HomeMy WebLinkAbout2026/08/25 City Council Resolution 2026-065 RESOLUTION NO. 2026-065 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ROHNERT PARK TO UPDATE THE ROHNERT PARK MANUAL OF STANDARDS, DETAILS AND SPECIFICATIONS FOR THE WATER DETAIL DRAWINGS WHEREAS, the City's Manual of Standards, Details and Specifications (Standards) establishes the minimum engineering standards and requirements governing the design and construction of public infrastructure, private improvements to be dedicated to and accepted by the City for maintenance and operation, and improvements constructed within the public right- of-way and easement; and WHEREAS, Title 22 of the California Code of Regulations (Title 22) establishes minimum separation requirements between potable water mains and sewer, storm drain, and recycled water facilities to protect public drinking water; and WHEREAS,Title 22 allows municipalities and agencies that manage water systems to request alternate construction criteria through an approved Blanket Waiver issued by the State Water Resources Control Board Division of Drinking Water(Division); and WHEREAS, City staff submitted proposed Engineering Standard Detail 892 with alternative construction methods to the Division for review; and WHEREAS,on June 10, 2026, the Division approved the City's Blanket Waiver for alternate construction; and NOW, THEREFORE,BE IT RESOLVED by the City Council of the City of Rohnert Park that it does hereby incorporate Standard Detail 892 into the City's Manual of Standards, Details and Specifications in substantially similar form as attached hereto and incorporated herein as Exhibit A-1 and A-2. BE IT FURTHER RESOLVED that except as otherwise specified herein,the remaining Manual of Standards, Details and Specifications shall remain unchanged and in full effect. DULY AND REGULARLY ADOPTED BY THE CITY COUNCIL OF THE ROHNERT PARK on this 25th day of August, 2026. CITY OF ROHNERT PARK ELil Sanborn, Mayor ATTEST: Sylvia—orsez cuevas, City Clerk -- APPROVED14S TO FORM: r is . enyon, ity tt ey Attachments: Exhibit A-1, Exhibit A-2 ADAMS: "`jam GIUDICE: E RODRIGUEZ: ELWARD: SANBORN: (CI AYES: (s) NO S: (50 ) ABSENT: ) ABSTAIN: ( ) Resolution 2026-065 Page 2 of 2 Detail Drawings for Public Improvements Volume 2 Revised August 2026 City of Rohnert Park Water Detail Drawings Detail Drawings W-1 for Public Improvements Volume 2 Revised August 2026 WATER DETAIL DRAWINGS Standard Number Title Date Approved 800 Series 850 Reserved 851 Typical Harness Installation for Flange Fittings 2011 852 Typical Harness Installation 2006 853 Concrete Anchor Blocks for Vertical Bends 2006 854 Concrete Thrust Blocking for Horizontal Bends 2011 855 Reserved 856 Typical Water Main Installation Over Structure 2011 857 Fire Hydrant Installation, 2 Sheets 2011 858 Reserved 859 Typical Temporary Blow-off and/Or Metered Connection Mains Under Construction 2006 860 Typical Temporary Metered Connection Fire Flow Required 2011 861 Blow-off With Harness 2011 862 Full-Size Blow-off 2011 863A Water Service with Fire System Supply 1-inch and 1-1/2-inch Disc Meters 2017 863B Water Service 5/8-inch x 3/4-inch and 1-inch x 1-1/2-inch Disc Meters 2017 864A Dual Water Service with Fire System Supply 1-inch and 1-1/2-inch Disc Meters 2017 864B Dual Water Service 5/8-inch x 3/4-inch and 1-inch Disc Meters 2017 865A Water Service 2-inch Disc Meter 2011 865B 2-inch Commercial Water Service 2011 866 3-inch Commercial Water Service 2011 867 4-inch Commercial Water Service 2011 868 6-inch Commercial Water Service 2011 869 Typical Water Connection Detail 2011 870 Reserved 871 Typical Locations of Water Mains and Mainline Valves 2006 872 Dirt Stop and Water Main Encasement 2011 873 Reserved 874 Double Check Valve Backflow Assembly 2006 875 Reserved 876 Reduced-Pressure Backflow Assembly 2011 877 Gate Valve 2011 878 Butterfly Valve and Tapping Valve 2011 879 Underground Fire Line Single Detector Check Installation, 3 Sheets 2011 880 Double Check-Detector Check Fire Line Backflow Assembly 2011 881 Pressure Reducing Valves 2011 882 Surge Anticipator Valve Or Pressure Relief Valve 2011 883 Air and Vacuum and Air Release Valve 2017 Detail Drawings W-2 for Public Improvements Volume 2 Revised August 2026 Standard Number Title Date Approved 884 2006 885 2006 886 2011 887 2011 888 2011 891A 2011 891B 2011 891C Water Meter Installation for Private Nonresidential Systems Water Meter for Private Process and Evaporative Water Lines Water Sampling Station 4-inch Ductile Iron Multi-Service Manifold Water Service Obstructions Drinking Fountain Cover Detail Drinking Fountain Cover Detail Drinking Fountain Cover Detail Blanket Waiver for Separation Criteria Regarding Water Mains, Sewer Mains, Storm Drains, and Recycled Water Mains 2011 2026892 Water Main Construction Notes I.All material, workmanship, and construction details shall conform to the City of Rohnert Park "Standard Details and Specifications" 2006, including all addenda, standard plan revisions and special provisions. 2.Start excavation by exposing end of existing main to determine its line and grade. Start new main 8-10 feet from and on same line and grade as existing main. Pipe laying shall then be adjusted so depth of new main conforms to Note #3. 3.Minimum depth of cover from finished grade shall be 36 inches for 6-inch & 8-inch mains, 44 inches for 12-inch mains and 48 inches for 16-inch and larger mains. Ten-inch mains must be specifically approved by the City Engineer. Mainline valves smaller than 12 inches and smaller shall be resilient seat gate. Mainline valves larger than 12 inches shall be butterfly valves. Blow-off valves shall be 2-inch or 3-inch ball valves with rotation stops. 4.No. 12 insulated copper wire shall be laid on top of and along entire length of all non­ metallic mains and shall be extended to the surface at all valve locations, blow-offs, and meter boxes sufficiently for locator equipment to be attached. Fasten the wire to the top of the pipe so as not to be displaced by backfilling procedure ( one method of accomplishing this is to aflix the wire to the top of the pipe with duct tape at approximately IO foot intervals.) 5.Mains to be constructed within IO feet of sewer pipe require special installation and design must be specifically approved by the City Engineer and may require the approval of State Department of Health Services. 6.All trenching, backfill and resurfacing required for installation of water systems facilities shall be per City Std. 215. Show bedding type and trench backfill. 7.Only City Public Works Department Personnel shall operate valves on existing public system water mains or water services. 8.Service laterals other than those shown or noted on the plans shall not be installed prior to obtaining City Engineer approval. 9.Unless otherwise shown on the plans, I-inch minimum per standard detail 863A or 863B water service laterals shall be installed in residential developments and 2-inch minimum per standard detail 865B water service laterals shall be installed in commercial developments. 10.Water and sewer service laterals shall be separated horizontally by a minimum of 5 feet. 11.At the location of each water service lateral, the letter "W" shall be inscribed into the face of the curb. The letter "W" shall be 4 inches high and completely legible. Detail Drawings for Public Improvements W-3 Volume 2 Revised October 2010 12.All polyethylene water service tubing shall be in conformance with the latest A WWA Standards as described in ANSI/A WWA, and shall be polyethylene for I-inch tubing. Note: No copper allowed, use PE service tubing. 13.All meter boxes, vaults and pits shall be bedded on 3-inch minimum thick, 3/4-inch drain rock, AB-2, or other clean material with typical sand equivalent of20 minimum, uncontaminated by native soil, against compacted or undisturbed base. The gravel bed shall extend to a 4-inch minimum beyond all sides of the meter box. Box shall be set flush with top of curb, sidewalk or ground, whichever is applicable. Lot numbers must be noted on the topside of the meter box with a permanent marking pen. 14.Meter boxes shall be located out of traffic loading areas. 15.Meter boxes and vaults shall be set so that the reading lids are aligned over the meter registers as closely as possible. 16.Unless otherwise approved by the City, the on-site water line shall be minimum of the same size as the water meter. 17.For services larger than 1 inch, if either the water service lateral or the on-site building line is already existing within the tolerances specified on the Standard Detail, the last one installed shall be on the same line and grade as the existing one. 18.Items specified on the Standard Details, or the Engineers Approved List, are approved for use by the Public Works Department. All others shall be submitted lo the Engineering Department for approval. 19.Meter manifolds must be detailed by the designer and approved by the City Engineer. In general, manifolds where all fittings are 2 inches or less shall be constructed from threaded brass pipe and fittings from the end of the service lateral to the meter connection, No plastic pipe shall be used in constructing manifolds of any size. No more than six meters may be manifolded off of a single water service lateral, with no more than 4 on either side of the service. 20.Gaskets for flange fittings shall conform to AWWA STD. Cl 15. 21.To abandon a water service, expose, remove service saddle or tee and install stainless steel full circle clamp or spool with appropriate couplings per section XVII Abandonment of Water Mains and Services of the Manual of Standards, Design Standards. Note: Subject to City Engineer's inspection. 22.There shall be no unmetered connections to the City of Rohnert Park water system, including connections bypassing meter for testing on-site plumbing or for obtaining construction water. Pressure testing against valves will not be allowed. When a subdivision water main has been accepted and tied in, the individual curb stops will be Detail Drawings for Public Improvements W-4 Volume 2 Revised October 2010 locked off with a City padlock. Cutting off or tampering with the City padl ock will constitute a straight tie-in connection. Such connections will be severed by the City and will result in penalties including payment of fines and estimated water usage fees. 23.Upon application, Public Works' inspection personnel will observe installation of2-inch temporary check valve on the end of the existing main for construction water (See Standard 859). 24.Before combustible materials may be stored or constructed on site, the Fire Department must approve fire flow and access. Before a fire hydrant may be placed in service, a high velocity flushing of the hydrant lateral shall be witnessed and approved by Public Works inspector personnel. High-velocity flushing shall consist of removing the hydrant and replacing it with a suitable elbow and diffuser. Under Public Works observation, the hydrant lateral is flushed until Public Works' inspection personnel or fire division inspector are satisfied that the lines are clear of debris. Prior to operation of the on-site water main for construction related fire protection, meter and double-check valve assembly shall be certified by the appropriate personnel pursuant to Standard 860. 25.Upon completion of cons truction, final connection will be made by the contractor at the developer's expense under inspection by a City Public Works Inspector, unless otherwise specified on the plans. 26.For connections to an existing water main, the contractor shall provide all excavation, shoring, backfill and trench resurfacing per City of Rohnert Park standards. Where the connection is to be a "hot tap", the contractor shall provide and install the tapping valve and sleeve, and any other hardware required and will make the tap at the developer's expense. No hot tap shall be made within four feet of a joint (measured from joint to centerline of intersecting pipe). The joint shall be removed, and the proposed hot tap shall be replaced with a "cut-in" tee. When a "cut-in" tee and valve(s) assembly is required on the plans, the contractor shall provide and install the entire assembly (including valves), and any other hardware necessary under City Public Works' inspection, and shall provide all other work and materials necessary to complete the installation to City Standards. 27.The contractor shall coordinate all water main connection work with the City Public Works Inspector at (707) 588-2237, and shall give 48 hours notice, in accordance with Construction Specifications, prior to commencing work. Note: Contractor will notify affected property via door hanger or notice approved by City Engineer. 28.After a street has been overlaid, all water valve boxes will be marked in white paint before the close of that workday. 29.Within 48 hours of paving, all water valve boxes will be brought to grade and inspected. Detail Drawings for Public Improvements W-5 Volume 2 Revised October 2010 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-6 for Public Improvements Volume 2 Revised September 2022 Effective: ______________________ Standard 857 –Fire Hydrant and Lateral Hydrants Residential (All 2-2-1/2” and 1-4-1/2” outlet) Clow 960 Commercial (All 2-2-1/2” and 1-4-1/2” outlet) Clow 960 Hydrant Break-Off Check Valve Assembly Clow #40 Long Beach LB400 Hydrant Paint Coatings - Safety Blue and Aluminum Rust-Oleum Kelly Moore Paints Aluminum – 3415 Aluminum – 5880-530 Safety Blue – 5225 Safety Blue – 5780-564 Standard 858 – Typical Pumper Connection Details Low Profile Hydrant (1-2-1/2” and 1-4-1/2” outlet) Clow F-94 Hydrant Break-Off Check Valve Assembly (see St. 857) Clow #40 Long Beach LB400 Standard 861 – Blow-Off with Harness 2” Brass Ball Valve (FIP X FIP) Ford B11-777W Jones J-1900W McDonald 6101W Mueller B-20200 3” Brass Ball Valve Watts Series B-6000 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings for Public Improvements Volume 2 Revised September 2022 Boxes and Covers Size Location Box Number Cover Number 2” and 3” Traffic Christy B1324 Christy B1324-61JH 2” and 3” Non-traffic Christy B30 Quazite PG1324BA12 Christy FL30D Quazite PG1324WA50 Standard 862 – 8” Blow-Off Brass Ball Valve (FIP X FIP) Ford B11-777W Jones J-1900W McDonald 6101W Mueller B-20200 3” Brass Ball Valve Watts Series B-6000 Boxes and Covers Size Location Box Number Cover Number 8” Traffic Christy B2436 Quazite PG2436BA18 Christy B2436-62JH Quazite PG2436WAP250 8” Non-traffic Christy B40 Quazite PG2436BA18 Christy B40M Quazite PG2436WAP250 STANDARD 863A: Water Service W/ Fire System Supply 1” & 1-1/2” Disc Meters Angle Meter Ball Valve - Street Side (Comp. x MSN) or (Comp. x MSN) Ford 5/8” x 3/4” BA43-342W-Q 1” BA43-444W-Q 1-1/2”BFA43-666W-Q Jones 5/8” x 3/4” J-1963WSG – 1” x 3/4” 1” J-1963WSG – 1” 1-1/2”J-1975WSG – 1-1/2” McDonald 5/8” x 3/4” 4602BQ – 1” x 3/4” x 3/4” 1” 4602BQ – 1” 1-1/2”4602BQ – 1-1/2” Mueller 5/8” x 3/4” B-24258 – 5/8” x 3/4” x 1” 1” B-24258 – 1” 1-1/2”B-24276 – 1-1/2” Angle Meter Ball Valve - Property Side (MSN x FIP) or (MF x FIP) Ford 1” BA11-444W with HB-34S * 1-1/2”BA11-666W with HB-67S* (No Ell Required) Jones 1”J-1970W – 1” * W-7 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-8 for Public Improvements Volume 2 Revised September 2022 1-1/2”J-1900W – 1-1/2” * McDonald 1”4604BF – 1” * 1-1/2”6101W – 1-1/2” * Mueller 1”B-24287 with B-20298-99000 – 1” 1-1/2”B-24286 – 1-1/2” * with B-20298-99000 1-1/2" Valves require a brass street ell. * Requires a brass close nipple. Straight Meter Coupling - (MSN x MIP) Ford C38-44-1.5 Meter Flange - (MF x MIP) Ford CF 38-66-2 Jones J-129-M McDonald 610M Check Valve Watts CVY Red-White 236T Nibco T-413 Saddle - (AWWA CC Threaded Outlet) PVC C-900 Pipe Ford 202B Jones J-979 Mueller BR2B Series Ductile Iron Pipe Ford 202B Jones J-979 McDonald 3825 Mueller BR2B Series Corp Stop - (AWWA CC Thread x Comp.) Ford FB1000-4-Q FB1000-6-Q Jones J-3401SG – 1” J-1959SG – 1-1/2” McDonald 4701BQ Mueller B-25008 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-9 for Public Improvements Volume 2 Revised September 2022 Meter - (Read in gallons) 1” Badger Model 70 bronze disc meter w/bronze bottom, HRE 8 dial encoder, US Gal, torx, 5’ Itron ILC w/Itron ERT 100W+, 3 port with leak detector by Badger Meter. , 1-1/2” Badger Model 120 bronze disc meter w/test plug, 2 bolt elliptical flanges,HRE 8 dial encoder, US Gal, torx, 5’ Itron ILC w/Itron ERT 100W+, 3 port with leak detector by Badger Meter. ERT Bracket 1” Utilize register bracket or fiberglass rod 1-1/2”Utilize register bracket or fiberglass rod (Meter and Brackets can be obtained from Badger Meter or Pace Supply Corp) Meter Box and Cover 1” - Non-traffic Loading Box Cover Christy B30 FL30D BES C30 1” - Traffic Loading Box Cover Christy B1324 B1324-61GH BES C1324 C1324GH 1-1/2” - Non-traffic Loading Box Cover Christy B36 FL36D BES C36 1-1/2” - Traffic Loading Box Cover Christy B2436 B2436-61GH BES C2436 C2436GH STANDARD 863B: Water Service 5/8” x 3/4”, 1” & 1-1/2” Disc Meters Angle Meter Ball Valve - Street Side (Comp. x MSN) (For 1" and 1-1/2" meters see list for Standard 863A) Ford 5/8” x 3/4” BA43-342W-Q ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-10 for Public Improvements Volume 2 Revised September 2022 Jones 5/8” x 3/4” J-1963WSG – 1” x 3/4” McDonald 5/8” x 3/4” 4602BQ – 1” x 3/4” x 3/4” Mueller 5/8” x 3/4” B-24258 – 5/8” x 3/4” x 1” Angle Meter Ball Valve - Property Side (MSN x FIP) Ford 5/8” x 3/4” BA13-332W-HB-34S 1” BA13-444W-HB-34S 1-1/2”BFA13-666W-HB-67S Mueller 5/8” x 3/4” B-24265 with B-20298-99000 – 5/8” x 3/4” x 3/4” 1” B-24265 with B-20298-99000 – 1” 1-1/2”B-24286 – 1-1/2” Saddle See list for Standard 863A Corp Stop See list for Standard 863A Meter - (Read in gallons) 5/8” x 3/4” Badger Recordall Model 25 w/ RTR and 3-foot Register cable for use with a 5 foot in-line connector and Model 100WP+ with 3 ports and Leak Sensor + ITRON ERT w/6-inch Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com For 1" and 1-1/2" meters see Standard 863A ERT Bracket 5/8” x 3/4” Bracket to hang on cover support shoulder For 1" and 1-1/2" meters see Standard 863A Meter Box and Cover 5/8” x 3/4” - Non-traffic Loading Box Cover Christy B12 FL12D BES C12W 5/8” x 3/4” - Traffic Loading ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings for Public Improvements Volume 2 Revised September 2022 Box Cover Christy B1324 B1324-61GH BES C1324 C1324GH 1” and 1-1/2” - Non-traffic Loading Box Cover Christy B30 FL30D BES C30 1” and 1-1/2” - Traffic Loading Box Cover Christy B1324 B1324-61GH BES C1324 C1324GH STANDARD 864A: Dual Water Service w/ Fire Supply for 1” and 1-1/2” Disc Meters for Residential Meters Refer to STD 863A for specified parts STANDARD 864B: Dual Water Service for 5/8” x 3/4” & 1” Disc Meters (only with approval of City Engineer) For any part not listed here, see Standard 863A U-Branch Assembly Ford 5/8” x 3/4” U48-43-7.5Q 1” U48-64-9 Jones 5/8” x 3/4” J-2613SG 1” N/A McDonald 5/8” x 3/4” 08UQM – 1” x 3/4” x 7.5” 1” 08UTM – 1 1/2” x 1” x 9” Mueller 5/8” x 3/4” H-15363 - 1” x 3/4” x 7-1/2” 1” N/A Angle Meter Ball Valve – (FIP x MSN) Street side Ford 5/8” x 3/4” BA13-332W 1” BA13-444W Jones 5/8” x 3/4” J-1966W – 3/4” 1” J1966W – 1” McDonald 5/8” x 3/4” 4604B – 3/4” 1” 4604B – 1” Mueller 5/8” x 3/4” B-24265 – 5/8” x 3/4” x 3/4” 1” B-24265 – 1” W-11 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-12 for Public Improvements Volume 2 Revised September 2022 Meter Box and Cover Non-traffic Loading Box Cover Christy B24 B24E BES C24 C24E Traffic Loading (Requires two separate boxes. Refer to Standard 863B for box and cover.) STANDARD 865A: Water Service - 2” Disc Meter Saddle See list for Standard 863A Corp Stop – (AWWA CC Thread x Comp.) Ford FB1000-7-Q Jones J-1959SG McDonald 4701BQ Mueller B-25008 2" Brass Adapter – (MIP x comp.) Ford C84-77-Q Jones J-2605-SG McDonald 4779Q Mueller H-15428 Brass Elbow – (Comp. x FIP) Ford L14-77-Q Jones J-2621-SG McDonald 4753Q Mueller H-15533 Ball Angle Meter Valve – (FIP x MF) Ford BA11-777W Jones J-1900W McDonald 4604B Mueller B-24286 Meter - (Read in gallons) ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-13 for Public Improvements Volume 2 Revised September 2022 2” Badger Recordall Model 170 ELL, TP w/ RTR and 3-foot Register cable for use with a 5 foot in-line connector and Model 100WP+ with 3 ports and Leak Sensor + ITRON ERT w/6-inch Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B36 FL36D BES C36 Traffic Loading Box Cover Christy B1730 B1730-61GH BES C1730 C1730GH STANDARD 865B: 2” Commercial Water Service Saddle See list for Standard 863A Gate Valve See City Standard 877 2" Brass Adapter – (MIP x comp.) See list for Standard 865A Brass Elbow – (Comp. x FIP) See list for Standard 865A Strainer 2" Badger, Bronze, Dual Elliptical Flange Plate Strainer Meter - (Read in gallons) ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-14 for Public Improvements Volume 2 Revised September 2022 2"EL Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B40 B40-61G B40M (Sidewalks) BES C40 C40-61G C40M (Sidewalks) Traffic Loading Box Cover Christy B2436 B2436-62JH BES C2436 C2436GH Ball Valve with Lockwing and Stops – (FIP) Ford B11-444W Jones J-1900W McDonald 6101W Mueller B-20200 Flexible Meter Coupling with SS Bolts and Nuts Smith Blair 926 Two Bolt Dresser with SS Bolts and Nuts Smith Blair 411 Romac 511 Power Seal 3501 STANDARD 866: 3” Commercial Water Service Tapping Sleeve with SS Flange ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-15 for Public Improvements Volume 2 Revised September 2022 Romac STS420 Ford FTSS Mueller H-304SS Smith Blair 665 Gate Valve See City Standard 877 Strainer 3" Badger, Bronze, Dual Round Flange Plate Strainer Meter - (Read in gallons) 3"Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B40 B40-61G B40M (Sidewalks) BES C40 C40-61G C40M (Sidewalks) Traffic Loading Box Cover Christy B2436 B2436-61JH BES C2436 C2436GH Ball Valve with Stops and 2" Operating Nut – (FIP) Ford B11-777W Jones J-1900W McDonald 6101W Mueller B-20200 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-16 for Public Improvements Volume 2 Revised September 2022 FCA with SS Nuts and Bolts Smith Blair 912 Romac 501 Two Bolt Dresser See list for Standard 865B STANDARD 867: 4” Commercial Water Service Tapping Sleeve with SS Flange See list for Standard 866 Gate Valve See City Standard 877 Strainer 4" Badger, Bronze, Dual Round Flange Plate Strainer Meter - (Read in gallons) 4"Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box and Cover Non-traffic Loading Box Cover Christy B48 B48-62G B48M2 (Sidewalks) BES C48 C48-62G C48M2 (Sidewalks) Traffic Loading Box Cover ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-17 for Public Improvements Volume 2 Revised September 2022 Christy B3048 B3048-63JH BES C1324 C1324GH FCA with SS Nuts and Bolts See list for Standard 866 STANDARD 868: 6” Commercial Water Service Tapping Sleeve with SS Flange See list for Standard 866 Gate Valve See City Standard 877 Strainer 6" Badger, Bronze, Dual Round Flange Plate Strainer Meter 6"Badger Recordall Compound Series Meter w/ 2 RTR and 5-foot Register cable for use with in-line connector and 2-Model 100WP+ with 3 ports and Leak Sensor + ITRON ERTs w/5 foot Endpoint cable length with in-line connector, pit lid shelf-mount using snap on shelf mounting adapter, preprogrammed by National Meter & Automation, Inc. 707-575-0700, www.nmaai.com ERT Bracket Bracket to mount on side of meter box with SS anchors. Meter Box/ Cover/ Extensions Non-traffic Loading Box Cover Extensions Christy B52 B52-62G B52x10 B52M3 (Sidewalks) BES C52 C52-62G C52x10 C48M2 w/ C52L (Sidewalks) FCA with SS Nuts and Bolts See list for Standard 866 ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-18 for Public Improvements Volume 2 Revised September 2022 Standard 872 – Dirt Stop and Water Main Encasement Casing Spacers Calpico Inc. The Model M Series Cascade Model CCS Standard 874 –Double Check Valve Backflow Device Refer to current Approved Backflow Prevention Assembly list from University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC Foundation). Standard 876 – Reduced Pressure Backflow Assembly Refer to current Approved Backflow Prevention Assembly list from University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC Foundation). Standard 877 – Gate Valve Valve Box Bes M2 Brooks 4TT Christy G5 D & L M-9009 South Bay B21 Gate Valves Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient seated gate valves. (For example: Clow, US Pipe, American Flow Control). Standard 878 – Butterfly Valve & Tapping Valve Tapping Sleeves (Stainless Steel) – 4” and larger Size on size up to an including 8” on 8” (examples: 4” on 4”, 6” on 6”) and any combinations (examples: 4” on 8”, 6” on 8”) DIP, CIP, PVC and existing ACP: (Sleeve must be compatible with pipe type) Dresser Style 630 Ford FTSS JMC 415 JCM 432 Mueller H-304 Powerseal 3490 Romac SST111 Smith-Blair 664-665 For taps smaller than 4”, see appropriate standard. ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-19 for Public Improvements Volume 2 Revised September 2022 Standard 879 – Single Check Detector in Vault Detector Check Valve Ames 1000DCV Hersey EDC III Hersey EDC IV Precast Vault Cover Utility Vault Co. 44-SRW (4’ x 4’) 4848SRW Utility Vault Co. 555-SRW (5’ x 5’) 4848SRW (Pedestrian walkways must have Algrip surface) Standard 880 – Double Check Detector Fire Line Backflow Assembly Refer to current Approved Backflow Prevention Assembly list from University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC Foundation). Standard 881 – Pressure Reducing Valves Pressure Reducing Valves CLA-VAL 90-01 Singer 206-PRC Watts PV-10-01 Precast Vault and Cover Refer to Approved List for Standard 879. Standard 882 – Surge Anticipator Valve or Pressure Relief Valve Tapping Sleeves Refer to Approved List for Standard 878. Utility Box and Cover (Non-Traffic Loading) Boxes and Covers Box Number Cover Number Christy B48 Christy B48M2 Quazite PG3048BA18 Quazite LG3048WAQ150 Standard 883 – Air & Vacuum & Air Release Valve Tapping Service Saddle Refer to Approved List for Standard 863. ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-20 for Public Improvements Volume 2 Revised September 2022 1” Ball Valve Curb Stop (FIP x FIP) Ford B11-444W Jones J-1900 McDonald 6101W Mueller B-20200 1” Corporation Stop (AWWA/CC Taper Thread Inlet x MIP or FIP) Ford FB 400-4 Ford FB1600-4 Jones J-45 Jones J-51 McDonald 3128B McDonald 3148B Mueller B-20045 Mueller B-2996 1” 90º Elbow (MIP x Compression) Ford L84-44-Q Jones J-2619SG McDonald 4779MQ Mueller H-15531 1” 90º Brass Elbow (FIP x Compression) Ford L14-44-Q Jones J-2621SG McDonald 4779Q Mueller H-15533 Combination Valves APCO 143C Crispin UL10 Valmatic VM-201C Closure Boxes and Covers Location Box Number Cover Number Traffic Christy B36 Christy B36-61D Non-Traffic Christy B36 Christy FL36D Standard 884 – Water Meter for Private Non-Residential Systems 5/8” Resetter Ford VV32-12W 1” Resetter ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved _______________________ Detail Drawings W-21 for Public Improvements Volume 2 Revised September 2022 Ford VV34-15W Meter Boxes and Covers Size Location Box Number Cover Number 5/8” x 3/4” Traffic Christy B12 Christy B12C Non-Traffic Christy B12 Christy B12C 1” Traffic Christy B1324 Christy B1324-61GH Non-Traffic Christy B30 Christy FL30D Standard 885 – Water Meter for Private Process and Evaporative Water Lines 5/8” x 3/4" Resetter Ford Resetter-52 McDonald 40-2 Mueller H-1412 1” Resetter Ford Resetter-52 McDonald 40-2 Mueller H-1412 Standard 886 – Water Sampling Station Aluminum Cast Cabinet Kupferle Model 88WC Eclipse Standard 887 – 4” Ductile Iron Multi-Service Manifold MIP x Compression Coupler 3/4”, 1”, and 2” Ford C84-33-Q Ford C84-44-Q Ford C84-77-Q Jones J-2605SG McDonald 4753A Mueller H-15428 Tapping Service Saddles for Individual Services Refer to approved list for appropriate service lateral standard. Tapping Sleeves Refer to approved list for Standard 878. ENGINEER’S LIST OF APPROVED ITEMS For use with Water Design Standards Approved ______________________ Detail Drawings W-22 for Public Improvements Volume 2 Revised September 2022 APPROVED: Julian De Anda City Engineer State Water Resources Control Board Division of Drinking Water June 10, 2026 Water System No. 4910014 Mark Hendersen Utilities Operations Manager mhendersen@rpcity.org CITY OF ROHNERT PARK – APPROVAL OF ALTERNATE CONSTRUCTION BLANKET WAIVER Thank you for submitting the City of Rohnert Park’s (City) proposal for Alternate Construction Blanket Waivers (Blanket Waivers) to California Code of Regulations, Title 22, Chapter 16, Section 64572, Water Main Separation. The Blanket Waivers have been submitted in accordance with Section 64551.100, Waivers and Alternatives, and have been reviewed by the State Water Resources Control Board Division of Drinking Water (Division). The Division approves the enclosed Blanket Waivers. As stated in the City’s submittal, the alternatives will be used only when the water main separation distances specified in the regulations cannot be met due to existing conditions. The City shall maintain records documenting each instance in which a Blanket Waiver is applied, the log must including the location, approved waiver case that applies (ex. crossing of water main below storm drain). If you have any questions regarding this letter, please contact Rajendra Khanal of my staff at rajendra.khanal@waterboards.ca.gov. General inquiries to our office can be made by emailing ddwsantarosa@waterboards.ca.gov or calling (707) 576-2145. Sincerely, Misha Anderson, P.E. District Engineer, Sonoma District Division of Drinking Water State Water Resources Control Board Enclosures and cc recipients on page 2 - 2 -June 10, 2026 Mark Hendersen 4910014/08 – Waivers/Separation Standards/Blanket Separation Standard Waiver 260610 - Blanket Waiver Approval 4910014.docx/RK PWSS-P&TR-PAD-W&A-WW Enclosure: May 21, 2026, City of Rohnert Park Separation Detail CC (via email): Julian De Anda - jdeanda@rpcity.org SEPARATION OF WATER MAINS, SEWER MAINS, STORM DRAINS, & RECYCLED WATER MAINS NEW FACILITIES SEPARATION STANDARDS CRITERIA: 1. New water mains, sewer mains, storm drain mains, and recycled water mains must comply with most recent version of California Code of Regulations Section 64572 Title 22 Chapter 16 for separation standards. 2. Minimum dimensions (separation distances) are measured from outside to outside of pipe barrel and outside of manhole. 3. All fittings and/or connections to pipes shall comply with all City Design and Construction Standards and this Standard Detail. 4.Standard Crossing Construction Separation Criteria: A. Pressure water main must be at least 1 foot above sanitary sewer main, recycled water main, storm drain main at crossing point location and water main pipe material must be constructed of the following materials: a. PVC (Polyvinyl Chloride) DR18 Pressure Class 235 per AWWA C900 and C905; Gaskets per ASTM F477; Joints per ASTM D3139, Fittings per AWWA C907 b. DIP (Ductile Iron Pipe) Pressure Class CL350 per AWWA C151, Joints per AWWA C111, Fittings per AWWA C110. B. No connection joints shall be installed in the water main within 8 horizontal feet of the fluid pipeline. C. Crossing angle between pipes must be between 45 degrees and 90 degrees 5.Standard Parallel Construction Separation Criteria: A. Distance from pressure water main to sewer main and recycled water main must be at least 10 feet horizontally and 1 foot vertically above. Water main pipe material must be constructed as described in note 3 above. B. Distance from pressure water main to storm drain main must be at least 4 feet horizontally and 1 foot vertically above. Water main pipe material must be constructed as described in note 4 above. 6. Pressure water mains must not be installed in the same trench as other supply lines. 7. Pipe, joints, and fittings shall be installed with as much separation as field conditions allow. RECYCLED WATER MAIN SEPARATION CRITERIA REQUIREMENTS: 1. Recycled water mains shall be treated as sewer mains when considering their separation from potable water. 2. Recycled water mains shall be treated as potable water mains when considering their separation from sewers. ALTERNATIVE CRITERIA FOR SEPARATION OF WATER MAINS, SEWER MAINS, STORM DRAIN MAINS & RECYCLED WATER MAINS: When local conditions or existing facilities create a situation where there is no alternative but to install pressure water mains at a distance less than what is required by the new facilities separation standards criteria, the alternative construction criteria shall apply as approved by the City of Rohnert Park and by The State Water Resources Control Board, Division of Drinking Water, Blanket Waiver (per CCR, Title 22, Section 64551.100). NEW WATER MAIN ALTERNATIVE CRITERIA PIPE MATERIAL: Special Pipe =one. Water pipe material requirement for water main pipe up to18 inches in diameter. Larger size water main pipe requires prior city written approval for water pipe material and sanitary separation. A. PVC (Polyvinyl Chloride) pipe PC 305 DR 14 per AWWA 900 and AWWA C905; Joints per ASTM D3139; Fittings per AWWA C907 B. PE (Polyethylene) pipe DR 9 per AWWA C906; Fused joints per ASTM F2620; Fittings per AWWA C906 C. DIP (Ductile Iron Pipe) pipe Class CL350 per AWWA C151; wrapped per AWWA C105; Joints per AWWA C111; Fittings per AWWA C110 or AWWA C219. D. All couplings must be bolted per AWWA C219 NEW SEWER MAIN ALTERNATIVE CRITERIA PIPE MATERIAL: Special Pipe =one. Sewer pipe material requirements for existing watermain pipe up to 18 inches in diameter. Larger size water main pipe diameter requires prior city written approval for sewer pipe material and sanitary separation. A. PVC (Polyvinyl Chloride) pipe SDR26 per ASTM D3034 or PS115 (ASTM F679) or DR25(AWWA C900); Joints per ASTM D3212 or ASTM D3139; Fittings per ASTM F1336 or AWWA C907. B. PE (Polyethylene) pipe DR 13.5 per AWWA C906; Fused per ASTM F2620; Fittings per AWWA C906. C. DIP (Ductile Iron Pipe) pipe Class CL350 per AWWA C151; wrapped per AWWA C105; Joints per AWWA C111; Fittings per AWWA C110 or AWWA C153. D. All couplings must be bolted per AWWA C219 NEW STORM DRAIN MAIN ALTERNATIVE CRITERIA PIPE MATERIAL: Special Pipe =one. Special storm drain pipe material requirements for watermain pipe up to 18 inches in diameter. Larger size water main pipe diameter requires prior city written approval for storm drain pipe material and sanitary separation. A. PVC (Polyvinyl Chloride) pipe SDR26 per ASTM D3034 or PS115 (ASTM F679) or DR25(AWWA C900); Joints per ASTM D3212 or ASTM D3139; Fittings per ASTM F1336 or AWWA C907. B. PE (Polyethylene) pipe smooth interior walls per ASTM F2306; Joints per ASTM D3212; Fittings per ASTM F2306. C. RCP (Reinforced Concrete Pipe) pipe Class III, Class IV, Class V, as shown on the plans per ASTM C76; Joints per ASTM C443; Fittings: N/A. D. All couplings must be bolted per AWWA C219 HOUSE SEWER LATERALS 1. 4-inch and 6-inch house sewer laterals that cross above water mains shall be constructed per page 10 of these details and have a minimum of a 4 inch separation between water main and sewer lateral as shown. BLANKET WAIVER FOR SEPARATION CRITERIA REGARDING WATER MAINS, SEWER MAINS, STORM DRAIN MAINS & RECYCLED WATER MAINS SCALE: NTS DATE: May 2026 APPROVED: CITY OF ROHNERT PARK STD. - 892 PAGE 1 OF 10 SEWER MAIN PIPE SEWER MAIN PIPE NO COUPLINGS OR JOINTS VERTICAL VIEW - NEW WATER MAIN ABOVE SEWER MAIN NO COUPLINGS OR JOINTS VERTICAL VIEW - NEW WATER MAIN BELOW SEWER MAIN S E W E R M A I N P I P E PLAN VIEW - NEW WATER MAIN ABOVE SEWER MAIN RESTRAINED COUPLING (TYP.) RESTRAINED BELL AND SPIGOT PIPE JOINT (TYP.) RESTRAINED COUPLING (TYP.) RESTRAINED PIPE JOINT (TYP.) NO COUPLINGS OR JOINTS 4 FT.4 FT. NO COUPLINGS OR JOINTS 45 DEGREES MIN. BETWEEN PIPES 45 DEGREES MIN. BETWEEN PIPES SPECIAL PIPE & JOINT ZONE SEE PG. 1 INSTALL COMPRESSIBLE MATERIAL, SEE NOTE 3 CLSM BETWEEN PIPES AND TO BOTTOM OF NEW PIPE TRENCH 6 MIL POLYETHYLENE PLASTIC SHEETING BETWEEN PIPE AND CLSM, FULL TRENCH LENGTH 4 FT.4 FT. 6 INCHES MINIMUM NEW WATER MAIN PIPE NE W W A T E R M A I N P I P E 1 FT. MIN. (TYP.) RESTRAINT JOINT REQUIRED RESTRAINT JOINT REQUIRED MAIN P I P E S E W E R M A I N P I P E ONE FULL UNCUT LENGTH OF NEW PIPE CENTERED AT CROSSING POINT SPECIAL PIPE & JOINT ZONE SEE PG.1 1 FT. MIN. (TYP.) ONE FULL UNCUT LENGTH OF NEW PIPE CENTERED AT CROSSING POINT 6 FT. MIN. (TYP.) 8 FT.8 FT. TO EDGE OF TRENCH (TYPICAL) PLAN VIEW - NEW WATER MAIN BELOW SEWER MAIN 6 INCHES MINIMUM SPECIAL PIPE & JOINT ZONE SEE PG. 1 NEW W A T E R SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 RESTRAINT JOINT REQUIRED (TYP.) RESTRAINT JOINT REQUIRED (TYP.) NEW WATER MAIN PIPE SCALE: NTS APPROVED: CITY OF ROHNERT PARK BLANKET WAIVER SEPARATION CRITERIA - NEW WATER MAIN CROSSING SEWER MAIN ACRONYMSABBREVIATIONS CLSM= CONTROLLED LOW STRENGTH MATERIAL TYP.=TYPICAL; MIN.=MINIMUM NOTES: 1. Only to be used where field conditions make it infeasible to achieve standard separation per California Waterworks Standards Section 64572 and to be approved prior to use by City of Rohnert Park. 2. The City of Rohnert Park may impose additional site-specific requirements or restrictions to protect its facilities and provide access for future maintenance. 3. Compressible material must be 1" thick and must be neoprene, styrene-butadiene, or approved equal material. STD. - 892 PAGE 2 OF 10 DATE: MAY 2026 SEWER MAIN PIPE NO PIPE CONSTRUCTION ALLOWED 4 FT. NO PIPE CONSTRUCTION ALLOWED 4 FT. 10 FT. PLAN VIEW - NEW WATER MAIN PARALLEL TO SEWER MAIN VERTICAL VIEW - NEW WATER MAIN PARALLEL TO SEWER MAIN PIPE CENTERLINE 4 FT. N E W W A T E R M A I N P I P E NO PIPE CONSTRUCTION ALLOWED 10 FT.10 FT. S E W E R M A I N P I P E SPECIAL PIPE & JOINT ZONE SEE PG. 1 PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 BLANKET WAIVER SEPARATION CRITERIA - NEW WATER MAIN PARALLEL TO SEWER MAIN SCALE: NTS APPROVED: CITY OF ROHNERT PARK STD. - 892 PAGE 3 OF 10 ACRONYMSABBREVIATIONS CLSM= CONTROLLED LOW STRENGTH MATERIAL TYP.=TYPICAL; MIN.=MINIMUM NOTES: 1.Only to be used where field conditions make it infeasible to achieve standard separation per California Waterworks Standards Section 64572 and to be approved prior to use by City of Rohnert Park. 2.The City of Rohnert Park may impose additional site-specific requirements or restrictions to protect its facilities and provide access for future maintenance. 3.Compressible material must be 1" thick and must be neoprene, styrene-butadiene, or approved equal material. DATE: MAY 2026 N E W S E W E R M A I N P I P E WATER MAIN PIPE N2 SEWER &28PLINGS 2R -2INTS 9ERTI&AL 9IEW  NEW SEWER MAIN A%29E WATER MAIN PLAN 9IEW  NEW SEWER MAIN %EL2W WATER MAIN PIPE SPRINGLINE PIPE SPRINGLINE &LSM %ETWEEN PIPES  )T MIN T<P  )T WATER MAIN PIPE N2 SEWER &28PLINGS 2R -2INTS 9ERTI&AL 9IEW  NEW SEWER MAIN %EL2W WATER MAIN  IN&+ES MINIM8M NE W S E W E R M A I N P I P E PLAN 9IEW  NEW SEWER MAIN A%29E WATER MAIN &LSM T2 E'GE 2) TREN&+ T<PI&AL  )T MIN T<PI&AL RESTRAINE' &28PLING T<P RESTRAINE' PIPE -2INT T<P NEW SEWER MAIN PIPE NEW SEWER MAIN PIPE N2 SEWER &28PLINGS 2R -2INTS N2 SEWER &28PLINGS 2R -2INTS  )T )T RESTRAINE' &28PLING T<P RESTRAINE' -2INT T<P  'EGREES MIN %ETWEEN PIPES  MIL P2L<ET+<LENE PLASTI& S+EETING %ETWEEN PIPE AN' &LSM )8LL TREN&+ LENGT+ SPE&IAL PIPE -2INT =2NE SEE PG  )T M A I N P I P E W A T E R W A T E R M A I N P I P E 2NE )8LL 8N&8T LENGT+ 2) PIPE &ENTERE' AT &R2SING P2INT 2NE )8LL 8N&8T LENGT+ 2) PIPE &ENTERE' AT &R2SING P2INT SPE&IAL PIPE -2INT =2NE SEE PG INSTALL &2MPRESSI%LE MATERIAL SEE N2TE  IN&+ES MINIM8M SPE&IAL PIPE -2INT =2NE SEE PG   )T MIN )T MIN  )T )T SPE&IAL PIPE -2INT =2NE SEE PG  SPE&IAL PIPE -2INT =2NE SEE PG  SPE&IAL PIPE -2INT =2NE SEE PG  RESTRAINE' PIPE -2INT T<P RESTRAINE' -2INT T<P  'EGREES MIN S&ALE NTS APPR29E' &IT< 2) R2+NERT PAR. %LAN.ET WAI9ER SEPARATI2N &RITERIA  NEW SEWER MAIN &R2SSING WATER MAIN ST'   PAGE  2)  A&R2N<MSA%%RE9IATI2NS &LSM &2NTR2LLE' L2W STRENGT+ MATERIAL T<P T<PI&AL MIN MINIM8M N2TES  2QO\ WR EH XVHG ZKHUH ILHOG FRQGLWLRQV PDNH LW LQIHDVLEOH WR DFKLHYH VWDQGDUG VHSDUDWLRQ SHU &DOLIRUQLD WDWHUZRUNV SWDQGDUGV SHFWLRQ  DQG WR EH DSSURYHG SULRU WR XVH E\ &LW\ RI RRKQHUW PDUN  TKH &LW\ RI RRKQHUW PDUN PD\ LPSRVH DGGLWLRQDO VLWHVSHFLILF UHTXLUHPHQWV RU UHVWULFWLRQV WR SURWHFW LWV IDFLOLWLHV DQG SURYLGH DFFHVV IRU IXWXUH PDLQWHQDQFH  &RPSUHVVLEOH PDWHULDO PXVW EH  WKLFN DQG PXVW EH QHRSUHQH VW\UHQHEXWDGLHQH RU DSSURYHG HTXDO PDWHULDO 'ATE MA<  NO PIPE CONSTRUCTION ALLOWED 4 FT. WATER MAIN PIPE N E W S E W E R M A I N P I P E 4 FEET 10 FT. PLAN VIEW - NEW SEWER MAIN PARALLEL TO WATERMAIN VERTICAL VIEW - NEW SEWER MAIN PARALLEL TO WATERMAIN 10 FT.10 FT. 4 FT. W A T E R M A I N P I P E NO PIPE CONSTRUCTION ALLOWED NO PIPE CONSTRUCTION ALLOWED PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA SCALE: NTS APPROVED: CITY OF ROHNERT PARK BLANKET WAIVER SEPARATION CRITERIA - NEW SEWER MAIN PARALLEL TO WATER MAIN STD. - 892 PAGE 5 OF 10 ACRONYMSABBREVIATIONS CLSM= CONTROLLED LOW STRENGTH MATERIAL TYP.=TYPICAL; MIN.=MINIMUM NOTES: 1.Only to be used where field conditions make it infeasible to achieve standard separation per California Waterworks Standards Section 64572 and to be approved prior to use by City of Rohnert Park. 2.The City of Rohnert Park may impose additional site-specific requirements or restrictions to protect its facilities and provide access for future maintenance. 3.Compressible material must be 1" thick and must be neoprene, styrene-butadiene, or approved equal material. DATE: MAY 2026 WATER MAIN PIPE NO STORM DRAIN COUPLINGS OR JOINTS VERTICAL VIEW - NEW STORM DRAIN ABOVE WATER MAIN PLAN VIEW - NEW STORM DRAIN BELOW WATER MAIN 4 FT.WATER MAIN PIPE NO STORM DRAIN COUPLINGS OR JOINTS VERTICAL VIEW - NEW STORM DRAIN BELOW WATER MAIN 6 INCHES MINIMUM PLAN VIEW - NEW STORM DRAIN ABOVE WATER MAIN PIPE CENTERLINE NO STORM DRAIN COUPLINGS OR JOINTS NO STORM DRAIN COUPLINGS OR JOINTS 4 FT.4 FT. SPECIAL PIPE & JOINT ZONE SEE PG.1 4 FT. M A I N P I P E W A T E R 45 DEGREES MIN. BETWEEN PIPES ONE FULL UNCUT LENGTH OF PIPE CENTERED AT CROSSING POINT 45 DEGREES MIN. BETWEEN PIPES COUPLING (TYP.) COUPLING (TYP.) SPECIAL PIPE & JOINT ZONE SEE PG.1 NEW STORM DRAIN PIPE NEW STORMDRAIN PIPE NE W S T O R M D R A I N P I P E SPECIAL PIPE & JOINT ZONE SEE PG. 1 PIPE SPRINGLINE UPPER PIPE SPRINGLIN E 6 INCHES MINIMUM INSTALL COMPRESSIBLE MATERIAL , SEE NOTE 3 CLSM ONE FULL UNCUT LENGTH PIPE CENTERED AT CROSING POINT 6 MIL POLYETHYLENE PLASTIC SHEETING BETWEEN PIPE AND CLSM, FULL TRENCH WIDTH 3 FT. MIN.3 FT. MIN. DRAIN PIPENEW STORM W A T E R M A I N P I P E 3 FT. MIN.3 FT. MIN. SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 BLANKET WAIVER NEW STORM DRAIN PIPE CROSSING WATER MAIN PIPE SCALE: NTS APPROVED: CITY OF ROHNERT PARK STD. - 892 PAGE 6 OF 10 ACRONYMSABBREVIATIONS CLSM= CONTROLLED LOW STRENGTH MATERIAL TYP.=TYPICAL; MIN.=MINIMUM NOTES: 1. Only to be used where field conditions make it infeasible to achieve standard separation per California Waterworks Standards Section 64572 and to be approved prior to use by City of Rohnert Park. 2. The City of Rohnert Park may impose additional site-specific requirements or restrictions to protect its facilities and provide access for future maintenance. 3. Compressible material must be 1" thick and must be neoprene, styrene-butadiene, or approved equal material. DATE: MAY 2026 NO PIPE CONSTRUCTION ALLOWED WATER MAIN PIPE 3 FT. PLAN VIEW - NEW STORM DRAIN PIPE PARALLEL TO WATERMAIN VERTICAL VIEW - NEW STORM DRAIN PIPE PARALLEL TO WATERMAIN 3 FT.3 FT. W A T E R M A I N P I P E NO PIPE CONSTRUCTION ALLOWED N E W S T O R M D R A I N M A I N P I P E SPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 4 FT. 4 FT. NO PIPE CONSTRUCTION ALLOWED 4 FT. PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA SPECIAL PIPE & JOINT ZONE SEE PG. 1 BLANKET WAIVER NEW STORM DRAIN PIPE PARALLEL TO WATER MAIN PIPE SCALE: NTS APPROVED: CITY OF ROHNERT PARK STD. - 892 PAGE 7 OF 10 ACRONYMSABBREVIATIONS CLSM= CONTROLLED LOW STRENGTH MATERIAL TYP.=TYPICAL; MIN.=MINIMUM NOTES: 1.Only to be used where field conditions make it infeasible to achieve standard separation per California Waterworks Standards Section 64572 and to be approved prior to use by City of Rohnert Park. 2.The City of Rohnert Park may impose additional site-specific requirements or restrictions to protect its facilities and provide access for future maintenance. 3.Compressible material must be 1" thick and must be neoprene, styrene-butadiene, or approved equal material. DATE: MAY 2026 S T O R M D R A I N M A I N P I P E SD PIPE NO &O8P/IN*S OR -OINTS 9ERTI&A/ 9IEW  NEW WATER MAIN A%O9E STORM DRAIN PIPE P/AN 9IEW NEW WATER MAIN %E/OW STORM DRAIN PIPE  )T MIN SD PIPE NO &O8P/IN*S OR -OINTS 9ERTI&A/ 9IEW  NEW WATER MAIN %E/OW STORM DRAIN PIPE S T O R M D R A I N P I P E P/AN 9IEW NEW WATER MAIN A%O9E STORM DRAIN PIPE RESTRAINED &O8P/IN* T<P RESTRAINED PIPE -OINT T<P RESTRAINED &O8P/IN* T<P RESTRAINED PIPE -OINT T<P ONE )8// 8N&8T /EN*T+  )OOT STI&. O) PIPE &ENTERED AT &ROSSIN* POINT NO &O8P/IN*S OR -OINTS  )T )T NO &O8P/IN*S OR -OINTS  DE*REES MIN %ETWEEN PIPES  DE*REES MIN %ETWEEN PIPES SPE&IA/ PIPE -OINT =ONE SPE&IA/ PIPE -OINT =ONE SPE&IA/ PIPE -OINT =ONE  )T  IN&+ES MINIM8M TO ED*E O) TREN&+ T<PI&A/ ONE )8// 8N&8T /EN*T+ O) PIPE &ENTERED AT &ROSIN* POINT NEW WATER MAIN PIPE NE W W A T E R M A I N P I P E  )T MIN T<P NEW WATER MAIN PIPE RESTRAINED -OINT T<P NEW W A T E R M A I N P I P E  )T  IN&+ES MINIM8M INSTA// &OMPRESSI%/E MATERIA/ SEE NOTE   MI/ PO/<ET+</ENE P/ASTI& S+EETIN* %ETWEEN PIPE AND &/SM )8// TREN&+ /EN*T+ SPE&IA/ PIPE -OINT =ONE SPE&IA/ PIPE -OINT =ONE SPE&IA/ PIPE -OINT =ONE RESTRAINED -OINT T<P  )T )T RESTRAINED -OINT T<P &/SM %ETWEEN PIPES AND TO %OTTOM O) TREN&+ S&A/E NTS APPRO9ED &IT< O) RO+NERT PAR. %/AN.ET WAI9ER NEW WATER MAIN PIPE &ROSSIN* STORM DRAIN PIPE STD   PA*E  O)  A&RON<MSA%%RE9IATIONS &/SM &ONTRO//ED /OW STREN*T+ MATERIA/ T<P T<PI&A/ MIN MINIM8M NOTES  OQO\ WR EH XVHG ZKHUH ILHOG FRQGLWLRQV PDNH LW LQIHDVLEOH WR DFKLHYH VWDQGDUG VHSDUDWLRQ SHU &DOLIRUQLD WDWHUZRUNV SWDQGDUGV SHFWLRQ  DQG WR EH DSSURYHG SULRU WR XVH E\ &LW\ RI RRKQHUW PDUN  TKH &LW\ RI RRKQHUW PDUN PD\ LPSRVH DGGLWLRQDO VLWHVSHFLILF UHTXLUHPHQWV RU UHVWULFWLRQV WR SURWHFW LWV IDFLOLWLHV DQG SURYLGH DFFHVV IRU IXWXUH PDLQWHQDQFH  &RPSUHVVLEOH PDWHULDO PXVW EH  WKLFN DQG PXVW EH QHRSUHQH VW\UHQHEXWDGLHQH RU DSSURYHG HTXDO PDWHULDO DATE MA<  3 FT. PLAN VIEW - NEW WATER MAIN PARALLEL TO STORM DRAIN PIPE N E W W A T E R M A I N P I P E S T O R M D R A I N M A I N P I P E 3 FT. NO PIPE CONSTRUCTION ALLOWED STORM DRAIN PIPE VERTICAL VIEW - NEW WATER MAIN PIPE PARALLEL TO STORM DRAIN PIPE 3 FT. NO PIPE CONSTRUCTION ALLOWED 4 FT. 4 FT. NO PIPE CONSTRUCTION ALLOWED SPECIAL PIPE & JOINT ZONE SEE PG. 1 4 FT. PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIA PIPE CONSTRUCTION PER STANDARD SEPARATION CRITERIASPECIAL PIPE & JOINT ZONE SEE PG. 1 SPECIAL PIPE & JOINT ZONE SEE PG. 1 SCALE: NTS APPROVED: CITY OF ROHNERT PARK BLANKET WAIVER NEW WATER MAIN PIPE PARALLEL TO STORM DRAIN PIPE STD. - 892 PAGE 9 OF 10 ACRONYMSABBREVIATIONS CLSM= CONTROLLED LOW STRENGTH MATERIAL TYP.=TYPICAL; MIN.=MINIMUM NOTES: 1.Only to be used where field conditions make it infeasible to achieve standard separation per California Waterworks Standards Section 64572 and to be approved prior to use by City of Rohnert Park. 2.The City of Rohnert Park may impose additional site-specific requirements or restrictions to protect its facilities and provide access for future maintenance. 3.Compressible material must be 1" thick and must be neoprene, styrene-butadiene, or approved equal material. DATE: MAY 2026 WATER MAIN PIPE 4" AND 6" DIAMETER SERVICE LATERALS PER CITY STANDARD 513 6 INCHES MINIMUM 10 FEET 10 FEET WRAPPED JOINT WITH TWO LAYERS OF WRAP TAPE. REFER TO NOTES (TYP.) ALL JOINTS TO BE TAPE WRAPPED WITHIN 10 FEET OF WATER MAIN 3 FEET (MIN.) VERTICAL VIEW - NEW SEWER SERVICE LATERAL ABOVE WATER MAIN SCALE: NTS APPROVED: CITY OF ROHNERT PARK BLANKET WAIVER NON TYPICAL INSTALLATION - SEWER SERVICE LATERAL ABOVE WATER MAIN ACRONYMSABBREVIATIONS CLSM= CONTROLLED LOW STRENGTH MATERIAL TYP.=TYPICAL; MIN.=MINIMUM NOTES: 1.Only to be used where field conditions make it infeasible to achieve standard separation per California Waterworks Standards Section 64572 and to be approved prior to use by the City of Rohnert Park. 2.The City of Rohnert Park may impose additional site-specific requirements or restrictions to protect its facilities and provide access for future maintenance 3.Pipe wrap pipe tape shall be "Christy's TA-33-PW21" for DIP, "Pasco 9052R" for PVC or approved equal and installed per manufacturer's recommendations with related primer. 4.Pipe wrap tape shall be wrapped spirally with 1 inch overlap and press to remove all air pockets to provided smooth lap seams. 5.A second layer of pipe wrap tape shall be applied in the opposite direction as the first layer. 6.Visible gaps in tape wrap will not be allowed.STD. - 892 PAGE 10 OF 10 DATE: MAY 2026