASPHALTUM BASE PAINT AND POLY SLEEVE. CONNECT 1-1/2" GAS TO CANOPY MFR GAS PIPE STUB-OUT FROM COLUMN ABOVE DECK. GAS PIPING TO BE ROUTED ABOVE CANOPY, ON TOP OF STRUCTURAL MEMBERS, EXCEPT WHERE ROUTED DOWN THROUGH PENETRATIONS AS INDICATED. ORDER CANOPY. SEE ARCHITECTURAL. ROUTE POLYETHYLENE GAS B/G TO THE METER. FOR TRANSITION FROM POLYETHYLENE PIPING B/G TO STEEL AT THE METER, INSTALL ANODELESS RISER WITH INTEGRAL CONST AB PE-TO-IPS TRANSITION FITTING BY CONTINENTAL INDUSTRIES OR EQUAL BY ELSTER. PROVIDE FULL PORT BALL VALVE EQUAL TO APOLLO 50GB SERIES WITH WING HANDLE OPTION ABOVE GRADE AT THE METER. PROVIDE BRASS VALVE TAG WITH JACK CHAIN AT VALVE MARKED "SERVICE SHUTOFF FOR CANOPY". MOUNT FAN TO OVERHEAD STRUCTURAL MEMBER USING STAINLESS MOUNTING HARDWARE. SEE SHEET 2/P1.2. GIH#4CF#3 GIH#7CF#5 1 " GAS 3/4 " GAS 3/4 " GAS MOUNT COOLING FAN TO OVERHEAD STRUCTURAL MEMBERS. SEE CANOPY MFR DETAILFOR MOUNTING. TYPICAL AT ALL FANS. HEATER HEAT SHIELD TO SET ON TOP OF IR HEATER ON THE FACTORY HEATER MOUNTING STUDS. SHIELD TO ORIENTED SO EDGE IS TURNED DOWN. SEE 2/P1.1 FOR MOUNTING (TYP ALL GIHS) PIPING DOWN THRIUGH DECK. WEATHERPROOF DECK PENERATION FOR PIPING AND CONDUIT PER DETAIL 3/4" GAS TAKE OFF TO GIH. TYPICAL IF REQUIRED BY AHJ, PROVIDE A SIGN STATING "EMERGENCY GAS SHUTOFF ON ROOF", AND LOCATE PER AHJ'S DIRECTION ALL NATURAL GAS PIPING SHALL BE SHEDULE 40 BLACK STEEL MEETING ASTM A53 WITH SCREWED OR WELDED FITTINGS AND GASKET TYPE UNIONS AND FLANGES.p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360-P1.2.dwg Sheet No: P1.2 -GAS PLUMBING PLAN Saved by: jonfie - Thursday, June 23, 2022 4:13 PM Printed by: Jonathan Fiesta - July 12, 2022 2:53 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 12/31/2023 JONLOP - 07/12/2022 4:13:44 PM CF#8 LEGEND CF#1 CIRCULATING FAN #1 (TYP) GIH#1 GAS INFRARED HEATER #1 (TYP) NEW GAS PIPING ABOVE GRADE NEW GAS PIPING BELOW GRADE B/G BELOW GRADE EC ELECTRICAL CONTRACTOR MC MECHANICAL CONTRACTOR DOWNSPOUT NOZZLE, TYP CANOPY PERIMETER CHANNEL, PAINT PT-1 GAS-FIRED INFRARED HEATER. MC TO ATTACH TO MOUNTING PLATE ON CANOPY. MOUNTING PLATE IS PROVIDED AND INSTALLED BY THE CANOPY MFR. TYPICAL AT ALL IR HEATERS. MOUNT COOLING FAN TO OVERHEAD STRUCTURAL MEMBERS. SEE CANOPY MFR DETAILFOR MOUNTING. TYPICAL AT ALL FANS. CENTER FIRST BAY ON DRIVE-THRU WINDOWHEATER CANOPY COLUMN FAN IR HEATER HEAT SHIELD TO SET ON TOP OF IR HEATER ON THE FACTORY HEATER MOUNTING STUDS. SHIELD TO ORIENTED SO EDGE IS TURNED DOWN. SS HEAT SHIELD. PURCHASE DIRECTLY FROM TOM BARROW COMPANY. CONTACT SCOTT GEORGE AT 404-351-1010 GAS PIPING TO BE ROUTED ABOVE CANOPY, ON TOP OF STRUCTURAL MEMBERS, EXCEPT WHERE ROUTED. DOWN THROUGH PENETRATIONS AS INDICATED GAS LINE ON ROOF. PROVIDE FULL PORT BALL VALVE EQUAL TO APOLLO 50GB SERIES WITH WING HANDLE OPTION ON BUILDING ROOFTOP. PROVIDE BRASS VALVE TAG WITH JACK CHAIN AT VALVE MARKED "SERVICE SHUTOFF FOR CANOPY". CAN ROUTE UP AND OVER PARAPET AND DOWN ALONG WALL OR THROUGH PARAPET. PAINT TO MATCH ADJACENT PENETRATE PARAPET, AND ROUTE GAS LINE DOWN ALONG EXTERIOR WALL TO 12" ABOVE TOP OF CANOPY. SEE ARCHITECTURAL SHEETS FOR PARAPET PENETRATION DETAIL ROOF CONNECTION: NEW 3/4" GAS TO BE CONNECTED TO EXISTING GAS PIPING ON ROOF. MAKE CONNECTION CLOSE TO METER WHERE EXISTING SERVICE COMES ONTO ROOF. MUST CONNECT TO EXISTING LINE MINIMUM ONE SIZE LARGER THAN CANOPY SERVICE BRANCH SIZE SHOWN. COORDINATE ADDITIONAL LOAD ON METER WITH GAS UTILITY COMPANY. CF#7 GIH#7 3/4'' GAS TAKE OFF TO GIH, TYPICAL IF REQUIRED BY AHJ, PROVIDE A SIGN STATING "EMERGENCY GAS SHUTOFF ON ROOF", AND LOCATE PER AHJ'S DIRECTION MEAL DELIVERY CANOPY. SEE ARCHITECTURAL. GENERAL NOTES 1. COORDINATE NEW WORK WITH EXISTING CONDUIT, STRUCTURE, AND PIPING. FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. 2. COORDINATE LOCATION AND RESPONSIBILITIES FOR UNDERGROUND PIPING AND ASSOCIATED TRENCHING WITH GENERAL CONTRACTOR PRIOR TO START OF WORK. 3. EXPOSED GAS PIPING SHALL BE PAINTED BY GENERAL CONTRACTOR. USE ANTI-CORROSIVE PAINT AND COORDINATE WITH CFA CONSTRUCTION MANAGER. 1. SCHWANK INFRARED HEATER PACKAGE - THE MECHANICAL CONTRACTOR IS REQUIRED TO PURCHASE THE HEATER PACKAGE DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. HEATERS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. 2. COOK FAN PACKAGE - THE MECHANICAL CONTRACTOR IS REQUIRED TO PURCHASE THE FAN PACKAGE DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. FANS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. NATIONAL ACCOUNTS NOTE! AS NOTED IN THE SPECIFICATIONS, ALL WIRING LAYOUTS, PIPING LAYOUTS AND DUCT LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS SHALL BE DETERMINED BY THE CONSTRUCTION AND STRUCTURE OF THE BUILDING AND SHALL BE VERIFIED AND COORDINATED IN THE FIELD. EACH TRADE CONTRACTOR SHALL VERIFY WITH THE GENERAL CONTRACTOR THAT HE HAS THOROUGHLY REVIEWED AND COORDINATED ALL LOCATIONS AND ROUTINGS WITH ALL OTHER TRADES PRIOR TO FABRICATION OF CONDUITS, DUCTS, OR PIPING, AND START OF INSTALLATION OF SAME (INCLUDING SPRINKLER PIPING WHEN PRESENT ON JOB). ANY INSTALLATION OR CONSTRUCTION CONFLICTS WHICH OCCUR IN THE FIELD SHALL BE RESOLVED BY THE TRADE CONTRACTOR TO THE SATISFACTION OF THE OWNER AND ARCHITECT AND AT NO EXPENSE TO THE OWNER, ARCHITECT AND/OR GENERAL CONTRACTOR. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. FIELD VERIFY ALL CONDITIONS CF#9 MOUNT FAN TO OVERHEAD STRUCTURAL MEMBER USING STAINLESS MOUNTING HARDWARE. SEE SHEET 2/P1.1. SEE 2/P1.2 FOR MOUNTING (TYP ALL GIH'S) PIPING DOWN THRIUGH DECK. WEATHERPROOF DECK PENERATION FOR PIPING AND CONDUIT PER DETAIL ALL NATURAL GAS PIPING SHALL BE SHEDULE 40 BLACK STEEL MEETING ASTM A53 WITH SCREWED OR WELDED FITTINGS AND GASKET TYPE UNIONS AND FLANGES.p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360-P1.1.dwg Sheet No: P1.1 -GAS PLUMBING PLAN Saved by: jarrus - Monday, April 25, 2022 5:05 PM Printed by: Jonathan Fiesta - July 12, 2022 2:53 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 12/31/2023 JONLOP - 07/12/2022 4:13:16 PM HEAVY DUTY 100% RECYCLED RUBBER BASE WITH FACTORY REFLECTIVE RED WARNING STRIPE COOPER B-LINE DURA-BLOK DB SERIES SHOWN GAS PIPING ON ROOF PIPE CLAMP ONE SIZE LARGER THAN PIPE DIAMETER. SECURE CLAMP TO STRUT WITH B-LINE CONNECTORS STRUT. FIELD ADJUST TO KEEP STRUT LEVEL. PIPE SHALL FOLLOW SLOPE OF ROOF SET ON ROOF MFR APPROVED PAD NOTES: 1. NON ADJUSTABLE MODEL DB610 PIPE STAND TO BE USED FOR NON-ELEVATED PIPING INSTALLED FLAT ON ROOF DECK. 2. PROVIDE MODEL DBE 10-8 OR DBE 10-12 OR DBE 10-16 AS NEEDED FOR ELEVATING PIPING FOR GAS PIPING CROSSING OVER CONDENSATE PIPING. 3. ENSURE GAS PIPING DOES NOT OBSTRUCT ROOFTOP EQUIPMENT ACCESS OPENINGS. RE-PIPING OF SYSTEMS DUE TO CONFLICTS WITH EQUIPMENT ACCESS OPENINGS SHALL BE DONE AT PLUMBING CONTRACTOR'S EXPENSE. DISTANCE BETWEEN PIPE STANDS NOT TO EXCEED 8'-0" NOTES: 1. DISTANCE BETWEEN PIPESTANDS NOT TO EXCEED 8'-0". 2. MC TO PROVIDE DUAL LEVEL SUPPORT TO ACCOMMODATE BOTH GAS PIPING AND CONDUIT. GAS PIPING AND CONDUIT ON ROOF ADD SECOND LEVEL WHERE ROUTING BOTH GAS PIPING AND CONDUIT ALONG SAME STRUCTURAL MEMBER. FIELD ADJUST HEIGHT TO MAINTAIN PIPING LEVEL ACROSS THE ROOF. ATTACH SUPPORT PAD TO CANOPY BEAM WITH SELF-TAPPING FASTENERS. CANOPY BEAM MIRO INDUSTRIES PIPESTAND GAS INFRARED HEATER AGA LISTED GAS COCK GAS PIPING CANOPY STRUCTUREAGA LISTED FLEXIBLE CSST CONNECTION. EQUAL TO DORMONT SUPR-SAFE STAINLESS STEEL GAS CONNECTOR, 24" LENGTH OR LONGER SEE WEATHERPROOFING DETAIL THIS SHEET SEE PIPE SUPPORT DETAIL THIS SHEET ATTACH TO DECK WITH #8 STAINLESS WASHER HEAD SCREWS EQUAL TO FASTENAL. MIN 4 SCREWS ARRANGED IN SYMMETRICAL PATTERN AT 0, 90, 180 AND 270 DEGREES. CANOPY DECK FULL PERIMETER APPLICATION BETWEEN BOOT COLLAR AND DECK WITH GEOCEL 2300. PORTALS PLUS DECKMATE FLASHING SYSTEM. INSTALL PER MANUFACTURER'S INSTRUCTIONS. STAINLESS STEEL BAND CLAMP GAS PIPING OR CONDUIT EQUIPMENT GAS CONNECTION SCHEDULE REMARKS: GAS LOAD 1. EQUIVALENT TO 1,580 CFH @ pressure drop 0.5 IN. W.C. W/ DEVELOP LENGTH OF 150 FT (METER TO GIH#7) 2. 7" w.c. DELIVERY PRESSURE. 3. VERIFY GAS LOAD OF EXISTING EQUIPMENT. EXISTING AC#3 NEW GAS HEATERS (7)(7) 50,000 BTU'S EXISTING AC#2 EXISTING AC#1 WATER HEATER 240,000 BTU'S 480,000 BTU'S EXISTING AC#4 CONTRACTOR TO VERIFY EXISTING GAS SYSTEM CAN HANDLE NEW GAS LOAD. RESIZE AND INSTALL NEW GAS PIPING AS REQUIRED IF EXISTING GAS PIPING IS UNDERSIZED FOR NEW GAS LOAD AND PIPE LENGTH. FIELD VERIFY EXACT CONDITIONS PRIOR TO BID. NOTE: GAS FIRED INFRARED HEATER SCHEDULE MARK INPUT (MBH) FRAME SIZE MOUNTING TYPE MODEL MANUFACTURER LENGTH WIDTH DEPTH GIH 50.0 48" 13" 10" BRACKET 2352-NG SCHWANK REMARKS 1. STEEL BURNER WITH CERAMIC BURNER TILES. 2. STAINLESS STEEL LENS WITH BLOCK EMISSIVE COATING. 3. PROVIDE ENGRAVED PLASTIC LABEL AT EACH UNIT WITH UNIT DESIGNATION IN 1" HIGH WHITE LETTERS ON A BLACK BACKGROUND. MOUNT TO CANOPY DECK, FACING DOWNWARD, 12" LATERALLY FROM THE SIDE OF THE HEATER 4. MOUNTING BRACKET PROVIDED AND INSTALLED BY CANOPY MFR. 5. PROVIDE HEAT SHIELD ABOVE EACH HEATER AT THE BOTTOM OF THE BRACKET. TOTAL CONNECTED LOAD 1,580,000 BTU'S 120,000 BTU'S 150,000 BTU'S 1'-0" 8"2'-0"1'-6"FROM TOP OFPAVEMENTNOTE: SEALANT USED AT ALL CANOPY PENETRATIONS TO BE GE SILICONE, DOW 795 WHITE OR CLEAR. REF PLANS FOR WALL TYPE BAKER ROD VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY. COORDINATE WITH GAS COMPANY WITH REGARD TO INSTALLATION OF OTHER PLUMBING UTILITIES IN THE VICINITY, IF ANY. APPLY FOR AND PAY GAS COMPANY FEES FOR INSTALLATION. USE PIPE AND FITTINGS PER PLUMBING SPECIFICATIONS. CIRCULATING FAN SCHEDULE MARK CFM RPM HP MODEL MANUFACTURER CF 5,750 1,625 1/8 U18TE-HD TPI REMARKS 1. ALUMINUM PADDLE WITH STEEL HUB/SPIDER PROPELLER 2. 360° ROTATING HEAD HORIZONTALLY AND VERTICALLY 3. OSHA COMPLIANT DOUBLE LOCKING, COATED STEEL WIRE GUARD 4. 3-SPEED, TOTALLY ENCLOSED, PERMANENTLY LUBRICATED BALL BEARING MOTOR 5. FACTORY PRE-WIPED POWER CORD 6. PROVIDE FACTORY WALL MOUNTING BRACKET. SEE DETAIL 3/M2.1 FOR TYPICAL INSTALLATION INSTRUCTIONS 7. PROVIDE ENGRAVED PLASTIC LABEL AT EACH UNIT WITH UNIT DESIGNATION IN 1" HIGH WHITE LETTERS ON A BLACK BACKGROUND. MOUNT TO UNDERSIDE OF CANOPY OR EXISTING OVERHANG, FACING DOWNWARD, 12" LATERALLY FROM THE FAN LOCATION 8. REMOVE PULL CHAIN EXTENSION AT ON/OFF SWITCH IN FIELD 9. FACTORY CERTIFIED FOR OUTDOOR INSTALLATION. NATIONAL ACCOUNTS 1 SCHWANK INFRARED HEATER PACKAGE - THE MECHANICAL CONTRACTOR IS REQUIRED TO PURCHASE THE HEATER PACKAGE DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. HEATERS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. 2 TPI FAN PACKAGE - THE MECHANICAL CONTRACTOR IS REQUIRED TO PURCHASE THE FAN PACKAGE DIRECTLY FROM TOM BARROW COMPANY. CONTACT MR. SCOTT GEORGE AT 404-351-1010 FOR PRICING AND AVAILABILITY. FANS NOT PURCHASED THRU TOM BARROW COMPANY WILL NOT BE ACCEPTED. IMPORTANT NOTE - PLEASE READ NUMBERS OF GAS INFRARED HEATERS AND CIRCULATING FANS WILL BE DETERMINED BY SITE-SPECIFIC CANOPY LAYOUT AND EQUIPMENT LOCATIONS, AS INDICATED ON ARCHITECTURAL PLANS. GENERAL NOTES 1. COORDINATE NEW WORK WITH EXISTING CONDUIT, STRUCTURE AND PIPING. FIELD VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. 2. COORDINATE LOCATION AND RESPONSIBILITIES FORUNDERGROUND PIPING AND ASSOCIATED TRENCHING WITH GENERAL CONTRACTOR PRIOR TO START OF WORK. 3. EXPOSED GAS PIPING SHALL BE PAINTED BY GENERAL CONTRACTOR. 1-1/2" Ø BLACK PIPE ELBOW AND NIPPLE GAS PIPE COVER BY CANOPY MFR - COLOR TO MATCH COLUMN HAND HOLE, SHOP LOCATED 1-1/2"Ø BLACK PIPE FOR GAS LINE 240,000 BTU'S p:\C\chickfila\2021.0360 - cfa - custom project - fsu 3688 - rohnert park, rohnert park, ca\3 cad & drawings\2 construction documents\2021.0360-P2.1.dwg Sheet No: P2.1 -PLUMBING DETAILS Saved by: jarrus - Monday, April 25, 2022 4:57 PM Printed by: Jonathan Fiesta - July 12, 2022 2:53 PMCOPYRIGHT c2022 DAVID BOYCE RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.DAVID BOYCE ARCHITECT 220 E. CENTRAL PKWY, STE 4000 ALTAMONTE SPRINGS, FL 32701 407.645.5008 THIS DOCUMENT IS NOT 12/31/2023 JONLOP - 07/12/2022 4:13:50 PM 9841 Irvine Center Drive, Suite 200 | Irvine, California  92618 | 949.878.3509 |www.tjwengineering.com  October 26, 2022  Ms. Lauren Martin  TRUXAW AND ASSOCIATES, INC.  1915 W Orangewood Ave, Suite 101  Orange, CA 92868  Subject: Chick‐Fil‐A Rohnert Park Drive‐Through Queue, Parking, and Circulation Analysis   Dear Ms. Martin:  TJW ENGINEERING, INC. (TJW) is pleased to submit this drive‐through queue, parking, and circulation analysis  for the proposed drive‐through configuration changes at the Chick‐Fil‐A restaurant at 5080 Redwood Drive  in the City of Rohnert Park. This report summarizes the results of site queue observations conducted at the  existing project location plus the project’s effect on parking and on‐site circulation.    Appendix A contains the proposed site plan for the Chick‐Fil‐A restaurant at 5080 Redwood Drive.  The project proposes to expand the drive‐through from one lane to two lanes and allow Chick‐Fil‐A associates  to bring orders to vehicles in the outer lane. The existing drive‐through currently allows approximately eleven  vehicles, and with the addition of the second drive‐through lane there would be a capacity of approximately  30 vehicles (600 feet) before a queue begins to form outside of the drive‐through lanes.   Additionally, the project will reconfigure parking spaces immediately surrounding the Chick‐Fil‐A. This  includes implementing angled parking and repositioning parking spaces, which would result in a decrease of  7 parking spaces.  Drive‐Through Queue Analysis Methodology  Peak periods for Chick‐Fil‐A restaurants are typically weekdays in the morning, lunchtime, and in the evening.   Therefore, site queue observations were conducted on a typical weekday and Saturday from 7:00‐9:00 AM,  11:00 AM‐2:00 PM, and 4:00‐7:00 PM. Data was collected in 10‐minute increments at the existing 5080  Redwood Drive Chick‐Fil‐A location on Friday, March 4, 2022 and Saturday, March 5, 2022.  The data collection resulted in a sample size of 51 data points on each day for a total of 102 data points. The  data collected can be used to determine the 85th percentile queue length, which is typically used to determine  the appropriate vehicle stacking needed for drive‐through restaurants.   ATTACHMENT 2 Chick‐Fil‐A Rohnert Park  Drive‐Through Queue, Parking, and Circulation Analysis  TRX‐22‐004  2  Drive‐Through Queue Observation Results    Based on the collected data, Table 1 shows the number of times a certain queue length occurred (including  vehicles queued outside of the drive‐through storage capacity) and the probability of that queue length not  being exceeded. Complete observation data is provided in Appendix B.    Table 1: Summary of Drive‐Through Queue Observations and Analysis  Drive‐Through Queue Analysis  Queue Length  (Vehicles)  Number of  Occurrences  Total Number of  Data Points  Probability of  Exceeding Queue  Length  0 1 1 99.02%  1 8 9 91.18%  2 4 13 87.25%  3 4 17 83.33%  4 4 21 79.41%  5 3 24 76.47%  6 2 26 74.51%  7 0 26 74.51%  8 0 26 74.51%  9 3 29 71.57%  10 1 30 70.59%  11 5 35 65.69%  12 3 38 62.75%  13 6 44 56.86%  14 4 48 52.94%  15 3 51 50.00%  16 3 54 47.06%  17 5 59 42.16%  18 4 63 38.24%  19 6 69 32.35%  20 6 75 26.47%  21 5 80 21.57%  22 3 83 18.63%  23 2 85 16.67%  24 5 90 11.76%  25 3 93 8.82%  26 2 95 6.86%  27 3 98 3.92%  28 1 99 2.94%  29 2 101 0.98%  30 1 102 0.00%  85th Percentile Info  Queue Length: 24 Vehicles Data Point: 87th     Chick‐Fil‐A Rohnert Park  Drive‐Through Queue, Parking, and Circulation Analysis  TRX‐22‐004  3  When determining the appropriate queue storage, a drive‐through should typically be designed to  accommodate the 85th percentile queue length. Based on the data collected at the existing 5080 Redwood  Drive Chick‐Fil‐A location, the 85th percentile queue length is 24 vehicles which occurred at the 87th data  point. The maximum observed queue was 30 vehicles occurring one time.     As shown in Appendix A, the proposed site reconfiguration will construct a double lane drive‐through with  two order boards and a single pick‐up window, with associates walking orders to vehicles in the outer lane.  Associates will be able to access the outer lane via a striped crosswalk on the west side of the Chick‐Fil‐A. The  drive‐through lane will have room for approximately 30 vehicles (maximum observed) before it would spill  into the nearest drive aisle. As such, queueing at the Chick‐Fil‐A will not affect circulation for the neighboring  Krispy Kreme and Oilstop operations.    In the event that the queue extends beyond 30 vehicles, Chick‐Fil‐A associates can direct traffic through the  drive aisles in the parking lot to stack west of the drive‐through lane entrance along Chick‐Fil‐A’s frontage.  This will leave the Krispy Kreme drive‐through entrance accessible and will only block off parking spaces near  Chick‐Fil‐A itself.    Parking Survey    Site parking inventory and occupancy surveys were also conducted at the existing parking lot shared by Chick‐ Fil‐A, Krispy Kreme, and Oilstop. The surveys identified an inventory of 154 total parking spaces, including 6  handicap (ADA) spaces. The breakdown of parking spaces by zone is provided in Appendix B. The surveys  were conducted on Friday, March 4, 2022 and Saturday, March 5, 2022 from 7:00 AM – 9:00 AM, 11:00 AM  – 2:00 PM, and 4:00 PM – 7:00 PM. These hours were selected based on typical peak periods of parking  demand at Chick‐Fil‐A restaurants. The complete parking data sheets are attached to this letter for reference.  The occupancy surveys were conducted in twenty‐minute intervals to identify peak parking demand. The  results of the occupancy surveys were tabulated and are shown in Table 2 and Table 3.    As shown in Table 2 and Table 3, the total parking inventory for the parcel is 154 spaces. The weekday peak  parking demand at the Chick‐Fil‐A parcel occurred between 1:20 PM and 1:40 PM when a total of 85 spaces  were occupied (55% occupancy) and the weekend peak parking demand occurred between 12:40 PM and  1:00 PM when a total of 98 spaces were occupied (64% occupancy). Across both weekday and weekend days,  parking occupancy did not exceed 64% occupancy.     Based on the observed peak parking demand at the Chick‐Fil‐A parcel, 85 vehicles on the weekday and 98  vehicles on the weekend, the existing parking supply of 154 spaces for the parcel is adequate to  accommodate the existing Chick‐Fil‐A, Krispy Kreme and Oilstop. Additionally, once the drive‐through  reconfiguration is constructed and 7 parking spaces will be removed, the parking supply of 147 spaces will  remain adequate to accommodate the Chick‐Fil‐A, Krispy Kreme and Oilstop. The maximum occupancy of 98  spaces will occupy 67% of the available parking supply.               Chick‐Fil‐A Rohnert Park  Drive‐Through Queue, Parking, and Circulation Analysis  TRX‐22‐004  4    Table 2: Summary of Weekday Parking Demand  Zone A B C D  Total  Occupied  Parking  Spaces  Current Parking Supply  33  Parking  Spaces  15 Parking Spaces 38 Parking Spaces  68  Parking  Spaces  Survey Time Period Regular Regular Handicap Regular Handicap Regular  7:00 AM ‐ 7:20 AM 6 0 0 6 0 13 25  7:20 AM ‐ 7:40 AM 6 0 0 3 0 12 21  7:40 AM ‐ 8:00 AM 6 1 0 3 0 14 24  8:00 AM ‐ 8:20 AM 6 1 0 2 0 16 25  8:20 AM ‐ 8:40 AM 8 1 0 6 0 20 35  8:40 AM ‐ 9:00 AM 10 2 0 8 0 22 42    11:00 AM ‐ 11:20 AM 13 1 0 11 0 33 58  11:20 AM ‐ 11:40 AM 14 1 0 18 0 38 71  11:40 AM ‐ 12:00 PM 13 1 0 16 0 41 71  12:00 PM ‐ 12:20 PM 10 1 0 18 1 32 62  12:20 PM ‐ 12:40 PM 10 1 0 18 1 43 73  12:40 PM ‐ 1:00 PM 12 1 0 17 1 51 82  1:00 PM ‐ 1:20 PM 13 1 0 17 1 50 82  1:20 PM ‐ 1:40 PM 14 1 0 22 0 48 85  1:40 PM ‐ 2:00 PM 14 2 0 17 0 42 75    4:00 PM ‐ 4:20 PM 13 3 0 17 0 39 72  4:20 PM ‐ 4:40 PM 12 3 0 15 0 38 68  4:40 PM ‐ 5:00 PM 13 3 0 10 0 44 70  5:00 PM ‐ 5:20 PM 13 0 0 17 0 44 74  5:20 PM ‐ 5:40 PM 12 0 0 19 1 46 78  5:40 PM ‐ 6:00 PM 14 0 0 19 2 43 78  6:00 PM ‐ 6:20 PM 15 1 0 20 0 45 81  6:20 PM ‐ 6:40 PM 12 1 0 23 1 35 72  6:40 PM ‐ 7:00 PM 12 0 0 26 1 35 74                    Chick‐Fil‐A Rohnert Park  Drive‐Through Queue, Parking, and Circulation Analysis  TRX‐22‐004  5    Table 3: Summary of Weekend Parking Demand  Zone A B C D  Total  Occupied  Parking  Spaces  Current Parking Supply  33  Parking  Spaces  15 Parking Spaces 38 Parking Spaces  68  Parking  Spaces  Survey Time Period Regular Regular Handicap Regular Handicap Regular  7:00 AM ‐ 7:20 AM 10 2 0 2 0 12 26  7:20 AM ‐ 7:40 AM 10 0 0 1 0 11 22  7:40 AM ‐ 8:00 AM 10 0 0 2 0 11 23  8:00 AM ‐ 8:20 AM 10 1 0 5 0 16 32  8:20 AM ‐ 8:40 AM 11 1 0 3 0 18 33  8:40 AM ‐ 9:00 AM 12 2 0 4 0 23 41    11:00 AM ‐ 11:20 AM 15 2 0 11 0 34 62  11:20 AM ‐ 11:40 AM 15 2 0 14 0 35 66  11:40 AM ‐ 12:00 PM 16 2 0 12 0 42 72  12:00 PM ‐ 12:20 PM 15 2 0 16 0 45 78  12:20 PM ‐ 12:40 PM 17 3 0 15 0 50 85  12:40 PM ‐ 1:00 PM 16 1 0 25 1 55 98  1:00 PM ‐ 1:20 PM 16 3 0 20 0 50 89  1:20 PM ‐ 1:40 PM 15 4 0 24 1 53 97  1:40 PM ‐ 2:00 PM 13 4 0 19 0 53 89    4:00 PM ‐ 4:20 PM 9 0 0 15 1 46 71  4:20 PM ‐ 4:40 PM 10 0 0 18 0 43 71  4:40 PM ‐ 5:00 PM 12 0 0 18 0 36 66  5:00 PM ‐ 5:20 PM 14 3 0 20 1 38 76  5:20 PM ‐ 5:40 PM 14 1 0 21 1 40 77  5:40 PM ‐ 6:00 PM 14 0 0 17 0 42 73  6:00 PM ‐ 6:20 PM 15 1 0 21 0 44 81  6:20 PM ‐ 6:40 PM 15 3 0 22 0 51 91  6:40 PM ‐ 7:00 PM 14 5 0 22 0 48 89    On‐Site Circulation  Two separate striped northbound lanes will be provided upon entry from Redwood Drive to allow for access  to each restaurant. Each lane will be marked with directional arrows and striping to direct traffic to the  appropriate drive‐through and prevent conflicts. For vehicles that intend on entering the Chick‐Fil‐A drive‐ through but are instead in the Krispy Kreme drive‐through lane, “One Way” roadway markings will be  provided to lead vehicles around the northside of the Chick‐Fil‐A to enter the drive‐through from the west.  “Keep Clear” markings at the exit of the Krispy Kreme drive‐through will be updated upon reconfiguration of  Chick‐Fil‐A Rohnert Park  Drive‐Through Queue, Parking, and Circulation Analysis  TRX‐22‐004  6  the drive aisle, which will prevent potential spillback from the Chick‐Fil‐A drive‐through from blocking the  Krispy Kreme drive‐through exit.     Customers of Krispy Kreme that do not utilize the drive‐through can park in the lot immediately north or  immediately west of the Krispy Kreme. Krispy Kreme customers parking in the north lot will be routed north  via “One Way” pavement markings around the Chick‐Fil‐A to exit the parking lot via the west driveway.     Parking spaces on the rear of the Chick‐Fil‐A restaurant are, and will continue to be, mainly occupied by  employees. Pedestrian access to these spaces will be provided on the northeast side of Chick‐Fil‐A and on  the south side of Chick‐Fil‐A near the drive‐through entrance.     Chick‐Fil‐A has outlined a traffic management plan in an effort to facilitate faster service and prevent  extensive queuing in the Chick‐Fil‐A drive‐through lane. The traffic management plan includes directions for  4‐5 employees to take orders and accept credit cards, 2 employees to deliver food outside, and two  employees to deliver curbside pick‐up orders to the designated parking spaces. The full outline is provided in  Appendix C.     Conclusion  With the new dual drive‐through configuration, 30 vehicles would be able to queue before spilling into the  nearest drive aisle. The 85th percentile observed queue was 24 vehicles and the maximum observed queue  was 30 vehicles under the existing configuration. Therefore, with the dual drive‐through configuration  implemented, the maximum queue will be accommodated without affecting circulation for the neighboring  Krispy Kreme and Oilstop operations.    The existing shared parking lot for Chick‐Fil‐A, Krispy Kreme, and Oilstop provides 148 standard parking  spaces and 6 handicap (ADA) parking spaces for a total of 154 parking spaces. Once the drive‐through  reconfiguration is constructed, 147 total parking spaces will be provided. Based on parking occupancy counts,  a maximum of 98 spaces were occupied (67% occupancy after reconfiguration). Therefore, additional parking  is not required.    Two separate striped northbound lanes will be provided upon entry from Redwood Drive to allow for access  to each restaurant. Each lane will be marked to direct traffic to the appropriate drive‐through and prevent  conflicts. For vehicles that intend on entering the Chick‐Fil‐A drive‐through but are instead in the Krispy  Kreme drive‐through lane, “One Way” roadway markings will be provided to lead vehicles around the  northside of the Chick‐Fil‐A to enter the drive‐through from the west. “Keep Clear” markings at the exit of  the Krispy Kreme drive‐through will be updated upon reconfiguration of the drive aisle, which will prevent  potential spillback from the Chick‐Fil‐A drive‐through from blocking the Krispy Kreme drive‐through exit.                  Chick‐Fil‐A Rohnert Park  Drive‐Through Queue, Parking, and Circulation Analysis  TRX‐22‐004  7  Please contact us at (949) 878‐3509 if you have any questions regarding this analysis.    Sincerely,      Thomas Wheat, PE, TE                                                                      David Chew, PTP  President                   Transportation Planner    Registered Civil Engineer #69467  Registered Traffic Engineer #2565            Brandon Alvarado, EIT          Transportation Planner        APPENDIX A    SITE PLAN/QUEUE VISUALIZATION   Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 NO.DATE DESCRIPTION5080 REDWOOD DRIVEROHNERT PARK, CAREVISION SCHEDULE A 03688FSR#101 @ GOLF COURSE DRIVE1 B C D E A B C D E 234 1234 D CFA 15019 CD'S 10/04/2022 SGC GRADING PLAN C-300 85th Percentile Queue(24th Vehicle)Maximum Observed Queue(30th Vehicle)     APPENDIX B    DRIVE‐THROUGH QUEUE DATA/PARKING ZONES   LOCATION: Chick‐Fil‐A, 5080 Redwood Drive Date: 3/4/2022 CITY: Rohnert Park Day: Friday TIME Vehicles in Queue TIME Vehicles in Queue (Main) Vehicles in Queue  (Secondary)Total TIME Vehicles in Queue (Main) Vehicles in Queue  (Secondary)Total 7:00 5 11:00 13 0 13 16:00 11 2 13 7:10 1 11:10 11 4 15 16:10 12 9 21 7:20 2 11:20 13 11 24 16:20 10 9 19 7:30 1 11:30 971616:30 11 13 24 7:40 1 11:40 831116:40 10 5 15 7:50 3 11:50 11 9 20 16:50 9514 8:00 4 12:00 941317:00 10 11 21 8:10 3 12:10 11 9 20 17:10 11 8 19 8:20 5 12:20 10 7 17 17:20 11 8 19 8:30 6 12:30 11 9 20 17:30 13 13 26 8:40 3 12:40 951417:40 13 15 28 8:50 1 12:50 63917:50 13 11 24 9:00 4 13:00 991818:00 11 14 25 TOTAL 39 13:10 10 7 17 18:10 12 9 21 13:20 891718:20 11 8 19 13:30 10 6 16 18:30 12 11 23 13:40 741118:40 10 12 22 13:50 11 9 20 18:50 13 12 25 14:00 671319:00 11 8 19 TOTAL 182 122 304 TOTAL 214 183 397 DRIVE THRU SURVEY LOCATION: Chick‐Fil‐A, 5080 Redwood Drive Date: 3/5/2022 CITY: Rohnert Park Day: Saturday TIME Vehicles in Queue TIME Vehicles in Queue (Main) Vehicles in Queue  (Secondary)Total TIME Vehicles in Queue (Main) Vehicles in Queue  (Secondary)Total 7:00 1 11:00 13 0 13 16:00 12 9 21 7:10 1 11:10 12 0 12 16:10 11 9 20 7:20 0 11:20 741116:20 12 10 22 7:30 1 11:30 641016:30 11 13 24 7:40 2 11:40 12 0 12 16:40 10 8 18 7:50 1 11:50 90916:50 13 10 23 8:00 2 12:00 741117:00 7411 8:10 4 12:10 81917:10 11 4 15 8:20 4 12:20 951417:20 10 7 17 8:30 5 12:30 10 6 16 17:30 13 14 27 8:40 6 12:40 10 9 19 17:40 14 15 29 8:50 3 12:50 661217:50 13 13 26 9:00 2 13:00 10 4 14 18:00 11 10 21 TOTAL 32 13:10 8101818:10 11 9 20 13:20 851318:20 14 16 30 13:30 991818:30 13 14 27 13:40 10 7 17 18:40 14 15 29 13:50 12 10 22 18:50 14 11 25 14:00 12 12 24 19:00 12 15 27 TOTAL 178 96 274 TOTAL 226 206 432 DRIVE THRU SURVEY     APPENDIX C    CHICK‐FIL‐A TRAFFIC MANAGEMENT PLAN  5080 Redwood Dr. Rohnert Park, CA 94928 August 24, 2022 TRAFFIC MANAGEMENT PLAN This plan identifies as a Critical Infrastructure layout of our peak and non-peak service at Chick- fil-A Rohnert Park FSU, located at 25080 Redwood Dr. Rohnert Park, CA 94928. Peak Time. Peak times are between 12:00 p.m. and 2:00 p.m. or when there are 24 vehicles in the drive-through line and/or drive-through stacking capacity blocks the drive-through bypass lane. During peak time operations ten to eleven team members will be outside to manage the flow of traffic in the drive-through by doing the following: •One traffic controller at the drive through entrance will direct the drive-through line and encourage cars to move forward as the line moves forward. •Four to five team members to take orders and accept credit card or app payments; •One cash person; •Two food runners outside; and •Two food runners outside to deliver curbside pick-up orders to the designated parking spaces. During the peak time the pass-by lane will be used as an additional food pick-up lane where cars will not merge but rather move forward and an employee will bring their food. This will allow these cars to exit the property. Non-peak Time. Non-Peak times are when there are 24 cars or less in our drive-through lane. During Non-peak operations there will be a total of seven team members outside to manage the flow of traffic in the drive-through lanes as outlined below: •Three to four team members to take orders and accept credit card and app payments; •One cash person; and •Two food runners. For curbside pick-up, we have one food runner outside to deliver orders to the designated parking spaces.